{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,21]],"date-time":"2026-06-21T04:48:32Z","timestamp":1782017312437,"version":"3.54.5"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,12,4]],"date-time":"2020-12-04T00:00:00Z","timestamp":1607040000000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CVIR Endovasc"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>This case report demonstrates the value of IMPEDE-FX plugs in an embolization procedure of a false lumen of an infrarenal post-dissection aneurysm.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Case presentation<\/jats:title>\n<jats:p>A 69-year-old patient was treated with mitral valve replacement, complicated by a Stanford type-A dissection. After 9\u2009years he presented with an enlarging infrarenal post-dissection aneurysm. The false lumen was embolized using multiple IMPEDE-FX plugs as part of the treatment in addition to embolization of the inferior mesenteric artery and overstenting of the re-entry in the right iliac artery. At 15\u2009months the CTA showed a fully thrombosed false lumen and remodeling of the true lumen.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>The false lumen of an infrarenal post-dissection aneurysm can successfully be embolized using IMPEDE-FX embolization plugs as part of the treatment strategy. Prospective trials on patients with non-thrombosed false lumina are indicated.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s42155-020-00183-6","type":"journal-article","created":{"date-parts":[[2020,12,4]],"date-time":"2020-12-04T05:03:34Z","timestamp":1607058214000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Embolization of the false lumen using IMPEDE-FX embolization plugs as part of treatment of an infrarenal post-dissection aneurysm: a case report"],"prefix":"10.1186","volume":"3","author":[{"given":"Anne-Jet S.","family":"Jansen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul M.","family":"van Schaik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasper M.","family":"Martens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5021-1768","authenticated-orcid":false,"given":"Michel M. P. J.","family":"Reijnen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,12,4]]},"reference":[{"key":"183_CR1","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1177\/0284185113481696","volume":"54","author":"J Enriquez","year":"2013","unstructured":"Enriquez J, Javadi S, Murthy R, EnsorJr J, Mahvash A, Abdelsalam ME et al (2013) Gastroduodenal artery recanalization after transcatheter fibered coil embolization for prevention of hepaticoenteric flow: incidence and predisposing technical factors in 142 patients. Acta Radiol 54:790\u2013794","journal-title":"Acta Radiol"},{"key":"183_CR2","unstructured":"FDA Report IMPEDE Embolization Plug, 5mm, IMPEDE Embolization Plug, 7mm, IMPEDE Embolization Plug, 10mm. FDA Databases. https:\/\/fda.report\/PMN\/K181051. Published June 22, 2018. Accessed 31 Jan 2020"},{"key":"183_CR3","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1583\/JEVT-12-3844R.1","volume":"19","author":"SC Hofferberth","year":"2012","unstructured":"Hofferberth SC, Nixon IK, Mossop PJ (2012) Aortic false lumen thrombosis induction by embolotherapy (AFTER) following endovascular repair of aortic dissection. J Endovasc Ther 19:538\u2013545","journal-title":"J Endovasc Ther"},{"key":"183_CR4","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1016\/j.jvs.2014.08.094","volume":"60","author":"J Idrees","year":"2014","unstructured":"Idrees J, Roselli EE, Shafii S, Reside J, Lytle BW (2014) Outcomes after false lumen embolization with covered stent devices in chronic dissection. J Vasc Surg 60:1507\u20131513","journal-title":"J Vasc Surg"},{"key":"183_CR5","unstructured":"IMPEDE-FX Embolization Plug Instructions for Use. Shape memory medical. https:\/\/www.shapemem.com\/impedefx-usonly. Updated Nov 2018. Accessed 31 Jan 2020"},{"key":"183_CR6","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1583\/13-4318.1","volume":"20","author":"T K\u00f6lbel","year":"2013","unstructured":"K\u00f6lbel T, Lohrenz C, Kieback A, Diener H, Debus