{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:37:42Z","timestamp":1793727462675,"version":"4.6.1"},"reference-count":80,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T00:00:00Z","timestamp":1767571200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T00:00:00Z","timestamp":1767571200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:sec>\n                    <jats:title>Abstract<\/jats:title>\n                    <jats:p>\n                      The latest technological advancements in CT enable the exploration of unprecedented limits of spatial resolution in\n                      <jats:italic>in vivo<\/jats:italic>\n                      imaging. Nowadays, ultra-high-resolution imaging is available by using CT with detector elements at or smaller than 0.25\u2009mm along the\n                      <jats:italic>z<\/jats:italic>\n                      -axis, like those used on photon-counting CT (PCCT) scanners. However, spatial resolution represents a complex criterion of imaging performance affected not only by detector elements, but also by other complex variables that can interact with each other. Knowledge of these variables and the metrics to evaluate spatial resolution is key to performing accurate cardiothoracic examinations with optimized CT protocols, which can eventually reduce acquisition times and radiation doses. This opens to a sustainable cardiothoracic radiology that permits accurate cardiac CT evaluations also in patients previously excluded, due to high calcium score, metallic stents or obesity, and allows to reduce radiation doses to never-seen levels. In this article, we review the technical advancements that allowed such an increase in spatial resolution in PCCT, along with all technical determinants of spatial resolution, the metrics to evaluate it, the clinical impact of UHR at PCCT and its challenges on cardiothoracic imaging.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Relevance statement<\/jats:title>\n                    <jats:p>Knowledge of the ultra-high spatial resolution capabilities of new photon-counting CT technology is key to its best uses\u00a0\u2014\u00a0performing accurate diagnostic examinations at unmatched low radiation doses and scanning patients previously excluded from cardiac CT examinations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:list list-type=\"bullet\">\n                        <jats:list-item>\n                          <jats:p>Photon-counting CT scanners enable radiologists to evaluate cardiothoracic examinations with an exceptional spatial resolution, along with spectral information and dose reduction.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>The ultra-high spatial resolution in cardiovascular imaging enables accurate assessment in patients previously excluded, such as obese, those with extensive calcifications or metallic stents.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Ultra-high spatial resolution empowers the visualization and follow-up of focal and diffuse lung diseases at unmatched accuracy and\u00a0low radiation doses.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Graphical Abstract<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-025-00656-0","type":"journal-article","created":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T18:05:33Z","timestamp":1767636333000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Ultra-high spatial resolution at photon-counting computed tomography: technical insights and sustainable applications in cardiothoracic imaging"],"prefix":"10.1186","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3324-4063","authenticated-orcid":false,"given":"Mariaelena","family":"Occhipinti","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Clemente","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carmelo","family":"De Gori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenzo","family":"Positano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danilo","family":"Neglia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simona","family":"Celi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonella","family":"Meloni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergio","family":"Berti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Filippo","family":"Cademartiri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,5]]},"reference":[{"key":"656_CR1","doi-asserted-by":"publisher","first-page":"1918","DOI":"10.21037\/cdt-20-530","volume":"10","author":"A