{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T23:21:43Z","timestamp":1788477703613,"version":"build-2803163510"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T00:00:00Z","timestamp":1746144000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T00:00:00Z","timestamp":1746144000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Research Cooperation with Siemens Healthiness"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>The growing demand for follow-up imaging highlights the need for tools supporting the assessment of pulmonary nodules over time. We evaluated the performance of an artificial intelligence (AI)-based system for automated nodule matching.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>In this single-center study, patients with nodules and \u2264\u20092 chest computed tomography (CT) examinations were retrospectively selected. An AI-based algorithm was used for automated nodule detection and matching. The matching rate and the causes for incorrect matching were evaluated for the ten largest lesions (5\u201330\u2009mm in diameter) registered on baseline CT. The dependence of the matching rate on nodule number and localization was also analyzed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>One hundred patients (46 females), with a median age of 62 years (interquartile range 57\u201369), and 253 CTs were included. Focusing on the ten largest lesions, 1,141 lesions were identified, of which 36 (3.2%) were other structures incorrectly identified as nodules (false-positives). Of the 1,105 identified nodules, 964 (87.2%) were correctly detected and matched. The matching rate for nodules registered in both baseline and follow-up scans was 97.8%. The matching rate per case ranged 80.0\u2013100.0% (median 90.0%). Correct matching rate decreased in follow-up examinations to over 50 nodules (<jats:italic>p<\/jats:italic>\u2009=\u20090.003), with an overrepresentation of missed matching. Matching rates were higher in parenchymal (91.8%), peripheral (84.4%), and juxtavascular (82.4%) nodules than in juxtaphrenic nodules (71.1%) (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Missed matching was overrepresented in juxtavascular, and incorrect assignment in juxtaphrenic nodules.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The correct automated-matching rate of metastatic pulmonary nodules in follow-up examinations was high, but it depends on localization and a number of nodules.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Relevance statement<\/jats:title>\n            <jats:p>The algorithm enables precise follow-up matching of pulmonary nodules, potentially providing a solid basis for standardized and accurate evaluations. Understanding the algorithm\u2019s strengths and weaknesses based on nodule localization and number enhances the interpretation of AI-based results.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Key Points<\/jats:title>\n            <jats:p>\n              <jats:list list-type=\"bullet\">\n                <jats:list-item>\n                  <jats:p>The AI algorithm achieved a correct nodule matching rate of 87.2% and up to 97.8% when considering nodules detected in both baseline and follow-up scans.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Matching accuracy depended on nodule number and localization.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>This algorithm has the potential to support response evaluation criteria in solid tumor-based evaluations in clinical practice.<\/jats:p>\n                <\/jats:list-item>\n              <\/jats:list>\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Graphical Abstract<\/jats:title>\n          <\/jats:sec>","DOI":"10.1186\/s41747-025-00579-w","type":"journal-article","created":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T17:13:22Z","timestamp":1746206002000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Artificial intelligence-based automated matching of pulmonary nodules on follow-up chest CT"],"prefix":"10.1186","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3089-9606","authenticated-orcid":false,"given":"Nicola","family":"Fink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan I.","family":"Sperl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Rueckel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theresa","family":"St\u00fcber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sophia S.","family":"Goller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Rudolph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Escher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theresia","family":"Aschauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boj