{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T02:01:53Z","timestamp":1780711313790,"version":"3.54.1"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T00:00:00Z","timestamp":1747612800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T00:00:00Z","timestamp":1747612800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100011068","name":"Fondation Saint Luc","doi-asserted-by":"publisher","award":["NA"],"award-info":[{"award-number":["NA"]}],"id":[{"id":"10.13039\/501100011068","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Pelvimetry is essential in obstetrics for delivery planning. While computed tomography (CT) is the standard, magnetic resonance imaging (MRI) offers a radiation-free alternative with zero echo time (ZTE) and black bone (BB) sequences providing high bone-to-soft tissue contrast within short scan times. This proof-of-concept study evaluates the reliability of these sequences and the agreement with CT for pelvimetry in a predominantly elderly population.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This retrospective study included 21 female patients who underwent 3-T whole-body MRI including ZTE and BB sequences and <jats:sup>18<\/jats:sup>fluorodeoxyglucose (<jats:sup>18<\/jats:sup>F-FDG) positron emission tomography (PET)\/CT with optimized low-dose whole-body CT. Obstetric conjugate diameter (OCD), interspinous diameter (ISD), and median transverse diameter (MTD) were measured by five radiologists. Intra-reader, inter-reader, and inter-technique agreement were assessed using intraclass correlation coefficient (ICC) and repeatability\/reproducibility coefficients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Intra-reader agreement was good regardless of diameter or reader: all ICC\u2009\u2265\u20090.90, repeatability ranging from \u00b1\u20090.26 to \u00b1\u20090.48\u2009cm (CT), \u00b1\u20090.30 to \u00b1\u20090.52\u2009cm (BB), and \u00b1\u20090.29 to \u00b1\u20090.67\u2009cm (ZTE). The inter-reader agreement was good regardless of sequence: all ICC\u2009\u2265\u20090.88, reproducibility ranging from \u00b1\u20090.39 to \u00b1\u20090.42 (OCD), \u00b1\u20090.26 to \u00b1\u20090.51\u2009cm (ISD), and \u00b1\u20090.53 to \u00b1\u20090.58\u2009cm (MTD). ZTE and BB showed similar agreement with CT: \u00b1\u20090.57 to \u00b1\u20090.81\u2009cm when including inter-reader variability; \u00b1\u20090.34 to \u00b1\u20090.47\u2009cm for only intra-reader variability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>ZTE and BB sequences provided reliable measurements with good agreement with CT, for obstetric pelvimetry. Further validation in the context of pregnancy is needed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Relevance statement<\/jats:title>\n            <jats:p>MRI-based pseudo-CT sequences are a promising radiation-free alternative to CT for obstetric pelvimetry, offering the prospect of accurate, reliable measurements of pelvic diameters in pregnant women.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Trial registration<\/jats:title>\n            <jats:p>The population included female patients with suspected multiple myeloma from a previous prospective oncology trial (ClinicalTrials.gov: NCT05381077).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Key Points<\/jats:title>\n            <jats:p>\n              <jats:list list-type=\"bullet\">\n                <jats:list-item>\n                  <jats:p>This study explores pseudo-CT MRI sequences for radiation-free\u00a0non-invasive obstetric pelvimetry.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Pseudo-CT zero echo time and black bone sequences provide repeatable and reproducible measurements of pelvic diameters.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Pseudo-CT MRI sequences show good inter-technique agreement with the reference CT.<\/jats:p>\n                <\/jats:list-item>\n              <\/jats:list>\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Graphical Abstract<\/jats:title>\n          <\/jats:sec>","DOI":"10.1186\/s41747-025-00585-y","type":"journal-article","created":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T12:43:16Z","timestamp":1747658596000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["MRI-based pseudo-CT sequences as a radiation-free alternative to CT for obstetric pelvimetry: a proof-of-concept