{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T12:54:16Z","timestamp":1784120056038,"version":"3.55.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,2,8]],"date-time":"2025-02-08T00:00:00Z","timestamp":1738972800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,2,8]],"date-time":"2025-02-08T00:00:00Z","timestamp":1738972800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100006479","name":"Cordis","doi-asserted-by":"publisher","award":["Cordis"],"award-info":[{"award-number":["Cordis"]}],"id":[{"id":"10.13039\/100006479","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100011949","name":"Abbott Vascular","doi-asserted-by":"publisher","award":["Abbott Vascular"],"award-info":[{"award-number":["Abbott Vascular"]}],"id":[{"id":"10.13039\/100011949","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CVIR Endovasc"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Percutaneous endovascular repair (PEVAR) of infra-renal abdominal aortic aneurysms (AAA) is increasingly being performed due to the development of low profile endografts and the use of percutaneous closure devices. The feasibility and safety of the use of the INCRAFT AAA Stentgraft System and the ProGlide vascular closure system was assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>The PUCCINI trial prospectively enrolled patients undergoing elective repair of infrarenal AAA at 3 centres in the Netherlands and 3 centres in Belgium. Patients underwent PEVAR with endograft implantation followed by closure using the ProGlide closure device. Procedural success rates, complications and 30-day follow-up outcomes were collected.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>A total of 93 patients, 87% male, were enrolled. The mean aneurysmal diameter was 53.9\u2009\u00b1\u200910.2 mm. Successful ProGlide placement was achieved in 97.2% in the right and 89.8% in the left groin. Successful closure was achieved in 92.4% of right and 90% of left groins. One patient required surgical access and two surgical closure. Average blood loss was 155.6\u2009\u00b1\u2009175.5ml. Blood transfusion was not required. Average length of hospital stay was 2.1\u2009\u00b1\u20091.3 days. Post-implantation endoleaks were present in 37 (40.2%) patients (type 1: 12, type 2: 25). At 30-days there was no aneurysmal growth and no deaths. Follow-up imaging showed endoleaks in 39 (41.9%) patients. (type 1:8, type 2:29, type 3:2).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The results from the PUCCINI trial demonstrate that the use of a low profile endoprosthesis for treatment of infrarenal AAA with percutaneous closure has a high rate of technical success and low rates of periprocedural complication.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s42155-025-00523-4","type":"journal-article","created":{"date-parts":[[2025,2,8]],"date-time":"2025-02-08T08:46:56Z","timestamp":1739004416000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Percutaneous Closure Device Controlled INCRAFT Stentgraft Implantation Registry (PUCCINI)"],"prefix":"10.1186","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-1623-161X","authenticated-orcid":false,"given":"T.","family":"Engelen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Hoogervorst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"DeLoose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. C.","family":"van Dijk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. S.","family":"van Eps","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. B.","family":"van Tongeren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. T.","family":"Veger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Maene","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.","family":"Stomp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O. R.","family":"Wikkeling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. J. C.","family":"Klink","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.","family":"van den Eynde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. J.","family":"Wever","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"van Overhagen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,8]]},"reference":[{"issue":"6","key":"523_CR1","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1007\/BF02015271","volume":"5","author":"JC