{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T14:08:47Z","timestamp":1776780527558,"version":"3.51.2"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T00:00:00Z","timestamp":1776729600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T00:00:00Z","timestamp":1776729600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100030760","name":"Bayer in The US","doi-asserted-by":"publisher","award":["IRR-US02018-5862"],"award-info":[{"award-number":["IRR-US02018-5862"]}],"id":[{"id":"10.13039\/100030760","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) can assess kidney function, but artifacts and complex post-processing limit its use. We calculated estimated glomerular filtration rate (eGFR) and renal plasma flow (RPF) by combining a population-based arterial input function (pAIF) with a whole-kidney pharmacokinetic model (WKPM). We also compared DCE-MRI eGFR and RPF with serum eGFR and arterial spin labeling (ASL) derived RPF, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      In a prospective single-center study, 43 patients (30\u2009M\/13\u2009F, 59.0\u2009\u00b1\u200911.8\u2009y) with renal masses underwent multiparametric 1.5-T MRI, before and 3 months after nephrectomy (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200915), including coronal, fat-saturated volumetric DCE-MRI (5-s temporal resolution)\u00a0and background-suppressed pseudocontinuous ASL. DCE-MRI eGFR and RPF were measured by WKPM, incorporating individual-based arterial input function (iAIF) and population-based arterial input function (pAIF) as inputs. Pearson correlation, Bland-Altman analysis, and Mann-Whitney\n                      <jats:italic>U<\/jats:italic>\n                      statistics were used.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Serum eGFR (mean 67.55\u2009mL\/min\/1.73\u2009m\u00b2) and DCE-MRI (mean eGFR pAIF 59.49, iAIF 63.60\u2009mL\/min\/1.73\u2009m\u00b2) were measured in 51 MRIs: correlation with serum eGFR was stronger for pAIF (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.61,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) than iAIF (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.33,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.018), with comparable Bland-Altman bias (-11.9% and -9.1%, respectively). RPF was measured by both DCE-MRI and ASL in 21 MRIs: mean RPF was 229.3 (ASL), 229.7 (pAIF), and 390.4 (iAIF) mL\/min (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.018). Correlation of pAIF RPF with ASL-derived RPF (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.65,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) was stronger than for iAIF RPF (r\u2009=\u20090.53,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.014), with lower Bland-Altman bias (pAIF -1.0%\n                      <jats:italic>versus<\/jats:italic>\n                      iAIF 39.5%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>DCE-MRI using pAIF and WKPM provides simplified, robust single-kidney function estimates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Relevance statement<\/jats:title>\n                    <jats:p>This study proposes a simplified DCE-MRI post-processing method using a population-based arterial input function combined with a whole-kidney pharmacokinetic model. It avoids complex corticomedullary segmentation and minimizes aortic region-of-interest variability, and enables clinically feasible estimation of single-kidney function, supporting broader adoption of renal DCE-MRI in clinical practice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:list list-type=\"bullet\">\n                        <jats:list-item>\n                          <jats:p>Population-based arterial input function reduces inter-observer variability and sensitivity to aortic region-of-interest placement artifacts.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Whole-kidney modeling avoids complex segmentation of the cortex and medulla regions.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>DCE-MRI using population-AIF and whole-kidney modeling yields eGFR and RPF significantly correlated with serum and ASL references.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Streamlined post-processing workflow supports broader routine clinical use of DCE-MRI.