{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T06:19:56Z","timestamp":1794032396167,"version":"4.8.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100016670","name":"Region \u00d6sterg\u00f6tland","doi-asserted-by":"publisher","award":["R\u00d6-965126"],"award-info":[{"award-number":["R\u00d6-965126"]}],"id":[{"id":"10.13039\/100016670","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>We compared photon-counting detector computed tomography (PCD-CT) polyenergetic images, PCD-CT virtual monoenergetic images (VMI), and energy-integrating detector computed tomography (EID-CT) polyenergetic images regarding bone visualization and metal artifacts in patients with titanium wrist prostheses.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>After ethical approval, 15 patients were examined with PCD-CT and EID-CT. Polyenergetic images were reconstructed, as well as 130-keV VMI for PCD-CT. Five radiologists evaluated bone visualization, interpretability at metal-bone interface and metal artifacts using a 7-point ordinal scale. Streak artifacts and artifacts at the bone-metal interface were quantitatively assessed. Differences between image setups were analyzed using Friedman test and one-way ANOVA with <jats:italic>post hoc<\/jats:italic> tests.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Bone visualization was superior in PCD-CT polyenergetic images (median rating 6, range 3\u20137) compared with VMI (5, 3\u20137; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) and EID-CT (5, 3\u20137; <jats:italic>p<\/jats:italic>\u2009=\u20090.018). Streak artifacts were more pronounced with PCD-CT polyenergetic images (4, 3\u20136) compared with EID-CT (5, 4\u20136; <jats:italic>p<\/jats:italic>\u2009=\u20090.003) and PCD-CT VMI (5, 3\u20137; <jats:italic>p<\/jats:italic>\u2009=\u20090.002), with quantitative results showing least streak artifacts in PCD-CT VMI, followed by EID-CT and PCD-CT polyenergetic images (50\u2009\u00b1\u20097%, 70\u2009\u00b1\u20096%, and 79\u2009\u00b1\u20095%, respectively; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Interpretability at bone-metal interface was better with PCD-CT polyenergetic images (5, 2\u20137; <jats:italic>p<\/jats:italic>\u2009=\u20090.045) and EID-CT (5, 3\u20136; <jats:italic>p<\/jats:italic>\u2009=\u20090.018) compared with PCD-CT VMI (4, 2\u20136), without quantitative differences.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Streak artifacts from titanium wrist prostheses were reduced using 130-keV PCD-CT VMI, while bone visualization was highest using PCD-CT polyenergetic images.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Relevance statement<\/jats:title>\n            <jats:p>In patients with wrist implants, photon-counting detector CT allows for effective metal artifact reduction using virtual monoenergetic images and improved bone visualization using polyenergetic images. As polyenergetic images and VMI have different advantages, access to both image setups may benefit diagnostic evaluation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Key Points<\/jats:title>\n            <jats:p>\n              <jats:list list-type=\"bullet\">\n                <jats:list-item>\n                  <jats:p>Virtual monoenergetic images (VMI) presented a substantial reduction of metal streak artifacts.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Polyenergetic images exhibited better image quality for bone imaging compared with VMI.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>A combination of image reconstructions should be preferred depending on the diagnostic task.<\/jats:p>\n                <\/jats:list-item>\n              <\/jats:list>\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Graphical Abstract<\/jats:title>\n          <\/jats:sec>","DOI":"10.1186\/s41747-025-00587-w","type":"journal-article","created":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T07:58:49Z","timestamp":1746086329000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Assessment of metal artifacts from titanium wrist prostheses: photon-counting versus energy-integrating detector CT"],"prefix":"10.1186","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3986-9737","authenticated-orcid":false,"given":"Nina","family":"K\u00e4mmerling","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Farnebo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M\u00e5rten","family":"Sandstedt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald","family":"Booij","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anders","family":"Persson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Tesselaar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,1]]},"reference":[{"key":"587_CR1","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1177\/17531934231195689","volume":"49","author":"JAI Redfern","year":"2024","unstructured":"Redfern JAI, Mehta N, Farnebo S et al (2024) Complication rates and modes of short and medium-term failure in