{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T06:27:34Z","timestamp":1786775254432,"version":"build-2736575974"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T00:00:00Z","timestamp":1786752000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T00:00:00Z","timestamp":1786752000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82102046"],"award-info":[{"award-number":["82102046"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CVIR Endovasc"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To develop a patient-specific static and dynamic 3D-printing workflow for preoperative planning of endovascular repair in complex aortic disease with physician-modified stent\u00a0grafts, to assess the respective roles of rigid anatomical and dynamic models, and to explore its association with intraoperative efficiency compared with conventional image-based planning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This retrospective study included 46 consecutive patients with complex aortic disease encompassing various segments between the aortic arch and the abdominal aorta, who underwent endovascular repair with physician-modified stent\u00a0grafts. Patients were assigned to a 3D printing-guided group (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200922) or a conventional image-guided group (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200924) based on the preoperative planning strategy. In the 3D printing group, patient-specific 1:1 rigid anatomical models and compliant dynamic models were generated from computed tomography angiography data. Rigid models were used for anatomical visualization, device sizing, and fenestration planning. Dynamic models, fabricated using silicone material (Shore hardness 10A) and integrated into a pulsatile flow system, were used to simulate device passage, deployment, and device\u2013vessel interaction under physiological flow conditions. Model accuracy was evaluated by surface deviation analysis, and dynamic model performance was evaluated by Doppler-based flow comparison with in vivo measurements. The two groups were compared regarding operative time, radiation dose, contrast volume, perioperative complications, and short-term outcomes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Rigid anatomical models demonstrated high geometric fidelity, with over 97% of surface deviations within 0.2\u00a0mm compared with CTA data. Dynamic models showed close agreement with in vivo hemodynamics, with comparable peak systolic velocities at the inlet (1.48\u2009\u00b1\u20090.20\u00a0m\/s vs. 1.52\u2009\u00b1\u20090.18\u00a0m\/s,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.274), aneurysmal segment (1.20\u2009\u00b1\u20090.18\u00a0m\/s vs. 1.25\u2009\u00b1\u20090.15\u00a0m\/s,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.312), and outlet (1.35\u2009\u00b1\u20090.17\u00a0m\/s vs. 1.38\u2009\u00b1\u20090.16\u00a0m\/s,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.401). In the 3D printing-guided group, simulation findings were concordant with intraoperative findings in 21 of 22 cases. Compared with rigid static models, dynamic models provided additional planning information in anatomically challenging cases, including severe angulation of arch or neck, severe luminal stenosis or true lumen collapse, target vessels arise from the aneurysm sac, complex target vessel proximal segment and severe access tortuosity. In the exploratory clinical comparison, the 3D-printing-guided group had significantly shorter operative time (133.6\u2009\u00b1\u200943.3\u00a0min vs. 171.4\u2009\u00b1\u200972.1\u00a0min,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.039) and lower contrast volume (181.7\u2009\u00b1\u200968.6\u00a0mL vs. 234.9\u2009\u00b1\u2009101.0\u00a0mL,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.044) than the conventional image-guided group. The need for intraoperative device adjustment did not differ significantly between groups. No major adverse events occurred within 30\u00a0days in either group.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>A patient-specific dual-model 3D printing workflow combining rigid anatomical models and dynamic models is feasible for planning endovascular repair of complex aortic disease with physician-modified stent\u00a0grafts. The dynamic model provides complementary information beyond static anatomical assessment, particularly in anatomically complex cases requiring simulation of device\u2013vessel interaction. The observed reductions in operative time and contrast use suggest potential intraoperative benefits.