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Graphical Abstract<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-026-00704-3","type":"journal-article","created":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T13:19:09Z","timestamp":1776777549000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Streamlined calculation of kidney function using dynamic contrast-enhanced MRI with population-based arterial input function and a whole-kidney model"],"prefix":"10.1186","volume":"10","author":[{"given":"Xin","family":"Mu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mira M.","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haitham","family":"Al-Mubarak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Kennedy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip","family":"Robson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jordan","family":"Cuevas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernd","family":"Kuhn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ketan","family":"Badani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bachir","family":"Taouli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Lewis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1315-5848","authenticated-orcid":false,"given":"Octavia","family":"Bane","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,4,21]]},"reference":[{"key":"704_CR1","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1002\/jmri.28828","volume":"58","author":"O Bane","year":"2023","unstructured":"Bane O, Seeliger E, Cox E et al (2023) Renal MRI: from nephron to NMR signal. J Magn Reson Imaging 58:1660\u20131679. https:\/\/doi.org\/10.1002\/jmri.28828","journal-title":"J Magn Reson Imaging"},{"key":"704_CR2","doi-asserted-by":"crossref","unstructured":"Verbruggen AM, De Roo M (2018) Renal radiopharmaceuticals. Radiopharmaceuticals. Routledge, pp. 365\u2012430","DOI":"10.1201\/9780203741313-10"},{"key":"704_CR3","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1053\/j.ajkd.2021.04.016","volume":"78","author":"LA Inker","year":"2021","unstructured":"Inker LA, Titan S (2021) Measurement and estimation of GFR for use in clinical practice: core curriculum 2021. Am J Kidney Dis 78:736\u2013749. https:\/\/doi.org\/10.1053\/j.ajkd.2021.04.016","journal-title":"Am J Kidney Dis"},{"key":"704_CR4","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.mric.2023.09.004","volume":"32","author":"M Wu","year":"2024","unstructured":"Wu M, Zhang JL (2024) MR perfusion imaging for kidney disease. Magn Reson Imaging Clin N Am 32:161\u2013170. https:\/\/doi.org\/10.1016\/j.mric.2023.09.004","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"704_CR5","doi-asserted-by":"publisher","first-page":"7","DOI":"10.2478\/prilozi-2023-0042","volume":"44","author":"D Miladinova","year":"2023","unstructured":"Miladinova D, Makazlieva T, Peshevska A et al (2023) The current state of nuclear nephrology in modern medicine. Pril (Makedon Akad Nauk Umet Odd Med Nauki) 44:7\u201316. https:\/\/doi.org\/10.2478\/prilozi-2023-0042","journal-title":"Pril (Makedon Akad Nauk Umet Odd Med Nauki)"},{"key":"704_CR6","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1007\/s10334-019-00800-z","volume":"33","author":"F Nery","year":"2020","unstructured":"Nery F, Buchanan CE, Harteveld AA et al (2020) Consensus-based technical recommendations for clinical translation of renal ASL MRI. MAGMA 33:141\u2013161. https:\/\/doi.org\/10.1007\/s10334-019-00800-z","journal-title":"MAGMA"},{"key":"704_CR7","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1007\/s00261-022-03770-4","volume":"48","author":"S Pi","year":"2023","unstructured":"Pi S, Li Y, Lin C et al (2023) Arterial spin labeling and diffusion-weighted MR imaging: quantitative assessment of renal pathological injury in chronic kidney disease. Abdom Radiol (NY) 48:999\u20131010. https:\/\/doi.org\/10.1007\/s00261-022-03770-4","journal-title":"Abdom Radiol (NY)"},{"key":"704_CR8","doi-asserted-by":"publisher","first-page":"100344","DOI":"10.1016\/j.cotox.2022.03.005","volume":"31","author":"LE Thompson","year":"2022","unstructured":"Thompson LE, Joy MS (2022) Endogenous