Motec total wrist arthroplasty: an international cohort study. J Hand Surg Eur Vol 49:27\u201333. https:\/\/doi.org\/10.1177\/17531934231195689","journal-title":"J Hand Surg Eur Vol"},{"key":"587_CR2","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1177\/17531934231203297","volume":"49","author":"MEH Boeckstyns","year":"2024","unstructured":"Boeckstyns MEH, Herzberg G (2024) Complications after total wrist arthroplasty. J Hand Surg Eur Vol 49:177\u2013187. https:\/\/doi.org\/10.1177\/17531934231203297","journal-title":"J Hand Surg Eur Vol"},{"key":"587_CR3","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1148\/rg.246045065","volume":"24","author":"JF Barrett","year":"2004","unstructured":"Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679\u20131691. https:\/\/doi.org\/10.1148\/rg.246045065","journal-title":"Radiographics"},{"key":"587_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2020.108970","volume":"127","author":"A Grandmougin","year":"2020","unstructured":"Grandmougin A, Bakour O, Villani N et al (2020) Metal artifact reduction for small metal implants on CT: which image reconstruction algorithm performs better? Eur J Radiol 127:108970. https:\/\/doi.org\/10.1016\/j.ejrad.2020.108970","journal-title":"Eur J Radiol"},{"key":"587_CR5","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1148\/rg.2018170102","volume":"38","author":"M Katsura","year":"2018","unstructured":"Katsura M, Sato J, Akahane M, Kunimatsu A, Abe O (2018) Current and novel techniques for metal artifact reduction at CT: practical guide for radiologists. Radiographics 38:450\u2013461. https:\/\/doi.org\/10.1148\/rg.2018170102","journal-title":"Radiographics"},{"key":"587_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111276","volume":"170","author":"M Selles","year":"2024","unstructured":"Selles M, van Osch JAC, Maas M, Boomsma MF, Wellenberg RHH (2024) Advances in metal artifact reduction in CT images: a review of traditional and novel metal artifact reduction techniques. Eur J Radiol 170:111276. https:\/\/doi.org\/10.1016\/j.ejrad.2023.111276","journal-title":"Eur J Radiol"},{"key":"587_CR7","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1148\/rg.273065087","volume":"27","author":"MJ Lee","year":"2007","unstructured":"Lee MJ, Kim S, Lee SA et al (2007) Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. Radiographics 27:791\u2013803. https:\/\/doi.org\/10.1148\/rg.273065087","journal-title":"Radiographics"},{"key":"587_CR8","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-81600-1","volume":"11","author":"AJ Vellarackal","year":"2021","unstructured":"Vellarackal AJ, Kaim AH (2021) Metal artefact reduction of different alloys with dual energy computed tomography (DECT). Sci Rep 11:2211. https:\/\/doi.org\/10.1038\/s41598-021-81600-1","journal-title":"Sci Rep"},{"key":"587_CR9","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1093\/rpd\/ncab105","volume":"195","author":"E Pettersson","year":"2021","unstructured":"Pettersson E, Back A, Thilander-Klang A (2021) Comparison of metal artefacts for different dual energy CT techniques. Radiat Prot Dosimetry 195:232\u2013245. https:\/\/doi.org\/10.1093\/rpd\/ncab105","journal-title":"Radiat Prot Dosimetry"},{"key":"587_CR10","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.ejrad.2018.08.010","volume":"107","author":"RHH Wellenberg","year":"2018","unstructured":"Wellenberg RHH, Hakvoort ET, Slump CH, Boomsma MF, Maas M, Streekstra GJ (2018) Metal artifact reduction techniques in musculoskeletal CT-imaging. Eur J Radiol 107:60\u201369. https:\/\/doi.org\/10.1016\/j.ejrad.2018.08.010","journal-title":"Eur J Radiol"},{"key":"587_CR11","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1097\/RLI.0000000000000535","volume":"54","author":"W Zhou","year":"2019","unstructured":"Zhou W, Bartlett DJ, Diehn FE et al (2019) Reduction of metal artifacts and improvement in dose efficiency using photon-counting detector computed tomography and tin filtration. Invest Radiol 54:204\u2013211. https:\/\/doi.org\/10.1097\/RLI.0000000000000535","journal-title":"Invest Radiol"},{"key":"587_CR12","doi-asserted-by":"publisher","first-page":"e14341","DOI":"10.1097\/MD.0000000000014341","volume":"98","author":"A Neroladaki","year":"2019","unstructured":"Neroladaki A, Martin SP, Bagetakos I et al (2019) Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging. Medicine (Baltimore) 98:e14341. https:\/\/doi.org\/10.1097\/MD.0000000000014341","journal-title":"Medicine"},{"key":"587_CR13","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.diii.2018.12.007","volume":"100","author":"J Greffier","year":"2019","unstructured":"Greffier J, Larbi A, Frandon J, Daviau PA, Beregi JP, Pereira F (2019) Influence of iterative reconstruction and dose levels on metallic artifact reduction: a phantom study within four CT systems. Diagn Interv Imaging 100:269\u2013277. https:\/\/doi.org\/10.1016\/j.diii.2018.12.007","journal-title":"Diagn Interv