{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T14:53:13Z","timestamp":1791384793989,"version":"4.3.3"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aimed to define the minimum positron emission tomography (PET) acquisition time for chest PET\/magnetic resonance imaging (MRI), providing image quality and lesion detectability comparable to a 20-min reference.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      In this retrospective study, list-mode data from 101 patients undergoing chest\n                      <jats:sup>18<\/jats:sup>\n                      F-fluorodeoxyglucose (\n                      <jats:sup>18<\/jats:sup>\n                      F-FDG) PET\/MRI on a 3-T PET\/MRI system were reconstructed to simulate 10 acquisition times (0.5\u201320\u2009min). Two readers assessed subjective image quality using a 5-point Likert scale. Quantitative parameters, including maximum, mean of the lesion standardized uptake value (L_SUV\n                      <jats:sub>max<\/jats:sub>\n                      , L_SUV\n                      <jats:sub>mean<\/jats:sub>\n                      ), image noise ratio (INR), and lesion-to-background ratio (LBR), were measured. Lesion detectability was defined as the miss rate relative to lesions visible on the 20-min reference acquisition.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In 101 patients, 283 lesions were identified. Subjective scores increased from a median of 2 (interquartile range 2\u20132) at 0.5\u2009min to 5 (5\u20135) at 7\u2009min (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), then plateaued (7\u201320\u2009min; all\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20091.000). L_SUV\n                      <jats:sub>max<\/jats:sub>\n                      , L_SUV\n                      <jats:sub>mean<\/jats:sub>\n                      , and LBR inversely correlated with scan duration (all\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). L_SUV\n                      <jats:sub>mean<\/jats:sub>\n                      stabilized at 3\u2009min (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20091.000), while L_SUV\n                      <jats:sub>max<\/jats:sub>\n                      \/LBR stabilized at 5\u2009min (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20091.000). INR required 10\u2009min (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2265\u20090.054). Lesion miss rates increased time dependently, from 0% at 15\u2009min to 7.77% at 0.5\u2009min.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      A 7-min acquisition time provided subjective quality and detectability comparable to the 20-min protocol, supporting routine use. For quantitative assessments, 3\u20135\u2009min sufficed, and patients with shorter\n                      <jats:sup>18<\/jats:sup>\n                      F-FDG uptake or larger lesions may be adequately assessed with 2\u2009min.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Question<\/jats:italic>\n                      <\/jats:bold>\n                      What is the minimum PET acquisition time for chest 18F-FDG PET\/MRI that maintains image quality and lesion detectability equivalent to a 20\u2011min reference?\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Findings<\/jats:italic>\n                      <\/jats:bold>\n                      A 7\u2011min PET acquisition matches 20\u2011min image quality and detectability; quantitative parameters stabilize at 3\u20115 min; 2 min suffices for patients with shorter uptake or larger lesions.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Relevance statement<\/jats:italic>\n                      <\/jats:bold>\n                      Reducing PET acquisition time to 7 min enhances patient comfort, reduces motion artifacts, and increases scanner throughput without compromising chest PET\/MRI diagnostic performance, thereby improving patient experience and workflow efficiency. Further clinical validation is needed.