{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T18:57:36Z","timestamp":1793041056148,"version":"4.5.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Deep learning-based noise reduction enhances image quality, overcoming the tradeoff among acquisition time, spatial resolution, and signal-to-noise ratio (SNR). We implemented deep learning reconstruction (DLR) into a 1.5-T musculoskeletal (MSK) magnetic resonance imaging (MRI) protocol to improve image quality without compromising SNR.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      We retrospectively analyzed 39 MRI examinations performed on a 1.5-T scanner using standard-resolution (SR) sequences and sequences with higher resolution reconstructed with DLR (HR-DLR). Exams of the knees, shoulders, ankles, and hips were evaluated. The included sequences were: three-dimensional T2-weighted fast advanced spin-echo; T1-weighted and proton density-weighted fast spin-echo. One expert reader and two junior readers in agreement evaluated the visibility of various structures using a 5-point Likert scale in a blind manner. A fourth reader estimated the SNR and contrast-to-noise ratio (CNR) in bone and muscle. A mixed model was used to compare HR-DLR\n                      <jats:italic>versus<\/jats:italic>\n                      SR measures. The agreement between radiologists was assessed with the Kendall \u03c4 coefficient.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The HR-DLR sequences globally had a smaller pixel size and shorter acquisition time. A good inter-reader agreement was obtained for SR sequences (0.613 \u2264 \u03c4\u2009\u2264\u20090.788) and even higher levels of agreement for HR-DLR sequences (0.682 \u2264 \u03c4\u2009\u2264\u20090.961). All the structures had higher or similar Likert scores in HR-DLR sequences (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), regardless of joint and sequence contrast. Apparent SNR and CNR of HR-DLR and SR were similar.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Incorporating DLR into 1.5-T MSK MRI protocols enhances resolution and maintains SNR and CNR, improving MSK structure visualization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Relevance statement<\/jats:title>\n                    <jats:p>This study demonstrated the effectiveness of deep learning reconstruction in improving the efficiency of 1.5-T musculoskeletal MRI exams. Despite shorter acquisition times, the visibility of key MSK structures was consistently rated as superior or similar in higher-resolution images with DLR.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:list list-type=\"bullet\">\n                        <jats:list-item>\n                          <jats:p>MRI is one of the primary diagnostic tools for evaluating MSK injuries and disorders.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Deep learning reconstruction (DLR) implemented in a 1.5-T MSK protocol improved resolution, still preserving SNR and CNR.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>Higher scores were assigned by different raters to the DLR images, showing image quality improvement.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-026-00743-w","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T13:07:38Z","timestamp":1779973658000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Enhancing resolution and image quality in musculoskeletal MRI using deep learning reconstruction"],"prefix":"10.1186","volume":"10","author":[{"given":"Marco","family":"Porta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Agresti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7848-1711","authenticated-orcid":false,"given":"Maria Marcella","family":"Lagan\u00e0","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Orofino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Pangaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Carapella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pietro Andrea","family":"Bonaffini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Bernasconi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eugenio