ES, Larena-Avellaneda A (2013) Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther 20:484\u2013489","journal-title":"J Endovasc Ther"},{"key":"183_CR7","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.jmbbm.2016.06.019","volume":"63","author":"TL Landsman","year":"2016","unstructured":"Landsman TL, Bush RL, Glowczwski A, Horn J, Jessen SL, Ungchusri E et al (2016) Design and verification of a shape memory polymer peripheral occlusion device. J Mech Behav Biomed Mater 63:195\u2013206","journal-title":"J Mech Behav Biomed Mater"},{"key":"183_CR9","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1002\/jbm.a.34782","volume":"102","author":"JN Rodriguez","year":"2014","unstructured":"Rodriguez JN, Clubb FJ, Wilson TS, Miller MW, Fossum TW, Hartman J et al (2014a) In vivo response to an implanted shape memory polyurethane foam in a porcine aneurysm model. J Biomed Mater Res 102:1231\u20131242","journal-title":"J Biomed Mater Res"},{"key":"183_CR10","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/j.jmbbm.2014.07.037","volume":"40","author":"JN Rodriguez","year":"2014","unstructured":"Rodriguez JN, Miller MW, Boyle A, Horn J, Yang CK, Wilson TS et al (2014b) Reticulation of low density shape memory polymer foam with an in vivo demonstration of vascular occlusion. J Mech Behav Biomed Mater 40:102\u2013114","journal-title":"J Mech Behav Biomed Mater"},{"key":"183_CR11","doi-asserted-by":"publisher","first-page":"784","DOI":"10.23736\/S0021-9509.18.10638-0","volume":"59","author":"F Rohlffs","year":"2018","unstructured":"Rohlffs F, Spanos K, Tsilimparis N, Debus ES, K\u00f6lbel T (2018) Techniques and outcomes of false lumen embolization in chronic type B aortic dissection. J Cardiovasc Surg 59:784\u2013788","journal-title":"J Cardiovasc Surg"},{"key":"183_CR12","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1002\/polb.23056","volume":"50","author":"P Singhal","year":"2012","unstructured":"Singhal P, Rodriguez JN, Small W, Eagleston S, van de Water J, Maitland DJ et al (2012) Ultra low density and highly crosslinked biocompatible shape memory polyurethane foams. J Polym Sci Part B Polym Phys 50:724\u2013737","journal-title":"J Polym Sci Part B Polym Phys"},{"key":"183_CR13","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1016\/j.jacc.2007.03.064","volume":"50","author":"JM Song","year":"2007","unstructured":"Song JM, Kim SD, Kim JH, Kim MJ, Kang DH, Seo JB et al (2007) Long-term predictors of descending aorta aneurysmal change in patients with aortic dissection. J Am Coll Cardiol 50:799\u2013804","journal-title":"J Am Coll Cardiol"},{"key":"183_CR14","doi-asserted-by":"publisher","first-page":"1798","DOI":"10.1016\/j.jvir.2013.04.030","volume":"24","author":"T Yasumoto","year":"2013","unstructured":"Yasumoto T, Osuga K, Yamamoto H, Ono Y, Masada M, Mikami K et al (2013) Long-term outcomes of coil packing for visceral aneurysms: correlation between packing density and incidence of coil compaction or recanalization. J Vasc Interv Radiol 24:1798\u20131807","journal-title":"J Vasc Interv Radiol"}],"container-title":["CVIR Endovascular"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-020-00183-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s42155-020-00183-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-020-00183-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,4]],"date-time":"2020-12-04T05:04:05Z","timestamp":1607058245000},"score":1,"resource":{"primary":{"URL":"https:\/\/CVIRendovasc.springeropen.com\/articles\/10.1186\/s42155-020-00183-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["183"],"URL":"https:\/\/doi.org\/10.1186\/s42155-020-00183-6","relation":{},"ISSN":["2520-8934"],"issn-type":[{"value":"2520-8934","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12]]},"assertion":[{"value":"16 September 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 November 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 December 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"No conflicts of interest occurred performing this study and writing this article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"91"}}