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Keywords<\/jats:title>\n                    <jats:p>Fluorodeoxyglucose F18, Magnetic resonance imaging, Patient comfort, Positron emission tomography, Thorax<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-026-00787-y","type":"journal-article","created":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T14:04:03Z","timestamp":1791381843000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optimization of PET acquisition time for thoracic lesions in 18F-FDG PET\/MRI: a retrospective analysis"],"prefix":"10.1186","volume":"10","author":[{"given":"Haifeng","family":"Gu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gang","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianrui","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sui","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Song","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6664-7224","authenticated-orcid":false,"given":"Longjiang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,7]]},"reference":[{"key":"787_CR1","doi-asserted-by":"publisher","first-page":"229","DOI":"10.3322\/caac.21834","volume":"74","author":"F Bray","year":"2024","unstructured":"Bray F, Laversanne M, Sung H et al (2024) Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 74:229\u2013263. https:\/\/doi.org\/10.3322\/caac.21834","journal-title":"CA Cancer J Clin"},{"key":"787_CR2","doi-asserted-by":"publisher","first-page":"5579","DOI":"10.21037\/qims-23-186","volume":"13","author":"N Meng","year":"2023","unstructured":"Meng N, Zhang M, Ren J et al (2023) Quantitative parameters of static imaging and fast kinetics imaging in 18F-FDG total-body PET\/CT for the assessment of histological feature of pulmonary lesions. Quant Imaging Med Surg 13:5579\u20135592. https:\/\/doi.org\/10.21037\/qims-23-186","journal-title":"Quant Imaging Med Surg"},{"key":"787_CR3","doi-asserted-by":"publisher","first-page":"2265","DOI":"10.3390\/cancers16122265","volume":"16","author":"TV Weijer","year":"2024","unstructured":"Weijer TV, van der Meer WL, Moonen RPM et al (2024) Limited additional value of a chest CT in whole-body staging with PET-MRI: a retrospective cohort study. Cancers (Basel) 16:2265. https:\/\/doi.org\/10.3390\/cancers16122265","journal-title":"Cancers"},{"key":"787_CR4","doi-asserted-by":"publisher","first-page":"e761","DOI":"10.1016\/S2352-3026(24)00240-0","volume":"11","author":"K Leuraud","year":"2024","unstructured":"Leuraud K, Laurier D, Gillies M et al (2024) Leukaemia, lymphoma, and multiple myeloma mortality after low-level exposure to ionising radiation in nuclear workers (INWORKS): updated findings from an international cohort study. Lancet Haematol 11:e761\u2013e769. https:\/\/doi.org\/10.1016\/S2352-3026(24)00240-0","journal-title":"Lancet Haematol"},{"key":"787_CR5","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1007\/s00117-013-2604-4","volume":"54","author":"G Sommer","year":"2014","unstructured":"Sommer G, Koenigkam-Santos M, Biederer J, Puderbach M (2014) Role of MRI for detection and characterization of pulmonary nodules. Radiologe 54:470\u2013477. https:\/\/doi.org\/10.1007\/s00117-013-2604-4","journal-title":"Radiologe"},{"key":"787_CR6","doi-asserted-by":"publisher","first-page":"373","DOI":"10.2967\/jnumed.113.129825","volume":"55","author":"P Heusch","year":"2014","unstructured":"Heusch P, Buchbender C, Kohler J et al (2014) Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET\/MR imaging and 18F-FDG PET\/CT. J Nucl Med 55:373\u2013378. https:\/\/doi.org\/10.2967\/jnumed.113.129825","journal-title":"J Nucl Med"},{"key":"787_CR7","doi-asserted-by":"publisher","first-page":"2927","DOI":"10.1007\/s00259-023-06308-y","volume":"50","author":"NHJ Prakken","year":"2023","unstructured":"Prakken NHJ, Besson FL, Borra RJH et al (2023) PET\/MRI in practice: a clinical centre survey endorsed by the European Association of Nuclear Medicine (EANM) and the EANM Forschungs GmbH (EARL). Eur J Nucl Med Mol Imaging 50:2927\u20132934. https:\/\/doi.org\/10.1007\/s00259-023-06308-y","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"787_CR8","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/j.mric.2023.06.002","volume":"31","author":"H Arabi","year":"2023","unstructured":"Arabi H, Zaidi H (2023) Recent advances in positron emission tomography\/magnetic resonance imaging technology. Magn Reson Imaging Clin N Am 31:503\u2013515. https:\/\/doi.org\/10.1016\/j.mric.2023.06.002","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"787_CR9","doi-asserted-by":"publisher","first-page":"896","DOI":"10.2214\/AJR.18.19620","volume":"211","author":"JJ Bailey","year":"2018","unstructured":"Bailey JJ, Jordan EJ, Burke C et al (2018) Does extended PET acquisition in PET\/MRI rectal cancer staging improve results? AJR Am J Roentgenol 211:896\u2013900. https:\/\/doi.org\/10.2214\/AJR.18.19620","journal-title":"AJR Am J Roentgenol"},{"key":"787_CR10","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-020-00322-x","volume":"7","author":"V Murthy","year":"2020","unstructured":"Murthy V, Smith RL, Tao DH et al (2020) 68Ga-PSMA-11 PET\/MRI: determining ideal acquisition times to reduce noise and increase image quality. EJNMMI Phys 7:54. https:\/\/doi.org\/10.1186\/s40658-020-00322-x","journal-title":"EJNMMI Phys"},{"key":"787_CR11","doi-asserted-by":"publisher","first-page":"e0164392","DOI":"10.1371\/journal.pone.0164392","volume":"11","author":"S L\u00fctje","year":"2016","unstructured":"L\u00fctje S, Blex S, Gomez B et al (2016) Optimization of acquisition time of 68Ga-PSMA-ligand PET\/MRI in patients with local and metastatic prostate cancer. PLoS One 11:e0164392. https:\/\/doi.org\/10.1371\/journal.pone.0164392","journal-title":"PLoS One"},{"key":"787_CR12","doi-asserted-by":"publisher","DOI":"10.1186\/s13550-017-0261-8","volume":"7","author":"B Noto","year":"2017","unstructured":"Noto B, B\u00fcther F, Auf der Springe K et al (2017) Impact of PET acquisition durations on image quality and lesion detectability in whole-body 68Ga-PSMA PET-MRI. EJNMMI Res 7:12. https:\/\/doi.org\/10.1186\/s13550-017-0261-8","journal-title":"EJNMMI Res"},{"key":"787_CR13","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1097\/RLI.0000000000000146","volume":"50","author":"H Davison","year":"2015","unstructured":"Davison H, ter Voert EE, de Galiza Barbosa F, Veit-Haibach P, Delso G (2015) Incorporation of time-of-flight information reduces metal artifacts in simultaneous positron emission tomography\/magnetic resonance imaging: a simulation study. Invest Radiol 50:423\u2013429. https:\/\/doi.org\/10.1097\/RLI.0000000000000146","journal-title":"Invest Radiol"},{"key":"787_CR14","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1967\/s002449910333","volume":"19","author":"S Gatidis","year":"2016","unstructured":"Gatidis S, W\u00fcrslin C, Seith F et al (2016) Towards tracer dose reduction in PET studies: simulation of dose reduction by retrospective randomized undersampling of list-mode data. Hell J Nucl Med 19:15\u201318. https:\/\/doi.org\/10.1967\/s002449910333","journal-title":"Hell J Nucl Med"},{"key":"787_CR15","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1097\/RLU.0000000000005526","volume":"49","author":"M Amini","year":"2024","unstructured":"Amini M, Salimi Y, Hajianfar G et al (2024) Fully automated region-specific human-perceptive-equivalent image quality assessment: application to 18F-FDG PET scans. Clin Nucl Med 49:1079\u20131090. https:\/\/doi.org\/10.1097\/RLU.0000000000005526","journal-title":"Clin Nucl Med"},{"key":"787_CR16","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1097\/MNM.0000000000000641","volume":"38","author":"W Xu","year":"2017","unstructured":"Xu W, Yu S, Ma Y, Liu C, Xin J (2017) Effect of different segmentation algorithms on metabolic tumor volume measured on 18F-FDG PET\/CT of cervical primary squamous cell