Annibale","family":"Genovese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandro","family":"Sironi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Aliprandi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"key":"743_CR1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.230531","volume":"308","author":"DB Sneag","year":"2023","unstructured":"Sneag DB, Abel F, Potter HG et al (2023) MRI advancements in musculoskeletal clinical and research practice. Radiology 308:e230531","journal-title":"Radiology"},{"key":"743_CR2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.230615","volume":"308","author":"MP Recht","year":"2023","unstructured":"Recht MP, White LM, Fritz J, Resnick DL (2023) Advances in musculoskeletal imaging: recent developments and predictions for the future. Radiology 308:e230615","journal-title":"Radiology"},{"key":"743_CR3","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1148\/radiol.220634","volume":"306","author":"R Kijowski","year":"2023","unstructured":"Kijowski R, Fritz J (2023) Emerging technology in musculoskeletal MRI and CT. Radiology 306:6\u201319","journal-title":"Radiology"},{"key":"743_CR4","doi-asserted-by":"publisher","first-page":"4736","DOI":"10.1007\/s00330-025-11423-5","volume":"35","author":"SJ Fransen","year":"2025","unstructured":"Fransen SJ, Roest C, Simonis FFJ et al (2025) The scientific evidence of commercial AI products for MRI acceleration: a systematic review. Eur Radiol 35:4736\u20134746","journal-title":"Eur Radiol"},{"key":"743_CR5","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s41747-024-00422-8","volume":"8","author":"S Gitto","year":"2024","unstructured":"Gitto S, Serpi F, Albano D et al (2024) AI applications in musculoskeletal imaging: a narrative review. Eur Radiol Exp 8:22","journal-title":"Eur Radiol Exp"},{"key":"743_CR6","doi-asserted-by":"publisher","first-page":"718","DOI":"10.2214\/AJR.20.22902","volume":"216","author":"J Fritz","year":"2021","unstructured":"Fritz J, Guggenberger R, Grande FD (2021) Magnetic resonance imaging\u2013based grading of cartilaginous bone tumors: added value of quantitative texture analysis. AJR Am J Roentgenol 216:718\u2013733","journal-title":"AJR Am J Roentgenol"},{"key":"743_CR7","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1016\/S0730-725X(03)00202-9","volume":"21","author":"WE Kwok","year":"2003","unstructured":"Kwok WE, Zhong J, You Z et al (2003) A four-element phased array coil for high resolution and parallel MR imaging of the knee. Magn Reson Imaging 21:961\u2013967","journal-title":"Magn Reson Imaging"},{"key":"743_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2020.109430","volume":"134","author":"T Ueda","year":"2021","unstructured":"Ueda T, Ohno Y, Yamamoto K et al (2021) Compressed sensing and deep learning reconstruction for women\u2019s pelvic MRI denoising: utility for improving image quality and examination time in routine clinical practice. Eur J Radiol 134:109430","journal-title":"Eur J Radiol"},{"key":"743_CR9","doi-asserted-by":"publisher","first-page":"e443","DOI":"10.5114\/pjr\/192822","volume":"89","author":"G Foti","year":"2024","unstructured":"Foti G, Longo C (2024) Deep learning and AI in reducing magnetic resonance imaging scanning time: advantages and pitfalls in clinical practice. Pol J Radiol 89:e443\u2013e451","journal-title":"Pol J Radiol"},{"key":"743_CR10","doi-asserted-by":"publisher","first-page":"2585","DOI":"10.1007\/s00256-024-04679-3","volume":"53","author":"HP Do","year":"2024","unstructured":"Do HP, Lockard CA, Berkeley D et al (2024) Improved resolution and image quality of musculoskeletal magnetic resonance imaging using deep learning-based denoising reconstruction: a prospective clinical study. Skeletal Radiol 53:2585\u20132596","journal-title":"Skeletal Radiol"},{"key":"743_CR11","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/s41747-018-0061-6","volume":"2","author":"F Pesapane","year":"2018","unstructured":"Pesapane F, Codari M, Sardanelli F (2018) Artificial intelligence in medical imaging: threat or opportunity? Radiologists again at the forefront of innovation in medicine. Eur Radiol Exp 2:35","journal-title":"Eur