{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T01:49:22Z","timestamp":1774489762410,"version":"3.50.1"},"reference-count":9,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,29]],"date-time":"2023-11-29T00:00:00Z","timestamp":1701216000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,29]],"date-time":"2023-11-29T00:00:00Z","timestamp":1701216000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CVIR Endovasc"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Although the candy-plug technique has been reported to be useful for the treatment of post-dissection aortic aneurysm, the stent graft needs be to customized to accommodate the size of vascular occluders.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>We present a case of a persistent false lumen successfully treated with endovascular stent-graft and atrial septal defect occluder in a patient with Stanford Type B dissection. A covered stent graft was implanted into the false cavity through a distal rupture, and an atrial septal defect occluder was inserted into the covered stent to seal of the false cavity. Decreased aneurysmal diameter and false lumen thrombosis were noted by CT scan at 6-month follow-up.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Our case showed that combined use of a stent graft and atrial septal defect occluder is safe, technically feasible and effective in sealing of the false lumen in post-dissection aortic aneurysm patients with previously failed false lumen thrombosis.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s42155-023-00405-7","type":"journal-article","created":{"date-parts":[[2023,11,29]],"date-time":"2023-11-29T09:03:15Z","timestamp":1701248595000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Atrial septal defect occluder combined with stent graft for the management of post-dissection aortic aneurysm previously treated with unsuccessful coils: a case report"],"prefix":"10.1186","volume":"6","author":[{"given":"Qiqi","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haijun","family":"Wei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunshui","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,11,29]]},"reference":[{"key":"405_CR1","doi-asserted-by":"publisher","first-page":"2126","DOI":"10.1056\/NEJMoa1715955","volume":"380","author":"FA Lederle","year":"2019","unstructured":"Lederle FA, Kyriakides TC, Stroupe KT, et al. Open versus endovascular repair of abdominal aortic aneurysm. N Engl J Med. 2019;380:2126\u201335.","journal-title":"N Engl J Med"},{"key":"405_CR2","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.ejvs.2023.03.020","volume":"66","author":"A Eleshra","year":"2023","unstructured":"Eleshra A, Haulon S, Bertoglio L, et al. Custom-made candy-plug for distal false lumen occlusion in aortic dissection: international experience. Eur J Vasc Endovasc Surg. 2023;66:50\u20136.","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"2","key":"405_CR3","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.athoracsur.2020.04.093","volume":"111","author":"KG Miletic","year":"2021","unstructured":"Miletic KG, Kindzelski BA, Hodges KE, et al. Impact of endovascular false lumen embolization on thoracic aortic remodeling in chronic dissection. Ann Thorac Surg. 2021;111(2):495\u2013501.","journal-title":"Ann Thorac Surg"},{"key":"405_CR4","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.avsg.2019.06.041","volume":"63","author":"M Wang","year":"2020","unstructured":"Wang M, He Q, Yao C, et al. Treatment of high surgical risk thoracoabdominal aortic aneurysms with stent graft and multilayer bare stents joint technique: mid-long-term clinical results. Ann Vasc Surg. 2020;63:108\u201316.","journal-title":"Ann Vasc Surg"},{"key":"405_CR5","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.avsg.2016.06.030","volume":"40","author":"K Ke","year":"2017","unstructured":"Ke K, Zheng H, Yang W. Is multilayer bare stent safe or effective for the treatment of aortic aneurysms? A meta-analysis with early and mid-term outcomes. Ann Vasc Surg. 2017;40:112\u20139.","journal-title":"Ann Vasc Surg"},{"key":"405_CR6","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1177\/1526602817709252","volume":"24","author":"F Rohlffs","year":"2017","unstructured":"Rohlffs F, Tsilimparis N, Fiorucci B, et al. The candy-plug technique: technical aspects and early results of a new endovascular method for false lumen occlusion in chronic aortic dissection. J Endovasc Ther. 2017;24:549\u201355.","journal-title":"J Endovasc Ther"},{"key":"405_CR7","doi-asserted-by":"publisher","first-page":"e70","DOI":"10.1016\/j.ijcard.2014.07.160","volume":"176","author":"J Hu","year":"2014","unstructured":"Hu J, Yang J. Atrial septal defect occluder for the distal re-entry tear in type B aortic dissection. Int J Cardiol. 2014;176:e70\u20132.","journal-title":"Int J Cardiol"},{"key":"405_CR8","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2021-242304","volume":"14","author":"IS Petrov","year":"2021","unstructured":"Petrov IS, Stankov ZI, Boychev DB. Use of ASD closure device for the sealing of false lumen entry in the ascending aorta after dissection Type A surgical repair. BMJ Case Rep. 2021;14: e242304.","journal-title":"BMJ Case Rep"},{"key":"405_CR9","doi-asserted-by":"publisher","first-page":"1864","DOI":"10.1016\/j.jvs.2021.12.060","volume":"75","author":"H Lu","year":"2022","unstructured":"Lu H, Lin Z, Chen Y, et al. Aortic remodeling after false lumen occlusion using an atrial septal occluder in chronic DeBakey IIIb aortic dissection. J Vasc Surg. 2022;75:1864-1871.e3.","journal-title":"J Vasc Surg"}],"container-title":["CVIR Endovascular"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-023-00405-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42155-023-00405-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-023-00405-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,29]],"date-time":"2023-11-29T09:10:11Z","timestamp":1701249011000},"score":1,"resource":{"primary":{"URL":"https:\/\/CVIRendovasc.springeropen.com\/articles\/10.1186\/s42155-023-00405-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,29]]},"references-count":9,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["405"],"URL":"https:\/\/doi.org\/10.1186\/s42155-023-00405-7","relation":{},"ISSN":["2520-8934"],"issn-type":[{"value":"2520-8934","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,29]]},"assertion":[{"value":"19 September 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"58"}}