markers of kidney function and renal drug clearance processes of filtration, secretion, and reabsorption. Curr Opin Toxicol 31:100344. https:\/\/doi.org\/10.1016\/j.cotox.2022.03.005","journal-title":"Curr Opin Toxicol"},{"key":"704_CR9","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1002\/mrm.10380","volume":"49","author":"S Aumann","year":"2003","unstructured":"Aumann S, Schoenberg SO, Just A et al (2003) Quantification of renal perfusion using an intravascular contrast agent (part 1): results in a canine model. Magn Reson Med 49:276\u2013287. https:\/\/doi.org\/10.1002\/mrm.10380","journal-title":"Magn Reson Med"},{"key":"704_CR10","doi-asserted-by":"publisher","first-page":"124301","DOI":"10.1118\/1.4898202","volume":"41","author":"F Khalifa","year":"2014","unstructured":"Khalifa F, Soliman A, El-Baz A et al (2014) Models and methods for analyzing DCE-MRI: a review. Med Phys 41:124301. https:\/\/doi.org\/10.1118\/1.4898202","journal-title":"Med Phys"},{"key":"704_CR11","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1148\/radiol.11101338","volume":"259","author":"P-H Vivier","year":"2011","unstructured":"Vivier P-H, Storey P, Rusinek H et al (2011) Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis. Radiology 259:462\u2013470. https:\/\/doi.org\/10.1148\/radiol.11101338","journal-title":"Radiology"},{"key":"704_CR12","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1002\/mrm.21489","volume":"59","author":"JL Zhang","year":"2008","unstructured":"Zhang JL, Rusinek H, Bokacheva L et al (2008) Functional assessment of the kidney from magnetic resonance and computed tomography renography: impulse retention approach to a multicompartment model. Magn Reson Med 59:278\u2013288. https:\/\/doi.org\/10.1002\/mrm.21489","journal-title":"Magn Reson Med"},{"key":"704_CR13","doi-asserted-by":"publisher","first-page":"F1548","DOI":"10.1152\/ajprenal.00347.2006","volume":"292","author":"VS Lee","year":"2007","unstructured":"Lee VS, Rusinek H, Bokacheva L et al (2007) Renal function measurements from MR renography and a simplified multicompartmental model. Am J Physiol Renal Physiol 292:F1548\u2013F1559. https:\/\/doi.org\/10.1152\/ajprenal.00347.2006","journal-title":"Am J Physiol Renal Physiol"},{"key":"704_CR14","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1007\/s00330-012-2382-9","volume":"22","author":"PS Tofts","year":"2012","unstructured":"Tofts PS, Cutajar M, Mendichovszky IA et al (2012) Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values. Eur Radiol 22:1320\u20131330. https:\/\/doi.org\/10.1007\/s00330-012-2382-9","journal-title":"Eur Radiol"},{"key":"704_CR15","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1002\/jmri.21642","volume":"29","author":"L Bokacheva","year":"2009","unstructured":"Bokacheva L, Rusinek H, Zhang JL et al (2009) Estimates of glomerular filtration rate from MR renography and tracer kinetic models. J Magn Reson Imaging 29:371\u2013382. https:\/\/doi.org\/10.1002\/jmri.21642","journal-title":"J Magn Reson Imaging"},{"key":"704_CR16","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1002\/jmri.23717","volume":"37","author":"JL Zhang","year":"2013","unstructured":"Zhang JL, Rusinek H, Chandarana H, Lee VS (2013) Functional MRI of the kidneys. J Magn Reson Imaging 37:282\u2013293. https:\/\/doi.org\/10.1002\/jmri.23717","journal-title":"J Magn Reson Imaging"},{"key":"704_CR17","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1002\/jmri.20699","volume":"24","author":"DL Buckley","year":"2006","unstructured":"Buckley DL, Shurrab AE, Cheung CM et al (2006) Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects. J Magn Reson Imaging 24:1117\u20131123. https:\/\/doi.org\/10.1002\/jmri.20699","journal-title":"J Magn Reson Imaging"},{"key":"704_CR18","doi-asserted-by":"publisher","first-page":"71577","DOI":"10.1109\/ACCESS.2021.3078430","volume":"9","author":"FG Z\u00f6llner","year":"2021","unstructured":"Z\u00f6llner FG, Koci\u0144ski M, Hansen L et al (2021) Kidney segmentation in renal magnetic resonance imaging-current status and prospects. IEEE Access 9:71577\u201371605. https:\/\/doi.org\/10.1109\/ACCESS.2021.3078430","journal-title":"IEEE Access"},{"key":"704_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2020.101821","volume":"67","author":"N