F.","family":"Hoppe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Ricke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bastian O.","family":"Sabel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,2]]},"reference":[{"key":"579_CR1","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1148\/rg.2018180017","volume":"38","author":"J Bueno","year":"2018","unstructured":"Bueno J, Landeras L, Chung JH (2018) Updated Fleischner Society guidelines for managing incidental pulmonary nodules: common questions and challenging scenarios. Radiographics 38:1337\u20131350. https:\/\/doi.org\/10.1148\/rg.2018180017","journal-title":"Radiographics"},{"key":"579_CR2","doi-asserted-by":"publisher","first-page":"2400","DOI":"10.1001\/jama.2012.5960","volume":"307","author":"R Smith-Bindman","year":"2012","unstructured":"Smith-Bindman R, Miglioretti DL, Johnson E et al (2012) Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996\u20132010. JAMA 307:2400\u20132409. https:\/\/doi.org\/10.1001\/jama.2012.5960","journal-title":"JAMA"},{"key":"579_CR3","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1001\/jama.2019.11456","volume":"322","author":"R Smith-Bindman","year":"2019","unstructured":"Smith-Bindman R, Kwan ML, Marlow EC et al (2019) Trends in use of medical imaging in US health care systems and in Ontario, Canada, 2000\u20132016. JAMA 322:843\u2013856. https:\/\/doi.org\/10.1001\/jama.2019.11456","journal-title":"JAMA"},{"key":"579_CR4","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1148\/radiol.2017161659","volume":"284","author":"H MacMahon","year":"2017","unstructured":"MacMahon H, Naidich DP, Goo JM et al (2017) Guidelines for management of incidental pulmonary nodules detected on CT images: from the Fleischner Society 2017. Radiology 284:228\u2013243. https:\/\/doi.org\/10.1148\/radiol.2017161659","journal-title":"Radiology"},{"key":"579_CR5","doi-asserted-by":"publisher","first-page":"2260","DOI":"10.1001\/jama.2018.16336","volume":"320","author":"IJ Anderson","year":"2018","unstructured":"Anderson IJ, Davis AM (2018) Incidental pulmonary nodules detected on CT images. JAMA 320:2260\u20132261. https:\/\/doi.org\/10.1001\/jama.2018.16336","journal-title":"JAMA"},{"key":"579_CR6","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1164\/rccm.201505-0990OC","volume":"192","author":"MK Gould","year":"2015","unstructured":"Gould MK, Tang T, Liu ILA et al (2015) Recent trends in the identification of incidental pulmonary nodules. Am J Respir Crit Care Med 192:1208\u20131214. https:\/\/doi.org\/10.1164\/rccm.201505-0990OC","journal-title":"Am J Respir Crit Care Med"},{"key":"579_CR7","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1056\/NEJMoa1214726","volume":"369","author":"A McWilliams","year":"2013","unstructured":"McWilliams A, Tammemagi MC, Mayo JR et al (2013) Probability of cancer in pulmonary nodules detected on first screening CT. N Engl J Med 369:910\u2013919. https:\/\/doi.org\/10.1056\/NEJMoa1214726","journal-title":"N Engl J Med"},{"key":"579_CR8","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1056\/NEJMoa1102873","volume":"365","author":"The National Lung Screening Trial Research Team","year":"2011","unstructured":"The National Lung Screening Trial Research Team (2011) Reduced lung-cancer mortality with Low-dose computed tomographic screening. N Engl J Med 365:395\u2013409. https:\/\/doi.org\/10.1056\/NEJMoa1102873","journal-title":"N Engl J Med"},{"key":"579_CR9","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1056\/NEJMoa1911793","volume":"382","author":"HJ de Koning","year":"2020","unstructured":"de Koning HJ, van der Aalst CM, de Jong PA et al (2020) Reduced lung-cancer mortality with volume CT screening in a randomized trial. N Engl J Med 382:503\u2013513. https:\/\/doi.org\/10.1056\/NEJMoa1911793","journal-title":"N Engl J Med"},{"key":"579_CR10","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1136\/thoraxjnl-2016-209825","volume":"72","author":"E Paci","year":"2017","unstructured":"Paci E, Puliti D, Lopes Pegna A et al (2017) Mortality, survival and incidence rates in the ITALUNG randomised lung cancer screening trial. Thorax 72:825\u2013831. https:\/\/doi.org\/10.1136\/thoraxjnl-2016-209825","journal-title":"Thorax"},{"key":"579_CR11","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1038\/s41571-020-00432-6","volume":"18","author":"M Oudkerk","year":"2021","unstructured":"Oudkerk M, Liu S, Heuvelmans MA, Walter JE, Field JK (2021) Lung cancer LDCT screening and mortality