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s42155-026-00755-y","type":"journal-article","created":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T06:05:44Z","timestamp":1786773944000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Patient-specific static and dynamic 3D-printed models for planning endovascular repair of complex aortic disease with physician-modified stent\u00a0grafts"],"prefix":"10.1186","volume":"9","author":[{"given":"Qincheng","family":"Gong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanting","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongping","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoping","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongning","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1694-2978","authenticated-orcid":false,"given":"Qing","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,15]]},"reference":[{"key":"755_CR1","doi-asserted-by":"publisher","first-page":"2865","DOI":"10.1161\/CIRCULATIONAHA.106.671859","volume":"115","author":"PE Norman","year":"2007","unstructured":"Norman PE, Powell JT. Abdominal aortic aneurysm: the prognosis in women is worse than in men. Circ. 2007;115:2865\u20139. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.106.671859.","journal-title":"Circ"},{"key":"755_CR2","doi-asserted-by":"publisher","unstructured":"Patel R, Sweeting MJ, Powell JT, Greenhalgh RM, EVAR trial investigators. Endovascular versus open repair of abdominal aortic aneurysm in 15-years' follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): a randomised controlled trial. Lancet. 2016;12;388:2366\u20132374. https:\/\/doi.org\/10.1016\/S0140-6736(16)31135-7.","DOI":"10.1016\/S0140-6736(16)31135-7"},{"key":"755_CR3","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.jvs.2017.10.044","volume":"67","author":"EL Chaikof","year":"2018","unstructured":"Chaikof EL, Dalman RL, Eskandari MK, Jackson BM, Lee WA, Mansour MA, et al. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018;67:2-77.e2. https:\/\/doi.org\/10.1016\/j.jvs.2017.10.044.","journal-title":"J Vasc Surg"},{"key":"755_CR4","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/j.ejvs.2024.03.018","volume":"67","author":"F Bastos Gon\u00e7alves","year":"2024","unstructured":"Bastos Gon\u00e7alves F, Wanhainen A. The one size fits all EVAR follow up has proven unsuccessful and is a thing of the past. Eur J Vasc Endovasc Surg. 2024;67:703\u20134. https:\/\/doi.org\/10.1016\/j.ejvs.2024.03.018.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"755_CR5","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.ejvs.2020.10.023","volume":"61","author":"D Branzan","year":"2021","unstructured":"Branzan D, Geisler A, Grunert R, Steiner S, Bausback Y, Gockel I, et al. The influence of 3D printed aortic models on the evolution of physician modified stent grafts for the urgent treatment of thoraco-abdominal and pararenal aortic pathologies. Eur J Vasc Endovasc Surg. 2021;61:407\u201312. https:\/\/doi.org\/10.1016\/j.ejvs.2020.10.023.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"755_CR6","doi-asserted-by":"publisher","unstructured":"Wippel D, Ouaret M, Gizewski ER, Kluckner M, Enzmann FK, Wipper S. Simulation based training for iliac endovascular interventions: 3D printed versus digital models. Eur J Vasc Endovasc Surg. 2025;26:S1078-5884(25)00260-6. https:\/\/doi.org\/10.1016\/j.ejvs.2025.03.026.","DOI":"10.1016\/j.ejvs.2025.03.026"},{"key":"755_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.cpcardiol.2023.102086","volume":"49","author":"A Shabbak","year":"2024","unstructured":"Shabbak A, Masoumkhani F, Fallah A, Amani-Beni R, Mohammadpour H, Shahbazi T, et al. 3D printing for cardiovascular surgery and intervention: a review article. Curr Probl Cardiol. 2024;49:102086. https:\/\/doi.org\/10.1016\/j.cpcardiol.2023.102086.","journal-title":"Curr Probl Cardiol"},{"key":"755_CR8","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1177\/15266028231161244","volume":"31","author":"DS Fu","year":"2024","unstructured":"Fu DS, Jin Y, Zhao ZH, Wang C, Shi YH, Zhou MJ, et al. Three-dimensional printing to guide fenestrated\/branched TEVAR in triple aortic arch branch reconstruction with a curative effect analysis. J Endovasc Ther. 2024;31:1088\u201397. https:\/\/doi.org\/10.1177\/15266028231161244.","journal-title":"J Endovasc Ther"},{"issue":"6","key":"755_CR9","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0304506","volume":"19","author":"SY