{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T00:02:36Z","timestamp":1768521756051,"version":"3.49.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:00:00Z","timestamp":1768435200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:00:00Z","timestamp":1768435200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CVIR Endovasc"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Removal of an adhered indwelling catheter in a totally implantable venous access device (TIVAD) can occasionally be challenging, particularly after prolonged implantation. The purpose of this paper is to present a modified endovascular technique for difficult TIVAD removal and to highlight its clinical relevance in cases where the catheter is firmly adhered to the vessel wall, making standard removal methods challenging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>Between December 2015 and April 2025, a total of 3347 TIVADs were implanted, and 367 removal procedures were conducted. Among these, 355 (96.7%) catheters were successfully removed using the standard technique. Three (0.8%) were removed using the push-in techniques, and one (0.3%) was removed using the contralateral pull-through combined with the sheath-twist technique. In 8 (2.2%), the ipsilateral pull-through technique was required after failure of the initial approaches. The ipsilateral pull-through technique was performed using an introducer sheath and a handmade loop-snare constructed from a guidewire and a seeking catheter. Patient characteristics and procedural data were collected for analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The ipsilateral pull-through technique was successfully used to remove difficult-to-remove TIVADs in 7 of 8 patients. In the remaining patient, the indwelling catheter was firmly adhered to the segment extending from the innominate vein to the superior vena cava, where antegrade flow was absent and numerous collateral vessels were present. Although the occlusion was successfully crossed, catheter removal was aborted due to severe pain and concerns about potential superior vena cava rupture. One procedure-related complication was observed: catheter fracture on follow-up computed tomography in one of the seven successful cases. No other complications were observed. The subclavian vein, innominate vein, and superior vena cava were patent on follow-up computed tomography performed for cancer evaluation. The median indwelling duration in this cohort was 2473\u00a0days (interquartile range [IQR], 2017\u20133002\u00a0days), and the median procedure time was 60\u00a0min (IQR, 45.8\u201374.8\u00a0min).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The ipsilateral pull-through technique is a useful method to detach adhered catheters during difficult TIVAD removal.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of evidence<\/jats:title>\n                    <jats:p>Level 3, Retrospective Study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s42155-025-00646-8","type":"journal-article","created":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T08:48:28Z","timestamp":1768466908000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ipsilateral pull-through technique using a handmade loop snare catheter for difficult port catheter removal"],"prefix":"10.1186","volume":"9","author":[{"given":"Tomomasa","family":"Matsuo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0597-1119","authenticated-orcid":false,"given":"Atsushi","family":"Saiga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rui","family":"Sato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhisa","family":"Asahara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Aramaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,15]]},"reference":[{"key":"646_CR1","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1177\/11297298211069256","volume":"24","author":"S Chatani","year":"2023","unstructured":"Chatani S, Tsukii R, Nagasawa K, Hasegawa T, Murata S, Kato M, et al. Difficult removal of totally implantable venous access devices in adult patients: incidence, risk factors, and management. J Vasc Access. 2023;24:1150\u20137. https:\/\/doi.org\/10.1177\/11297298211069256.","journal-title":"J Vasc Access"},{"key":"646_CR2","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1016\/j.jpedsurg.2009.03.033","volume":"44","author":"SC Huang","year":"2009","unstructured":"Huang SC, Tsai MS, Lai HS. A new technique to remove a \u201cstuck\u201d totally implantable venous access catheter. J Pediatr Surg. 2009;44:1465\u20137. https:\/\/doi.org\/10.1016\/j.jpedsurg.2009.03.033.","journal-title":"J Pediatr Surg"},{"key":"646_CR3","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1177\/112972981001100112","volume":"11","author":"JH Hong","year":"2010","unstructured":"Hong JH. An easy technique for the removal of a hemodialysis catheter stuck in central veins. J Vasc Access. 2010;11:59\u201362. https:\/\/doi.org\/10.1177\/112972981001100112.","journal-title":"J Vasc Access"},{"key":"646_CR4","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1016\/j.jvir.2016.02.021","volume":"27","author":"PA Patel","year":"2016","unstructured":"Patel PA, Parra DA, Bath R, Amaral JG, Temple MJ, John PR, et al. IR approaches to difficult removals of totally implanted venous access port catheters in children: a single-center experience. J Vasc Interv Radiol. 