reduction\u2014evidence, pitfalls and future perspectives. Nat Rev Clin Oncol 18:135\u2013151. https:\/\/doi.org\/10.1038\/s41571-020-00432-6","journal-title":"Nat Rev Clin Oncol"},{"key":"579_CR12","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.1093\/annonc\/mdz117","volume":"30","author":"U Pastorino","year":"2019","unstructured":"Pastorino U, Silva M, Sestini S et al (2019) Prolonged lung cancer screening reduced 10-year mortality in the MILD trial: new confirmation of lung cancer screening efficacy. Ann Oncol 30:1162\u20131169. https:\/\/doi.org\/10.1093\/annonc\/mdz117","journal-title":"Ann Oncol"},{"key":"579_CR13","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1002\/ijc.32486","volume":"146","author":"N Becker","year":"2020","unstructured":"Becker N, Motsch E, Trotter A et al (2020) Lung cancer mortality reduction by LDCT screening\u2014results from the randomized German LUSI trial. Int J Cancer 146:1503\u20131513. https:\/\/doi.org\/10.1002\/ijc.32486","journal-title":"Int J Cancer"},{"key":"579_CR14","doi-asserted-by":"publisher","first-page":"106","DOI":"10.3322\/caac.21172","volume":"63","author":"R Wender","year":"2013","unstructured":"Wender R, Fontham ETH, Barrera E Jr et al (2013) American cancer society lung cancer screening guidelines. CA Cancer J Clin 63:106\u2013117. https:\/\/doi.org\/10.3322\/caac.21172","journal-title":"CA Cancer J Clin"},{"key":"579_CR15","doi-asserted-by":"publisher","first-page":"2418","DOI":"10.1001\/jama.2012.5521","volume":"307","author":"PB Bach","year":"2012","unstructured":"Bach PB, Mirkin JN, Oliver TK et al (2012) Benefits and harms of CT screening for lung cancer: a systematic review. JAMA 307:2418\u20132429. https:\/\/doi.org\/10.1001\/jama.2012.5521","journal-title":"JAMA"},{"key":"579_CR16","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1080\/17476348.2020.1697853","volume":"14","author":"TJ Kim","year":"2020","unstructured":"Kim TJ, Kim CH, Lee HY et al (2020) Management of incidental pulmonary nodules: current strategies and future perspectives. Expert Rev Respir Med 14:173\u2013194. https:\/\/doi.org\/10.1080\/17476348.2020.1697853","journal-title":"Expert Rev Respir Med"},{"key":"579_CR17","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.lungcan.2004.06.007","volume":"47","author":"JK Gohagan","year":"2005","unstructured":"Gohagan JK, Marcus PM, Fagerstrom RM et al (2005) Final results of the lung screening study, a randomized feasibility study of spiral CT versus chest x-ray screening for lung cancer. Lung Cancer 47:9\u201315. https:\/\/doi.org\/10.1016\/j.lungcan.2004.06.007","journal-title":"Lung Cancer"},{"key":"579_CR18","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1164\/ajrccm.165.4.2107006","volume":"165","author":"S Swensen","year":"2002","unstructured":"Swensen S, Jett J, Sloan J et al (2002) Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med 165:508\u2013513. https:\/\/doi.org\/10.1164\/ajrccm.165.4.2107006","journal-title":"Am J Respir Crit Care Med"},{"key":"579_CR19","doi-asserted-by":"publisher","first-page":"e1247","DOI":"10.1002\/cnr2.1247","volume":"3","author":"C Rajasooriyar","year":"2020","unstructured":"Rajasooriyar C, Sritharan T, Chenthuran S et al (2020) The role of staging computed tomography on detection of occult metastasis in asymptomatic breast cancer patients. Cancer Rep 3:e1247. https:\/\/doi.org\/10.1002\/cnr2.1247","journal-title":"Cancer Rep"},{"key":"579_CR20","doi-asserted-by":"publisher","first-page":"743","DOI":"10.2214\/AJR.22.27598","volume":"219","author":"B Yacoub","year":"2022","unstructured":"Yacoub B, Varga-Szemes A, Schoepf UJ et al (2022) Impact of artificial intelligence assistance on chest CT interpretation times: a prospective randomized study. AJR Am J Roentgenol 219:743\u2013751. https:\/\/doi.org\/10.2214\/AJR.22.27598","journal-title":"AJR Am J Roentgenol"},{"key":"579_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.media.2017.06.015","volume":"42","author":"AAA Setio","year":"2017","unstructured":"Setio AAA, Traverso A, de Bel T et al (2017) Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: the LUNA16 challenge. Med Image Anal 42:1\u201313. https:\/\/doi.org\/10.1016\/j.media.2017.06.015","journal-title":"Med Image Anal"},{"key":"579_CR22","doi-asserted-by":"publisher","first-page":"e0266799","DOI":"10.1371\/journal.pone.0266799","volume":"17","author":"JT Murchison","year":"2022","unstructured":"Murchison JT, Ritchie G, Senyszak D et al (2022) Validation of a deep learning computer aided system for CT based lung nodule detection, classification, and growth rate estimation in a routine clinical