Lee","year":"2024","unstructured":"Lee SY, Chew SCC, Lee PH, Chen HD, Huang SM, Liu CH, et al. Accuracy and feasibility in building a personalized 3D printed femoral pseudoaneurysm model for endovascular training. PLoS ONE. 2024;19(6):e0304506. https:\/\/doi.org\/10.1371\/journal.pone.0304506.","journal-title":"PLoS ONE"},{"key":"755_CR10","doi-asserted-by":"publisher","first-page":"632","DOI":"10.21037\/atm-20-7960","volume":"9","author":"H Wang","year":"2021","unstructured":"Wang H, Song H, Yang Y, Wu Z, Hu R, Chen J, et al. Hemodynamic testing using three-dimensional printing and computational fluid dynamics preoperatively may provide more information in mitral repair than traditional image dataset. Ann Transl Med. 2021;9:632. https:\/\/doi.org\/10.21037\/atm-20-7960.","journal-title":"Ann Transl Med"},{"key":"755_CR11","doi-asserted-by":"publisher","unstructured":"Yang Y, Wang H, Song H, Hu X, Hu R, Cao S, et al. A soft functional mitral valve model prepared by three-dimensional printing as an aid for an advanced mitral valve operation. Eur J Cardiothorac Surg. 2022;24;61:877\u2013885. https:\/\/doi.org\/10.1093\/ejcts\/ezab519.","DOI":"10.1093\/ejcts\/ezab519"},{"key":"755_CR12","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1115\/1.1411971","volume":"123","author":"DH Wang","year":"2001","unstructured":"Wang DH, Makaroun M, Webster MW, Vorp DA. Mechanical properties and microstructure of intraluminal thrombus from abdominal aortic aneurysm. J Biomech Eng. 2001;123:536\u20139. https:\/\/doi.org\/10.1115\/1.1411971","journal-title":"J Biomech Eng"},{"issue":"331","key":"755_CR13","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.ijcard.2021.01.029","volume":"15","author":"H Wang","year":"2021","unstructured":"Wang H, Song H, Yang Y, Wu Z, Hu R, Chen J, et al. Morphology display and hemodynamic testing using 3D printing may aid in the prediction of LVOT obstruction after mitral valve replacement. Int J Cardiol. 2021;15(331):296\u2013306. https:\/\/doi.org\/10.1016\/j.ijcard.2021.01.029.","journal-title":"Int J Cardiol"},{"key":"755_CR14","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1007\/978-3-319-23932-3","volume-title":"Physics of the Human Body","author":"Irving P. Herman","year":"2016","unstructured":"Herman IP. Cardiovascular System. In: Physics of the Human Body. 2nd ed. Springer; 2016.p.533-621. https:\/\/doi.org\/10.1007\/978-3-319-23932-3.","edition":"2nd"},{"key":"755_CR15","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1016\/j.ejvs.2020.11.018","volume":"61","author":"J Coles-Black","year":"2021","unstructured":"Coles-Black J, Barber T, Chuen J. A flexible 3D printed template to assist with physician modified endografts for FEVAR. Eur J Vasc Endovasc Surg. 2021;61:699\u2013700. https:\/\/doi.org\/10.1016\/j.ejvs.2020.11.018.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"755_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2025.01.027","author":"A Oliny","year":"2025","unstructured":"Oliny A, Fabre D, Fontaine V, Decante B, Haulon S. Pre-clinical evaluation of a new generation bridging stent for fenestrated endovascular aneurysm repair using realistic 3D printed aneurysm models. Eur J Vasc Endovasc Surg. 2025. https:\/\/doi.org\/10.1016\/j.ejvs.2025.01.027.","journal-title":"Eur J Vasc Endovasc Surg"}],"container-title":["CVIR Endovascular"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-026-00755-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42155-026-00755-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42155-026-00755-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T06:05:45Z","timestamp":1786773945000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s42155-026-00755-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,15]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["755"],"URL":"https:\/\/doi.org\/10.1186\/s42155-026-00755-y","relation":{},"ISSN":["2520-8934"],"issn-type":[{"value":"2520-8934","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,15]]},"assertion":[{"value":"7 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. This study protocol was approved by the institutional ethics committee of Renmin Hospital of Wuhan University (approval number: WDRY2020-K230). Informed consent was obtained from all individual participants included in the study.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Consent for publication was obtained for every individual person\u2019s data included in the study.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"103"}}