Clemente","year":"2020","unstructured":"Clemente A, Seitun S, Mantini C et al (2020) Cardiac CT angiography: normal and pathological anatomical features\u2014a narrative review. Cardiovasc Diagn Ther 10:1918\u20131945","journal-title":"Cardiovasc Diagn Ther"},{"key":"656_CR2","doi-asserted-by":"crossref","unstructured":"Cademartiri F, Meloni A, Pistoia L et al (2023) Dual-source photon-counting computed tomography\u2014Part I: Clinical overview of cardiac CT and coronary CT angiography applications. J Clin Med 12:3627","DOI":"10.3390\/jcm12113627"},{"key":"656_CR3","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1148\/rg.2015140181","volume":"35","author":"H Machida","year":"2015","unstructured":"Machida H, Tanaka I, Fukui R et al (2015) Current and novel imaging techniques in coronary CT. Radiographics 35:991\u20131010","journal-title":"Radiographics"},{"key":"656_CR4","doi-asserted-by":"publisher","DOI":"10.1148\/ryct.230167","volume":"5","author":"L Koweek","year":"2023","unstructured":"Koweek L, Achenbach S, Berman DS et al (2023) Standardized medical terminology for cardiac computed tomography 2023 update: an expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), American Association of Physicists in Medicine (AAPM), American College of Radiology (ACR), North American Society for Cardiovascular Imaging (NASCI), and Radiological Society of North America (RSNA) with endorsement by the Asian Society of Cardiovascular Imaging (ASCI), the European Association of Cardiovascular Imaging (EACI), and the European Society of Cardiovascular Radiology (ESCR). Radiol Cardiothorac Imaging 5:e230167","journal-title":"Radiol Cardiothorac Imaging"},{"key":"656_CR5","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1097\/RLI.0000000000000897","volume":"57","author":"V Mergen","year":"2022","unstructured":"Mergen V, Sartoretti T, Baer-Beck M et al (2022) Ultra-high-resolution coronary CT angiography with photon-counting detector CT: feasibility and image characterization. Invest Radiol 57:780\u2013788","journal-title":"Invest Radiol"},{"key":"656_CR6","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1148\/radiol.2020192791","volume":"298","author":"AC Kwan","year":"2021","unstructured":"Kwan AC, Pourmorteza A, Stutman D, Bluemke DA, Lima JAC (2021) Next-generation hardware advances in CT: cardiac applications. Radiology 298:3\u201317","journal-title":"Radiology"},{"key":"656_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/gigascience\/gix027","volume":"6","author":"A du Plessis","year":"2017","unstructured":"du Plessis A, Broeckhoven C, Guelpa A, le Roux SG (2017) Laboratory x-ray micro-computed tomography: a user guideline for biological samples. Gigascience 6:1\u201311","journal-title":"Gigascience"},{"key":"656_CR8","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1148\/radiol.2018181156","volume":"289","author":"J Wang","year":"2018","unstructured":"Wang J, Fleischmann D (2018) Improving spatial resolution at CT: development, benefits, and pitfalls. Radiology 289:261\u2013262","journal-title":"Radiology"},{"key":"656_CR9","doi-asserted-by":"publisher","first-page":"e210196","DOI":"10.1148\/ryct.2021210196","volume":"3","author":"SM Shanbhag","year":"2021","unstructured":"Shanbhag SM, Chen MY (2021) Ultra-high-resolution coronary CT angiography: the \u201cfinal frontier\u201d\u2014are we there yet? Radiol Cardiothorac Imaging 3:e210196","journal-title":"Radiol Cardiothorac Imaging"},{"key":"656_CR10","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.21037\/cdt-20-527","volume":"10","author":"P Toia","year":"2020","unstructured":"Toia P, La Grutta L, Sollami G et al (2020) Technical development in cardiac CT: current standards and future improvements\u2014a narrative review. Cardiovasc Diagn Ther 10:2018\u20132035","journal-title":"Cardiovasc Diagn Ther"},{"key":"656_CR11","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/j.acra.2017.11.017","volume":"25","author":"A Hata","year":"2018","unstructured":"Hata A, Yanagawa M, Honda O et al (2018) Effect of matrix size on the image quality of ultra-high-resolution CT of the lung: comparison of 512 x 512, 1024 x 1024, and 2048 x 2048. Acad Radiol 25:869\u2013876","journal-title":"Acad