population. PLoS One 17:e0266799. https:\/\/doi.org\/10.1371\/journal.pone.0266799","journal-title":"PLoS One"},{"key":"579_CR23","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.2214\/AJR.20.24807","volume":"216","author":"L Chelala","year":"2021","unstructured":"Chelala L, Hossain R, Kazerooni EA et al (2021) Lung-RADS version 1.1: challenges and a look ahead, from the AJR special series on radiology reporting and data systems. AJR Am J Roentgenol 216:1411\u20131422. https:\/\/doi.org\/10.2214\/AJR.20.24807","journal-title":"AJR Am J Roentgenol"},{"key":"579_CR24","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1016\/j.ejca.2008.10.026","volume":"45","author":"EA Eisenhauer","year":"2009","unstructured":"Eisenhauer EA, Therasse P, Bogaerts J et al (2009) New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). Eur J Cancer 45:228\u2013247. https:\/\/doi.org\/10.1016\/j.ejca.2008.10.026","journal-title":"Eur J Cancer"},{"key":"579_CR25","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.ejrad.2019.07.030","volume":"118","author":"H Beaumont","year":"2019","unstructured":"Beaumont H, Bertrand AS, Klifa C et al (2019) Radiology workflow for RECIST assessment in clinical trials: Can we reconcile time-efficiency and quality? Eur J Radiol 118:257\u2013263. https:\/\/doi.org\/10.1016\/j.ejrad.2019.07.030","journal-title":"Eur J Radiol"},{"key":"579_CR26","doi-asserted-by":"publisher","first-page":"91","DOI":"10.2214\/AJR.11.7522","volume":"199","author":"CW Koo","year":"2012","unstructured":"Koo CW, Anand V, Girvin F et al (2012) Improved efficiency of CT interpretation using an automated lung nodule matching program. AJR Am J Roentgenol 199:91\u201395. https:\/\/doi.org\/10.2214\/AJR.11.7522","journal-title":"AJR Am J Roentgenol"},{"key":"579_CR27","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1109\/TPAMI.2017.2782687","volume":"41","author":"FC Ghesu","year":"2019","unstructured":"Ghesu FC, Georgescu B, Zheng Y et al (2019) Multi-scale deep reinforcement learning for real-time 3D-landmark detection in CT scans. IEEE Trans Pattern Anal Mach Intell 41:176\u2013189. https:\/\/doi.org\/10.1109\/TPAMI.2017.2782687","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"579_CR28","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1007\/978-3-319-24574-4_28","volume":"9351","author":"O Ronneberger","year":"2015","unstructured":"Ronneberger O, Fischer P, Brox T (2015) U-Net: convolutional networks for biomedical image segmentation. MICCAI 9351:234\u2013241. https:\/\/doi.org\/10.1007\/978-3-319-24574-4_28","journal-title":"MICCAI"},{"key":"579_CR29","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.2214\/AJR.19.21572","volume":"214","author":"AM Fischer","year":"2020","unstructured":"Fischer AM, Varga-Szemes A, van Assen M et al (2020) Comparison of artificial intelligence-based fully automatic chest CT emphysema quantification to pulmonary function testing. AJR Am J Roentgenol 214:1065\u20131071. https:\/\/doi.org\/10.2214\/AJR.19.21572","journal-title":"AJR Am J Roentgenol"},{"key":"579_CR30","doi-asserted-by":"publisher","unstructured":"Rusinkiewicz S, Levoy M (2001) Efficient variants of the ICP algorithm. In: Proceedings of the third international conference on 3-D digital imaging and modeling. Princeton University, pp 145\u2013152. https:\/\/doi.org\/10.1109\/IM.2001.924423","DOI":"10.1109\/IM.2001.924423"},{"key":"579_CR31","doi-asserted-by":"publisher","DOI":"10.1186\/s12916-021-01928-3","volume":"19","author":"J Chamberlin","year":"2021","unstructured":"Chamberlin J, Kocher MR, Waltz J et al (2021) Automated detection of lung nodules and coronary artery calcium using artificial intelligence on low-dose CT scans for lung cancer screening: accuracy and prognostic value. BMC Med 19:55. https:\/\/doi.org\/10.1186\/s12916-021-01928-3","journal-title":"BMC Med"},{"key":"579_CR32","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1097\/rti.0000000000000613","volume":"37","author":"AF Abadia","year":"2022","unstructured":"Abadia AF, Yacoub B, Stringer N et al (2022) Diagnostic accuracy and performance of artificial intelligence in detecting lung nodules in patients with complex lung disease: a noninferiority study. J Thorac Imaging 37:154\u2013161. https:\/\/doi.org\/10.1097\/rti.0000000000000613","journal-title":"J Thorac Imaging"},{"key":"579_CR33","doi-asserted-by":"publisher","first-page":"e08961","DOI":"10.1016\/j.heliyon.2022.e08962","volume":"8","author":"MR Kocher","year":"2022","unstructured":"Kocher MR, Chamberlin J, Waltz J et al (2022) Tumor burden of lung metastases at initial staging in breast cancer