{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T00:51:36Z","timestamp":1759971096617,"version":"build-2065373602"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T00:00:00Z","timestamp":1759881600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T00:00:00Z","timestamp":1759881600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004563","name":"Bayerisches Staatsministerium f\u00fcr Bildung und Kultus, Wissenschaft und Kunst","doi-asserted-by":"publisher","award":["bidt Postdoc-Graduate Center"],"award-info":[{"award-number":["bidt Postdoc-Graduate Center"]}],"id":[{"id":"10.13039\/501100004563","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Maximum intensity projections (MIPs) facilitate rapid lesion detection both for contrast-enhanced (CE) and diffusion-weighted imaging (DWI) breast magnetic resonance imaging (MRI). We evaluated the feasibility of AI-based virtual CE subtraction MIPs as a reading approach.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and methods<\/jats:title>\n            <jats:p>This Institutional Review Board-approved retrospective study includes 540 multi-parametric breast MRI examinations (performed from 2017 to 2020), including multi-<jats:italic>b<\/jats:italic>-value DWI (50, 750, and 1,500\u2009s\/mm\u00b2). A 2D U-Net was trained using unenhanced (UnE) images as inputs to generate virtual abbreviated CE (VAbCE) subtractions. Two radiologists evaluated lesion suspicion, image quality, and artifacts for UnE, VACE, and abbreviated CE (AbCE) images. Lesion conspicuity was compared between VAbCE and AbCE MIPs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Cancer detection rates for UE, VAbCE, and AbCE MIPs were 90.0%, 91.4%, and 94.3%, respectively. Single-slice reading demonstrated sensitivities of 88.6% (UnE), 91.4% (VAbCE), and 94.3% (AbCE). Inter-rater agreement (Cohen \u03ba) for lesion suspicion scores was higher for VAbCE (0.53) than UnE alone (0.39) and comparable to AbCE (0.58). No significant difference in mean lesion conspicuity was observed for VACE MIPs compared to ACE (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.670). No significant difference could be observed for quality (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.108), and reading time (<jats:italic>p<\/jats:italic>\u2009=\u20091.000) between methods. Fewer visually significant artifacts could be observed in VAbCE than in AbCE MIPs (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>VAbCE breast MRI improved inter-rater agreement and allowed for slightly improved sensitivity compared to UnE images, while AbCE still provided the overall highest sensitivity. Further research is necessary to investigate the diagnostic potential of VAbCE breast MRI.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Relevance statement<\/jats:title>\n            <jats:p>VAbCE breast MRI generated by neural networks allowed the derivation of MIPs for rapid visual assessment, showing a way for screening applications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Key Points<\/jats:title>\n            <jats:p>\n              <jats:list list-type=\"bullet\">\n                <jats:list-item>\n                  <jats:p>Virtual abbreviated contrast-enhanced (VAbCE) MIPs provided comparable sensitivity to MIPs of unenhanced high <jats:italic>b<\/jats:italic>-value DWI and were slightly lower than AbCE MIPs.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Adding VAbCE to unenhanced high <jats:italic>b<\/jats:italic>-value DWI significantly improved interrater agreement for lesion suspicion scoring.<\/jats:p>\n                <\/jats:list-item>\n                <jats:list-item>\n                  <jats:p>Single-slice evaluation of VAbCE MIPs provided a sensitivity comparable to unenhanced high <jats:italic>b<\/jats:italic>-value DWI MIPs.