Heller","year":"2021","unstructured":"Heller N, Isensee F, Maier-Hein KH et al (2021) The state of the art in kidney and kidney tumor segmentation in contrast-enhanced CT imaging: Results of the KiTS19 challenge. Med Image Anal 67: 101821. https:\/\/doi.org\/10.1016\/j.media.2020.101821","journal-title":"Med Image Anal"},{"key":"704_CR20","doi-asserted-by":"publisher","first-page":"6714","DOI":"10.3390\/s21206714","volume":"21","author":"A Klepaczko","year":"2021","unstructured":"Klepaczko A, Eikefjord E, Lundervold A (2021) Healthy kidney segmentation in the Dce-Mr images using a convolutional neural network and temporal signal characteristics. Sensors (Basel) 21:6714. https:\/\/doi.org\/10.3390\/s21206714","journal-title":"Sensors (Basel)"},{"key":"704_CR21","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1002\/mrm.22856","volume":"66","author":"GO Cron","year":"2011","unstructured":"Cron GO, Foottit C, Yankeelov TE et al (2011) Arterial input functions determined from MR signal magnitude and phase for quantitative dynamic contrast-enhanced MRI in the human pelvis. Magn Reson Med 66:498\u2013504. https:\/\/doi.org\/10.1002\/mrm.22856","journal-title":"Magn Reson Med"},{"key":"704_CR22","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1002\/nbm.3553","volume":"29","author":"JL Zhang","year":"2016","unstructured":"Zhang JL, Conlin CC, Carlston K et al (2016) Optimization of saturation-recovery dynamic contrast-enhanced MRI acquisition protocol: Monte Carlo simulation approach demonstrated with gadolinium MR renography. NMR Biomed 29:969\u2013977. https:\/\/doi.org\/10.1002\/nbm.3553","journal-title":"NMR Biomed"},{"key":"704_CR23","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1016\/j.ejrad.2008.09.025","volume":"71","author":"IA Mendichovszky","year":"2009","unstructured":"Mendichovszky IA, Cutajar M, Gordon I (2009) Reproducibility of the aortic input function (AIF) derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the kidneys in a volunteer study. Eur J Radiol 71:576\u2013581. https:\/\/doi.org\/10.1016\/j.ejrad.2008.09.025","journal-title":"Eur J Radiol"},{"key":"704_CR24","doi-asserted-by":"publisher","first-page":"e154","DOI":"10.1016\/j.ejrad.2009.05.041","volume":"74","author":"M Cutajar","year":"2010","unstructured":"Cutajar M, Mendichovszky IA, Tofts PS et al (2010) The importance of AIF ROI selection in DCE-MRI renography: reproducibility and variability of renal perfusion and filtration. Eur J Radiol 74:e154\u2013e160. https:\/\/doi.org\/10.1016\/j.ejrad.2009.05.041","journal-title":"Eur J Radiol"},{"key":"704_CR25","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.mri.2023.03.016","volume":"101","author":"J Roberts","year":"2023","unstructured":"Roberts J, Kim SE, Kholmovski EG et al (2023) The arterial input function: Spatial dependence within the imaging volume and its influence on 3D quantitative dynamic contrast-enhanced MRI for head and neck cancer. Magn Reson Imaging 101:40\u201346. https:\/\/doi.org\/10.1016\/j.mri.2023.03.016","journal-title":"Magn Reson Imaging"},{"key":"704_CR26","doi-asserted-by":"publisher","first-page":"5753","DOI":"10.1088\/0031-9155\/56\/17\/018","volume":"56","author":"X Li","year":"2011","unstructured":"Li X, Welch EB, Arlinghaus LR et al (2011) A novel AIF tracking method and comparison of DCE-MRI parameters using individual and population-based AIFs in human breast cancer. Phys Med Biol 56:5753\u20135769. https:\/\/doi.org\/10.1088\/0031-9155\/56\/17\/018","journal-title":"Phys Med Biol"},{"key":"704_CR27","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1002\/mrm.21066","volume":"56","author":"GJ Parker","year":"2006","unstructured":"Parker GJ, Roberts C, Macdonald A et al (2006) Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med 56:993\u20131000. https:\/\/doi.org\/10.1002\/mrm.21066","journal-title":"Magn Reson Med"},{"key":"704_CR28","unstructured":"Ahmed Z (2020) Advancements to the reference region model for dynamic contrast enhanced MRI. Dissertation, McGill University"},{"key":"704_CR29","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1002\/jmri.25034","volume":"43","author":"M Azahaf","year":"2016","unstructured":"Azahaf