{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T10:04:45Z","timestamp":1790762685325,"version":"4.1.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>\n                      To evaluate the accuracy of iodinated contrast media (ICM) and saline flush volumes delivered by a piston- and a peristaltic-based injector in an\n                      <jats:italic>in vitro<\/jats:italic>\n                      study.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>Seven clinical injection protocols, ranging from pediatric to bariatric indications and incorporating varying flow rates, ICM volumes, saline volumes, and dilution ratios, were tested. Identical prescriptions were programmed into a piston-based injector and a peristaltic-based injector. Injections were performed into vials. Calibration samples (5\u201320 mgI\/mL) were scanned on a multi-slice CT scanner to generate a calibration curve relating CT number to iodine concentration. The saline test volume and combined ICM + saline flush volume were measured for each injection. CT numbers of mixtures were converted to iodine concentration using the calibration curve, and delivered ICM and saline volumes were calculated. Percent errors between expected and measured volumes were determined. A Wilcoxon signed-rank test assessed statistical significance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      For the peristaltic-based injector, ICM volume error ranged from 4.0% to 10.0% and saline flush error from 0.6% to 9.2%. For the piston-based injector, ICM volume error ranged from 9.9% to 40.0% and saline flush error from 1.5% to 50.2%. Differences between expected and delivered volumes were statistically significant across protocols (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.031\/=\u20090.035), except for peristaltic saline flush protocols (Ped 12\u2009mL (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.094), Adult 170\u2009mL (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.156), and High Flow (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.093)).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Both injectors delivered excess ICM while saline flush volumes showed variability. These findings underscore the importance of performance verification to ensure accurate and consistent contrast delivery in clinical practice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Question<\/jats:italic>\n                      <\/jats:bold>\n                      Automated injectors often delivered more contrast than expected.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Findings<\/jats:italic>\n                      <\/jats:bold>\n                      Both systems often underdelivered saline with some instances of overdelivery.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Relevance statement<\/jats:italic>\n                      <\/jats:bold>\n                      Unrecognized variability in contrast and saline delivery across different injection settings may affect enhancement consistency, contrast exposure, and diagnostic reliability. Broader injector performance evaluation across clinically used protocols and clinically simulated setups may improve CT practice.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-026-00785-0","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T09:35:32Z","timestamp":1790760932000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of iodinated contrast and saline delivery using a piston-driven and a peristaltic power injector in CT\u2014an in vitro study"],"prefix":"10.1186","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6994-2707","authenticated-orcid":false,"given":"Zahra","family":"Alyani Nezhad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aria M.","family":"Salyapongse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Courtney J.","family":"Goetsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel M.","family":"Bladorn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carrie M.","family":"Bartels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelsey L.","family":"Schluter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin G.","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe V.","family":"Toia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy P.","family":"Szczykutowicz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"key":"785_CR1","doi-asserted-by":"publisher","first-page":"1641","DOI":"10.1021\/cr200358s","volume":"113","author":"H Lusic","year":"2013","unstructured":"Lusic H, Grinstaff MW (2013) X-ray-computed tomography contrast agents. Chem Rev 113:1641\u20131666. https:\/\/doi.org\/10.1021\/cr200358s","journal-title":"Chem Rev"},{"key":"785_CR2","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1148\/radiol.10090908","volume":"256","author":"KT Bae","year":"2010","unstructured":"Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32\u201361. https:\/\/doi.org\/10.1148\/radiol.10090908","journal-title":"Radiology"},{"key":"785_CR3","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.1097\/00004728-198611000-00020","volume":"10","author":"WP