study"],"prefix":"10.1186","volume":"9","author":[{"given":"Caroline","family":"Chabot","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathilde","family":"Haegeman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eya","family":"Chaouch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dana","family":"Dumitriu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renaud","family":"Menten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia","family":"Steenhaut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Bernard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Perrine","family":"Triqueneaux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Michoux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3568-3254","authenticated-orcid":false,"given":"Fr\u00e9d\u00e9ric E.","family":"Lecouvet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,19]]},"reference":[{"key":"585_CR1","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1097\/00003081-200006000-00004","volume":"43","author":"JE Ferguson 2nd","year":"2000","unstructured":"Ferguson 2nd JE, Sistrom CL (2000) Can fetal-pelvic disproportion be predicted. Clin Obstet Gynecol 43:247\u2013264. https:\/\/doi.org\/10.1097\/00003081-200006000-00004","journal-title":"Clin Obstet Gynecol"},{"key":"585_CR2","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1080\/00016349808565809","volume":"77","author":"TK Lau","year":"1998","unstructured":"Lau TK, Leung CM, Li CY (1998) A study of the use of radiological pelvimetry in a Chinese population. Acta Obstet Gynecol Scand 77:41\u201344","journal-title":"Acta Obstet Gynecol Scand"},{"key":"585_CR3","first-page":"497","volume":"98","author":"JN Ane","year":"1946","unstructured":"Ane JN (1946) Roentgen pelvimetry. New Orleans Med Surg J 98:497\u2013502","journal-title":"New Orleans Med Surg J"},{"key":"585_CR4","first-page":"455","volume":"68","author":"JN Kopelman","year":"1986","unstructured":"Kopelman JN, Duff P, Karl RT et al (1986) Computed tomographic pelvimetry in the evaluation of breech presentation. Obstet Gynecol 68:455\u2013458","journal-title":"Obstet Gynecol"},{"key":"585_CR5","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1016\/0002-9378(90)91082-n","volume":"163","author":"SS Christian","year":"1990","unstructured":"Christian SS, Brady K, Read JA et al (1990) Vaginal breech delivery: a five-year prospective evaluation of a protocol using computed tomographic pelvimetry. Am J Obstet Gynecol 163:848\u2013855. https:\/\/doi.org\/10.1016\/0002-9378(90)91082-n","journal-title":"Am J Obstet Gynecol"},{"key":"585_CR6","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-53603-1","volume":"14","author":"C Tresch","year":"2024","unstructured":"Tresch C, Lallemant M, Nallet C et al (2024) Updating of pelvimetry standards in modern obstetrics. Sci Rep 14:3080. https:\/\/doi.org\/10.1038\/s41598-024-53603-1","journal-title":"Sci Rep"},{"key":"585_CR7","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1016\/s0221-0363(04)97677-9","volume":"85","author":"S Garnier","year":"2004","unstructured":"Garnier S, Bertrand P, Chapiron C et al (2004) Low dose helical CT pelvimetry: evaluation of radiation dose and image processing. J Radiol 85:747\u2013753. https:\/\/doi.org\/10.1016\/s0221-0363(04)97677-9","journal-title":"J Radiol"},{"key":"585_CR8","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1097\/00004728-199109000-00011","volume":"15","author":"RC Smith","year":"1991","unstructured":"Smith RC, McCarthy S (1991) Improving the accuracy of digital CT pelvimetry. J Comput Assist Tomogr 15:787\u2013789. https:\/\/doi.org\/10.1097\/00004728-199109000-00011","journal-title":"J Comput Assist Tomogr"},{"key":"585_CR9","first-page":"425","volume":"84","author":"C Balleyguier","year":"2003","unstructured":"Balleyguier C, Jouanic JM, Corr\u00e9as JM et al (2003) CT pelvimetry: a new approach using multi detector CT and volume rendering. J Radiol 84:425\u2013427","journal-title":"J Radiol"},{"key":"585_CR10","doi-asserted-by":"publisher","first-page":"947","DOI":"10.2214\/ajr.144.5.947","volume":"144","author":"DD Stark","year":"1985","unstructured":"Stark DD, McCarthy SM, Filly RA et al (1985) Pelvimetry by magnetic resonance imaging. AJR Am J Roentgenol 144:947\u2013950. https:\/\/doi.org\/10.2214\/ajr.144.5.947","journal-title":"AJR Am J Roentgenol"},{"key":"585_CR11","doi-asserted-by":"publisher","first-page":"137","DOI":"10.2214\/ajr.179.1.1790137","volume":"179","author":"S Sporri","year":"2002","unstructured":"Sporri S, Thoeny HC, Raio L et al (2002) MR imaging pelvimetry: a useful adjunct in the treatment of women at risk for dystocia? AJR Am J Roentgenol 179:137\u2013144. https:\/\/doi.org\/10.2214\/ajr.179.1.1790137","journal-title":"AJR Am J Roentgenol"},{"key":"585_CR12","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1148\/radiol.2492072009","volume":"249","author":"ME