Radiol"},{"key":"656_CR12","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1097\/RLI.0000000000000980","volume":"58","author":"T Flohr","year":"2023","unstructured":"Flohr T, Schmidt B (2023) Technical basics and clinical benefits of photon-counting CT. Invest Radiol 58:441\u2013450","journal-title":"Invest Radiol"},{"key":"656_CR13","doi-asserted-by":"crossref","unstructured":"Meloni A, Frijia F, Panetta D et al (2023) Photon-counting computed tomography (PCCT): technical background and cardio-vascular applications. Diagnostics (Basel) 13:645","DOI":"10.3390\/diagnostics13040645"},{"key":"656_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinimag.2023.110008","volume":"104","author":"JH Chamberlin","year":"2023","unstructured":"Chamberlin JH, Smith CD, Maisuria D et al (2023) Ultra-high-resolution photon-counting detector computed tomography of the lungs: phantom and clinical assessment of radiation dose and image quality. Clin Imaging 104:110008","journal-title":"Clin Imaging"},{"key":"656_CR15","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","volume":"303","author":"K Rajendran","year":"2022","unstructured":"Rajendran K, Petersilka M, Henning A et al (2022) First clinical photon-counting detector CT system: technical evaluation. Radiology 303:130\u2013138","journal-title":"Radiology"},{"key":"656_CR16","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20220544","volume":"96","author":"T Sartoretti","year":"2023","unstructured":"Sartoretti T, Wildberger JE, Flohr T, Alkadhi H (2023) Photon-counting detector CT: early clinical experience review. Br J Radiol 96:20220544","journal-title":"Br J Radiol"},{"key":"656_CR17","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1097\/RLI.0000000000000535","volume":"54","author":"W Zhou","year":"2019","unstructured":"Zhou W, Bartlett DJ, Diehn FE et al (2019) Reduction of metal artifacts and improvement in dose efficiency using photon-counting detector computed tomography and tin filtration. Invest Radiol 54:204\u2013211","journal-title":"Invest Radiol"},{"key":"656_CR18","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.diii.2022.11.003","volume":"104","author":"J Greffier","year":"2023","unstructured":"Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S (2023) Spectral CT imaging: technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging 104:167\u2013177","journal-title":"Diagn Interv Imaging"},{"key":"656_CR19","doi-asserted-by":"publisher","first-page":"6011","DOI":"10.1118\/1.4931053","volume":"42","author":"J Grimes","year":"2015","unstructured":"Grimes J, Duan X, Yu L et al (2015) The influence of focal spot blooming on high-contrast spatial resolution in CT imaging. Med Phys 42:6011\u20136020","journal-title":"Med Phys"},{"key":"656_CR20","doi-asserted-by":"publisher","first-page":"2040","DOI":"10.1002\/mp.17631","volume":"52","author":"SS Hsieh","year":"2025","unstructured":"Hsieh SS (2025) Overcoming the thermal limits of photon counting CT resolution using focal spot multiplexing: a feasibility study. Med Phys 52:2040\u20132051","journal-title":"Med Phys"},{"key":"656_CR21","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-59729-6","volume":"14","author":"P Feldle","year":"2024","unstructured":"Feldle P, Grunz JP, Huflage H et al (2024) Influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting detector CT. Sci Rep 14:9358","journal-title":"Sci Rep"},{"key":"656_CR22","doi-asserted-by":"publisher","first-page":"W64","DOI":"10.2214\/AJR.18.19851","volume":"212","author":"A Euler","year":"2019","unstructured":"Euler A, Solomon J, Farjat AE, Nelson RC, Samei E, Marin D (2019) High-pitch wide-coverage fast-kilovoltage-switching dual-energy CT: impact of pitch on noise, spatial resolution, and iodine quantification in a phantom study. AJR Am J Roentgenol 212:W64\u2013W72","journal-title":"AJR Am J Roentgenol"},{"key":"656_CR23","doi-asserted-by":"publisher","first-page":"e0234644","DOI":"10.1371\/journal.pone.0234644","volume":"15","author":"A Euler","year":"2020","unstructured":"Euler A, Martini K, Baessler B et al (2020) 1024-pixel image matrix for chest CT\u2014impact on image quality of bronchial structures in phantoms and patients. PLoS One 15:e0234644","journal-title":"PLoS One"},{"key":"656_CR24","doi-asserted-by":"crossref","unstructured":"Balmer BD, Bluthgen C, Bassler B et al (2022) Influence of CT image