Shuman","year":"1986","unstructured":"Shuman WP, Adam JL, Schoenecker SA, Tazioli PR, Moss AA (1986) Use of a power injector during dynamic computed tomography. J Comput Assist Tomogr 10:1000\u20131002","journal-title":"J Comput Assist Tomogr"},{"key":"785_CR4","first-page":"344","volume":"90","author":"A Chaya","year":"2019","unstructured":"Chaya A, Jost G, Endrikat J (2019) Piston-based vs peristaltic pump-based CT injector systems. Radiol Technol 90:344\u2013353","journal-title":"Radiol Technol"},{"key":"785_CR5","doi-asserted-by":"publisher","first-page":"2","DOI":"10.4103\/0971-3026.150105","volume":"25","author":"IK Indrajit","year":"2015","unstructured":"Indrajit IK, Sivasankar R, D\u2019Souza J et al (2015) Pressure injectors for radiologists: a review and what is new. Indian J Radiol Imaging 25:2\u201310. https:\/\/doi.org\/10.4103\/0971-3026.150105","journal-title":"Indian J Radiol Imaging"},{"key":"785_CR6","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1186\/s13244-024-01750-4","volume":"15","author":"MC McDermott","year":"2024","unstructured":"McDermott MC, Wildberger JE, Bae KT (2024) Critical but commonly neglected factors that affect contrast medium administration in CT. Insights Imaging 15:219. https:\/\/doi.org\/10.1186\/s13244-024-01750-4","journal-title":"Insights Imaging"},{"key":"785_CR7","doi-asserted-by":"crossref","unstructured":"Alyani Nezhad Z, Toia G, Rose S, Bladorn R, Szczykutowicz T (2026) Factors affecting contrast enhancement in computed tomography imaging. Radiographics 46:e250192","DOI":"10.1148\/rg.250192"},{"key":"785_CR8","doi-asserted-by":"publisher","unstructured":"Saade C, Saab S, El-Sakakini J et al (2025) Comparing peristaltic and direct-drive contrast injection systems for thoracic computed tomography (CT): effects on dose, image quality, and pathology. Cureus. https:\/\/doi.org\/10.7759\/cureus.76814","DOI":"10.7759\/cureus.76814"},{"key":"785_CR9","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1007\/BF01372228","volume":"26","author":"SC Kaste","year":"1996","unstructured":"Kaste SC, Young CW (1996) Safe use of power injectors with central and peripheral venous access devices for pediatric CT. Pediatr Radiol 26:499\u2013501","journal-title":"Pediatr Radiol"},{"key":"785_CR10","doi-asserted-by":"publisher","first-page":"20190868","DOI":"10.1259\/bjr.20190868","volume":"93","author":"M McDermott","year":"2020","unstructured":"McDermott M, Kemper C, Barone W, Jost G, Endrikat J (2020) Impact of CT injector technology and contrast media viscosity on vascular enhancement: evaluation in a circulation phantom. Br J Radiol 93:20190868. https:\/\/doi.org\/10.1259\/bjr.20190868","journal-title":"Br J Radiol"},{"key":"785_CR11","doi-asserted-by":"publisher","first-page":"2340","DOI":"10.1016\/j.acra.2023.05.038","volume":"30","author":"GV Toia","year":"2023","unstructured":"Toia GV, Rose SD, Brown Z et al (2023) Consumable material waste and workflow efficiency comparison between multi-use syringeless and single-use syringe-based injectors in computed tomography. Acad Radiol 30:2340\u20132349","journal-title":"Acad Radiol"},{"key":"785_CR12","doi-asserted-by":"crossref","unstructured":"Szczykutowicz T (2020) The CT handbook: optimizing protocols for today\u2019s feature-rich scanners. Medical Physics, Madison, pp 286\u2013289","DOI":"10.54947\/9780944838532"},{"key":"785_CR13","unstructured":"Brown TL, LeMay HE, Bursten BE, Murphy C (2017) Chemistry: the central science, 14th edn. Pearson, Chapter 4 Section 4.5 Upper Saddle River, NJ"},{"key":"785_CR14","unstructured":"Graybill FA (1976) Theory and application of the linear model. Duxbury Press, Belmont"},{"key":"785_CR15","unstructured":"Tariq RA, Vashisht R, Sinha A, Scherbak Y (2018) Medication dispensing errors and prevention. StatPearls Publishing, Treasure Island, FL"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00785-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-026-00785-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00785-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T09:35:34Z","timestamp":1790760934000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41747-026-00785-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["785"],"URL":"https:\/\/doi.org\/10.1186\/s41747-026-00785-0","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]},"assertion":[{"value":"26 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 June 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 June 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"ZAN, AMS, RRB, KLS, CRB and CJG declare no conflicts of interest. MGW: HistoSonics Inc. (consultant, research support), Siemens Healthineers (research support), and Canon Medical (research support). TPS receives research support from Canon Medical Systems and GE HealthCare, consulting fees from Alara Imaging, Imalogix, Aidoc, and Asto CT\/Leo Cancer Care; royalties from Medical Physics Publishing and royalties related to intellectual property from Qaelum; founder of RadUnity. GVT receives an institutional grant from Canon Medical Systems.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"143"}}