Lockhart","year":"2008","unstructured":"Lockhart ME, Fielding JR, Richter HE et al (2008) Reproducibility of dynamic MR imaging pelvic measurements: a multi-institutional study. Radiology 249:534\u2013540. https:\/\/doi.org\/10.1148\/radiol.2492072009","journal-title":"Radiology"},{"key":"585_CR13","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1002\/jmri.28164","volume":"56","author":"C Chen","year":"2022","unstructured":"Chen C, Yang M, Zheng W et al (2022) Magnetic resonance imaging-based nomogram to antenatal predict cesarean delivery for cephalopelvic disproportion in primiparous women. J Magn Reson Imaging 56:1145\u20131154. https:\/\/doi.org\/10.1002\/jmri.28164","journal-title":"J Magn Reson Imaging"},{"key":"585_CR14","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1148\/radiol.2271011658","volume":"227","author":"TM Keller","year":"2003","unstructured":"Keller TM, Rake A, Michel SC et al (2003) Obstetric MR pelvimetry: reference values and evaluation of inter- and intraobserver error and intraindividual variability. Radiology 227:37\u201343. https:\/\/doi.org\/10.1148\/radiol.2271011658","journal-title":"Radiology"},{"key":"585_CR15","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-28459-6","volume":"13","author":"O Ami","year":"2023","unstructured":"Ami O, Maran JC, Cohen A et al (2023) Childbirth simulation to assess cephalopelvic disproportion and chances for failed labor in a French population. Sci Rep 13:1110. https:\/\/doi.org\/10.1038\/s41598-023-28459-6","journal-title":"Sci Rep"},{"key":"585_CR16","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/j.ejrad.2018.03.024","volume":"102","author":"KD Liao","year":"2018","unstructured":"Liao KD, Yu YH, Li YG et al (2018) Three-dimensional magnetic resonance pelvimetry: a new technique for evaluating the female pelvis in pregnancy. Eur J Radiol 102:208\u2013212. https:\/\/doi.org\/10.1016\/j.ejrad.2018.03.024","journal-title":"Eur J Radiol"},{"key":"585_CR17","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1055\/a-0715-2122","volume":"191","author":"A von Bismarck","year":"2019","unstructured":"von Bismarck A, Ertl-Wagner B, St\u00f6cklein S et al (2019) MR pelvimetry for breech presentation at term- interobserver reliability, incidental findings and reference values. Rofo 191:424\u2013432. https:\/\/doi.org\/10.1055\/a-0715-2122","journal-title":"Rofo"},{"key":"585_CR18","doi-asserted-by":"publisher","first-page":"e0161028","DOI":"10.1371\/journal.pone.0161028","volume":"11","author":"J Hoffmann","year":"2016","unstructured":"Hoffmann J, Thomassen K, Stumpp P et al (2016) New MRI criteria for successful vaginal breech delivery in primiparae. PLoS One 11:e0161028. https:\/\/doi.org\/10.1371\/journal.pone.0161028","journal-title":"PLoS One"},{"key":"585_CR19","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/s0009-9260(98)80130-x","volume":"53","author":"SM Thomas","year":"1998","unstructured":"Thomas SM, Bees NR, Adam EJ (1998) Trends in the use of pelvimetry techniques. Clin Radiol 53:293\u2013295. https:\/\/doi.org\/10.1016\/s0009-9260(98)80130-x","journal-title":"Clin Radiol"},{"key":"585_CR20","doi-asserted-by":"publisher","first-page":"4680","DOI":"10.1007\/s00330-020-07597-9","volume":"31","author":"BJ Schwaiger","year":"2021","unstructured":"Schwaiger BJ, Schneider C, Kronthaler S et al (2021) CT-like images based on T1 spoiled gradient-echo and ultra-short echo time MRI sequences for the assessment of vertebral fractures and degenerative bone changes of the spine. Eur Radiol 31:4680\u20134689. https:\/\/doi.org\/10.1007\/s00330-020-07597-9","journal-title":"Eur Radiol"},{"key":"585_CR21","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1097\/RLI.0000000000000506","volume":"54","author":"T Finkenstaedt","year":"2019","unstructured":"Finkenstaedt T, Siriwanarangsun P, Achar S et al (2019) Ultrashort time-to-echo magnetic resonance imaging at 3 T for the detection of spondylolysis in cadaveric spines: comparison with CT. Invest Radiol 54:32\u201338. https:\/\/doi.org\/10.1097\/RLI.0000000000000506","journal-title":"Invest Radiol"},{"key":"585_CR22","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1097\/brs.0000000000002462","volume":"43","author":"EC Argentieri","year":"2018","unstructured":"Argentieri EC, Koff MF, Breighner RE et al (2018) Diagnostic accuracy of zero-echo time MRI for the evaluation of cervical neural foraminal stenosis. Spine (Phila Pa 1976) 43:928\u2013933. https:\/\/doi.org\/10.1097\/brs.0000000000002462","journal-title":"Spine (Phila Pa 