matrix size and kernel type on the assessment of HRCT in patients with SSC-ILD. Diagnostics (Basel) 12:1662","DOI":"10.3390\/diagnostics12071662"},{"key":"656_CR25","doi-asserted-by":"publisher","first-page":"5060","DOI":"10.1007\/s00330-018-5491-2","volume":"28","author":"M Yanagawa","year":"2018","unstructured":"Yanagawa M, Hata A, Honda O et al (2018) Subjective and objective comparisons of image quality between ultra-high-resolution CT and conventional area detector CT in phantoms and cadaveric human lungs. Eur Radiol 28:5060\u20135068","journal-title":"Eur Radiol"},{"key":"656_CR26","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1097\/RLI.0000000000000524","volume":"54","author":"DJ Bartlett","year":"2019","unstructured":"Bartlett DJ, Koo CW, Bartholmai BJ et al (2019) High-resolution chest computed tomography imaging of the lungs: impact of 1024 matrix reconstruction and photon-counting detector computed tomography. Invest Radiol 54:129\u2013137","journal-title":"Invest Radiol"},{"key":"656_CR27","doi-asserted-by":"publisher","DOI":"10.1148\/ryct.2021210102","volume":"3","author":"JR Rajagopal","year":"2021","unstructured":"Rajagopal JR, Farhadi F, Richards T et al (2021) Evaluation of coronary plaques and stents with conventional and photon-counting CT: benefits of high-resolution photon-counting CT. Radiol Cardiothorac Imaging 3:e210102","journal-title":"Radiol Cardiothorac Imaging"},{"key":"656_CR28","doi-asserted-by":"crossref","unstructured":"VanMeter P, Marsh J Jr, Rajendran K, Leng S, McCollough C (2022) Quantification of coronary calcification using high-resolution photon-counting-detector CT and an image domain denoising algorithm. Proc SPIE Int Soc Opt Eng 12031:120311R","DOI":"10.1117\/12.2612999"},{"key":"656_CR29","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.223305","volume":"307","author":"MT Hagar","year":"2023","unstructured":"Hagar MT, Soschynski M, Saffar R et al (2023) Accuracy of ultrahigh-resolution photon-counting CT for detecting coronary artery disease in a high-risk population. Radiology 307:e223305","journal-title":"Radiology"},{"key":"656_CR30","doi-asserted-by":"publisher","first-page":"2604","DOI":"10.1007\/s00330-021-08348-0","volume":"32","author":"F Ammon","year":"2022","unstructured":"Ammon F, Moshage M, Smolka S et al (2022) Influence of reconstruction kernels on the accuracy of CT-derived fractional flow reserve. Eur Radiol 32:2604\u20132610","journal-title":"Eur Radiol"},{"key":"656_CR31","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1016\/j.jcmg.2023.10.004","volume":"17","author":"M Eberhard","year":"2024","unstructured":"Eberhard M, Candreva A, Rajagopal R et al (2024) Coronary stenosis quantification with ultra-high-resolution photon-counting detector CT angiography: comparison with 3D quantitative coronary angiography. JACC Cardiovasc Imaging 17:342\u2013344","journal-title":"JACC Cardiovasc Imaging"},{"key":"656_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111426","volume":"175","author":"B Vattay","year":"2024","unstructured":"Vattay B, Boussoussou M, Vecsey-Nagy M et al (2024) Qualitative and quantitative image quality of coronary CT angiography using photon-counting computed tomography: standard and ultra-high resolution protocols. Eur J Radiol 175:111426","journal-title":"Eur J Radiol"},{"key":"656_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.110983","volume":"166","author":"AE Michael","year":"2023","unstructured":"Michael AE, Schoenbeck D, Becker-Assmann J et al (2023) Coronary stent imaging in photon counting computed tomography: optimization of reconstruction kernels in a phantom. Eur J Radiol 166:110983","journal-title":"Eur J Radiol"},{"key":"656_CR34","doi-asserted-by":"crossref","unstructured":"Deleu M, Maurice JB, Devos L, Remy M, Dubus F (2023) Image quality analysis of photon-counting CT compared with dual-source CT: a phantom study for chest CT examinations. Diagnostics (Basel) 13:1325","DOI":"10.3390\/diagnostics13071325"},{"key":"656_CR35","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1007\/s00330-021-08103-5","volume":"32","author":"SA Si-Mohamed","year":"2022","unstructured":"Si-Mohamed SA, Greffier J, Miailhes J et al (2022) Comparison of image quality between spectral photon-counting CT and dual-layer CT for the evaluation of lung nodules: a phantom study. Eur Radiol 