{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T08:47:33Z","timestamp":1791881253905,"version":"4.3.4"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T00:00:00Z","timestamp":1791763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T00:00:00Z","timestamp":1791763200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009398","name":"Medizinische Fakult\u00e4t, RWTH Aachen University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100009398","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000780","name":"European Commission","doi-asserted-by":"publisher","award":["101250682"],"award-info":[{"award-number":["101250682"]}],"id":[{"id":"10.13039\/501100000780","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To develop and validate a phase-adaptive pipeline for automated whole-liver, parenchyma-based quantification of signal intensity-derived liver indices from gadoxetic acid-enhanced MRI without inter-phase co-registration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      In this retrospective, single-center study (2016\u20132025), 9,013 liver MRI examinations were screened, and 3,112 gadoxetic acid-enhanced MRI examinations were identified. The first examination per patient defined the clinical cohort (1,174 patients; mean age, 59.6\u2009\u00b1\u200914 years [range, 4-93 years]; 611 men). A phase-adaptive nnU-Net was trained on 403 and tested on 500 dynamic contrast-enhanced MRI sequences for segmentation of liver parenchyma, intrahepatic non-parenchymal structures, and spleen; paraspinal muscle reference regions were obtained using TotalSegmentator. Segmentation accuracy was assessed against manually corrected reference segmentations generated by a semi-automatic annotation workflow with Dice similarity coefficients. Automated arterial enhancement fraction (AEF), relative liver enhancement (RLE), hepatocellular uptake index (HUI), liver-to-spleen ratio (LSR), and liver-to-muscle ratio (LMR) were compared with manual region-of-interest measurements in a radiological validation cohort (50 patients) using intraclass correlation coefficients and Bland-Altman analysis. Liver indices were compared between patients with cirrhotic and non-cirrhotic livers using the Mann\u2013Whitney\n                      <jats:italic>U<\/jats:italic>\n                      -test.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Liver parenchyma segmentation achieved Dice similarity coefficients of 0.998\u20130.999. Reader-model agreement for the liver indices ranged from 0.936 to 0.977. HUI, LSR, RLE, and LMR were lower in cirrhosis (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), whereas AEF did not differ (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.14).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Phase-adaptive segmentation enables whole-liver quantification of signal intensity-derived liver indices without inter-phase co-registration. The lower hepatobiliary uptake indices in cirrhosis support the plausibility of this approach for scalable quantitative assessment of liver MRI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Question<\/jats:italic>\n                      <\/jats:bold>\n                      Can gadoxetic acid-enhanced liver MRI be quantified automatically across contrast phases without inter-phase co-registration or manual region-of-interest placement in routine clinical imaging?\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Findings<\/jats:italic>\n                      <\/jats:bold>\n                      Phase-adaptive segmentation enabled automated whole-liver quantification with liver Dice coefficients of 0.998\u20130.999 and excellent agreement with manual measurements for five liver indices.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Relevance Statement<\/jats:italic>\n                      <\/jats:bold>\n                      Automated whole-liver quantification from standard gadoxetic acid-enhanced liver MRI provides reproducible, signal-intensity-derived liver indices and reduces dependence on manual region-of-interest measurements in large-scale clinical studies.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-026-00813-z","type":"journal-article","created":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:40:00Z","timestamp":1791826800000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Phase-adaptive automated whole-liver quantification of signal intensity-derived liver indices from gadoxetic acid-enhanced MRI"],"prefix":"10.1186","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0362-3612","authenticated-orcid":false,"given":"Felix","family":"Barajas Ordonez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Westfechtel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fadi","family":"Matar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Lemessa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Wienholt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Truhn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christiane","family":"Kuhl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandra","family":"Barabasch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sven","family":"Nebelung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,12]]},"reference":[{"key":"813_CR1","doi-asserted-by":"publisher","DOI":"10.1038\/srep43347","volume":"7","author":"M