1976)"},{"key":"585_CR23","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1007\/s00256-022-04000-0","volume":"51","author":"JC Nguyen","year":"2022","unstructured":"Nguyen JC, Guariento A, Williams BA et al (2022) MRI evaluation of pediatric tibial eminence fractures: comparison between conventional and \u201cCT-like\u201d ultrashort echo time (UTE) images. Skeletal Radiol 51:1603\u20131610. https:\/\/doi.org\/10.1007\/s00256-022-04000-0","journal-title":"Skeletal Radiol"},{"key":"585_CR24","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1007\/s00256-021-03987-2","volume":"51","author":"UU Bharadwaj","year":"2022","unstructured":"Bharadwaj UU, Coy A, Motamedi D et al (2022) CT-like MRI: a qualitative assessment of ZTE sequences for knee osseous abnormalities. Skeletal Radiol 51:1585\u20131594. https:\/\/doi.org\/10.1007\/s00256-021-03987-2","journal-title":"Skeletal Radiol"},{"key":"585_CR25","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1186\/s13244-024-01751-3","volume":"15","author":"JM Getzmann","year":"2024","unstructured":"Getzmann JM, Deininger-Czermak E, Melissanidis S et al (2024) Deep learning-based pseudo-CT synthesis from zero echo time MR sequences of the pelvis. Insights Imaging 15:202. https:\/\/doi.org\/10.1186\/s13244-024-01751-3","journal-title":"Insights Imaging"},{"key":"585_CR26","doi-asserted-by":"publisher","first-page":"e231817","DOI":"10.1148\/radiol.231817","volume":"313","author":"FE Lecouvet","year":"2024","unstructured":"Lecouvet FE, Zan D, Lepot D et al (2024) MRI-based zero echo time and black bone pseudo-CT compared with whole-body CT to detect osteolytic lesions in multiple myeloma. Radiology 313:e231817. https:\/\/doi.org\/10.1148\/radiol.231817","journal-title":"Radiology"},{"key":"585_CR27","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1148\/radiol.2019181949","volume":"291","author":"C Messiou","year":"2019","unstructured":"Messiou C, Hillengass J, Delorme S et al (2019) Guidelines for acquisition, interpretation, and reporting of whole-body MRI in myeloma: Myeloma Response Assessment and Diagnosis System (MY-RADS). Radiology 291:5\u201313. https:\/\/doi.org\/10.1148\/radiol.2019181949","journal-title":"Radiology"},{"key":"585_CR28","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.diii.2018.12.005","volume":"100","author":"A Larbi","year":"2019","unstructured":"Larbi A, Omoumi P, Pasoglou V et al (2019) Comparison of bone lesion distribution between prostate cancer and multiple myeloma with whole-body MRI. Diagn Interv Imaging 100:295\u2013302. https:\/\/doi.org\/10.1016\/j.diii.2018.12.005","journal-title":"Diagn Interv Imaging"},{"key":"585_CR29","doi-asserted-by":"publisher","first-page":"2307","DOI":"10.1007\/s00256-022-04097-3","volume":"51","author":"L Wolharn","year":"2022","unstructured":"Wolharn L, Guggenberger R, Higashigaito K et al (2022) Detailed bone assessment of the sacroiliac joint in a prospective imaging study: comparison between computed tomography, zero echo time, and black bone magnetic resonance imaging. Skeletal Radiol 51:2307\u20132315. https:\/\/doi.org\/10.1007\/s00256-022-04097-3","journal-title":"Skeletal Radiol"},{"key":"585_CR30","doi-asserted-by":"publisher","first-page":"20160407","DOI":"10.1259\/dmfr.20160407","volume":"46","author":"KA Eley","year":"2017","unstructured":"Eley KA, Watt-Smith SR, Golding SJ et al (2017) Black bone MRI: a novel imaging technique for 3D printing. Dentomaxillofac Radiol 46:20160407. https:\/\/doi.org\/10.1259\/dmfr.20160407","journal-title":"Dentomaxillofac Radiol"},{"key":"585_CR31","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.diii.2019.07.011","volume":"101","author":"C Capelle","year":"2020","unstructured":"Capelle C, Devos P, Caudrelier C et al (2020) How reproducible are classical and new CT-pelvimetry measurements? Diagn Interv Imaging 101:79\u201389. https:\/\/doi.org\/10.1016\/j.diii.2019.07.011","journal-title":"Diagn Interv Imaging"},{"key":"585_CR32","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1037\/1082-989X.1.1.30","volume":"1","author":"K McGraw","year":"1996","unstructured":"McGraw K, Wong SP (1996) Forming inferences about some intraclass correlation coefficients. Psychological Methods 1:30\u201346. https:\/\/doi.org\/10.1037\/1082-989X.1.1.30","journal-title":"Psychological Methods"},{"key":"585_CR33","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1002\/uog.5256","volume":"31","author":"JW Bartlett","year":"2008","unstructured":"Bartlett JW, Frost C (2008) Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables. Ultrasound Obstet Gynecol 31:466\u2013475. https:\/\/doi.org\/10.1002\/uog.5256","journal-title":"Ultrasound