{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T21:36:50Z","timestamp":1794433010087,"version":"4.9.1"},"reference-count":470,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Bioelectron Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Implanted neural interfaces are electronic devices that stimulate or record from neurons with the purpose of improving the quality of life of people who suffer from neural injury or disease. Devices have been designed to interact with neurons throughout the body to treat a growing variety of conditions. The development and use of implanted neural interfaces is increasing steadily and has shown great success, with implants lasting for years to decades and improving the health and quality of life of many patient populations. Despite these successes, implanted neural interfaces face a multitude of challenges to remain effective for the lifetime of their users. The devices are comprised of several electronic and mechanical components that each may be susceptible to failure. Furthermore, implanted neural interfaces, like any foreign body, will evoke an immune response. The immune response will differ for implants in the central nervous system and peripheral nervous system, as well as over time, ultimately resulting in encapsulation of the device. This review describes the challenges faced by developers of neural interface systems, particularly devices already in use in humans. The mechanical and technological failure modes of each component of an implant system is described. The acute and chronic reactions to devices in the peripheral and central nervous system and how they affect system performance are depicted. Further, physical challenges such as micro and macro movements are reviewed. The clinical implications of device failures are summarized and a guide for determining the severity of complication was developed and provided. Common methods to diagnose and examine mechanical, technological, and biological failure modes at various stages of development and testing are outlined, with an emphasis on chronic in vivo characterization of implant systems. Finally, this review concludes with an overview of some of the innovative solutions developed to reduce or resolve the challenges faced by implanted neural interface systems.<\/jats:p>","DOI":"10.1186\/s42234-025-00168-7","type":"journal-article","created":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T20:03:27Z","timestamp":1741896207000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Overcoming failure: improving acceptance and success of implanted neural interfaces"],"prefix":"10.1186","volume":"11","author":[{"given":"Ashley N.","family":"Dalrymple","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonny T.","family":"Jones","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James B.","family":"Fallon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert K.","family":"Shepherd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas J.","family":"Weber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,14]]},"reference":[{"key":"168_CR1","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1002\/smll.200901868","volume":"6","author":"MR Abidian","year":"2010","unstructured":"Abidian MR, Corey JM, Kipke DR, Martin DC. Conducting-polymer nanotubes improve electrical properties, mechanical adhesion, neural attachment, and neurite outgrowth of neural electrodes. Small. 2010;6:421\u20139. https:\/\/doi.org\/10.1002\/smll.200901868.","journal-title":"Small"},{"key":"168_CR2","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1016\/S0140-6736(17)30601-3","volume":"389","author":"AB Ajiboye","year":"2017","unstructured":"Ajiboye AB, Willett FR, Young DR, Memberg WD, Murphy BA, Miller JP, Walter BL, Sweet JA, Hoyen HA, Keith MW, Peckham PH, Simeral JD, Donoghue JP, Hochberg LR, Kirsch RF. Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration. Lancet. 2017;389:1821\u201330. https:\/\/doi.org\/10.1016\/S0140-6736(17)30601-3.","journal-title":"Lancet"},{"key":"168_CR3","doi-asserted-by":"publisher","first-page":"601","DOI":"10.36076\/ppj\/2019.22.601","volume":"22","author":"A Al-Kaisy","year":"2019","unstructured":"Al-Kaisy A, Royds J, Costanzi M, Racz G, Wesley S, Palmisani S, Pang D, Yearwood T. Effectiveness of \u201cTransgrade\u201d epidural technique for dorsal root ganglion stimulation. A retrospective, single-center, case series for chronic focal neuropathic pain. Pain Physician. 2019;22:601\u201311.","journal-title":"Pain Physician"},{"key":"168_CR4","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1039\/c3lc41364k","volume":"13","author":"A Altuna","year":"2013","unstructured":"Altuna A, Bellistri E, Cid E, Aivar P, Gal B, Berganzo J, Gabriel G, Guimer\u00e0 A, Villa R, Fern\u00e1ndez LJ, Menendez de la Prida L. SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain. Lab Chip. 2013;13:1422\u201330. https:\/\/doi.org\/10.1039\/c3lc41364k.","journal-title":"Lab Chip"},{"key":"168_CR5","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.smim.2007.11.004","volume":"20","author":"JM Anderson","year":"2008","unstructured":"Anderson JM, Rodriguez A, Chang DT. Foreign body reaction to biomaterials. Semin Immunol. 2008a;20:86\u2013100. https:\/\/doi.org\/10.1016\/j.smim.2007.11.004.","journal-title":"Semin Immunol"},{"key":"168_CR6","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1089\/neu.2007.0488","volume":"25","author":"KJ Anderson","year":"2008","unstructured":"Anderson KJ, Scheff SW, Miller KM, Roberts KN, Gilmer LK, Yang C, Shaw G. The phosphorylated axonal form of the neurofilament subunit NF-H (pNF-H) as a blood biomarker of traumatic brain injury. J Neurotrauma. 2008b;25:1079\u201385. https:\/\/doi.org\/10.1089\/neu.2007.0488.","journal-title":"J Neurotrauma"},{"key":"168_CR7","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1056\/NEJMoa1803588","volume":"379","author":"CA Angeli","year":"2018","unstructured":"Angeli CA, Boakye M, Morton RA, Vogt J, Benton K, Chen Y, Ferreira CK, Harkema SJ. Recovery of over-ground walking after chronic motor complete spinal cord injury. N Engl J Med. 2018;379:1244\u201350. https:\/\/doi.org\/10.1056\/NEJMoa1803588.","journal-title":"N Engl J Med"},{"key":"168_CR8","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1038\/nn.2992","volume":"15","author":"P Anikeeva","year":"2011","unstructured":"Anikeeva P, Andalman AS, Witten I, Warden M, Goshen I, Grosenick L, Gunaydin LA, Frank LM, Deisseroth K. Optetrode: a multichannel readout for optogenetic control in freely moving mice. Nat Neurosci. 2011;15:163\u201370. https:\/\/doi.org\/10.1038\/nn.2992.","journal-title":"Nat Neurosci"},{"key":"168_CR9","unstructured":"ASTM. ASTM F1980\u201321: standard guide for accelerated aging of sterile barrier systems and medical devices. 2021. https:\/\/www.astm.org\/f1980-21.html."},{"key":"168_CR10","unstructured":"ASTM. ASTM D3359\u201322: standard test methods for rating adhesion by tape test. 2022. https:\/\/www.astm.org\/d3359-22.html."},{"key":"168_CR11","unstructured":"ASTM. ASTM E606\/E606M-12: standard test method for strain-controlled fatigue testing. 2020. https:\/\/www.astm.org\/e0606_e0606m-12.html."