Haimerl","year":"2017","unstructured":"Haimerl M, Verloh N, Zeman F et al (2017) Gd-EOB-DTPA-enhanced MRI for evaluation of liver function: comparison between signal-intensity-based indices and T1 relaxometry. Sci Rep 7:43347. https:\/\/doi.org\/10.1038\/srep43347","journal-title":"Sci Rep"},{"key":"813_CR2","doi-asserted-by":"publisher","first-page":"e311","DOI":"10.1016\/j.ejrad.2011.01.020","volume":"80","author":"T Tamada","year":"2011","unstructured":"Tamada T, Ito K, Higaki A et al (2011) Gd-EOB-DTPA-enhanced MR imaging: evaluation of hepatic enhancement effects in normal and cirrhotic livers. Eur J Radiol 80:e311\u2013e316. https:\/\/doi.org\/10.1016\/j.ejrad.2011.01.020","journal-title":"Eur J Radiol"},{"key":"813_CR3","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1148\/radiol.11100586","volume":"260","author":"A Yamada","year":"2011","unstructured":"Yamada A, Hara T, Li F et al (2011) Quantitative evaluation of liver function with use of gadoxetate disodium-enhanced MR imaging. Radiology 260:727\u2013733. https:\/\/doi.org\/10.1148\/radiol.11100586","journal-title":"Radiology"},{"key":"813_CR4","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1007\/s00535-011-0513-8","volume":"47","author":"T Utsunomiya","year":"2012","unstructured":"Utsunomiya T, Shimada M, Hanaoka J et al (2012) Possible utility of MRI using Gd-EOB-DTPA for estimating liver functional reserve. J Gastroenterol 47:470\u2013476. https:\/\/doi.org\/10.1007\/s00535-011-0513-8","journal-title":"J Gastroenterol"},{"key":"813_CR5","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1002\/jmri.23691","volume":"36","author":"A Nishie","year":"2012","unstructured":"Nishie A, Asayama Y, Ishigami K et al (2012) MR prediction of liver fibrosis using a liver-specific contrast agent: superparamagnetic iron oxide versus Gd-EOB-DTPA. Magn Reson Imaging 36:664\u2013671. https:\/\/doi.org\/10.1002\/jmri.23691","journal-title":"Magn Reson Imaging"},{"key":"813_CR6","doi-asserted-by":"publisher","first-page":"W596","DOI":"10.2214\/ajr.12.10048","volume":"201","author":"H-Y Ou","year":"2013","unstructured":"Ou H-Y, Bonekamp S, Bonekamp D et al (2013) MRI arterial enhancement fraction in hepatic fibrosis and cirrhosis. AJR Am J Roentgenol 201:W596\u2013W602. https:\/\/doi.org\/10.2214\/ajr.12.10048","journal-title":"AJR Am J Roentgenol"},{"key":"813_CR7","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-26328-2","volume":"12","author":"L Zbinden","year":"2022","unstructured":"Zbinden L, Catucci D, Suter Y et al (2022) Convolutional neural network for automated segmentation of the liver and its vessels on non-contrast T1 vibe Dixon acquisitions. Sci Rep 12:22059. https:\/\/doi.org\/10.1038\/s41598-022-26328-2","journal-title":"Sci Rep"},{"key":"813_CR8","doi-asserted-by":"publisher","first-page":"720","DOI":"10.3348\/kjr.2021.0892","volume":"23","author":"HJ Park","year":"2022","unstructured":"Park HJ, Yoon JS, Lee SS et al (2022) Deep learning-based assessment of functional liver capacity using gadoxetic acid-enhanced hepatobiliary phase MRI. Korean J Radiol 23:720. https:\/\/doi.org\/10.3348\/kjr.2021.0892","journal-title":"Korean J Radiol"},{"key":"813_CR9","doi-asserted-by":"publisher","unstructured":"Raab F, Strotzer Q, Stroszczynski C et al (2025) Automatic segmentation of liver structures in multi-phase MRI using variants of nnU-Net and Swin UNETR. Sci Rep. https:\/\/doi.org\/10.1038\/s41598-025-07084-5","DOI":"10.1038\/s41598-025-07084-5"},{"key":"813_CR10","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1088\/0031-9155\/52\/6\/001","volume":"52","author":"MV Siebenthal","year":"2007","unstructured":"Siebenthal MV, Sz\u00e9kely G, Gamper U et al (2007) 4D MR imaging of respiratory organ motion and its variability. Phys Med Biol 52:1547\u20131564. https:\/\/doi.org\/10.1088\/0031-9155\/52\/6\/001","journal-title":"Phys Med Biol"},{"key":"813_CR11","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s41747-019-0120-7","volume":"3","author":"KA Hasenstab","year":"2019","unstructured":"Hasenstab KA, Cunha GM, Higaki A et al (2019) Fully automated convolutional neural network-based affine algorithm improves liver registration and lesion co-localization on hepatobiliary phase T1-weighted MR images. Eur Radiol Exp 3:43. https:\/\/doi.org\/10.1186\/s41747-019-0120-7","journal-title":"Eur Radiol Exp"},{"key":"813_CR12","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1007\/s00330-018-5500-5","volume":"29","author":"D Truhn","year":"2019","unstructured":"Truhn D, Kuhl CK, Ciritsis A et al (2019) A new model for MR evaluation of liver function with gadoxetic acid, including both uptake and excretion. Eur Radiol 29:383\u2013391. https:\/\/doi.org\/10.1007\/s00330-018-5500-5","journal-title":"Eur Radiol"},{"key":"813_CR13","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.3390\/jcm10092003","volume":"10","author":"L Hitpass","year":"2021","unstructured":"Hitpass L, Amygdalos I, Sieben P et al (2021) MRI-based quantitation of hepatic steatosis does not predict hypertrophy rate after portal