Imaging"},{"key":"587_CR14","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-35989-6","volume":"13","author":"YC Layer","year":"2023","unstructured":"Layer YC, Mesropyan N, Kupczyk PA et al (2023) Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT. Sci Rep 13:8955. https:\/\/doi.org\/10.1038\/s41598-023-35989-6","journal-title":"Sci Rep"},{"key":"587_CR15","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1007\/s00330-011-2062-1","volume":"21","author":"F Bamberg","year":"2011","unstructured":"Bamberg F, Dierks A, Nikolaou K, Reiser MF, Becker CR, Johnson TR (2011) Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation. Eur Radiol 21:1424\u20131429. https:\/\/doi.org\/10.1007\/s00330-011-2062-1","journal-title":"Eur Radiol"},{"key":"587_CR16","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.ejrad.2017.01.002","volume":"88","author":"RH Wellenberg","year":"2017","unstructured":"Wellenberg RH, Boomsma MF, van Osch JA et al (2017) Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses. Eur J Radiol 88:61\u201370. https:\/\/doi.org\/10.1016\/j.ejrad.2017.01.002","journal-title":"Eur J Radiol"},{"key":"587_CR17","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1097\/RLI.0000000000000789","volume":"56","author":"JP Grunz","year":"2021","unstructured":"Grunz JP, Huflage H, Heidenreich JF et al (2021) Image quality assessment for clinical cadmium telluride-based photon-counting computed tomography detector in cadaveric wrist imaging. Invest Radiol 56:785\u2013790. https:\/\/doi.org\/10.1097\/RLI.0000000000000789","journal-title":"Invest Radiol"},{"key":"587_CR18","doi-asserted-by":"publisher","first-page":"2930","DOI":"10.1007\/s00330-021-08441-4","volume":"32","author":"SJ Bette","year":"2022","unstructured":"Bette SJ, Braun FM, Haerting M et al (2022) Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT. Eur Radiol 32:2930\u20132936. https:\/\/doi.org\/10.1007\/s00330-021-08441-4","journal-title":"Eur Radiol"},{"key":"587_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110442","volume":"154","author":"N Kammerling","year":"2022","unstructured":"Kammerling N, Sandstedt M, Farnebo S, Persson A, Tesselaar E (2022) Assessment of image quality in photon-counting detector computed tomography of the wrist\u2014an ex vivo study. Eur J Radiol 154:110442. https:\/\/doi.org\/10.1016\/j.ejrad.2022.110442","journal-title":"Eur J Radiol"},{"key":"587_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110662","volume":"159","author":"R Booij","year":"2023","unstructured":"Booij R, Kammerling NF, Oei EHG, Persson A, Tesselaar E (2023) Assessment of visibility of bone structures in the wrist using normal and half of the radiation dose with photon-counting detector CT. Eur J Radiol 159:110662. https:\/\/doi.org\/10.1016\/j.ejrad.2022.110662","journal-title":"Eur J Radiol"},{"key":"587_CR21","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s00256-022-04117-2","volume":"52","author":"K Rajendran","year":"2023","unstructured":"Rajendran K, Baffour F, Powell G et al (2023) Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT. Skeletal Radiol 52:23\u201329. https:\/\/doi.org\/10.1007\/s00256-022-04117-2","journal-title":"Skeletal Radiol"},{"key":"587_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111383","volume":"173","author":"N Kammerling","year":"2024","unstructured":"Kammerling N, Tesselaar E, Booij R, Fornander L, Persson A, Farnebo S (2024) A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT. Eur J Radiol 173:111383. https:\/\/doi.org\/10.1016\/j.ejrad.2024.111383","journal-title":"Eur J Radiol"},{"key":"587_CR23","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1148\/rg.2019180115","volume":"39","author":"S Leng","year":"2019","unstructured":"Leng S, Bruesewitz M, Tao S et al (2019) Photon-counting detector CT: system design and clinical applications of an emerging technology. Radiographics 39:729\u2013743. https:\/\/doi.org\/10.1148\/rg.2019180115","journal-title":"Radiographics"},{"key":"587_CR24","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1097\/RLI.0000000000000980","volume":"58","author":"T Flohr","year":"2023","unstructured":"Flohr T, Schmidt B (2023) Technical basics and clinical benefits of photon-counting CT. Invest Radiol 58:441\u2013450. https:\/\/doi.org\/10.1097\/RLI.0000000000000980","journal-title":"Invest Radiol"},{"key":"587_CR25","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s41747-023-00335-y","volume":"7","author":"M Woisetschlager","year":"2023","unstructured":"Woisetschlager M, Booij R, Tesselaar E, Oei EHG, Schilcher J (2023) Improved visualization of the bone-implant interface and osseointegration in ex vivo acetabular cup implants using photon-counting detector CT. Eur Radiol Exp 7:19. https:\/\/doi.org\/10.1186\/s41747-023-00335-y","journal-title":"Eur Radiol Exp"},{"key":"587_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111209","volume":"170","author":"TS Patzer","year":"2024","unstructured":"Patzer TS, Grunz JP, Huflage H et al (2024) Ultra-high resolution photon-counting