{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T10:04:55Z","timestamp":1790762695436,"version":"4.1.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100019180","name":"HORIZON EUROPE European Research Council","doi-asserted-by":"publisher","award":["101293057"],"award-info":[{"award-number":["101293057"]}],"id":[{"id":"10.13039\/100019180","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol Exp"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To determine the best combination of reconstruction parameters on a spectral photon-counting CT (SPCCT) system to improve detection of peritoneal metastases (PMs) on virtual monoenergetic images (VMIs) at 40\u2009keV.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      A spectral phantom was scanned using SPCCT and dual-energy CT (EID-DECT) at 8.5\u2009mGy (CTDI\n                      <jats:sub>vol<\/jats:sub>\n                      ). 40\u2009keV VMIs were reconstructed on EID-DECT using a level 4 Spectral algorithm and kernel B. For SPCCT, two reconstruction kernels (STD-B and HRB) and four iDose\n                      <jats:sup>4<\/jats:sup>\n                      levels (i5\/i7\/i9\/i11) were used. Noise power spectrum (NPS) and task-based transfer function (TTF) were analyzed. Detectability indices (\n                      <jats:italic>d<\/jats:italic>\n                      \u2019) for non-mucinous and mucinous peritoneal metastases (nmPMs and mPMs) were calculated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Noise magnitude (-22.4\u2009\u00b1\u20090.8%) and noise texture (\n                      <jats:italic>f<\/jats:italic>\n                      <jats:sub>av<\/jats:sub>\n                      ) values were lower (-21.3\u2009\u00b1\u20094.4%), but spatial resolution (\n                      <jats:italic>f<\/jats:italic>\n                      <jats:sub>50<\/jats:sub>\n                      ) was higher (5.8\u2009\u00b1\u20093.4%) with STD-B than with HRB at all iDose\n                      <jats:sup>4<\/jats:sup>\n                      levels. For both simulated PMs,\n                      <jats:italic>d<\/jats:italic>\n                      \u2019 values were higher with STD-B than with HRB (22.3\u2009\u00b1\u20090.3%). Compared to EID-DECT, noise magnitude and\n                      <jats:italic>d<\/jats:italic>\n                      \u2019 values were similar or better with STD-B at i7\/i9\/i11 and i9\/i11 for HRB. At all iDose\n                      <jats:sup>4<\/jats:sup>\n                      levels and with both kernels,\n                      <jats:italic>f<\/jats:italic>\n                      <jats:sub>av<\/jats:sub>\n                      or\n                      <jats:italic>f<\/jats:italic>\n                      <jats:sub>50<\/jats:sub>\n                      values were higher with SPCCT, except for\n                      <jats:italic>f<\/jats:italic>\n                      <jats:sub>50<\/jats:sub>\n                      at i11 with HRB.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Optimized reconstruction settings on SPCCT offer better image quality and lesion detectability on 40\u2009keV VMIs than EID-DECT. Combining the STD-B kernel with level i9 achieved the best compromise between noise texture, spatial resolution, and detectability for simulated PMs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Question<\/jats:italic>\n                      <\/jats:bold>\n                      Can the performance of a spectral photon-counting CT (SPCCT) improve detection of peritoneal metastases (PM on 40\u2009keV images compared with a conventional dual-energy CT (EID-DECT) system?\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Findings<\/jats:italic>\n                      <\/jats:bold>\n                      SPCCT with optimized reconstruction settings improved image noise, spatial resolution, and lesion detectability compared with EID-DECT at 40\u2009keV.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Relevance Statement<\/jats:italic>\n                      <\/jats:bold>\n                      SPCCT may enhance the preoperative assessment of colorectal cancer patients by better visualizing small or low-contrast peritoneal lesions. Validation in larger clinical cohorts is required to confirm these findings and define standardized reconstruction protocols.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s41747-026-00816-w","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T09:35:32Z","timestamp":1790760932000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optimization of spectral photon-counting CT reconstruction parameters for improved detection of peritoneal metastases compared with energy-integrating detector dual-energy CT: a phantom study"],"prefix":"10.1186","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1735-5129","authenticated-orcid":false,"given":"Jo\u00ebl","family":"Greffier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00e9mi","family":"Grange","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Djamel","family":"Dabli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ang\u00e8le","family":"Houmeau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Nicole","family":"Antonuccio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pascal","family":"Rousset","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salim","family":"Si-Mohamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"key":"816_CR1","doi-asserted-by":"publisher","first-page":"2283","DOI":"10.1016\/j.ejso.2020.07.039","volume":"46","author":"H