{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T02:54:01Z","timestamp":1781924041044,"version":"3.54.5"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,24]],"date-time":"2025-05-24T00:00:00Z","timestamp":1748044800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,24]],"date-time":"2025-05-24T00:00:00Z","timestamp":1748044800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000097","name":"National Center for Research Resources","doi-asserted-by":"publisher","award":["C06 RR018898"],"award-info":[{"award-number":["C06 RR018898"]}],"id":[{"id":"10.13039\/100000097","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"publisher","award":["R01 EB031790"],"award-info":[{"award-number":["R01 EB031790"]}],"id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Prostate imaging reporting and data system (PI-RADS) v2.1 guidelines for magnetic resonance imaging acquisition define a standard of 0.40\u2009mm\u2009\u00d7\u20090.70\u2009mm in-plane resolution (0.280\u2009mm<jats:sup>2<\/jats:sup> pixel area), but adherence has been challenging. We questioned if a modification of a PI-RADS-adherent T2-weighted (T2WI) sequence to one having equivalent pixel area could allow reduced acquisition time but provide improved diagnostic quality (DQ).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>An adherent T2WI sequence was modified by reducing the frequency sampling, thereby reducing the signal bandwidth (BW). This was compensated by increasing the phase sampling for an equivalent pixel area (0.50\u2009mm\u2009\u00d7\u20090.57\u2009mm\u2009=\u20090.285\u2009mm<jats:sup>2<\/jats:sup>). The BW reduction allowed a two-fold reduction in averaging, also enabling reduced acquisition time. The adherent and modified sequences were evaluated in phantoms and 62 consecutive prostate MRI subjects. Images were evaluated individually by four radiologists using a four-point DQ scale and using prostate imaging quality (PI-QUAL)v2. Each reviewer also indicated any sequence preference. The Wilcoxon test was used.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>In the phantom, mean signal-to-noise ratios were equivalent for the two sequences; superior frequency resolution for the adherent sequence, and superior phase resolution for the modified sequence were shown. Across 62 participants, the median acquisition time was reduced by 23%, from 3:55\u2009min:s to 3:01\u2009min:s. For all three means of comparison (DQ, PI-QUALv2, reader preference), the modified sequence was significantly superior (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.037).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Modification of the PI-RADS standard (0.40-mm frequency resolution) to an equivalent, more isotropic pixel area (0.28\u2009mm<jats:sup>2<\/jats:sup>) reduced acquisition time and improved image quality.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Relevance statement<\/jats:title>\n            <jats:p>Generalization of the PI-RADSv.2.1 minimum technical standard for T2WI in-plane resolution to be more isotropic preserves the targeted high resolution, allowing reduced acquisition time, also reducing motion sensitivity, and improving image quality. This approach may also reduce the need for rescanning poor-quality sequences.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Key Points<\/jats:title>\n            <jats:p>\n              <jats:list list-type=\"bullet\">\n                <jats:list-item>\n                  <jats:p>PI-RADSv2.1 suggests a standard T2WI sequence with 0.40\u2009\u00d7\u20090.70\u2009mm<jats:sup>2<\/jats:sup> in-plane resolution.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>A modified PI-RADSv.2.1-adherent T2WI sequence with equivalent but more isotropic pixel area (0.50\u2009\u00d7\u20090.57\u2009mm<jats:sup>2<\/jats:sup>) allowed reduced scan times by 23% and significantly improved DQ.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Superiority of the modified sequence appears due to reduced motion sensitivity.<\/jats:p>\n                <\/jats:list-item>\n              <\/jats:list>\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Graphical Abstract<\/jats:title>\n          <\/jats:sec>","DOI":"10.1186\/s41747-025-00595-w","type":"journal-article","created":{"date-parts":[[2025,5,24]],"date-time":"2025-05-24T05:06:21Z","timestamp":1748063181000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Improved image quality and reduced acquisition time in prostate T2-weighted spin-echo MRI using a modified PI-RADS-adherent sequence"],"prefix":"10.1186","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8045-910X","authenticated-orcid":false,"given":"Stephen J.","family":"Riederer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric A.","family":"Borisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam T.","family":"Froemming","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger C.","family":"Grimm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Hassanzadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akira","family":"Kawashima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoki","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,24]]},"reference":[{"key":"595_CR1","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1007\/s00330-011-2377-y","volume":"22","author":"JO Barentz","year":"2012","unstructured":"Barentz JO, Richenberg J, Clements R et al (2012) ESUR prostate MR guidelines 2012. Eur Radiol 22:746\u2013757. https:\/\/doi.org\/10.1007\/s00330-011-2377-y","journal-title":"Eur Radiol"},{"key":"595_CR2","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.eururo.2015.08.052","volume":"69","author":"JC Weinreb","year":"2016","unstructured":"Weinreb JC, Barentsz JO, Choyke PL et al (2016) PI-RADS prostate imaging-reporting and data system: 2015, version 2. Eur Urology 69:16\u201340. https:\/\/doi.org\/10.1016\/j.eururo.2015.08.052","journal-title":"Eur Urology"},{"key":"595_CR3","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.eururo.2019.02.033","volume":"76","author":"B Turkbey","year":"2019","unstructured":"Turkbey B, Rosenkrantz AB, Haider MA et al (2019) Prostate imaging reporting and data system version 2.1: 2019 update of prostate imaging reporting and data system version 2. Eur Urology 76:340\u2013351. https:\/\/doi.org\/10.1016\/j.eururo.2019.02.033","journal-title":"Eur Urology"},{"key":"595_CR4","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1002\/jmri.27546","volume":"54","author":"KJ Park","year":"2021","unstructured":"Park KJ, Choi SH, Kim M, Kim JK, Jeong IG (2021) Performance of prostate imaging reporting and data system version 2.1 for diagnosis of prostate cancer: a systematic review and meta-analysis. J Magn Reson Img 54:103\u2013112. https:\/\/doi.org\/10.1002\/jmri.27546","journal-title":"J Magn Reson Img"},{"key":"595_CR5","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.221309","volume":"307","author":"EC Yilmaz","year":"2023","unstructured":"Yilmaz EC, Shih JH, Belue MJ et al (2023) Prospective evaluation of PI-RADS version 2.1 for prostate cancer detection and investigation of multiparametric MRI-derive markers. Radiology 307:e221309. https:\/\/doi.org\/10.1148\/radiol.221309","journal-title":"Radiology"},{"key":"595_CR6","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.233337","volume":"312","author":"B Oerther","year":"2024","unstructured":"Oerther B, Nedelcu A, Engel H et al (2024) Update on PI-RADS version 2.1 diagnostic performance benchmarks for prostate MRI: systematic review and meta-analysis. Radiology 312:e233337. https:\/\/doi.org\/10.1148\/radiol.233337","journal-title":"Radiology"},{"key":"595_CR7","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/S0140-6736(16)32401-1","volume":"389","author":"HU Ahmed","year":"2017","unstructured":"Ahmed HU, Bosaily AE-S, Brown LC et al (2017) Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study. Lancet 389:815\u2013822. https:\/\/doi.org\/10.1016\/S0140-6736(16)32401-1","journal-title":"Lancet"},{"key":"595_CR8","doi-asserted-by":"publisher","first-page":"1767","DOI":"10.1056\/NEJMoa1801993","volume":"378","author":"V Kasivisvanathan","year":"2018","unstructured":"Kasivisvanathan V, Ranikko AS, Borghi M et al (2018) MRI-targeted or standard biopsy for prostate-cancer diagnosis. N Engl J Med 378:1767\u20131777. https:\/\/doi.org\/10.1056\/NEJMoa1801993","journal-title":"N Engl J Med"},{"key":"595_CR9","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.acra.2017.08.013","volume":"25","author":"SJ Esses","year":"2018","unstructured":"Esses SJ, Taneja SS, Rosenkrantz AB (2018) Imaging facilities\u2019 adherence to PI-RADS v2 minimum technical standards for the performance of prostate MRI. Acad Radiol 25:188\u2013195. https:\/\/doi.org\/10.1016\/j.acra.2017.08.013","journal-title":"Acad Radiol"},{"key":"595_CR10","doi-asserted-by":"publisher","first-page":"108662","DOI":"10.1016\/j.ejrad.2019.10866","volume":"120","author":"R Cuocolo","year":"2019","unstructured":"Cuocolo R, Stanzione A, Ponsiglione A et al (2019) Prostate MRI technical parameters standardization: a systematic review on adherence to PI-RADSv2 acquisition protocol. Eur J Radiol 120:108662. https:\/\/doi.org\/10.1016\/j.ejrad.2019.10866","journal-title":"Eur J Radiol"},{"key":"595_CR11","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.acra.2020.01.031","volume":"28","author":"JS Sackett","year":"2021","unstructured":"Sackett JS, Shih JH, Reese SE et al (2021) Quality of prostate MRI: Is the PI-RADS standard sufficient? Acad Radiol 