CT with tin prefiltration for bone-metal interface visualization. Eur J Radiol 170:111209. https:\/\/doi.org\/10.1016\/j.ejrad.2023.111209","journal-title":"Eur J Radiol"},{"key":"587_CR27","doi-asserted-by":"publisher","first-page":"9286","DOI":"10.1007\/s00330-023-09879-4","volume":"33","author":"J Schreck","year":"2023","unstructured":"Schreck J, Laukamp KR, Niehoff JH et al (2023) Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images. Eur Radiol 33:9286\u20139295. https:\/\/doi.org\/10.1007\/s00330-023-09879-4","journal-title":"Eur Radiol"},{"key":"587_CR28","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111110","volume":"168","author":"AS Bjorkman","year":"2023","unstructured":"Bjorkman AS, Malusek A, Gauffin H, Persson A, Koskinen SK (2023) Spectral photon-counting CT: image quality evaluation using a metal-containing bovine bone specimen. Eur J Radiol 168:111110. https:\/\/doi.org\/10.1016\/j.ejrad.2023.111110","journal-title":"Eur J Radiol"},{"key":"587_CR29","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-77904-3","volume":"10","author":"TD Do","year":"2020","unstructured":"Do TD, Sawall S, Heinze S et al (2020) A semi-automated quantitative comparison of metal artifact reduction in photon-counting computed tomography by energy-selective thresholding. Sci Rep 10:21099. https:\/\/doi.org\/10.1038\/s41598-020-77904-3","journal-title":"Sci Rep"},{"key":"587_CR30","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.21037\/qims.2020.04.03","volume":"10","author":"N Grosse Hokamp","year":"2020","unstructured":"Grosse Hokamp N, Eck B, Siedek F et al (2020) Quantification of metal artifacts in computed tomography: methodological considerations. Quant Imaging Med Surg 10:1033\u20131044. https:\/\/doi.org\/10.21037\/qims.2020.04.03","journal-title":"Quant Imaging Med Surg"},{"key":"587_CR31","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012","journal-title":"J Chiropr Med"},{"key":"587_CR32","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14386","volume":"25","author":"B Konst","year":"2024","unstructured":"Konst B, Ohlsson L, Henriksson L, Sandstedt M, Persson A, Ebbers T (2024) Optimization of photon counting CT for cardiac imaging in patients with left ventricular assist devices: an in-depth assessment of metal artifacts. J Appl Clin Med Phys 25:e14386. https:\/\/doi.org\/10.1002\/acm2.14386","journal-title":"J Appl Clin Med Phys"},{"key":"587_CR33","doi-asserted-by":"publisher","first-page":"350","DOI":"10.3390\/diagnostics14040350","volume":"14","author":"T Fukuda","year":"2024","unstructured":"Fukuda T, Yonenaga T, Akao R et al (2024) Comparison of bone evaluation and metal artifact between photon-counting CT and five energy-integrating-detector CT under standardized conditions using cadaveric forearms. Diagnostics (Basel) 14:350. https:\/\/doi.org\/10.3390\/diagnostics14040350","journal-title":"Diagnostics"},{"key":"587_CR34","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1097\/RLI.0000000000001058","volume":"59","author":"AA Marth","year":"2024","unstructured":"Marth AA, Goller SS, Kajdi GW, Marcus RP, Sutter R (2024) Photon-counting detector CT: clinical utility of virtual monoenergetic imaging combined with tin prefiltration to reduce metal artifacts in the postoperative ankle. Invest Radiol 59:545\u2013553. https:\/\/doi.org\/10.1097\/RLI.0000000000001058","journal-title":"Invest Radiol"},{"key":"587_CR35","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1186\/s41747-023-00354-9","volume":"7","author":"P Midthun","year":"2023","unstructured":"Midthun P, Kirkhus E, Osteras BH, Hoiness PR, England A, Johansen S (2023) Metal artifact reduction on musculoskeletal CT: a phantom and clinical study. Eur Radiol Exp 7:46. https:\/\/doi.org\/10.1186\/s41747-023-00354-9","journal-title":"Eur Radiol Exp"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00587-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-025-00587-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00587-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T20:02:45Z","timestamp":1746129765000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-025-00587-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,1]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["587"],"URL":"https:\/\/doi.org\/10.1186\/s41747-025-00587-w","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,1]]},"assertion":[{"value":"5 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Swedish Ethical Review Authority (Dnr. 2021-02034).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Patients eligible to participate received oral and written information about the study and were given the option to decline.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"SF provides consulting services for Swemac Innovation AB. RB has been, since February 2025, employed as Scientific Product Manager at Siemens Healthineers. The remaining authors declare no conflicts of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"45"}}