Parodi","year":"1991","unstructured":"Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg. 1991;5(6):491\u20139.","journal-title":"Ann Vasc Surg"},{"issue":"20","key":"523_CR2","doi-asserted-by":"publisher","first-page":"1863","DOI":"10.1056\/NEJMoa0909305","volume":"362","author":"RM Greenhalgh","year":"2010","unstructured":"United Kingdom ETI, Greenhalgh RM, Brown LC, Powell JT, Thompson SG, Epstein D, Sculpher MJ. Endovascular versus open repair of abdominal aortic aneurysm. N Engl J Med. 2010;362(20):1863\u201371.","journal-title":"N Engl J Med"},{"issue":"6","key":"523_CR3","first-page":"791","volume":"51","author":"L Lonn","year":"2010","unstructured":"Lonn L, Larzon T, Van Den Berg JC. From puncture to closure of the common femoral artery in endovascular aortic repair. J Cardiovasc Surg (Torino). 2010;51(6):791\u20138.","journal-title":"J Cardiovasc Surg (Torino)"},{"issue":"4","key":"523_CR4","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1055\/s-0040-1714728","volume":"37","author":"MM Watts","year":"2020","unstructured":"Watts MM. Percutaneous endovascular aneurysm repair: current status and future trends. Semin Intervent Radiol. 2020;37(4):339\u201345.","journal-title":"Semin Intervent Radiol"},{"issue":"5","key":"523_CR5","first-page":"650","volume":"58","author":"G Pratesi","year":"2017","unstructured":"Pratesi G, Pratesi C, Chiesa R, Coppi G, Scheinert D, Brunkwall JS, et al. The INNOVATION Trial: four-year safety and effectiveness of the INCRAFT(R) AAA Stent-Graft System for endovascular repair. J Cardiovasc Surg (Torino). 2017;58(5):650\u20137.","journal-title":"J Cardiovasc Surg (Torino)"},{"issue":"3","key":"523_CR6","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1016\/j.jvs.2020.06.128","volume":"73","author":"NL Liang","year":"2021","unstructured":"Liang NL, Ohki T, Ouriel K, Teigen C, Fry D, Henretta J, et al. Five-year results of the INSPIRATION study for the INCRAFT low-profile endovascular aortic stentgraft system. J Vasc Surg. 2021;73(3):867-73 e2.","journal-title":"J Vasc Surg."},{"key":"523_CR7","doi-asserted-by":"crossref","unstructured":"Torsello G, Pratesi G, van der Meulen S, Ouriel K, collaborators It. Aortoiliac remodeling and 5-year outcome of an ultralow-profile endograft. J Vasc Surg. 2019;69(6):1747\u201357.","DOI":"10.1016\/j.jvs.2018.09.059"},{"issue":"4","key":"523_CR8","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1053\/j.semvascsurg.2012.09.006","volume":"25","author":"DJ Minion","year":"2012","unstructured":"Minion DJ, Davenport DL. Access techniques for EVAR: percutaneous techniques and working with small arteries. Semin Vasc Surg. 2012;25(4):208\u201316.","journal-title":"Semin Vasc Surg"},{"issue":"4","key":"523_CR9","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1016\/j.jvs.2021.09.036","volume":"75","author":"G de Donato","year":"2022","unstructured":"de Donato G, Pasqui E, Nano G, Lenti M, Mangialardi N, Speziale F, et al. Long-term results of treatment of infrarenal aortic aneurysms with low-profile stentgrafts in a multicenter registry. J Vasc Surg. 2022;75(4):1242-52 e2.","journal-title":"J Vasc Surg."},{"key":"523_CR10","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.carrev.2023.12.016","volume":"62","author":"T Unoki","year":"2024","unstructured":"Unoki T, Konami Y, Nakayama T, Suzuyama H, Horio E, Taguchi E, et al. Efficacy and safety of post-closure technique using Perclose ProGlide\/ProStyle device for large-bore mechanical circulatory support access sites. Cardiovasc Revasc Med. 2024;62:60\u20135.","journal-title":"Cardiovasc Revasc Med"},{"issue":"3","key":"523_CR11","first-page":"CD009541","volume":"3","author":"L Robertson","year":"2016","unstructured":"Robertson L, Andras A, Colgan F, Jackson R. Vascular closure devices for femoral arterial puncture site haemostasis. Cochrane Database Syst Rev. 2016;3(3):CD009541.","journal-title":"Cochrane Database Syst Rev."