Radiol Exp"},{"key":"743_CR12","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s41747-025-00562-5","volume":"9","author":"L Melazzini","year":"2025","unstructured":"Melazzini L, Bortolotto C, Brizzi L et al (2025) AI for image quality and patient safety in CT and MRI. Eur Radiol Exp 9:28","journal-title":"Eur Radiol Exp"},{"key":"743_CR13","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.240516","volume":"314","author":"D Mastrodicasa","year":"2025","unstructured":"Mastrodicasa D, van Assen M, Huisman M et al (2025) Use of AI in cardiac CT and MRI: a scientific statement from the ESCR, EuSoMII, NASCI, SCCT, SCMR, SIIM, and RSNA. Radiology 314:e240516","journal-title":"Radiology"},{"key":"743_CR14","doi-asserted-by":"publisher","first-page":"506","DOI":"10.2214\/AJR.21.26577","volume":"218","author":"S Hahn","year":"2022","unstructured":"Hahn S, Yi J, Lee H-J et al (2022) Image quality and diagnostic performance of accelerated shoulder MRI with deep learning\u2013based reconstruction. AJR Am J Roentgenol 218:506\u2013516","journal-title":"AJR Am J Roentgenol"},{"key":"743_CR15","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1007\/s00256-023-04321-8","volume":"52","author":"S Hahn","year":"2023","unstructured":"Hahn S, Yi J, Lee H-J et al (2023) Comparison of deep learning-based reconstruction of PROPELLER shoulder MRI with conventional reconstruction. Skeletal Radiol 52:1545\u20131555","journal-title":"Skeletal Radiol"},{"key":"743_CR16","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.mri.2022.08.004","volume":"94","author":"Y Obama","year":"2022","unstructured":"Obama Y, Ohno Y, Yamamoto K et al (2022) MR imaging for shoulder diseases: effect of compressed sensing and deep learning reconstruction on examination time and imaging quality compared with that of parallel imaging. Magn Reson Imaging 94:56\u201363","journal-title":"Magn Reson Imaging"},{"key":"743_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110531","volume":"156","author":"N Kashiwagi","year":"2022","unstructured":"Kashiwagi N, Sakai M, Tsukabe A et al (2022) Ultrafast cervical spine MRI protocol using deep learning-based reconstruction: diagnostic equivalence to a conventional protocol. Eur J Radiol 156:110531","journal-title":"Eur J Radiol"},{"key":"743_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111451","volume":"175","author":"Y Xie","year":"2024","unstructured":"Xie Y, Li X, Hu Y et al (2024) Deep learning reconstruction for turbo spin echo to prospectively accelerate ankle MRI: a multi-reader study. Eur J Radiol 175:111451","journal-title":"Eur J Radiol"},{"key":"743_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/s12880-023-00962-2","volume":"23","author":"H Akai","year":"2023","unstructured":"Akai H, Yasaka K, Sugawara H et al (2023) Acceleration of knee magnetic resonance imaging using a combination of compressed sensing and commercially available deep learning reconstruction: a preliminary study. BMC Med Imaging 23:5","journal-title":"BMC Med Imaging"},{"key":"743_CR20","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1016\/j.crad.2024.03.002","volume":"79","author":"H Akai","year":"2024","unstructured":"Akai H, Yasaka K, Sugawara H et al (2024) Faster acquisition of magnetic resonance imaging sequences of the knee via deep learning reconstruction: a volunteer study. Clin Radiol 79:453\u2013459","journal-title":"Clin Radiol"},{"key":"743_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111471","volume":"175","author":"J Yi","year":"2024","unstructured":"Yi J, Hahn S, Lee H-J et al (2024) Thin-slice elbow MRI with deep learning reconstruction: superior diagnostic performance of elbow ligament pathologies. Eur J Radiol 175:111471","journal-title":"Eur J Radiol"},{"key":"743_CR22","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1007\/s11547-024-01787-x","volume":"129","author":"A Estler","year":"2024","unstructured":"Estler A, Hauser T-K, Brunn\u00e9e M et al (2024) Deep learning-accelerated image reconstruction in back pain-MRI imaging: reduction of acquisition time and improvement of image quality. Radiol Med 129:478\u2013487","journal-title":"Radiol