<\/jats:p>\n                <\/jats:list-item>\n              <\/jats:list>\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Graphical Abstract<\/jats:title>\n          <\/jats:sec>","DOI":"10.1186\/s41747-025-00625-7","type":"journal-article","created":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T12:21:57Z","timestamp":1759926117000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Virtual contrast-enhanced maximum intensity projections from high-b-value diffusion-weighted breast MRI: a feasibility study"],"prefix":"10.1186","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8450-3021","authenticated-orcid":false,"given":"Andrzej","family":"Liebert","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hannes","family":"Schreiter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominique","family":"Hadler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenz A.","family":"Kapsner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabine","family":"Ohlmeyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica","family":"Eberle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramona","family":"Erber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julius","family":"Emons","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frederik B.","family":"Laun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Uder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evelyn","family":"Wenkel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Bickelhaupt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,8]]},"reference":[{"key":"625_CR1","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1148\/radiol.2016161444","volume":"283","author":"CK Kuhl","year":"2017","unstructured":"Kuhl CK, Strobel K, Bieling H, Leutner C, Schild HH, Schrading S (2017) Supplemental breast MR imaging screening of women with average risk of breast cancer. Radiology 283:361\u2013370. https:\/\/doi.org\/10.1148\/radiol.2016161444","journal-title":"Radiology"},{"key":"625_CR2","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1148\/radiol.2442060461","volume":"244","author":"CD Lehman","year":"2007","unstructured":"Lehman CD, Isaacs C, Schnall MD et al (2007) Cancer yield of mammography, MR, and us in high-risk women: prospective multi-institution breast cancer screening study. Radiology 244:381\u2013388. https:\/\/doi.org\/10.1148\/radiol.2442060461","journal-title":"Radiology"},{"key":"625_CR3","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1002\/jmri.26654","volume":"50","author":"RM Mann","year":"2019","unstructured":"Mann RM, Kuhl CK, Moy L (2019) Contrast-enhanced MRI for breast cancer screening. J Magn Reson Imaging 50:377\u2013390. https:\/\/doi.org\/10.1002\/jmri.26654","journal-title":"J Magn Reson Imaging"},{"key":"625_CR4","doi-asserted-by":"publisher","first-page":"djv349","DOI":"10.1093\/jnci\/djv349","volume":"108","author":"CD Lehman","year":"2016","unstructured":"Lehman CD, Lee JM, DeMartini WB et al (2016) Screening MRI in women with a personal history of breast cancer. J Natl Cancer Inst 108:djv349. https:\/\/doi.org\/10.1093\/jnci\/djv349","journal-title":"J Natl Cancer Inst"},{"key":"625_CR5","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1148\/radiol.2019182947","volume":"292","author":"RM Mann","year":"2019","unstructured":"Mann RM, Cho N, Moy L (2019) Breast MRI: state of the art. Radiology 292:520\u2013536. https:\/\/doi.org\/10.1148\/radiol.2019182947","journal-title":"Radiology"},{"key":"625_CR6","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1055\/a-1483-2782","volume":"81","author":"M Untch","year":"2021","unstructured":"Untch M, Fasching PA, Brucker SY et al (2021) Treatment of patients with early breast cancer: evidence, controversies, consensus: German expert opinions on the 17th international St. Gallen consensus conference. Geburtshilfe Frauenheilkd 81:637\u2013653. https:\/\/doi.org\/10.1055\/a-1483-2782","journal-title":"Geburtshilfe Frauenheilkd"},{"key":"625_CR7","doi-asserted-by":"publisher","first-page":"2304","DOI":"10.1200\/jco.2013.52.5386","volume":"32","author":"CK Kuhl","year":"2014","unstructured":"Kuhl CK, Schrading S, Strobel K, Schild HH, Hilgers R-D, Bieling HB (2014) Abbreviated breast magnetic resonance imaging (MRI): first postcontrast subtracted images and maximum-intensity projection\u2014a novel approach to breast cancer screening with MRI. J Clin Oncol 32:2304\u20132310. https:\/\/doi.org\/10.1200\/jco.2013.52.5386","journal-title":"J Clin Oncol"},{"key":"625_CR8","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1148\/radiol.2021202927","volume":"299","author":"M-R Kwon","year":"2021","unstructured":"Kwon M-R, Choi JS, Won H et al (2021) Breast cancer screening with abbreviated breast MRI: 3-year outcome analysis. Radiology 