carcinoma. Nucl Med Commun 38:259\u2013265. https:\/\/doi.org\/10.1097\/MNM.0000000000000641","journal-title":"Nucl Med Commun"},{"key":"787_CR17","doi-asserted-by":"publisher","DOI":"10.1186\/s41824-022-00142-5","volume":"6","author":"EM Badawe","year":"2022","unstructured":"Badawe EM, Abdel Gawad H, El-Nagdy MS, Khalil MM (2022) Variations induced by body weight and background lesion normalization in standardized uptake value estimated by F18-FDG PET\/CT. Eur J Hybrid Imaging 6:22. https:\/\/doi.org\/10.1186\/s41824-022-00142-5","journal-title":"Eur J Hybrid Imaging"},{"key":"787_CR18","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1148\/radiol.2019191882","volume":"294","author":"PE Kinahan","year":"2020","unstructured":"Kinahan PE, Perlman ES, Sunderland JJ et al (2020) The QIBA profile for FDG PET\/CT as an imaging biomarker measuring response to cancer therapy. Radiology 294:647\u2013657. https:\/\/doi.org\/10.1148\/radiol.2019191882","journal-title":"Radiology"},{"key":"787_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/s13550-015-0111-5","volume":"5","author":"JM Rogasch","year":"2015","unstructured":"Rogasch JM, Steffen IG, Hofheinz F et al (2015) The association of tumor-to-background ratios and SUVmax deviations related to point spread function and time-of-flight 18F-FDG-PET\/CT reconstruction in colorectal liver metastases. EJNMMI Res 5:31. https:\/\/doi.org\/10.1186\/s13550-015-0111-5","journal-title":"EJNMMI Res"},{"key":"787_CR20","doi-asserted-by":"publisher","DOI":"10.1186\/s40644-016-0086-0","volume":"16","author":"J Yan","year":"2016","unstructured":"Yan J, Schaefferkoette J, Conti M, Townsend D (2016) A method to assess image quality for low-dose PET: analysis of SNR, CNR, bias and image noise. Cancer Imaging 16:26. https:\/\/doi.org\/10.1186\/s40644-016-0086-0","journal-title":"Cancer Imaging"},{"key":"787_CR21","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174. https:\/\/doi.org\/10.2307\/2529310","journal-title":"Biometrics"},{"key":"787_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2023.102584","volume":"109","author":"A Zorz","year":"2023","unstructured":"Zorz A, D\u2019Alessio A, Guida F et al (2023) Impact of patient\u2019s habitus on image quality and quantitative metrics in 18F-FDG PET\/CT images. Phys Med 109:102584. https:\/\/doi.org\/10.1016\/j.ejmp.2023.102584","journal-title":"Phys Med"},{"key":"787_CR23","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.2967\/jnumed.111.101733","volume":"53","author":"MA Lodge","year":"2012","unstructured":"Lodge MA, Chaudhry MA, Wahl RL (2012) Noise considerations for PET quantification using maximum and peak standardized uptake value. J Nucl Med 53:1041\u20131047. https:\/\/doi.org\/10.2967\/jnumed.111.101733","journal-title":"J Nucl Med"},{"key":"787_CR24","doi-asserted-by":"publisher","first-page":"222","DOI":"10.2967\/jnmt.115.161745","volume":"43","author":"G Akamatsu","year":"2015","unstructured":"Akamatsu G, Ikari Y, Nishida H et al (2015) Influence of statistical fluctuation on reproducibility and accuracy of SUVmax and SUVpeak: a phantom study. J Nucl Med Technol 43:222\u2013226. https:\/\/doi.org\/10.2967\/jnmt.115.161745","journal-title":"J Nucl Med Technol"},{"key":"787_CR25","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.ejrad.2017.08.024","volume":"95","author":"S Wampl","year":"2017","unstructured":"Wampl S, Rausch I, Traub-Weidinger T et al (2017) Quantification accuracy of neuro-oncology PET data as a function of emission scan duration in PET\/MR compared to PET\/CT. Eur J Radiol 95:257\u2013264. https:\/\/doi.org\/10.1016\/j.ejrad.2017.08.024","journal-title":"Eur J Radiol"},{"key":"787_CR26","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1364\/josaa.16.000633","volume":"Vis 16","author":"AE Burgess","year":"1999","unstructured":"Burgess AE (1999) The Rose model, revisited. J Opt Soc Am A Opt Image Sci Vis 16:633\u2013646. https:\/\/doi.org\/10.1364\/josaa.16.000633","journal-title":"J