32:524\u2013532","journal-title":"Eur Radiol"},{"key":"656_CR36","doi-asserted-by":"publisher","first-page":"672","DOI":"10.2214\/AJR.22.28515","volume":"220","author":"RI Milos","year":"2023","unstructured":"Milos RI, Rohrich S, Prayer F et al (2023) Ultrahigh-resolution photon-counting detector CT of the lungs: association of reconstruction kernel and slice thickness with image quality. AJR Am J Roentgenol 220:672\u2013680","journal-title":"AJR Am J Roentgenol"},{"key":"656_CR37","doi-asserted-by":"publisher","first-page":"2185","DOI":"10.1007\/s00330-018-5810-7","volume":"29","author":"MJ Willemink","year":"2019","unstructured":"Willemink MJ, Noel PB (2019) The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence. Eur Radiol 29:2185\u20132195","journal-title":"Eur Radiol"},{"key":"656_CR38","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/RLI.0000000000000860","volume":"57","author":"T Sartoretti","year":"2022","unstructured":"Sartoretti T, Mergen V, Higashigaito K, Eberhard M, Alkadhi H, Euler A (2022) Virtual noncontrast imaging of the liver using photon-counting detector computed tomography: a systematic phantom and patient study. Invest Radiol 57:488\u2013493","journal-title":"Invest Radiol"},{"key":"656_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111517","volume":"176","author":"M Vecsey-Nagy","year":"2024","unstructured":"Vecsey-Nagy M, Varga-Szemes A, Schoepf UJ et al (2024) Ultra-high resolution coronary CT angiography on photon-counting detector CT: bi-centre study on the impact of quantum iterative reconstruction on image quality and accuracy of stenosis measurements. Eur J Radiol 176:111517","journal-title":"Eur J Radiol"},{"key":"656_CR40","doi-asserted-by":"crossref","unstructured":"Sartoretti T, Racine D, Mergen V et al (2022) Quantum iterative reconstruction for low-dose ultra-high-resolution photon-counting detector CT of the lung. Diagnostics (Basel) 12:522","DOI":"10.3390\/diagnostics12020522"},{"key":"656_CR41","doi-asserted-by":"publisher","first-page":"8","DOI":"10.2214\/AJR.14.13022","volume":"204","author":"AS Phelps","year":"2015","unstructured":"Phelps AS, Naeger DM, Courtier JL et al (2015) Pairwise comparison versus Likert scale for biomedical image assessment. AJR Am J Roentgenol 204:8\u201314","journal-title":"AJR Am J Roentgenol"},{"key":"656_CR42","doi-asserted-by":"crossref","unstructured":"Van Ballaer V, Dubbeldam A, Muscogiuri E et al (2023) Impact of ultra-high-resolution imaging of the lungs on perceived diagnostic image quality using photon-counting CT. Eur Radiol 34:1895\u20131904","DOI":"10.1007\/s00330-023-10174-5"},{"key":"656_CR43","doi-asserted-by":"publisher","DOI":"10.1186\/s40644-023-00592-5","volume":"23","author":"D Graafen","year":"2023","unstructured":"Graafen D, Stoehr F, Halfmann MC et al (2023) Quantum iterative reconstruction on a photon-counting detector CT improves the quality of hepatocellular carcinoma imaging. Cancer Imaging 23:69","journal-title":"Cancer Imaging"},{"key":"656_CR44","doi-asserted-by":"publisher","first-page":"e735","DOI":"10.1002\/mp.13763","volume":"46","author":"E Samei","year":"2019","unstructured":"Samei E, Bakalyar D, Boedeker KL et al (2019) Performance evaluation of computed tomography systems: summary of AAPM Task Group 233. Med Phys 46:e735\u2013e756","journal-title":"Med Phys"},{"key":"656_CR45","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1097\/RLI.0000000000001013","volume":"59","author":"H Huflage","year":"2024","unstructured":"Huflage H, Hendel R, Kunz AS et al (2024) Investigating the small pixel effect in ultra-high resolution photon-counting CT of the lung. Invest Radiol 59:293\u2013297","journal-title":"Invest Radiol"},{"key":"656_CR46","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1097\/RLI.0000000000000888","volume":"57","author":"A Inoue","year":"2022","unstructured":"Inoue A, Johnson TF, White D et al (2022) Estimating the clinical impact of photon-counting-detector CT in diagnosing usual interstitial pneumonia. Invest Radiol 57:734\u2013741","journal-title":"Invest Radiol"},{"key":"656_CR47","doi-asserted-by":"publisher","first-page":"1939","DOI":"10.1093\/bjr\/tqae170","volume":"97","author":"L Jungblut","year":"2024","unstructured":"Jungblut L, Sartoretti T, Landsmann A et al (2024) Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix. Br J Radiol 97:1939\u20131945","journal-title":"Br