299:73\u201383. https:\/\/doi.org\/10.1148\/radiol.2021202927","journal-title":"Radiology"},{"key":"625_CR9","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1148\/radiol.2019182789","volume":"293","author":"N Amornsiripanitch","year":"2019","unstructured":"Amornsiripanitch N, Bickelhaupt S, Shin HJ et al (2019) Diffusion-weighted MRI for unenhanced breast cancer screening. Radiology 293:504\u2013520. https:\/\/doi.org\/10.1148\/radiol.2019182789","journal-title":"Radiology"},{"key":"625_CR10","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1148\/radiol.2015150425","volume":"278","author":"S Bickelhaupt","year":"2016","unstructured":"Bickelhaupt S, Laun FB, Tesdorff J et al (2016) Fast and noninvasive characterization of suspicious lesions detected at breast cancer x-ray screening: capability of diffusion-weighted MR imaging with MIPS. Radiology 278:689\u2013697. https:\/\/doi.org\/10.1148\/radiol.2015150425","journal-title":"Radiology"},{"key":"625_CR11","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.mri.2024.01.005","volume":"107","author":"SA Christner","year":"2024","unstructured":"Christner SA, Grunz JP, Schlai\u00df T et al (2024) Breast lesion morphology assessment with high and standard b values in diffusion-weighted imaging at 3 Tesla. Magn Reson Imaging 107:100\u2013110. https:\/\/doi.org\/10.1016\/j.mri.2024.01.005","journal-title":"Magn Reson Imaging"},{"key":"625_CR12","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2021.792516","volume":"11","author":"P Wang","year":"2021","unstructured":"Wang P, Nie P, Dang Y et al (2021) Synthesizing the first phase of dynamic sequences of breast MRI for enhanced lesion identification. Front Oncol 11:792516. https:\/\/doi.org\/10.3389\/fonc.2021.792516","journal-title":"Front Oncol"},{"key":"625_CR13","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.213199","volume":"306","author":"M Chung","year":"2023","unstructured":"Chung M, Calabrese E, Mongan J et al (2023) Deep learning to simulate contrast-enhanced breast MRI of invasive breast cancer. Radiology 306:e213199. https:\/\/doi.org\/10.1148\/radiol.213199","journal-title":"Radiology"},{"key":"625_CR14","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222211","volume":"307","author":"G Muller-Franzes","year":"2023","unstructured":"Muller-Franzes G, Huck L, Tayebi Arasteh S et al (2023) Using machine learning to reduce the need for contrast agents in breast MRI through synthetic images. Radiology 307:e222211. https:\/\/doi.org\/10.1148\/radiol.222211","journal-title":"Radiology"},{"key":"625_CR15","doi-asserted-by":"publisher","unstructured":"Zhang T, Han L, D\u2019Angelo A et al (2023) Synthesis of contrast-enhanced breast MRI using T1- and multi-b-value DWI-based hierarchical fusion network with attention mechanism. In: Medical image computing and computer assisted intervention\u2014MICCAI 2023. Springer, Cham, pp 79\u201388. Available via https:\/\/doi.org\/10.1007\/978-3-031-43990-2_8","DOI":"10.1007\/978-3-031-43990-2_8"},{"key":"625_CR16","doi-asserted-by":"publisher","unstructured":"Liebert A, Schreiter H, Kapsner LA et al (2024) Impact of non-contrast-enhanced imaging input sequences on the generation of virtual contrast-enhanced breast MRI scans using neural network. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-024-11142-3","DOI":"10.1007\/s00330-024-11142-3"},{"key":"625_CR17","doi-asserted-by":"publisher","unstructured":"Osuala R, Lang DM, Verma P et al (2024) Towards learning contrast kinetics with multi-condition latent diffusion models. In: International conference on medical image computing and computer-assisted intervention. Springer, Cham, pp 713\u2013723. Available via https:\/\/doi.org\/10.1007\/978-3-031-72086-4_67","DOI":"10.1007\/978-3-031-72086-4_67"},{"key":"625_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.inffus.2024.102381","volume":"108","author":"T Zhang","year":"2024","unstructured":"Zhang T, Tan T, Han L et al (2024) IMPORTANT-Net: integrated MRI multi-parametric increment fusion generator with attention network for synthesizing absent data. Inf Fusion 108:102381. https:\/\/doi.org\/10.1016\/j.inffus.2024.102381","journal-title":"Inf Fusion"},{"key":"625_CR19","doi-asserted-by":"publisher","unstructured":"George A, Schreiter H, Hossbach J et al (2025) U-Net and GAN for virtual contrast in breast MRI. In: Bildverarbeitung f\u00fcr die Medizin 2025: Proceedings, German conference on medical image