28:199\u2013207. https:\/\/doi.org\/10.1016\/j.acra.2020.01.031","journal-title":"Acad Radiol"},{"key":"595_CR12","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.231130","volume":"309","author":"F Giganti","year":"2023","unstructured":"Giganti F, Ng A, Asif A et al (2023) Global variation in magnetic resonance imaging quality of the prostate. Radiology 309:e231130. https:\/\/doi.org\/10.1148\/radiol.231130","journal-title":"Radiology"},{"key":"595_CR13","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1118\/1.596503","volume":"17","author":"DL Parker","year":"1990","unstructured":"Parker DL, Gullberg GT (1990) Signal-to-noise efficiency in magnetic resonance imaging. Med Phys 17:250\u2013257","journal-title":"Med Phys"},{"key":"595_CR14","doi-asserted-by":"publisher","first-page":"3387","DOI":"10.1007\/s00330-023-10345-4","volume":"34","author":"H Nakai","year":"2024","unstructured":"Nakai H, Takahashi H, Adamo DA et al (2024) Decreased prostate MRI cancer detection rate due to moderate to severe susceptibility artifacts from hip prosthesis. Eur Radiol 34:3387\u20133399. https:\/\/doi.org\/10.1007\/s00330-023-10345-4","journal-title":"Eur Radiol"},{"key":"595_CR15","doi-asserted-by":"publisher","first-page":"2215","DOI":"10.1002\/jmri.29031","volume":"59","author":"Y Lin","year":"2024","unstructured":"Lin Y, Belue MJ, Yilmaz EC et al (2024) Deep learning-based T2-weighted MR image quality assessment and its impact on prostate cancer detection rates. J Magn Reson Img 59:2215\u20132223. https:\/\/doi.org\/10.1002\/jmri.29031","journal-title":"J Magn Reson Img"},{"key":"595_CR16","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1002\/(SICI)1522-2594(199911)42","volume":"42","author":"JG Pipe","year":"1999","unstructured":"Pipe JG (1999) Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 42:963\u2013969. https:\/\/doi.org\/10.1002\/(SICI)1522-2594(199911)42","journal-title":"Magn Reson Med"},{"key":"595_CR17","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1007\/s00261-014-0225-7","volume":"40","author":"AB Rosenkrantz","year":"2015","unstructured":"Rosenkrantz AB, Bennett GL, Doshi AM, Deng F-M, Babb JS, Taneja SS (2015) T2-weighted imaging of the prostate: impact of the BLADE technique on image quality and tumor assessment. Abdom Imaging 40:552\u2013559. https:\/\/doi.org\/10.1007\/s00261-014-0225-7","journal-title":"Abdom Imaging"},{"key":"595_CR18","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1007\/s00330-017-4949-y","volume":"28","author":"M Meier-Schroers","year":"2018","unstructured":"Meier-Schroers M, Mars C, Schmeel FC et al (2018) Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: imapct on lesion detection and PI-RADS classification. Eur J Radiol 28:24\u201330. https:\/\/doi.org\/10.1007\/s00330-017-4949-y","journal-title":"Eur J Radiol"},{"key":"595_CR19","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1016\/j.euo2020.06.007","volume":"3","author":"F Giganti","year":"2020","unstructured":"Giganti F, Allen C, Emberton M, Moore CM, Kasivisvanathan V (2020) Prostate imaging quality (PI-QUAL): a new quality control scoring system for multiparametric magnetic resonance imaging of the prostate from the PRECISION trial. Eur Urol Oncology 3:615\u2013619. https:\/\/doi.org\/10.1016\/j.euo2020.06.007","journal-title":"Eur Urol Oncology"},{"key":"595_CR20","doi-asserted-by":"publisher","first-page":"7068","DOI":"10.1007\/s00330-024-10795-4","volume":"34","author":"M de Rooij","year":"2024","unstructured":"de Rooij M, Allen C, Twilt JJ et al (2024) PI-QUAL version 2: an update of a standardised scoring system for the assessment of image quality of prostate MRI. Eur Radiol 34:7068\u20137079. https:\/\/doi.org\/10.1007\/s00330-024-10795-4","journal-title":"Eur Radiol"},{"key":"595_CR21","doi-asserted-by":"publisher","first-page":"3378","DOI":"10.1007\/s00261-021-02964-6","volume":"46","author":"X Wang","year":"2021","unstructured":"Wang X, Ma J, Bhosale P et al (2021) Novel deep learning-based noise reduction technique for prostate magnetic resonance imaging. Abdom Radiol (NY) 46:3378\u20133386. https:\/\/doi.org\/10.1007\/s00261-021-02964-6","journal-title":"Abdom Radiol (NY)"},{"key":"595_CR22","doi-asserted-by":"publisher","first-page":"1734","DOI":"10.1002\/jmri.27992","volume":"55","author":"JC Park","year":"2022","unstructured":"Park JC, Park EJ, Park MY, Kim M, Kim JK (2022) Fast T2-weighted imaging with deep learning-based reconstruction: evaluation of image quality and diagnostic performance in patients undergoing radical prostatectomy. J Magn Reson Imaging 55:1734\u20131744. https:\/\/doi.org\/10.1002\/jmri.27992","journal-title":"J Magn Reson Imaging"},{"key":"595_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111017","volume":"166","author":"K-L