J Radiol"},{"key":"656_CR48","doi-asserted-by":"crossref","unstructured":"Wang J, Huang Z, Zhu Z et al (2025) Photon-counting detector CT provides superior subsolid nodule characterization compared to same-day energy-integrating detector CT. Eur Radiol 35:2979\u20132989","DOI":"10.1007\/s00330-024-11204-6"},{"key":"656_CR49","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1177\/02841851241275289","volume":"65","author":"L Jungblut","year":"2024","unstructured":"Jungblut L, Euler A, Landsmann A et al (2024) Pulmonary nodule visualization and evaluation of AI-based detection at various ultra-low-dose levels using photon-counting detector CT. Acta Radiol 65:1238\u20131245","journal-title":"Acta Radiol"},{"key":"656_CR50","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.diii.2024.09.011","volume":"106","author":"H Lacombe","year":"2025","unstructured":"Lacombe H, Labour J, de Oliveira F et al (2025) Ultra-high resolution spectral photon-counting CT outperforms dual layer CT for lung imaging: results of a phantom study. Diagn Interv Imaging 106:60\u201367","journal-title":"Diagn Interv Imaging"},{"key":"656_CR51","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.240271","volume":"312","author":"RI Milos","year":"2024","unstructured":"Milos RI, Lechner L, Korajac A et al (2024) Accuracy of ultralow-dose photon-counting CT in the detection of lung changes after lung transplant. Radiology 312:e240271","journal-title":"Radiology"},{"key":"656_CR52","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1186\/s41747-024-00482-w","volume":"8","author":"E Zsarnoczay","year":"2024","unstructured":"Zsarnoczay E, Fink N, Schoepf UJ et al (2024) Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study. Eur Radiol Exp 8:102","journal-title":"Eur Radiol Exp"},{"key":"656_CR53","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1097\/RLI.0000000000001109","volume":"60","author":"G Fahrni","year":"2025","unstructured":"Fahrni G, Boccalini S, Mahmoudi A et al (2025) Quantification of coronary artery stenosis in very-high-risk patients using ultra-high resolution spectral photon-counting CT. Invest Radiol 60:114\u2013122","journal-title":"Invest Radiol"},{"key":"656_CR54","doi-asserted-by":"crossref","unstructured":"Mergen V, Rusek S, Civaia F et al (2024) Virtual calcium removal in calcified coronary arteries with photon-counting detector CT\u2014first in-vivo experience. Front Cardiovasc Med 11:1367463","DOI":"10.3389\/fcvm.2024.1367463"},{"key":"656_CR55","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.231956","volume":"310","author":"MCB Halfmann","year":"2024","unstructured":"Halfmann MCB, Emrich ST, Hell M (2024) Ultrahigh-spatial-resolution photon-counting detector CT angiography of coronary artery disease for stenosis assessment. Radiology 310:e231956","journal-title":"Radiology"},{"key":"656_CR56","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.jcct.2023.11.079","volume":"18","author":"J Simon","year":"2024","unstructured":"Simon J, Hrenko A, Kerkovits NM et al (2024) Photon-counting detector CT reduces the rate of referrals to invasive coronary angiography as compared to CT with whole heart coverage energy-integrating detector. J Cardiovasc Comput Tomogr 18:69\u201374","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"656_CR57","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.124.017112","volume":"17","author":"M Vecsey-Nagy","year":"2024","unstructured":"Vecsey-Nagy M, Tremamunno G, Schoepf UJ et al (2024) Intraindividual comparison of ultrahigh-spatial-resolution photon-counting detector CT and energy-integrating detector CT for coronary stenosis measurement. Circ Cardiovasc Imaging 17:e017112","journal-title":"Circ Cardiovasc Imaging"},{"key":"656_CR58","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.jcct.2023.10.009","volume":"18","author":"EK Koons","year":"2024","unstructured":"Koons EK, Rajiah PS, Thorne JE et al (2024) Coronary artery stenosis quantification in patients with dense calcifications using ultra-high-resolution photon-counting-detector computed tomography. J Cardiovasc Comput Tomogr 18:56\u201361","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"656_CR59","doi-asserted-by":"publisher","first-page":"2181","DOI":"10.1007\/s10554-024-03209-5","volume":"40","author":"M Wang","year":"2024","unstructured":"Wang M, Zhang