Obstet Gynecol"},{"key":"585_CR34","doi-asserted-by":"publisher","first-page":"e56","DOI":"10.1016\/j.ejrad.2009.11.018","volume":"75","author":"U Korhonen","year":"2010","unstructured":"Korhonen U, Solja R, Laitinen J et al (2010) MR pelvimetry measurements, analysis of inter- and intra-observer variation. Eur J Radiol 75:e56\u2013e61. https:\/\/doi.org\/10.1016\/j.ejrad.2009.11.018","journal-title":"Eur J Radiol"},{"key":"585_CR35","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1007\/s00404-018-4814-5","volume":"298","author":"YG Li","year":"2018","unstructured":"Li YG, Chen CL, Liao KD et al (2018) Study on the cephalopelvic relationship with cephalic presentation in nulliparous full-term Chinese pregnant women by MRI with three-dimensional reconstruction. Arch Gynecol Obstet 298:433\u2013441. https:\/\/doi.org\/10.1007\/s00404-018-4814-5","journal-title":"Arch Gynecol Obstet"},{"key":"585_CR36","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ejogrb.2018.09.033","volume":"232","author":"AS Klemt","year":"2019","unstructured":"Klemt AS, Schulze S, Bruggmann D et al (2019) MRI-based pelvimetric measurements as predictors for a successful vaginal breech delivery in the Frankfurt Breech at term cohort (FRABAT). Eur J Obstet Gynecol Reprod Biol 232:10\u201317. https:\/\/doi.org\/10.1016\/j.ejogrb.2018.09.033","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"585_CR37","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00404-016-4276-6","volume":"295","author":"M Franz","year":"2017","unstructured":"Franz M, von Bismarck A, Delius M et al (2017) MR pelvimetry: prognosis for successful vaginal delivery in patients with suspected fetopelvic disproportion or breech presentation at term. Arch Gynecol Obstet 295:351\u2013359. https:\/\/doi.org\/10.1007\/s00404-016-4276-6","journal-title":"Arch Gynecol Obstet"},{"key":"585_CR38","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1148\/rg.220029","volume":"42","author":"U Aydingoz","year":"2022","unstructured":"Aydingoz U, Yildiz AE, Ergen FB et al (2022) Zero echo time musculoskeletal MRI: technique, optimization, applications, and pitfalls. Radiographics 42:1398\u20131414. https:\/\/doi.org\/10.1148\/rg.220029","journal-title":"Radiographics"},{"key":"585_CR39","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.ejogrb.2024.02.017","volume":"296","author":"P Shen","year":"2024","unstructured":"Shen P, Fu J, Zhang W et al (2024) A comparative study of two pelvimetry methods: 3D models based on CT and MRI. Eur J Obstet Gynecol Reprod Biol 296:286\u2013291. https:\/\/doi.org\/10.1016\/j.ejogrb.2024.02.017","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"585_CR40","doi-asserted-by":"publisher","unstructured":"Gatta G, Di Grezia G, Cuccurullo V et al (2021) MRI in pregnancy and precision medicine: a review from literature. J Pers Med 12. https:\/\/doi.org\/10.3390\/jpm12010009","DOI":"10.3390\/jpm12010009"},{"key":"585_CR41","unstructured":"International Electrotechnical Commission (2022) Medical electrical equipment: particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis. (4.0 edn. Vol. Medical electrical equipment). International Electrotechnical Commission"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00585-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-025-00585-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00585-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T12:43:18Z","timestamp":1747658598000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-025-00585-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,19]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["585"],"URL":"https:\/\/doi.org\/10.1186\/s41747-025-00585-y","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,19]]},"assertion":[{"value":"4 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study was approved by the institutional Ethics Committee of the Cliniques Universitaires Saint Luc in Brussels (2020\/27JUL\/380).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The institutional ethics committee does not require signed consent forms for retrospective studies. The current study employs imaging data from a previously published prospective cohort of female patients with suspected multiple myeloma (prospective oncology registered trial, ClinicalTrials.gov: NCT05381077). Written informed consent to participate had been obtained from all patients in the frame of this previous study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors declare that they have no financial or non-financial competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"52"}}