M, Haberley M, Betrouni N et al (2016) Impact of arterial input function selection on the accuracy of dynamic contrast-enhanced MRI quantitative analysis for the diagnosis of clinically significant prostate cancer. J Magn Reson Imaging 43:737\u2013749. https:\/\/doi.org\/10.1002\/jmri.25034","journal-title":"J Magn Reson Imaging"},{"key":"704_CR30","doi-asserted-by":"publisher","first-page":"2857","DOI":"10.1088\/0031-9155\/51\/11\/012","volume":"51","author":"TS Koh","year":"2006","unstructured":"Koh TS, Zhang JL, Ong CK et al (2006) A biphasic parameter estimation method for quantitative analysis of dynamic renal scintigraphic data. Phys Med Biol 51:2857\u20132870. https:\/\/doi.org\/10.1088\/0031-9155\/51\/11\/012","journal-title":"Phys Med Biol"},{"key":"704_CR31","unstructured":"Conlin CC (2019) Functional assessment of the kidneys with magnetic resonance imaging and tracer-kinetic modeling. Dissertation, The University of Utah"},{"key":"704_CR32","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1002\/mrm.20580","volume":"54","author":"M G\u00fcnther","year":"2005","unstructured":"G\u00fcnther M, Oshio K, Feinberg DA (2005) Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements. Magn Reson Med 54:491\u2013498. https:\/\/doi.org\/10.1002\/mrm.20580","journal-title":"Magn Reson Med"},{"key":"704_CR33","doi-asserted-by":"crossref","unstructured":"Robson MD, Fernandes CC, Teixeira R et al (2023) T1 mapping of the kidney. Advanced clinical MRI of the kidney: methods and protocols. Springer, pp. 111\u2013123","DOI":"10.1007\/978-3-031-40169-5_8"},{"key":"704_CR34","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.1056\/NEJMoa2102953","volume":"385","author":"LA Inker","year":"2021","unstructured":"Inker LA, Eneanya ND, Coresh J et al (2021) New creatinine- and cystatin C-based equations to estimate GFR without race. N Engl J Med 385:1737\u20131749. https:\/\/doi.org\/10.1056\/NEJMoa2102953","journal-title":"N Engl J Med"},{"key":"704_CR35","doi-asserted-by":"publisher","first-page":"1861","DOI":"10.1093\/ckj\/sfab042","volume":"14","author":"N Ebert","year":"2021","unstructured":"Ebert N, Bevc S, B\u00f6kenkamp A et al (2021) Assessment of kidney function: clinical indications for measured GFR. Clin Kidney J 14:1861\u20131870. https:\/\/doi.org\/10.1093\/ckj\/sfab042","journal-title":"Clin Kidney J"},{"key":"704_CR36","doi-asserted-by":"publisher","first-page":"2935","DOI":"10.1002\/mrm.26955","volume":"79","author":"K Jiang","year":"2018","unstructured":"Jiang K, Tang H, Mishra PK et al (2018) Measurement of murine single-kidney glomerular filtration rate using dynamic contrast-enhanced MRI. Magn Reson Med 79:2935\u20132943. https:\/\/doi.org\/10.1002\/mrm.26955","journal-title":"Magn Reson Med"},{"key":"704_CR37","doi-asserted-by":"publisher","first-page":"R690","DOI":"10.1152\/ajpregu.00237.2020","volume":"319","author":"AH Jufar","year":"2020","unstructured":"Jufar AH, Lankadeva YR, May CN et al (2020) Renal functional reserve: from physiological phenomenon to clinical biomarker and beyond. Am J Physiol Regul Integr Comp Physiol 319:R690\u2013R702. https:\/\/doi.org\/10.1152\/ajpregu.00237.2020","journal-title":"Am J Physiol Regul Integr Comp Physiol"},{"key":"704_CR38","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1002\/mrm.21131","volume":"57","author":"TE Yankeelov","year":"2007","unstructured":"Yankeelov TE, Cron GO, Addison CL et al (2007) Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data. Magn Reson Med 57:353\u2013361. https:\/\/doi.org\/10.1002\/mrm.21131","journal-title":"Magn Reson Med"},{"key":"704_CR39","doi-asserted-by":"publisher","first-page":"2411","DOI":"10.1109\/TMI.2024.3357799","volume":"43","author":"NJ Smith","year":"2024","unstructured":"Smith NJ, Newton DT, Gunderman D et al (2024) A comparison of arterial input function interpolation methods for Patlak plot analysis of 68Ga-PSMA-11 PET prostate cancer studies. IEEE Trans Med Imaging 43:2411\u20132419. https:\/\/doi.org\/10.1109\/TMI.2024.3357799","journal-title":"IEEE Trans Med Imaging"},{"key":"704_CR40","doi-asserted-by":"publisher","DOI":"10.3389\/fradi.2023.1168901","volume":"3","author":"C Wu","year":"2023","unstructured":"Wu C, Wang N, Gaddam