vein embolization in patients with colorectal liver metastasis and normal to moderately elevated fat fraction. J Clin Med 10:2003. https:\/\/doi.org\/10.3390\/jcm10092003","journal-title":"J Clin Med"},{"key":"813_CR14","doi-asserted-by":"publisher","first-page":"e0230553","DOI":"10.1371\/journal.pone.0230553","volume":"15","author":"J Th\u00fcring","year":"2020","unstructured":"Th\u00fcring J, Kuhl CK, Barabasch A et al (2020) Signal changes in T2-weighted MRI of liver metastases under bevacizumab\u2014a practical imaging biomarker? PLoS One 15:e0230553. https:\/\/doi.org\/10.1371\/journal.pone.0230553","journal-title":"PLoS One"},{"key":"813_CR15","doi-asserted-by":"publisher","first-page":"6865","DOI":"10.1007\/s00330-025-11670-6","volume":"35","author":"SD Westfechtel","year":"2025","unstructured":"Westfechtel SD, Ku\u00dfmann K, A\u00dfmann C et al (2025) AI in motion: the impact of data augmentation strategies on mitigating MRI motion artifacts. Eur Radiol 35:6865\u20136878. https:\/\/doi.org\/10.1007\/s00330-025-11670-6","journal-title":"Eur Radiol"},{"key":"813_CR16","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.241613","volume":"314","author":"T Akinci D\u2019Antonoli","year":"2025","unstructured":"Akinci D\u2019Antonoli T, Berger LK, Indrakanti AK et al (2025) TotalSegmentator MRI: robust sequence-independent segmentation of multiple anatomic structures in MRI. Radiology 314:e241613. https:\/\/doi.org\/10.1148\/radiol.241613","journal-title":"Radiology"},{"key":"813_CR17","doi-asserted-by":"publisher","first-page":"2487","DOI":"10.1007\/s00432-021-03803-3","volume":"148","author":"O \u00d6cal","year":"2022","unstructured":"\u00d6cal O, R\u00f6ssler D, Gasbarrini A et al (2022) Gadoxetic acid uptake as a molecular imaging biomarker for sorafenib resistance in patients with hepatocellular carcinoma: a post hoc analysis of the SORAMIC trial. J Cancer Res Clin Oncol 148:2487\u20132496. https:\/\/doi.org\/10.1007\/s00432-021-03803-3","journal-title":"J Cancer Res Clin Oncol"},{"key":"813_CR18","doi-asserted-by":"publisher","first-page":"3080","DOI":"10.1007\/s00330-016-4674-y","volume":"27","author":"D Geisel","year":"2017","unstructured":"Geisel D, Raabe P, L\u00fcdemann L et al (2017) Gd-EOB-DTPA-enhanced MRI for monitoring future liver remnant function after portal vein embolization and extended hemihepatectomy: a prospective trial. Eur Radiol 27:3080\u20133087. https:\/\/doi.org\/10.1007\/s00330-016-4674-y","journal-title":"Eur Radiol"},{"key":"813_CR19","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","volume":"86","author":"PE Shrout","year":"1979","unstructured":"Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420\u2013428","journal-title":"Psychol Bull"},{"key":"813_CR20","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s41747-025-00596-9","volume":"9","author":"L Zbinden","year":"2025","unstructured":"Zbinden L, Erb S, Catucci D et al (2025) Automated quantification of T1 and T2 relaxation times in liver mpMRI using deep learning: a sequence-adaptive approach. Eur Radiol Exp 9:58. https:\/\/doi.org\/10.1186\/s41747-025-00596-9","journal-title":"Eur Radiol Exp"},{"key":"813_CR21","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1002\/jmri.24443","volume":"40","author":"K Kamimura","year":"2014","unstructured":"Kamimura K, Fukukura Y, Yoneyama T et al (2014) Quantitative evaluation of liver function with T1 relaxation time index on Gd-EOB-DTPA-enhanced MRI: comparison with signal intensity-based indices. J Magn Reson Imaging 40:884\u2013889. https:\/\/doi.org\/10.1002\/jmri.24443","journal-title":"J Magn Reson Imaging"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00813-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-026-00813-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00813-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T08:02:16Z","timestamp":1791878536000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41747-026-00813-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,12]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["813"],"URL":"https:\/\/doi.org\/10.1186\/s41747-026-00813-z","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,12]]},"assertion":[{"value":"25 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 August 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 August 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study was performed in accordance with the Declaration of Helsinki and approved by the local ethics committee of RWTH Aachen University (reference number EK 24-148, approved 25 April 2024). Written informed consent was waived by the Institutional Review Board.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. This manuscript does not contain any identifiable person\u2019s data; all imaging data are fully de-identified.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"DT received honoraria for lectures from Bayer, GE, and Philips and holds shares in StratifAI GmbH, Germany, and in Synagen GmbH, Germany, neither of which has supported or influenced this study. The other authors (FBO, SW, FM, CS, JL, PW, CK, AB, and SN) declare that they have no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"155"}}