computing, Regensburg, 9\u201311 March 2025. Springer, p 277. https:\/\/doi.org\/10.1007\/978-3-658-47422-5_63","DOI":"10.1007\/978-3-658-47422-5_63"},{"key":"625_CR20","doi-asserted-by":"publisher","first-page":"1232","DOI":"10.1002\/jmri.29528","volume":"61","author":"P Wang","year":"2025","unstructured":"Wang P, Wang H, Nie P et al (2025) Enabling AI-generated content for gadolinium-free contrast-enhanced breast magnetic resonance imaging. J Magn Reson Imaging 61:1232\u20131243. https:\/\/doi.org\/10.1002\/jmri.29528","journal-title":"J Magn Reson Imaging"},{"key":"625_CR21","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1186\/s41747-024-00451-3","volume":"8","author":"G Muller-Franzes","year":"2024","unstructured":"Muller-Franzes G, Huck L, Bode M et al (2024) Diffusion probabilistic versus generative adversarial models to reduce contrast agent dose in breast MRI. Eur Radiol Exp 8:53. https:\/\/doi.org\/10.1186\/s41747-024-00451-3","journal-title":"Eur Radiol Exp"},{"key":"625_CR22","doi-asserted-by":"publisher","unstructured":"Schreiter H, Eberle J, Kapsner LA et al (2024) Virtual dynamic contrast enhanced breast MRI using 2D U-Net architectures. In: Deep breast workshop on AI and imaging for diagnostic and treatment challenges in breast care. Springer, Cham, pp 85\u201395. https:\/\/doi.org\/10.1007\/978-3-031-77789-9_9","DOI":"10.1007\/978-3-031-77789-9_9"},{"key":"625_CR23","doi-asserted-by":"publisher","first-page":"S22014","DOI":"10.1117\/1.JMI.12.S2.S22014","volume":"12","author":"R Osuala","year":"2025","unstructured":"Osuala R, Joshi S, Tsirikoglou A et al (2025) Simulating dynamic tumor contrast enhancement in breast MRI using conditional generative adversarial networks. J Med Imaging 12:S22014\u2013S22014","journal-title":"J Med Imaging"},{"key":"625_CR24","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/j.ejrad.2006.08.036","volume":"61","author":"AA Tardivon","year":"2007","unstructured":"Tardivon AA, Athanasiou A, Thibault F, El Khoury C (2007) Breast imaging and reporting data system (BIRADS): magnetic resonance imaging. Eur J Radiol 61:212\u2013215. https:\/\/doi.org\/10.1016\/j.ejrad.2006.08.036","journal-title":"Eur J Radiol"},{"key":"625_CR25","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1097\/rli.0000000000000784","volume":"56","author":"S Ohlmeyer","year":"2021","unstructured":"Ohlmeyer S, Laun FB, Bickelhaupt S et al (2021) Ultra-high b-value diffusion-weighted imaging-based abbreviated protocols for breast cancer detection. Invest Radiol 56:629\u2013636. https:\/\/doi.org\/10.1097\/rli.0000000000000784","journal-title":"Invest Radiol"},{"key":"625_CR26","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J et al (2012) 3D Slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30:1323\u20131341. https:\/\/doi.org\/10.1016\/j.mri.2012.05.001","journal-title":"Magn Reson Imaging"},{"key":"625_CR27","doi-asserted-by":"publisher","first-page":"5997","DOI":"10.1007\/s00330-022-08626-5","volume":"32","author":"LA Kapsner","year":"2022","unstructured":"Kapsner LA, Ohlmeyer S, Folle L et al (2022) Automated artifact detection in abbreviated dynamic contrast-enhanced (DCE) MRI-derived maximum intensity projections (MIPS) of the breast. Eur Radiol 32:5997\u20136007. https:\/\/doi.org\/10.1007\/s00330-022-08626-5","journal-title":"Eur Radiol"},{"key":"625_CR28","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-37342-3","volume":"13","author":"LA Kapsner","year":"2023","unstructured":"Kapsner LA, Balbach EL, Folle L et al (2023) Image quality assessment using deep learning in high b-value diffusion-weighted breast MRI. Sci Rep 13:10549. https:\/\/doi.org\/10.1038\/s41598-023-37342-3","journal-title":"Sci Rep"},{"key":"625_CR29","doi-asserted-by":"publisher","first-page":"4752","DOI":"10.1007\/s00330-023-10469-7","volume":"34","author":"A Liebert","year":"2024","unstructured":"Liebert A, Das BK, Kapsner LA et al (2024) Smart forecasting of artifacts in contrast-enhanced breast MRI before contrast agent administration. Eur Radiol 34:4752\u20134763. https:\/\/doi.org\/10.1007\/s00330-023-10469-7","journal-title":"Eur Radiol"},{"key":"625_CR30","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/s41747-025-00580-3","volume":"9","author":"A Liebert","year":"2025","unstructured":"Liebert A, Hadler D, Ehring C et al (2025) Feasibility of virtual