Birgisson","year":"2020","unstructured":"Birgisson H, Enblad M, Artursson S, Ghanipour L, Cashin P, Graf W (2020) Patients with colorectal peritoneal metastases and high peritoneal cancer index may benefit from cytoreductive surgery and hyperthermic intraperitoneal chemotherapy. Eur J Surg Oncol 46:2283\u20132291","journal-title":"Eur J Surg Oncol"},{"key":"816_CR2","doi-asserted-by":"publisher","first-page":"1709","DOI":"10.1016\/S1470-2045(16)30500-9","volume":"17","author":"J Franko","year":"2016","unstructured":"Franko J, Shi Q, Meyers JP et al (2016) Prognosis of patients with peritoneal metastatic colorectal cancer given systemic therapy: an analysis of individual patient data from prospective randomised trials from the Analysis and Research in Cancers of the Digestive System (ARCAD) database. Lancet Oncol 17:1709\u20131719","journal-title":"Lancet Oncol"},{"key":"816_CR3","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1002\/bjs.10527","volume":"104","author":"A Dohan","year":"2017","unstructured":"Dohan A, Hoeffel C, Soyer P et al (2017) Evaluation of the peritoneal carcinomatosis index with CT and MRI. Br J Surg 104:1244\u20131249","journal-title":"Br J Surg"},{"key":"816_CR4","doi-asserted-by":"publisher","unstructured":"Grange R, Si-Mohamed S, Benzerdjeb N et al (2025) Spectral CT in patients with colorectal cancer: quantitative contrast lesional assessment of mucinous and non-mucinous peritoneal metastases using virtual monoenergetic imaging. Abdom Radiol (NY). https:\/\/doi.org\/10.1007\/s00261-025-05355-3","DOI":"10.1007\/s00261-025-05355-3"},{"key":"816_CR5","doi-asserted-by":"publisher","first-page":"3101","DOI":"10.1007\/s00330-019-06524-x","volume":"30","author":"I van \u2018t Sant","year":"2020","unstructured":"van \u2018t Sant I, Engbersen MP, Bhairosing PA et al (2020) Diagnostic performance of imaging for the detection of peritoneal metastases: a meta-analysis. Eur Radiol 30:3101\u20133112","journal-title":"Eur Radiol"},{"key":"816_CR6","doi-asserted-by":"publisher","first-page":"1582","DOI":"10.1245\/s10434-010-1492-3","volume":"18","author":"TC Chua","year":"2011","unstructured":"Chua TC, Al-Zahrani A, Saxena A et al (2011) Determining the association between preoperative computed tomography findings and postoperative outcomes after cytoreductive surgery and perioperative intraperitoneal chemotherapy for pseudomyxoma peritonei. Ann Surg Oncol 18:1582\u20131589","journal-title":"Ann Surg Oncol"},{"key":"816_CR7","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1245\/s10434-008-0234-2","volume":"16","author":"JL Koh","year":"2009","unstructured":"Koh JL, Yan TD, Glenn D, Morris DL (2009) Evaluation of preoperative computed tomography in estimating peritoneal cancer index in colorectal peritoneal carcinomatosis. Ann Surg Oncol 16:327\u2013333","journal-title":"Ann Surg Oncol"},{"key":"816_CR8","doi-asserted-by":"publisher","DOI":"10.1002\/mp.70093","volume":"52","author":"J Greffier","year":"2025","unstructured":"Greffier J, Dabli D, Pastor M et al (2025) Impact of a prototype, dedicated AI-based spectral image reconstruction algorithm on the quality of low-keV virtual monoenergetic images and iodine maps: a phantom study. Med Phys 52:e70093","journal-title":"Med Phys"},{"key":"816_CR9","doi-asserted-by":"publisher","unstructured":"Greffier J, Salvat C, Pastor M et al (2025) Comparison of spectral performance of three dual-energy CT scanners equipped with a deep-learning image reconstruction algorithm and one photon counting CT scanner: a phantom study. Diagn Interv Imaging. https:\/\/doi.org\/10.1016\/j.diii.2025.11.007","DOI":"10.1016\/j.diii.2025.11.007"},{"key":"816_CR10","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.diii.2022.11.003","volume":"104","author":"J Greffier","year":"2023","unstructured":"Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S (2023) Spectral CT imaging: technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging 104:167\u2013177","journal-title":"Diagn Interv Imaging"},{"key":"816_CR11","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.diii.2024.09.002","volume":"106","author":"J Greffier","year":"2025","unstructured":"Greffier J, Viry A, Robert A, Khorsi M, Si-Mohamed S (2025) Photon-counting CT systems: a technical review of current clinical possibilities. Diagn Interv Imaging 106:53\u201359","journal-title":"Diagn Interv Imaging"},{"key":"816_CR12","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.diii.2024.01.002","volume":"105","author":"R Grange","year":"2024","unstructured":"Grange R, Si-Mohamed S, Kepenekian V, Boccalini S, Glehen O, Rousset P (2024) Spectral photon-counting CT: Hype or hope for colorectal peritoneal metastases imaging? Diagn Interv Imaging 105:118\u2013120","journal-title":"Diagn Interv Imaging"},{"key":"816_CR13","doi-asserted-by":"publisher","first-page":"5476","DOI":"10.1007\/s00330-023-09529-9","volume":"33","author":"J Greffier","year":"2023","unstructured":"Greffier J, Si-Mohamed SA, Lacombe H et al (2023) Virtual monochromatic images for coronary artery imaging with a spectral photon-counting CT in comparison to dual-layer CT systems: a phantom and a preliminary human study. Eur Radiol 33:5476\u20135488","journal-title":"Eur Radiol"},{"key":"816_CR14","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.diii.2024.09.011","volume":"106","author":"H Lacombe","year":"2025","unstructured":"Lacombe H, Labour J, de Oliveira F et al (2025) Ultra-high resolution spectral photon-counting CT outperforms dual layer CT for lung imaging: results of a phantom study. Diagn Interv Imaging 106:60\u201367","journal-title":"Diagn Interv Imaging"},{"key":"816_CR15","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1016\/j.diii.2022.05.007","volume":"103","author":"J Greffier","year":"2022","unstructured":"Greffier J, Barbotteau Y, Gardavaud F (2022) iQMetrix-CT: new software for task-based image quality assessment of phantom CT images. Diagn Interv Imaging 103:555\u2013562","journal-title":"Diagn Interv Imaging"},{"key":"816_CR16","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/j.diii.2024.02.009","volume":"105","author":"J Greffier","year":"2024","unstructured":"Greffier J, Faby S, Pastor M et al (2024) Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: a phantom study. Diagn Interv Imaging 105:311\u2013318","journal-title":"Diagn Interv Imaging"},{"key":"816_CR17","doi-asserted-by":"publisher","first-page":"2233","DOI":"10.1002\/mp.15558","volume":"49","author":"J Greffier","year":"2022","unstructured":"Greffier J, Viry A, Barbotteau Y et al (2022) Phantom task-based image quality assessment of three generations of rapid kV-switching dual-energy CT systems on virtual monoenergetic images. Med Phys 49:2233\u20132244","journal-title":"Med Phys"},{"key":"816_CR18","doi-asserted-by":"publisher","first-page":"e735","DOI":"10.1002\/mp.13763","volume":"46","author":"E Samei","year":"2019","unstructured":"Samei E, Bakalyar D, Boedeker KL et al (2019) Performance evaluation of computed tomography systems: summary of AAPM task group 233. Med Phys 46:e735\u2013e756","journal-title":"Med Phys"},{"key":"816_CR19","doi-asserted-by":"publisher","first-page":"4115","DOI":"10.1118\/1.4725171","volume":"39","author":"S Richard","year":"2012","unstructured":"Richard S, Husarik DB, Yadava G, Murphy SN, Samei E (2012) Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms. Med Phys 39:4115\u20134122","journal-title":"Med Phys"},{"key":"816_CR20","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1364\/OE.11.000460","volume":"11","author":"M Eckstein","year":"2003","unstructured":"Eckstein M, Bartroff J, Abbey C, Whiting J, Bochud F (2003) Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks. Opt Express 11:460\u2013475","journal-title":"Opt Express"},{"key":"816_CR21","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.diii.2024.11.003","volume":"106","author":"E O\u2019Shaughnessy","year":"2025","unstructured":"O\u2019Shaughnessy E, Detrinidad E, Soyer P, Lecler A (2025) An introductory guide to statistics for the radiologist. Diagn Interv Imaging 106:49\u201352","journal-title":"Diagn Interv Imaging"},{"key":"816_CR22","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1007\/s00330-021-08103-5","volume":"32","author":"SA Si-Mohamed","year":"2022","unstructured":"Si-Mohamed SA, Greffier J, Miailhes J et al (2022) Comparison of image quality between spectral photon-counting CT and dual-layer CT for the evaluation of lung nodules: a phantom study. Eur Radiol 32:524\u2013532","journal-title":"Eur Radiol"},{"key":"816_CR23","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/S1470-2045(20)30599-4","volume":"22","author":"F Quenet","year":"2021","unstructured":"Quenet F, Elias D, Roca L et al (2021) Cytoreductive surgery plus hyperthermic intraperitoneal chemotherapy versus cytoreductive surgery alone for colorectal peritoneal metastases (PRODIGE 7): a multicentre, randomised, open-label, phase 3 trial. Lancet Oncol 22:256\u2013266","journal-title":"Lancet Oncol"},{"key":"816_CR24","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1038\/s41571-022-00675-5","volume":"19","author":"V Kepenekian","year":"2022","unstructured":"Kepenekian V, Bhatt A, Peron J et al (2022) Advances in the management of peritoneal malignancies. Nat Rev Clin Oncol 19:698\u2013718","journal-title":"Nat Rev Clin Oncol"}],"container-title":["European Radiology Experimental"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00816-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s41747-026-00816-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s41747-026-00816-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T09:35:33Z","timestamp":1790760933000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s41747-026-00816-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["816"],"URL":"https:\/\/doi.org\/10.1186\/s41747-026-00816-w","relation":{},"ISSN":["2509-9280"],"issn-type":[{"value":"2509-9280","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]},"assertion":[{"value":"29 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 August 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Institutional Review Board approval was obtained. The local ethics committee board approved the study (Hospices Civils de Lyon, approval number: 2019-A02945\u201352, SPEQUA study).","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from the patient participating in this study.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Maria Nicole Antonuccio is an employee of Philips Healthcare. Salim Si-Mohamed is a member of the\n                      European Radiology Experimental\n                      Editorial Board, and as such, they have not participated in the review or selection processes for this article. The remaining authors have no relevant conflicts of interest or industry support for the project to declare.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"144"}}