{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T02:00:35Z","timestamp":1794276035244,"version":"4.9.0"},"reference-count":3,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CVIR Endovasc"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>This is a rare case of removing an intra-arterial foreign body represented by MynxGrip polyethylene glycol (PEG) sealant as a rare complication of using the MynxGrip\u2122 Vascular Closure Device (AccessClosure, Inc., Mountain View, CA) using a pRESET stent retriever (Phenox, Bochum, Germany) which is utilized mainly for treatment of endovascular stroke.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 60-year-old female patient suffering from intermittent claudication in the right lower limb (stage IIb according to Fontaine) due to a peripheral arterial occlusive disease was presented for an elective revascularization using balloon angioplasty of a short chronic occlusion of the right superficial femoral artery. After a successful revascularization of the right superficial femoral artery using a retrograde femoral access from the left common femoral artery, the patient suffered from an acute limb ischemia in the left foot with distal popliteal embolization with involvement of BTK (below the knee) trifurcation. This is believed to be due to an intra-arterial foreign body embolism of MynxGrip polyethylene glycol sealant as a rare complication of using the MynxGrip\u2122 Vascular Closure Device.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Stent retrievers have been used previously in removing dislocated coils especially in the cerebral vessels. This case report however proves a high efficacy and safety of using stent retrievers in removing different and rather unusual intra-arterial foreign bodies such as MynxGrip polyethylene glycol sealant.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s42155-020-00197-0","type":"journal-article","created":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T07:03:14Z","timestamp":1614582194000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Endovascular foreign body removal of a MynxGrip polyethylene glycol (PEG) sealant embolus using a cerebral stent retriever"],"prefix":"10.1186","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1824-1588","authenticated-orcid":false,"given":"Mohammed","family":"Shamseldin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hendrik","family":"Bergert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Axel","family":"Neumeister","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralf","family":"Puls","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,3,1]]},"reference":[{"key":"197_CR1","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.3174\/ajnr.A2153","volume":"31","author":"Fields","year":"2010","unstructured":"Fields et al (2010) Femoral artery complications associated with the Mynx closure device. AJNR Am J Neuroradiol 31:1737\u20131740","journal-title":"AJNR Am J Neuroradiol"},{"issue":"9","key":"197_CR2","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1024\/0301-1526\/a000260","volume":"76","author":"A Gupta","year":"2012","unstructured":"Gupta A, Sadiq I, Borer S (2012) Distal embolization from Mynx device. Conn Med 76(9):545\u2013548 PMID: 23155673. Vasa (2013), 42, pp. 144\u2013148. https:\/\/doi.org\/10.1024\/0301-1526\/a000260","journal-title":"Conn Med"},{"key":"197_CR3","unstructured":"Thai HM, Weinstock BS (2012) The MynxGrip\u2122 Vascular Closure Device. Initial experience with active extravascular arteriotomy closure. Endovasc Today pp. 28\u201333."}],"container-title":["CVIR Endovascular"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-020-00197-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s42155-020-00197-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-020-00197-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T07:05:38Z","timestamp":1614582338000},"score":1,"resource":{"primary":{"URL":"https:\/\/CVIRendovasc.springeropen.com\/articles\/10.1186\/s42155-020-00197-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,1]]},"references-count":3,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["197"],"URL":"https:\/\/doi.org\/10.1186\/s42155-020-00197-0","relation":{},"ISSN":["2520-8934"],"issn-type":[{"value":"2520-8934","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,1]]},"assertion":[{"value":"5 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Informed consent was obtained from all individual participants included in the study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"\u201cConsent for publication was obtained for every individual person\u2019s data included in the study.\u201d","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"23"}}