Opt Soc Am A Opt Image Sci"},{"key":"787_CR27","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1097\/RLI.0b013e3182823695","volume":"48","author":"V Hartung-Knemeyer","year":"2013","unstructured":"Hartung-Knemeyer V, Beiderwellen KJ, Buchbender C et al (2013) Optimizing positron emission tomography image acquisition protocols in integrated positron emission tomography\/magnetic resonance imaging. Invest Radiol 48:290\u2013294. https:\/\/doi.org\/10.1097\/RLI.0b013e3182823695","journal-title":"Invest Radiol"},{"key":"787_CR28","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1097\/MNM.0000000000000396","volume":"37","author":"H Liu","year":"2016","unstructured":"Liu H, Chen P, Wroblewski K et al (2016) Consistency of metabolic tumor volume of non-small-cell lung cancer primary tumor measured using 18F-FDG PET\/CT at two different tracer uptake times. Nucl Med Commun 37:50\u201356. https:\/\/doi.org\/10.1097\/MNM.0000000000000396","journal-title":"Nucl Med Commun"},{"key":"787_CR29","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1007\/s002590100537","volume":"28","author":"K Kubota","year":"2001","unstructured":"Kubota K, Itoh M, Ozaki K et al (2001) Advantage of delayed whole-body FDG-PET imaging for tumour detection. Eur J Nucl Med 28:696\u2013703. https:\/\/doi.org\/10.1007\/s002590100537","journal-title":"Eur J Nucl Med"},{"key":"787_CR30","doi-asserted-by":"publisher","first-page":"932","DOI":"10.2967\/jnumed.106.035774","volume":"48","author":"M Soret","year":"2007","unstructured":"Soret M, Bacharach SL, Buvat I (2007) Partial-volume effect in PET tumor imaging. J Nucl Med 48:932\u2013945. https:\/\/doi.org\/10.2967\/jnumed.106.035774","journal-title":"J Nucl Med"},{"key":"787_CR31","doi-asserted-by":"publisher","first-page":"6179","DOI":"10.1007\/s00330-023-09580-6","volume":"33","author":"K Jannusch","year":"2023","unstructured":"Jannusch K, Lindemann ME, Bruckmann NM et al (2023) Towards a fast PET\/MRI protocol for breast cancer imaging: maintaining diagnostic confidence while reducing PET and MRI acquisition times. Eur Radiol 33:6179\u20136188. https:\/\/doi.org\/10.1007\/s00330-023-09580-6","journal-title":"Eur Radiol"},{"key":"787_CR32","doi-asserted-by":"publisher","first-page":"e0206573","DOI":"10.1371\/journal.pone.0206573","volume":"13","author":"ME Lindemann","year":"2018","unstructured":"Lindemann ME, Stebner V, Tschischka A et al (2018) Towards fast whole-body PET\/MR: investigation of PET image quality versus reduced PET acquisition times. PLoS One 13:e0206573. https:\/\/doi.org\/10.1371\/journal.pone.0206573","journal-title":"PLoS One"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00787-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-026-00787-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00787-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T14:04:04Z","timestamp":1791381844000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41747-026-00787-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,7]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["787"],"URL":"https:\/\/doi.org\/10.1186\/s41747-026-00787-y","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,7]]},"assertion":[{"value":"25 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was approved by the Institutional Review Board of Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University (2025DZKY-047-01) on April 29, 2025.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was waived by the Institutional Review Board for this retrospective analysis. However, written consent was obtained from all relevant participants for images that could potentially identify individuals (\n                      e.g\n                      ., Fig.\u00a0\n                      \n                      ).","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that there are no conflicts of interest.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"151"}}