X, Li J et al (2024) Quantification accuracy in photon-counting detector CT for coronary artery calcium score: a pilot study. Int J Cardiovasc Imaging 40:2181\u20132191","journal-title":"Int J Cardiovasc Imaging"},{"key":"656_CR60","doi-asserted-by":"crossref","unstructured":"Tremamunno G, Varga-Szemes A, Kravchenko D et al (2025) Accuracy of photon-counting detector CT-based iodine maps for myocardial late enhancement detection. Eur Radiol 35:7074\u20137083","DOI":"10.1007\/s00330-025-11622-0"},{"key":"656_CR61","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1097\/RLI.0000000000000995","volume":"58","author":"M Lell","year":"2023","unstructured":"Lell M, Kachelriess M (2023) Computed tomography 2.0: new detector technology, AI, and other developments. Invest Radiol 58:587\u2013601","journal-title":"Invest Radiol"},{"key":"656_CR62","doi-asserted-by":"publisher","first-page":"3699","DOI":"10.1007\/s00330-023-10402-y","volume":"34","author":"SP Sharma","year":"2024","unstructured":"Sharma SP, van der Bie J, van Straten M et al (2024) Coronary calcium scoring on virtual non-contrast and virtual non-iodine reconstructions compared to true non-contrast images using photon-counting computed tomography. Eur Radiol 34:3699\u20133707","journal-title":"Eur Radiol"},{"key":"656_CR63","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.230545","volume":"310","author":"NP Haag","year":"2024","unstructured":"Haag NP, Michael AE, Lennartz S et al (2024) Coronary artery calcium scoring using virtual versus true noncontrast images from photon-counting coronary CT angiography. Radiology 310:e230545","journal-title":"Radiology"},{"key":"656_CR64","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2024.e32819","volume":"10","author":"S Zhou","year":"2024","unstructured":"Zhou S, Liu P, Dong H et al (2024) Performance of calcium quantifications on low-dose photon-counting detector CT with high-pitch: a phantom study. Heliyon 10:e32819","journal-title":"Heliyon"},{"key":"656_CR65","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111354","volume":"172","author":"T Nishihara","year":"2024","unstructured":"Nishihara T, Miyoshi T, Nakashima M et al (2024) Diagnostic improvements of calcium-removal image reconstruction algorithm using photon-counting detector CT for calcified coronary lesions. Eur J Radiol 172:111354","journal-title":"Eur J Radiol"},{"key":"656_CR66","doi-asserted-by":"publisher","first-page":"2048","DOI":"10.1002\/mp.12834","volume":"45","author":"X Duan","year":"2018","unstructured":"Duan X, Arbique G, Guild J, Xi Y, Anderson J (2018) Technical Note: Quantitative accuracy evaluation for spectral images from a detector-based spectral CT scanner using an iodine phantom. Med Phys 45:2048\u20132053","journal-title":"Med Phys"},{"key":"656_CR67","doi-asserted-by":"crossref","unstructured":"Fahrni G, Boccalini S, Lacombe H et al (2024) Ultra-high-resolution 40 keV virtual monoenergetic imaging using spectral photon-counting CT in high-risk patients for coronary stenoses. Eur Radiol 35:3042\u20133053","DOI":"10.1007\/s00330-024-11237-x"},{"key":"656_CR68","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.23.30481","volume":"222","author":"EV Wolf","year":"2024","unstructured":"Wolf EV, Halfmann MC, Varga-Szemes A et al (2024) Photon-counting detector CT virtual monoenergetic images for coronary artery stenosis quantification: phantom and in vivo evaluation. AJR Am J Roentgenol 222:e2330481","journal-title":"AJR Am J Roentgenol"},{"key":"656_CR69","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.23.30631","volume":"222","author":"Y Yang","year":"2024","unstructured":"Yang Y, Qin L, Lin H et al (2024) Consistency of monoenergetic attenuation measurements for a clinical dual-source photon-counting detector CT system across scanning paradigms: a phantom study. AJR Am J Roentgenol 222:e2330631","journal-title":"AJR Am J Roentgenol"},{"key":"656_CR70","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.230853","volume":"309","author":"CH McCollough","year":"2023","unstructured":"McCollough CH, Rajiah P, Bois JP et al (2023) Comparison of photon-counting detector and energy-integrating detector CT for visual estimation of coronary percent luminal stenosis. Radiology 309:e230853","journal-title":"Radiology"},{"key":"656_CR71","doi-asserted-by":"publisher","first-page":"539","DOI":"10.2214\/AJR.23.29463","volume":"221","author":"AM