},{"key":"168_CR12","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1111\/ner.13528","volume":"25","author":"CW Austelle","year":"2022","unstructured":"Austelle CW, O\u2019Leary GH, Thompson S, Gruber E, Kahn A, Manett AJ, Short B, Badran BW. A comprehensive review of vagus nerve stimulation for depression. Neuromodulation. 2022;25:309\u201315. https:\/\/doi.org\/10.1111\/ner.13528.","journal-title":"Neuromodulation"},{"key":"168_CR13","doi-asserted-by":"publisher","first-page":"e115239","DOI":"10.1371\/journal.pone.0115239","volume":"9","author":"LN Ayton","year":"2014","unstructured":"Ayton LN, Blamey PJ, Guymer RH, Luu CD, Nayagam DAX, Sinclair NC, Shivdasani MN, Yeoh J, McCombe MF, Briggs RJ, Opie NL, Villalobos J, Dimitrov PN, Varsamidis M, Petoe MA, McCarthy CD, Walker JG, Barnes N, Burkitt AN, Williams CE, Shepherd RK, Allen PJ, Bionic Vision Australia Research Consortium. First-in-human trial of a novel suprachoroidal retinal prosthesis. PLoS ONE. 2014;9:e115239. https:\/\/doi.org\/10.1371\/journal.pone.0115239.","journal-title":"PLoS ONE"},{"key":"168_CR14","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.biomaterials.2010.09.033","volume":"32","author":"E Azemi","year":"2011","unstructured":"Azemi E, Lagenaur CF, Cui XT. The surface immobilization of the neural adhesion molecule L1 on neural probes and its effect on neuronal density and gliosis at the probe\/tissue interface. Biomaterials. 2011;32:681\u201392. https:\/\/doi.org\/10.1016\/j.biomaterials.2010.09.033.","journal-title":"Biomaterials"},{"key":"168_CR15","doi-asserted-by":"publisher","first-page":"036023","DOI":"10.1088\/1741-2560\/8\/3\/036023","volume":"8","author":"J Badia","year":"2011","unstructured":"Badia J, Boretius T, Andreu D, Azevedo-Coste C, Stieglitz T, Navarro X. Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles. J Neural Eng. 2011;8: 036023. https:\/\/doi.org\/10.1088\/1741-2560\/8\/3\/036023.","journal-title":"J Neural Eng"},{"key":"168_CR16","doi-asserted-by":"publisher","first-page":"046023","DOI":"10.1088\/1741-2560\/11\/4\/046023","volume":"11","author":"DH Baek","year":"2014","unstructured":"Baek DH, Lee J, Byeon HJ, Choi H, Young Kim I, Lee KM, Jungho Pak J, Pyo Jang D, Lee SH. A thin film polyimide mesh microelectrode for chronic epidural electrocorticography recording with enhanced contactability. J Neural Eng. 2014;11:046023. https:\/\/doi.org\/10.1088\/1741-2560\/11\/4\/046023.","journal-title":"J Neural Eng"},{"key":"168_CR17","doi-asserted-by":"publisher","first-page":"5552","DOI":"10.1016\/j.biomaterials.2010.03.051","volume":"31","author":"JA Bamford","year":"2010","unstructured":"Bamford JA, Todd KG, Mushahwar VK. The effects of intraspinal microstimulation on spinal cord tissue in the rat. Biomaterials. 2010;31:5552\u201363. https:\/\/doi.org\/10.1016\/j.biomaterials.2010.03.051.","journal-title":"Biomaterials"},{"key":"168_CR18","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1109\/TNSRE.2016.2555959","volume":"25","author":"JA Bamford","year":"2017","unstructured":"Bamford JA, Marc Lebel R, Parseyan K, Mushahwar VK. The fabrication, implantation, and stability of intraspinal microwire arrays in the spinal cord of cat and rat. IEEE Trans Neural Syst Rehabil Eng. 2017;25:287\u201396. https:\/\/doi.org\/10.1109\/TNSRE.2016.2555959.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"168_CR19","first-page":"97","volume":"42","author":"S Barlas","year":"2017","unstructured":"Barlas S. FDA flags inconsistent hospital reporting of medical device problems. P T. 2017;42:97\u2013115.","journal-title":"P T"},{"key":"168_CR20","first-page":"29","volume":"51","author":"G Barolat","year":"1988","unstructured":"Barolat G, Myklebust JB, Wenninger W. Effects of spinal cord stimulation on spasticity and spasms secondary to myelopathy. Appl Neurophysiol. 