Lee","year":"2023","unstructured":"Lee K-L, Kessler DA, Dezonie S et al (2023) Assessment of deep learning-based reconstruction on T2-weighted and diffusion-weighted prostate MR image quality. Eur J Radiol 166:111017. https:\/\/doi.org\/10.1016\/j.ejrad.2023.111017","journal-title":"Eur J Radiol"},{"key":"595_CR24","doi-asserted-by":"publisher","first-page":"2921","DOI":"10.1007\/s00261-024-04256-1","volume":"49","author":"SJ Riederer","year":"2024","unstructured":"Riederer SJ, Borisch EA, Froemming AT, Kawashima A, Takahashi N (2024) Comparison of model-based versus deep learning-based reconstruction for thin-slice T2-weighted spin-echo prostate MRI. Abdom Radiol (NY)49:2921\u20132931. https:\/\/doi.org\/10.1007\/s00261-024-04256-1","journal-title":"Abdom Radiol (NY)"},{"key":"595_CR25","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1002\/jmri.1880040517","volume":"4","author":"YP Du","year":"1994","unstructured":"Du YP, Parker DL, Davis WL, Cao G (1994) Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography. J Magn Reson Imaging 4:733\u2013741. https:\/\/doi.org\/10.1002\/jmri.1880040517","journal-title":"J Magn Reson Imaging"},{"key":"595_CR26","doi-asserted-by":"publisher","first-page":"2537","DOI":"10.1002\/mrm.28315","volume":"84","author":"S Kargar","year":"2020","unstructured":"Kargar S, Borisch EA, Froemming AT et al (2020) Modified acquisition strategy for reduced motion artifact in super resolution T2FSE multislice MRI: application to prostate. Magn Reson Med 84:2537\u20132550. https:\/\/doi.org\/10.1002\/mrm.28315","journal-title":"Magn Reson Med"},{"key":"595_CR27","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1002\/jmri.20969","volume":"26","author":"O Dietrich","year":"2007","unstructured":"Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375\u2013385. https:\/\/doi.org\/10.1002\/jmri.20969","journal-title":"J Magn Reson Imaging"},{"key":"595_CR28","doi-asserted-by":"publisher","unstructured":"Gloe JN, Borisch EA, Froemming AT et al (2025) Deep learning for quality assessment of T2-weighted spin-echo prostate MRI: a tool to reduce unnecessary scanning time. Eur Radiol Exp. https:\/\/doi.org\/10.1186\/s417025-00584-z","DOI":"10.1186\/s417025-00584-z"},{"key":"595_CR29","unstructured":"Rosner B (2006) Fundamentals of biostatistics. Thomson, Belmont, pp 868"},{"key":"595_CR30","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1037\/h0026256","volume":"70","author":"J Cohen","year":"1968","unstructured":"Cohen J (1968) Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit. Psych Bull 70:213\u2013220. https:\/\/doi.org\/10.1037\/h0026256","journal-title":"Psych Bull"},{"key":"595_CR31","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1111\/j.1468-2958.2004.tb00738.x","volume":"30","author":"K Krippendorf","year":"2004","unstructured":"Krippendorf K (2004) Reliability in content analysis: some common misconceptions and recommendations. Human Comm Res 30:411\u2013433. https:\/\/doi.org\/10.1111\/j.1468-2958.2004.tb00738.x","journal-title":"Human Comm Res"},{"key":"595_CR32","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","volume":"17","author":"P Virtanen","year":"2020","unstructured":"Virtanen P, Gommers R, Oliphant TE et al (2020) ScyPy 1.0 fundamental algorithms for scientific computing in Python. Nat Methods 17:261\u2013272. https:\/\/doi.org\/10.1038\/s41592-019-0686-2","journal-title":"Nat Methods"},{"key":"595_CR33","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174. https:\/\/doi.org\/10.2307\/2529310","journal-title":"Biometrics"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00595-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-025-00595-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00595-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,24]],"date-time":"2025-05-24T05:06:22Z","timestamp":1748063182000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-025-00595-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,24]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["595"],"URL":"https:\/\/doi.org\/10.1186\/s41747-025-00595-w","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,24]]},"assertion":[{"value":"5 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This work was done under Institutional Review Board approval (#15-000829), under which the need for participants to provide written informed consent was waived.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"There is no data including images attributable to a specific individual. Per institutional policy, all subjects were given the option to make their anonymized medical records available for research purposes, including publication, and all subjects opted to do so.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"55"}}