T2-weighted fat-saturated breast MRI images by convolutional neural networks. Eur Radiol Exp 9:47. https:\/\/doi.org\/10.1186\/s41747-025-00580-3","journal-title":"Eur Radiol Exp"},{"key":"625_CR31","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1002\/jmri.22078","volume":"31","author":"SC Partridge","year":"2010","unstructured":"Partridge SC, DeMartini WB, Kurland BF, Eby PR, White SW, Lehman CD (2010) Differential diagnosis of mammographically and clinically occult breast lesions on diffusion-weighted MRI. J Magn Reson Imaging 31:562\u2013570. https:\/\/doi.org\/10.1002\/jmri.22078","journal-title":"J Magn Reson Imaging"},{"key":"625_CR32","doi-asserted-by":"publisher","first-page":"607","DOI":"10.3390\/diagnostics13040607","volume":"13","author":"D Hausmann","year":"2023","unstructured":"Hausmann D, Todorski I, Pindur A et al (2023) Advanced diffusion-weighted imaging sequences for breast MRI: comprehensive comparison of improved sequences and ultra-high b-values to identify the optimal combination. Diagnostics (Basel) 13:607. https:\/\/doi.org\/10.3390\/diagnostics13040607","journal-title":"Diagnostics (Basel)"},{"key":"625_CR33","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/j.mri.2015.06.002","volume":"33","author":"M Telegrafo","year":"2015","unstructured":"Telegrafo M, Rella L, Stabile Ianora AA, Angelelli G, Moschetta M (2015) Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): an accurate and alternative strategy for detecting and differentiating breast lesions. Magn Reson Imaging 33:951\u2013955. https:\/\/doi.org\/10.1016\/j.mri.2015.06.002","journal-title":"Magn Reson Imaging"},{"key":"625_CR34","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1177\/0284185120912408","volume":"62","author":"LA Carbonaro","year":"2021","unstructured":"Carbonaro LA, Schiaffino S, Clauser P et al (2021) Side of contrast injection and breast size correlate with motion artifacts grade and image quality on breast MRI. Acta Radiol 62:19\u201326. https:\/\/doi.org\/10.1177\/0284185120912408","journal-title":"Acta Radiol"},{"key":"625_CR35","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1177\/0284185118770918","volume":"60","author":"P Clauser","year":"2019","unstructured":"Clauser P, Dietzel M, Weber M, Kaiser CG, Baltzer PA (2019) Motion artifacts, lesion type, and parenchymal enhancement in breast MRI: what does really influence diagnostic accuracy? Acta Radiol 60:19\u201327. https:\/\/doi.org\/10.1177\/0284185118770918","journal-title":"Acta Radiol"},{"key":"625_CR36","doi-asserted-by":"publisher","first-page":"W673","DOI":"10.2214\/AJR.12.10013","volume":"200","author":"S Yitta","year":"2013","unstructured":"Yitta S, Joe BN, Wisner DJ, Price ER, Hylton NM (2013) Recognizing artifacts and optimizing breast MRI at 1.5 and 3 T. AJR Am J Roentgenol 200:W673\u2013W682. https:\/\/doi.org\/10.2214\/AJR.12.10013","journal-title":"AJR Am J Roentgenol"},{"key":"625_CR37","doi-asserted-by":"publisher","first-page":"e601","DOI":"10.1016\/j.crad.2013.05.103","volume":"68","author":"V Fiaschetti","year":"2013","unstructured":"Fiaschetti V, Pistolese CA, Funel V et al (2013) Breast MRI artefacts: evaluation and solutions in 630 consecutive patients. Clin Radiol 68:e601\u2013e608. https:\/\/doi.org\/10.1016\/j.crad.2013.05.103","journal-title":"Clin Radiol"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00625-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-025-00625-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00625-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T12:21:58Z","timestamp":1759926118000},"score":1,"resource":{"primary":{"URL":"https:\/\/eurradiolexp.springeropen.com\/articles\/10.1186\/s41747-025-00625-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,8]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["625"],"URL":"https:\/\/doi.org\/10.1186\/s41747-025-00625-7","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,8]]},"assertion":[{"value":"7 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was approved by the ethics committee of the Friedrich-Alexander Universit\u00e4t Erlangen-N\u00fcrnberg (22-427-Br, 16.12.2022).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"SB, AL, and HS have a patent pending EPO No. 21197259.1 on methods associated with the topic of this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"100"}}