{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T13:40:03Z","timestamp":1784900403812,"version":"3.55.0"},"reference-count":8,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CVIR Endovasc"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Ascending aortic pseudoaneurysms (AAPs) constitute a rare, albeit potentially dangerous, condition that occurs in up to 13% of patients after cardiac or aortic surgeries. For patients with a history of cardiac surgery, repeat thoracotomy poses additive risks. The high morbidity and mortality rates associated with the surgical management of AAPs have led to the development of transcatheter approaches.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case report<\/jats:title>\n                <jats:p>We report a case of AAP percutaneous closure at the site of aortic cannulation with an ASO device in a post-CABG 65-year-old man, who refused surgery.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The use of the Amplatzer Atrial Septal Defect Occluder (ASO) device represents an acceptable alternative to surgery in treatment of Ascending aortic pseudoaneurysms.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s42155-021-00280-0","type":"journal-article","created":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T07:03:14Z","timestamp":1643698994000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Cardiac solution for a vascular scenario!"],"prefix":"10.1186","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5964-1724","authenticated-orcid":false,"given":"Jamal","family":"Moosavi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7903-1958","authenticated-orcid":false,"given":"Somaye","family":"Ahmadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ata","family":"Firouzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parham","family":"Sadeghipour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bahram","family":"Mohebbi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omid","family":"Shafe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Azin","family":"Alizadeasl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanaz","family":"Asadian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehran","family":"Hoseini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,2,1]]},"reference":[{"issue":"4","key":"280_CR1","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1002\/ccd.20422","volume":"65","author":"F Bashir","year":"2005","unstructured":"Bashir F, Quaife R, Carroll JD (2005) Percutaneous closure of ascending aortic pseudo-aneurysm using Amplatzer septal occluder device: the first clinical case report and literature review. Catheter Cardiovasc Interv 65(4):547\u2013551. https:\/\/doi.org\/10.1002\/ccd.20422","journal-title":"Catheter Cardiovasc Interv"},{"key":"280_CR2","doi-asserted-by":"publisher","first-page":"1010","DOI":"10.1016\/S0003-4975(00)02265-7","volume":"71","author":"N D\u2019Attellis","year":"2001","unstructured":"D\u2019Attellis N, Diemont FF, Julia PL et al (2001) Management of pseudo-aneurysm of the ascending aorta performed under circulatory arrest by port-access. Ann Thorac Surg 71:1010\u20131011","journal-title":"Ann Thorac Surg"},{"issue":"3","key":"280_CR3","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1111\/j.1540-8191.2006.00220.x","volume":"21","author":"AK Dhadwal","year":"2006","unstructured":"Dhadwal AK, Abrol S, Zisbrod Z, Cunningham JN (2006) Pseudo-aneurysms of the ascending aorta following coronary artery bypass surgery. Comparative Study J Card Surg 21(3):221\u2013224. https:\/\/doi.org\/10.1111\/j.1540-8191.2006.00220.x","journal-title":"Comparative Study J Card Surg"},{"issue":"1","key":"280_CR4","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1002\/ccd.20794","volume":"69","author":"RS Kanani","year":"2007","unstructured":"Kanani RS, Neilan TG, Palacios IF, Garasic JM (2007) Novel use of the Amplatzer septal occluder device in the percutaneous closure of ascending aortic pseudo-aneurysms: a case series. Catheterization Cardiovasc Interv 69(1):146\u2013153. https:\/\/doi.org\/10.1002\/ccd.20794","journal-title":"Catheterization Cardiovasc Interv"},{"issue":"4","key":"280_CR5","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.athoracsur.2008.07.053","volume":"87","author":"BRJ Kannan","year":"2009","unstructured":"Kannan BRJ, Jain AK, Qureshi SA, Rothman MT, Rosenthal E, Mathur A (2009) Successful exclusion of large post-surgical pseudo-aneurysms of the ascending aorta by a percutaneous approach. Ann Thorac Surg 87(4):1281\u20131284. https:\/\/doi.org\/10.1016\/j.athoracsur.2008.07.053","journal-title":"Ann Thorac Surg"},{"issue":"2","key":"280_CR6","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1002\/ccd.23094","volume":"79","author":"S Noble","year":"2012","unstructured":"Noble S, Ibrahim R (2012) Embolization of an Amplatzer MVSD occluder device used for percutaneous closure of an ascending aortic pseudo-aneurysm: case report and literature review. Catheter Cardiovasc Interv 79(2):334\u2013338. https:\/\/doi.org\/10.1002\/ccd.23094","journal-title":"Catheter Cardiovasc Interv"},{"issue":"4","key":"280_CR7","first-page":"576","volume":"14","author":"HC Quevedo","year":"2014","unstructured":"Quevedo HC, Trinidad RS, Castellanos J et al (2014) Systematic review of interventions to repair ascending aortic Pseudo-aneurysms. Ochsner J 14(4):576\u2013585","journal-title":"Ochsner J"},{"issue":"12","key":"280_CR8","first-page":"818","volume":"59","author":"AJ Razzouk","year":"1993","unstructured":"Razzouk AJ, Gundry S, Wang N, Heyner R, Sciolaro C, van Arsdell G, Bansal R, Vyhmeister E, Bailey L (1993) Pseudo-aneurysms of the aorta after cardiac surgery or chest trauma. Am Surg 59(12):818\u2013823","journal-title":"Am Surg"}],"container-title":["CVIR Endovascular"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-021-00280-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42155-021-00280-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-021-00280-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T07:11:09Z","timestamp":1643699469000},"score":1,"resource":{"primary":{"URL":"https:\/\/CVIRendovasc.springeropen.com\/articles\/10.1186\/s42155-021-00280-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,1]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["280"],"URL":"https:\/\/doi.org\/10.1186\/s42155-021-00280-0","relation":{},"ISSN":["2520-8934"],"issn-type":[{"value":"2520-8934","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,1]]},"assertion":[{"value":"29 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9"}}