Med"},{"key":"743_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111587","volume":"178","author":"M Hokamura","year":"2024","unstructured":"Hokamura M, Nakaura T, Yoshida N et al (2024) Super-resolution deep learning reconstruction approach for enhanced visualization in lumbar spine MR bone imaging. Eur J Radiol 178:111587","journal-title":"Eur J Radiol"},{"key":"743_CR24","doi-asserted-by":"publisher","first-page":"353","DOI":"10.2463\/mrms.mp.2022-0020","volume":"22","author":"H Akai","year":"2022","unstructured":"Akai H, Yasaka K, Sugawara H et al (2022) Commercially available deep-learning-reconstruction of MR imaging of the knee at 1.5T has higher image quality than conventionally-reconstructed Imaging at 3T: a normal volunteer study. Magn Reson Med Sci 22:353\u2013360","journal-title":"Magn Reson Med Sci"},{"key":"743_CR25","doi-asserted-by":"publisher","DOI":"10.1148\/rg.220133","volume":"43","author":"S Kiryu","year":"2023","unstructured":"Kiryu S, Akai H, Yasaka K et al (2023) Clinical impact of deep learning reconstruction in MRI. Radiographics 43:e220133","journal-title":"Radiographics"},{"key":"743_CR26","doi-asserted-by":"publisher","first-page":"195","DOI":"10.2463\/mrms.mp.2019-0018","volume":"19","author":"M Kidoh","year":"2019","unstructured":"Kidoh M, Shinoda K, Kitajima M et al (2019) Deep learning based noise reduction for brain MR imaging: tests on phantoms and healthy volunteers. Magn Reson Med Sci 19:195\u2013206","journal-title":"Magn Reson Med Sci"},{"key":"743_CR27","doi-asserted-by":"crossref","unstructured":"Abdulaal OM, Rainford L, MacMahon PJ et al (2021) Evaluation of optimised 3D turbo spin echo and gradient echo MR pulse sequences of the knee at 3T and 1.5T. Radiography (Lond) 27:389\u2013397","DOI":"10.1016\/j.radi.2020.09.020"},{"key":"743_CR28","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.bspc.2011.06.003","volume":"7","author":"L Griffanti","year":"2012","unstructured":"Griffanti L, Baglio F, Preti MG et al (2012) Signal-to-noise ratio of diffusion weighted magnetic resonance imaging: estimation methods and in vivo application to spinal cord. Biomed Signal Process Control 7:285\u2013294","journal-title":"Biomed Signal Process Control"},{"key":"743_CR29","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1002\/mrm.29249","volume":"88","author":"J Cohen-Adad","year":"2022","unstructured":"Cohen-Adad J, Alonso-Ortiz E, Alley S et al (2022) Comparison of multicenter MRI protocols for visualizing the spinal cord gray matter. Magn Reson Med 88:849\u2013859","journal-title":"Magn Reson Med"},{"key":"743_CR30","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174","journal-title":"Biometrics"},{"key":"743_CR31","doi-asserted-by":"publisher","DOI":"10.1148\/ryai.2021200278","volume":"3","author":"KM Koch","year":"2021","unstructured":"Koch KM, Sherafati M, Arpinar VE et al (2021) Analysis and evaluation of a deep learning reconstruction approach with denoising for orthopedic MRI. Radiol Artif Intell 3:e200278","journal-title":"Radiol Artif Intell"},{"key":"743_CR32","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1097\/RCT.0000000000001418","volume":"47","author":"K Shiraishi","year":"2023","unstructured":"Shiraishi K, Nakaura T, Uetani H et al (2023) Combination use of compressed sensing and deep learning for shoulder magnetic resonance imaging with various sequences. J Comput Assist Tomogr 47:277","journal-title":"J Comput Assist Tomogr"},{"key":"743_CR33","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1097\/RLI.0000000000001093","volume":"59","author":"R Donners","year":"2024","unstructured":"Donners R, Vosshenrich J, Segeroth M et al (2024) Deep learning reconstructed new-generation 0.55 T MRI of the knee\u2014a prospective comparison with conventional 3 T MRI. Invest Radiol 59:823","journal-title":"Invest Radiol"},{"key":"743_CR34","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1148\/radiol.204097","volume":"303","author":"T Ueda","year":"2022","unstructured":"Ueda T, Ohno Y, Yamamoto K et al (2022) Deep learning reconstruction of diffusion-weighted MRI improves image quality for prostatic