1988;51:29\u201344.","journal-title":"Appl Neurophysiol"},{"key":"168_CR21","doi-asserted-by":"publisher","first-page":"066014","DOI":"10.1088\/1741-2560\/10\/6\/066014","volume":"10","author":"JC Barrese","year":"2013","unstructured":"Barrese JC, Rao N, Paroo K, Triebwasser C, Vargas-Irwin C, Franquemont L, Donoghue JP. Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates. J Neural Eng. 2013;10:066014. https:\/\/doi.org\/10.1088\/1741-2560\/10\/6\/066014.","journal-title":"J Neural Eng"},{"key":"168_CR22","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1167\/jov.23.11.35","volume":"23","author":"MP Barry","year":"2023","unstructured":"Barry MP, Sadeghi R, Towle VL, Stipp K, Grant P, Lane FJ, Szlyk JP, Dagnelie G, Troyk PR. Contributed session III: characteristics of electrically-induced visual percepts in the first human with the intracortical visual prosthesis. J Vis. 2023;23:35. https:\/\/doi.org\/10.1167\/jov.23.11.35.","journal-title":"J vis"},{"key":"168_CR23","doi-asserted-by":"publisher","first-page":"303","DOI":"10.3389\/fncel.2015.00303","volume":"9","author":"E Bas","year":"2015","unstructured":"Bas E, Goncalves S, Adams M, Dinh CT, Bas JM, Van De Water TR, Eshraghi AA. Spiral ganglion cells and macrophages initiate neuro-inflammation and scarring following cochlear implantation. Front Cell Neurosci. 2015;9:303. https:\/\/doi.org\/10.3389\/fncel.2015.00303.","journal-title":"Front Cell Neurosci"},{"key":"168_CR24","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s12984-023-01295-5","volume":"21","author":"L Becerra-Fajardo","year":"2024","unstructured":"Becerra-Fajardo L, Minguillon J, Krob MO, Rodrigues C, Gonz\u00e1lez-S\u00e1nchez M, Meg\u00eda-Garc\u00eda \u00c1, Gal\u00e1n CR, Henares FG, Comerma A, Del-Ama AJ, Gil-Agudo A, Grandas F, Schneider-Ickert A, Barroso FO, Ivorra A. First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction. J Neuroeng Rehabil. 2024;21:4. https:\/\/doi.org\/10.1186\/s12984-023-01295-5.","journal-title":"J Neuroeng Rehabil"},{"key":"168_CR25","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.biomaterials.2018.02.014","volume":"163","author":"HW Bedell","year":"2018","unstructured":"Bedell HW, Hermann JK, Ravikumar M, Lin S, Rein A, Li X, Molinich E, Smith PD, Selkirk SM, Miller RH, Sidik S, Taylor DM, Capadona JR. Targeting CD14 on blood derived cells improves intracortical microelectrode performance. Biomaterials. 2018a;163:163\u201373. https:\/\/doi.org\/10.1016\/j.biomaterials.2018.02.014.","journal-title":"Biomaterials"},{"key":"168_CR26","doi-asserted-by":"publisher","first-page":"772","DOI":"10.3389\/fnins.2018.00772","volume":"12","author":"HW Bedell","year":"2018","unstructured":"Bedell HW, Song S, Li X, Molinich E, Lin S, Stiller A, Danda V, Ecker M, Shoffstall AJ, Voit WE, Pancrazio JJ, Capadona JR. Understanding the effects of both CD14-mediated innate immunity and device\/tissue mechanical mismatch in the neuroinflammatory response to intracortical microelectrodes. Front Neurosci. 2018b;12:772. https:\/\/doi.org\/10.3389\/fnins.2018.00772.","journal-title":"Front Neurosci"},{"key":"168_CR27","doi-asserted-by":"publisher","first-page":"2756","DOI":"10.1109\/TUFFC.2022.3197705","volume":"69","author":"BC Benedict","year":"2022","unstructured":"Benedict BC, Ghanbari MM, Muller R. Phased array beamforming methods for powering biomedical ultrasonic implants. IEEE Trans Ultrason Ferroelectr Freq Control. 2022;69:2756\u201365. https:\/\/doi.org\/10.1109\/TUFFC.2022.3197705.