patients detected by artificial intelligence as a prognostic tool for precision medicine. Heliyon 8:e08961. https:\/\/doi.org\/10.1016\/j.heliyon.2022.e08962","journal-title":"Heliyon"},{"key":"579_CR34","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1055\/s-2004-813144","volume":"176","author":"F Beyer","year":"2004","unstructured":"Beyer F, Wormanns D, Novak C et al (2004) Clinical evaluation of a software for automated localization of lung nodules at follow-up examinations. Rofo 176:829\u2013836. https:\/\/doi.org\/10.1055\/s-2004-813144","journal-title":"Rofo"},{"key":"579_CR35","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.2214\/ajr.07.2057","volume":"189","author":"KW Lee","year":"2007","unstructured":"Lee KW, Kim M, Gierada DS et al (2007) Performance of a computer-aided program for automated matching of metastatic pulmonary nodules detected on follow-up chest CT. AJR Am J Roentgenol 189:1077\u20131081. https:\/\/doi.org\/10.2214\/ajr.07.2057","journal-title":"AJR Am J Roentgenol"},{"key":"579_CR36","doi-asserted-by":"publisher","first-page":"624","DOI":"10.2214\/AJR.08.1307","volume":"192","author":"C Tao","year":"2009","unstructured":"Tao C, Gierada DS, Zhu F et al (2009) Automated matching of pulmonary nodules: evaluation in serial screening chest CT. AJR Am J Roentgenol 192:624\u2013628. https:\/\/doi.org\/10.2214\/AJR.08.1307","journal-title":"AJR Am J Roentgenol"},{"key":"579_CR37","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1148\/radiol.2361041286","volume":"236","author":"KT Bae","year":"2005","unstructured":"Bae KT, Kim JS, Na YH et al (2005) Pulmonary nodules: automated detection on CT images with morphologic matching algorithm\u2014preliminary results. Radiology 236:286\u2013293. https:\/\/doi.org\/10.1148\/radiol.2361041286","journal-title":"Radiology"},{"key":"579_CR38","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1148\/radiol.2261011708","volume":"226","author":"MS Brown","year":"2003","unstructured":"Brown MS, Goldin JG, Suh RD et al (2003) Lung micronodules: automated method for detection at thin-section CT\u2014initial experience. Radiology 226:256\u2013262. https:\/\/doi.org\/10.1148\/radiol.2261011708","journal-title":"Radiology"},{"key":"579_CR39","doi-asserted-by":"publisher","first-page":"626.e23","DOI":"10.1016\/j.crad.2021.04.006","volume":"76","author":"HH Hsu","year":"2021","unstructured":"Hsu HH, Ko KH, Chou YC et al (2021) Performance and reading time of lung nodule identification on multidetector CT with or without an artificial intelligence-powered computer-aided detection system. Clin Radiol 76:626.e23\u2013626.e32. https:\/\/doi.org\/10.1016\/j.crad.2021.04.006","journal-title":"Clin Radiol"},{"key":"579_CR40","doi-asserted-by":"publisher","first-page":"e0240184","DOI":"10.1371\/journal.pone.0240184","volume":"15","author":"BS Erdal","year":"2020","unstructured":"Erdal BS, Demirer M, Little KJ et al (2020) Are quantitative features of lung nodules reproducible at different CT acquisition and reconstruction parameters? PLoS One 15:e0240184. https:\/\/doi.org\/10.1371\/journal.pone.0240184","journal-title":"PLoS One"},{"key":"579_CR41","doi-asserted-by":"publisher","DOI":"10.1186\/s40644-024-00770-z","volume":"24","author":"Y Yao","year":"2024","unstructured":"Yao Y, Su X, Deng L et al (2024) Effects of tube voltage, radiation dose and adaptive statistical iterative reconstruction strength level on the detection and characterization of pulmonary nodules in ultra-low-dose chest CT. Cancer Imaging 24:123. https:\/\/doi.org\/10.1186\/s40644-024-00770-z","journal-title":"Cancer Imaging"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00579-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-025-00579-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00579-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T17:13:23Z","timestamp":1746206003000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-025-00579-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,2]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["579"],"URL":"https:\/\/doi.org\/10.1186\/s41747-025-00579-w","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,2]]},"assertion":[{"value":"10 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Institutional Review Board (University Hospital LMU Munich, Germany; number 18-399, 07\/02\/2018) approval was obtained. Written informed consent was waived by the Institutional Review Board.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"JIS is affiliated with Siemens Healthineers. The remaining authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"48"}}