},{"issue":"5","key":"523_CR12","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1016\/j.jvs.2007.12.029","volume":"47","author":"WA Lee","year":"2008","unstructured":"Lee WA, Brown MP, Nelson PR, Huber TS, Seeger JM. Midterm outcomes of femoral arteries after percutaneous endovascular aortic repair using the Preclose technique. J Vasc Surg. 2008;47(5):919\u201323.","journal-title":"J Vasc Surg"},{"issue":"5","key":"523_CR13","first-page":"705","volume":"55","author":"L Bertoglio","year":"2014","unstructured":"Bertoglio L, Logaldo D, Marone EM, Rinaldi E, Chiesa R. Technical features of the INCRAFT AAA Stentgraft System. J Cardiovasc Surg (Torino). 2014;55(5):705\u201315.","journal-title":"J Cardiovasc Surg (Torino)"},{"issue":"5","key":"523_CR14","first-page":"661","volume":"52","author":"G Torsello","year":"2011","unstructured":"Torsello G, Brunkwall J, Scheinert D. Cordis INCRAFT ultra-low profile AAA stent-graft system. J Cardiovasc Surg (Torino). 2011;52(5):661\u20137.","journal-title":"J Cardiovasc Surg (Torino)"},{"issue":"11","key":"523_CR15","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1007\/s00270-023-03570-3","volume":"46","author":"C Xu","year":"2023","unstructured":"Xu C, Zhang ZX, Gu YM, Yu JF, Fang CW, Xu GX, Jin YQ. Dual suture versus suture and plug closure devices for large bore access haemostasis during percutaneous access endovascular aneurysm repair. Cardiovasc Intervent Radiol. 2023;46(11):1553\u201361.","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"2","key":"523_CR16","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1177\/15385744231189356","volume":"58","author":"W Garabet","year":"2024","unstructured":"Garabet W, Arnautovic A, Meurer L, Mulorz J, Rembe JD, Duran M, et al. Analysis of determinants for suture-mediated closure device failure during EVAR procedures. Vasc Endovascular Surg. 2024;58(2):129\u201335.","journal-title":"Vasc Endovascular Surg"},{"key":"523_CR17","doi-asserted-by":"publisher","unstructured":"Torsello G, Bertoglio L, Kellersmann R, Wever JJ, van Overhagen H, Stavroulakis K. Three-Year Safety and Efficacy of the INCRAFT Endograft for Treatment of Abdominal Aortic Aneurysms: Results of the INSIGHT Study. J Endovasc Ther. 2023:15266028231214162. https:\/\/doi.org\/10.1177\/15266028231214162. Epub ahead of print.","DOI":"10.1177\/15266028231214162"},{"key":"523_CR18","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/j.avsg.2021.07.018","volume":"79","author":"W Stomp","year":"2022","unstructured":"Stomp W, Dierikx JE, Wever JJ, van Dijk LC, van Eps RGS, Veger HTC, van Overhagen H. Percutaneous EVAR for ruptured abdominal aortic aneurysms using the Cordis INCRAFT Endograft. Ann Vasc Surg. 2022;79:273\u20138.","journal-title":"Ann Vasc Surg"},{"issue":"6","key":"523_CR19","doi-asserted-by":"publisher","first-page":"e010374","DOI":"10.1161\/CIRCOUTCOMES.123.010374","volume":"17","author":"BF Gilmore","year":"2024","unstructured":"Gilmore BF, Scali ST, D\u2019Oria M, Neal D, Schermerhorn ML, Huber TS, et al. Temporal trends and outcomes of abdominal aortic aneurysm care in the United States. Circ Cardiovasc Qual Outcomes. 2024;17(6):e010374.","journal-title":"Circ Cardiovasc Qual Outcomes"}],"container-title":["CVIR Endovascular"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-025-00523-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42155-025-00523-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-025-00523-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,8]],"date-time":"2025-02-08T08:47:03Z","timestamp":1739004423000},"score":1,"resource":{"primary":{"URL":"https:\/\/CVIRendovasc.springeropen.com\/articles\/10.1186\/s42155-025-00523-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,8]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["523"],"URL":"https:\/\/doi.org\/10.1186\/s42155-025-00523-4","relation":{},"ISSN":["2520-8934"],"issn-type":[{"value":"2520-8934","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,8]]},"assertion":[{"value":"29 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 February 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was approved by the Medical Ethics Review Committee South-West Holland and the study was registered at the Netherlands Trial Register under trial ID NL-8044.All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.Informed consent was obtained from all individual participants included in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent for publication was obtained for every individual person\u2019s data included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11"}}