S et al (2023) Retrospective quantification of clinical abdominal DCE-MRI using pharmacokinetics-informed deep learning: a proof-of-concept study. Front Radiol 3:1168901. https:\/\/doi.org\/10.3389\/fradi.2023.1168901","journal-title":"Front Radiol"},{"key":"704_CR41","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1002\/jmri.25171","volume":"44","author":"O Bane","year":"2016","unstructured":"Bane O, Wagner M, Zhang JL et al (2016) Assessment of renal function using intravoxel incoherent motion diffusion-weighted imaging and dynamic contrast-enhanced MRI. J Magn Reson Imaging 44:317\u2013326. https:\/\/doi.org\/10.1002\/jmri.25171","journal-title":"J Magn Reson Imaging"},{"key":"704_CR42","volume":"4","author":"H Kim","year":"2018","unstructured":"Kim H (2018) Variability in quantitative DCE-MRI: sources and solutions. J Nat Sci 4:e484","journal-title":"J Nat Sci"},{"key":"704_CR43","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1002\/jmri.20393","volume":"22","author":"JJ Chen","year":"2005","unstructured":"Chen JJ, Smith MR, Frayne R (2005) The impact of partial-volume effects in dynamic susceptibility contrast magnetic resonance perfusion imaging. J Magn Reson Imaging 22:390\u2013399. https:\/\/doi.org\/10.1002\/jmri.20393","journal-title":"J Magn Reson Imaging"},{"key":"704_CR44","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1148\/radiol.11101664","volume":"260","author":"A Yamamoto","year":"2011","unstructured":"Yamamoto A, Zhang JL, Rusinek H et al (2011) Quantitative evaluation of acute renal transplant dysfunction with low-dose three-dimensional MR renography. Radiology 260:781\u2013789. https:\/\/doi.org\/10.1148\/radiol.11101664","journal-title":"Radiology"},{"key":"704_CR45","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/ndt\/gfac254","volume":"38","author":"RT Gansevoort","year":"2023","unstructured":"Gansevoort RT, Anders H-J, Cozzolino M et al (2023) What should European nephrology do with the new CKD-EPI equation? Nephrol Dial Transplant 38:1\u20136. https:\/\/doi.org\/10.1093\/ndt\/gfac254","journal-title":"Nephrol Dial Transplant"},{"key":"704_CR46","doi-asserted-by":"publisher","first-page":"1","DOI":"10.23750\/abm.v91i4.9304","volume":"91","author":"C Maioli","year":"2020","unstructured":"Maioli C, Mangano M, Conte F et al (2020) The ideal marker for measuring GFR: what are we looking for? Acta Biomed 91:1\u20138. https:\/\/doi.org\/10.23750\/abm.v91i4.9304","journal-title":"Acta Biomed"},{"key":"704_CR47","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1002\/mrm.10080","volume":"47","author":"DL Buckley","year":"2002","unstructured":"Buckley DL (2002) Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI. Magn Reson Med 47:601\u2013606. https:\/\/doi.org\/10.1002\/mrm.10080","journal-title":"Magn Reson Med"},{"key":"704_CR48","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1002\/jmri.27167","volume":"53","author":"A de Boer","year":"2021","unstructured":"de Boer A, Harteveld AA, Stemkens B et al (2021) Multiparametric renal MRI: an intrasubject test\u2013retest repeatability study. J Magn Reson Imaging 53:859\u2013873. https:\/\/doi.org\/10.1002\/jmri.27167","journal-title":"J Magn Reson Imaging"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00704-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-026-00704-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00704-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T13:19:13Z","timestamp":1776777553000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41747-026-00704-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,21]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["704"],"URL":"https:\/\/doi.org\/10.1186\/s41747-026-00704-3","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,21]]},"assertion":[{"value":"27 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Review Board (IRB) of the Icahn School of Medicine at Mount Sinai (STUDY-18-00374, approved 6\/12\/2018).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from all participants prior to inclusion in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"BK is affiliated with Siemens Healthcare. The remaining authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"49"}}