Salyapongse","year":"2023","unstructured":"Salyapongse AM, Rose SD, Pickhardt PJ et al (2023) CT number accuracy and association with object size: a phantom study comparing energy-integrating detector CT and deep silicon photon-counting detector CT. AJR Am J Roentgenol 221:539\u2013547","journal-title":"AJR Am J Roentgenol"},{"key":"656_CR72","doi-asserted-by":"crossref","unstructured":"Sotoudeh-Paima S, Segars WP, Samei E, Abadi E (2022) Photon-counting CT versus conventional CT for COPD quantifications: intra-scanner optimization and inter-scanner assessments using virtual imaging trials. Proc SPIE Int Soc Opt Eng 12031:120312I","DOI":"10.1117\/12.2613003"},{"key":"656_CR73","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1148\/radiol.2015141579","volume":"277","author":"DA Lynch","year":"2015","unstructured":"Lynch DA, Austin JH, Hogg JC et al (2015) CT-definable subtypes of chronic obstructive pulmonary disease: a statement of the Fleischner Society. Radiology 277:192\u2013205","journal-title":"Radiology"},{"key":"656_CR74","first-page":"384","volume":"6","author":"KE Lowe","year":"2019","unstructured":"Lowe KE, Regan EA, Anzueto A et al (2019) COPDGene\u00ae 2019: redefining the diagnosis of chronic obstructive pulmonary disease. Chronic Obstr Pulm Dis 6:384\u2013399","journal-title":"Chronic Obstr Pulm Dis"},{"key":"656_CR75","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.123.015340","volume":"16","author":"Q Chen","year":"2023","unstructured":"Chen Q, Xie G, Tang CX et al (2023) Development and validation of CCTA-based radiomics signature for predicting coronary plaques with rapid progression. Circ Cardiovasc Imaging 16:e015340","journal-title":"Circ Cardiovasc Imaging"},{"key":"656_CR76","doi-asserted-by":"publisher","DOI":"10.1186\/s12880-025-01825-8","volume":"25","author":"M Ronning","year":"2025","unstructured":"Ronning M, Johansen E, Rusandu A (2025) Photon-counting CT versus energy-integrating detectors for cardiac imaging: a systematic review of evidence from in vivo human studies on image quality and radiation dose. BMC Med Imaging 25:295","journal-title":"BMC Med Imaging"},{"key":"656_CR77","doi-asserted-by":"publisher","first-page":"4780","DOI":"10.1016\/j.acra.2024.06.014","volume":"31","author":"T Dirrichs","year":"2024","unstructured":"Dirrichs T, Schroder J, Frick M et al (2024) Photon-counting versus dual-source CT for transcatheter aortic valve implantation planning. Acad Radiol 31:4780\u20134789","journal-title":"Acad Radiol"},{"key":"656_CR78","doi-asserted-by":"crossref","unstructured":"Eberhard M, Mergen V, Higashigaito K et al (2021) Coronary calcium scoring with first generation dual-source photon-counting CT\u2014first evidence from phantom and in-vivo scans. Diagnostics 11:1708","DOI":"10.3390\/diagnostics11091708"},{"key":"656_CR79","doi-asserted-by":"crossref","unstructured":"Goldman LW (2008) Principles of CT: multislice CT. J Nucl Med Technol 36:57\u201368","DOI":"10.2967\/jnmt.107.044826"},{"key":"656_CR80","doi-asserted-by":"crossref","unstructured":"Flohr T, Ohnesorge B (2007) Multi-slice CT technology. In: Multi-slice and dual-source CT in cardiac imaging: principles\u2014protocols\u2014indications\u2014outlook. Springer, Berlin, pp 41\u201369","DOI":"10.1007\/978-3-540-49546-8_3"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00656-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-025-00656-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-025-00656-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T06:03:42Z","timestamp":1767679422000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41747-025-00656-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,5]]},"references-count":80,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["656"],"URL":"https:\/\/doi.org\/10.1186\/s41747-025-00656-0","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,5]]},"assertion":[{"value":"23 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"MO and FC are members of the Scientific Editorial Board of\n                      European Radiology Experimental\n                      (sections: Chest\/Thorax and Cardiovascular, respectively). As such, they did not participate in the selection or review processes for this article. The remaining authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"2"}}