imaging. Radiology 303:373\u2013381","journal-title":"Radiology"},{"key":"743_CR35","doi-asserted-by":"publisher","first-page":"e13","DOI":"10.1016\/j.crad.2022.08.127","volume":"78","author":"T Tajima","year":"2023","unstructured":"Tajima T, Akai H, Yasaka K et al (2023) Usefulness of deep learning-based noise reduction for 1.5 T MRI brain images. Clin Radiol 78:e13\u2013e21","journal-title":"Clin Radiol"},{"key":"743_CR36","first-page":"455","volume":"43","author":"M Tanabe","year":"2025","unstructured":"Tanabe M, Kawano Y, Inoue A et al (2025) Image quality in three-dimensional (3D) contrast-enhanced dynamic magnetic resonance imaging of the abdomen using deep learning denoising technique: intraindividual comparison between T1-weighted sequences with compressed sensing and with a modified Fast 3D mode wheel. Jpn J Radiol 43:455\u2013462","journal-title":"Jpn J Radiol"},{"key":"743_CR37","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1177\/0846537119900469","volume":"72","author":"Y Yokota","year":"2021","unstructured":"Yokota Y, Takeda C, Kidoh M et al (2021) Effects of deep learning reconstruction technique in high-resolution non-contrast magnetic resonance coronary angiography at a 3-Tesla machine. Can Assoc Radiol J 72:120\u2013127","journal-title":"Can Assoc Radiol J"},{"key":"743_CR38","doi-asserted-by":"crossref","unstructured":"Markhardt BK, Huang BK, Spiker AM, Chang EY (2022) Interpretation of cartilage damage at routine clinical MRI: how to match arthroscopic findings. Radiographics. 42:1457\u20131473","DOI":"10.1148\/rg.220051"},{"key":"743_CR39","doi-asserted-by":"crossref","unstructured":"Strickland C, Ibrahim M, McCarty E (2024) Imaging of cartilage damage. J Cartil Jt Preserv 4:100149","DOI":"10.1016\/j.jcjp.2023.100149"},{"key":"743_CR40","doi-asserted-by":"publisher","first-page":"W317","DOI":"10.2214\/AJR.16.17708","volume":"209","author":"CL White","year":"2017","unstructured":"White CL, Chauvin NA, Waryasz GR et al (2017) MRI of native knee cartilage delamination injuries. AJR Am J Roentgenol 209:W317\u2013W321","journal-title":"AJR Am J Roentgenol"},{"key":"743_CR41","doi-asserted-by":"crossref","unstructured":"Martino G, Silvestri E, Orlandi D et al (2022) Shoulder calcific tendinopathy. In: Martino F, Silvestri E, Orlandi D (eds) Musculoskeletal ultrasound in orthopedic and rheumatic disease in adults. Springer, Cham, pp 129\u2013136","DOI":"10.1007\/978-3-030-91202-4_15"},{"key":"743_CR42","doi-asserted-by":"crossref","unstructured":"Xie Y, Tao H, Xiangwen L et al (2024) Prospective comparison of standard and deep learning\u2013reconstructed turbo spin-echo MRI of the shoulder. Radiology 310:e231405","DOI":"10.1148\/radiol.231405"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00743-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-026-00743-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00743-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T13:07:41Z","timestamp":1779973661000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41747-026-00743-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["743"],"URL":"https:\/\/doi.org\/10.1186\/s41747-026-00743-w","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]},"assertion":[{"value":"28 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 April 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 May 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical Committee approval was obtained (Research Ethics Committee of the University of Insubria, approval number: 0047899; Approval date: May 6, 2025).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The images were irreversibly anonymized and retrospectively analyzed, so written informed consent was waived.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"MML, SO, and SP are employees of Canon Medical Systems, Italy. MML is also a member of the Scientific Editorial Board of\n                      European Radiology Experimental\n                      (section: Neuro and head\/neck) and, as such, did not participate in the selection or review processes for this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"78"}}