2016;27:876\u201381. https:\/\/doi.org\/10.1016\/j.jvir.2016.02.021.","journal-title":"J Vasc Interv Radiol"},{"key":"646_CR5","doi-asserted-by":"publisher","first-page":"1887","DOI":"10.1016\/j.jpedsurg.2013.01.050","volume":"48","author":"BK Chan","year":"2013","unstructured":"Chan BK, Rupasinghe SN, Hennessey I, Peart I, Baillie CT. Retained central venous lines (CVLs) after attempted removal: an 11-year series and literature review. J Pediatr Surg. 2013;48:1887\u201391. https:\/\/doi.org\/10.1016\/j.jpedsurg.2013.01.050.","journal-title":"J Pediatr Surg"},{"key":"646_CR6","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1016\/j.jvir.2012.04.013","volume":"23","author":"SE Ryan","year":"2012","unstructured":"Ryan SE, Hadziomerovic A, Aquino J, Cunningham I, O\u2019Kelly K, Rasuli P. Endoluminal dilation technique to remove \u201cstuck\u201d tunneled hemodialysis catheters. J Vasc Interv Radiol. 2012;23:1089\u201393. https:\/\/doi.org\/10.1016\/j.jvir.2012.04.013.","journal-title":"J Vasc Interv Radiol"},{"key":"646_CR7","doi-asserted-by":"publisher","unstructured":"Darwis P, Limengka Y, Muradi A, Telaumbanua RS, Karina. Endoluminal dilatation technique to remove stuck hemodialysis tunneled catheter: a case report from Indonesia. Int J Surg Case Rep. 2021;79:248\u201350. https:\/\/doi.org\/10.1016\/j.ijscr.2021.01.029","DOI":"10.1016\/j.ijscr.2021.01.029"},{"key":"646_CR8","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1097\/ccm.0b013e31823e99cb","volume":"40","author":"JJ Parienti","year":"2012","unstructured":"Parienti JJ, du Cheyron D, Timsit JF, Traor\u00e9 O, Kalfon P, Mimoz O, et al. Meta-analysis of subclavian insertion and nontunneled central venous catheter-associated infection risk reduction in critically ill adults. Crit Care Med. 2012;40:1627\u201334. https:\/\/doi.org\/10.1097\/ccm.0b013e31823e99cb.","journal-title":"Crit Care Med"},{"key":"646_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s12885-022-09228-6","volume":"22","author":"YB Chen","year":"2022","unstructured":"Chen YB, Bao HS, Hu TT, He Z, Wen B, Liu FT, et al. Comparison of comfort and complications of implantable venous access port (IVAP) with ultrasound guided Internal Jugular Vein (IJV) and axillary vein\/subclavian vein (AxV\/SCV) puncture in breast cancer patients: a randomized controlled study. BMC Cancer. 2022;22:248. https:\/\/doi.org\/10.1186\/s12885-022-09228-6.","journal-title":"BMC Cancer"},{"key":"646_CR10","doi-asserted-by":"publisher","first-page":"170","DOI":"10.4103\/2229-5151.164940","volume":"5","author":"C Kornbau","year":"2015","unstructured":"Kornbau C, Lee KC, Hughes GD, Firstenberg MS. Central line complications. Int J Crit Illn Inj Sci. 2015;5:170\u20138. https:\/\/doi.org\/10.4103\/2229-5151.164940.","journal-title":"Int J Crit Illn Inj Sci"},{"key":"646_CR11","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1097\/00005382-199701000-00010","volume":"12","author":"AA Bankier","year":"1997","unstructured":"Bankier AA, Mallek R, Wiesmayr MN, Fleischmann D, Kranz A, Kontrus M, et al. Azygos arch cannulation by central venous catheters: radiographic detection of malposition and subsequent complications. J Thorac Imaging. 1997;12:64\u20139. https:\/\/doi.org\/10.1097\/00005382-199701000-00010.","journal-title":"J Thorac Imaging"},{"key":"646_CR12","doi-asserted-by":"publisher","first-page":"1694","DOI":"10.1016\/j.jpedsurg.2006.05.065","volume":"41","author":"GJ Wilson","year":"2006","unstructured":"Wilson GJ, van Noesel MM, Hop WC, van de Ven C. The catheter is stuck: complications experienced during removal of a totally implantable venous access device. A single-center study in 200 children. J Pediatr Surg. 2006;41:1694\u20138. https:\/\/doi.org\/10.1016\/j.jpedsurg.2006.05.065.","journal-title":"J Pediatr Surg"},{"key":"646_CR13","doi-asserted-by":"publisher","DOI":"10.1186\/s43159-023-00254-y","volume":"19","author":"MY Awan","year":"2023","unstructured":"Awan MY, Almatar Z, AlShawa MA, Alshanafey S. Difficult removal of implantable venous access system: stepladder approach with wire stenting of a catheter\u2014single-center experience. Ann Pediatr Surg. 2023;19:23. https:\/\/doi.org\/10.1186\/s43159-023-00254-y.","journal-title":"Ann Pediatr Surg"}],"container-title":["CVIR Endovascular"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-025-00646-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42155-025-00646-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-025-00646-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T08:48:33Z","timestamp":1768466913000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s42155-025-00646-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,15]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["646"],"URL":"https:\/\/doi.org\/10.1186\/s42155-025-00646-8","relation":{},"ISSN":["2520-8934"],"issn-type":[{"value":"2520-8934","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,15]]},"assertion":[{"value":"21 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Review Board. The requirement for written informed consent was waived owing to the use of anonymized data, with an opt-out option available on the institution\u2019s website.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent for publication was not required as only anonymized data were used.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3"}}