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"168_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.biomaterials.2018.02.036","volume":"164","author":"C Bennett","year":"2018","unstructured":"Bennett C, Samikkannu M, Mohammed F, Dietrich WD, Rajguru SM, Prasad A. Blood brain barrier (BBB)-disruption in intracortical silicon microelectrode implants. Biomaterials. 2018;164:1\u201310. https:\/\/doi.org\/10.1016\/j.biomaterials.2018.02.036.","journal-title":"Biomaterials"},{"key":"168_CR29","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.biomaterials.2018.09.040","volume":"188","author":"C Bennett","year":"2019","unstructured":"Bennett C, Mohammed F, \u00c1lvarez-Ciara A, Nguyen MA, Dietrich WD, Rajguru SM, Streit WJ, Prasad A. Neuroinflammation, oxidative stress, and blood-brain barrier (BBB) disruption in acute Utah electrode array implants and the effect of deferoxamine as an iron chelator on acute foreign body response. Biomaterials. 2019;188:144\u201359. https:\/\/doi.org\/10.1016\/j.biomaterials.2018.09.040.","journal-title":"Biomaterials"},{"key":"168_CR30","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1159\/000098989","volume":"58","author":"MS Berger","year":"1992","unstructured":"Berger MS, Ojemann GA. Intraoperative brain mapping techniques in neuro-oncology. Stereotact Funct Neurosurg. 1992;58:153\u201361. https:\/\/doi.org\/10.1159\/000098989.","journal-title":"Stereotact Funct Neurosurg"},{"key":"168_CR31","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1212\/WNL.0000000000001280","volume":"84","author":"GK Bergey","year":"2015","unstructured":"Bergey GK, Morrell MJ, Mizrahi EM, Goldman A, King-Stephens D, Nair D, Srinivasan S, Jobst B, Gross RE, Shields DC, Barkley G, Salanova V, Olejniczak P, Cole A, Cash SS, Noe K, Wharen R, Worrell G, Murro AM, Edwards J, Duchowny M, Spencer D, Smith M, Geller E, Gwinn R, Skidmore C, Eisenschenk S, Berg M, Heck C, Van Ness P, Fountain N, Rutecki P, Massey A, O\u2019Donovan C, Labar D, Duckrow RB, Hirsch LJ, Courtney T, Sun FT, Seale CG. Long-term treatment with responsive brain stimulation in adults with refractory partial seizures. Neurology. 2015;84:810\u20137. https:\/\/doi.org\/10.1212\/WNL.0000000000001280.","journal-title":"Neurology"},{"key":"168_CR32","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.expneurol.2005.04.020","volume":"195","author":"R Biran","year":"2005","unstructured":"Biran R, Martin DC, Tresco PA. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays. Exp Neurol. 2005;195:115\u201326. https:\/\/doi.org\/10.1016\/j.expneurol.2005.04.020.","journal-title":"Exp Neurol"},{"key":"168_CR33","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1002\/jbm.a.31138","volume":"82A","author":"R Biran","year":"2007","unstructured":"Biran R, Martin DC, Tresco PA. The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. J Biomed Mater Res, Part A. 2007;82A:169\u201378. https:\/\/doi.org\/10.1002\/jbm.a.31138.","journal-title":"J Biomed Mater Res, Part A"},{"key":"168_CR34","unstructured":"Blackrock Neurotech. Utah array, electrodes | Products. Blackrock Neurotech. 2023a. URL https:\/\/blackrockneurotech.com\/products\/utah-array\/. Accessed 10.30.23."},{"key":"168_CR35","unstructured":"Blackrock Neurotech. Utah slant array, electrodes | Products. Blackrock Neurotech. 2023b. URL https:\/\/blackrockneurotech.com\/products\/slant-array\/. Accessed 10.30.23."},{"key":"168_CR36","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1038\/nrn2038","volume":"8","author":"ML Block","year":"2007","unstructured":"Block ML, Zecca L, Hong JS. Microglia-mediated neurotoxicity: uncovering the molecular mechanisms. Nat Rev Neurosci. 2007;8:57\u201369. https:\/\/doi.org\/10.1038\/nrn2038.","journal-title":"Nat Rev Neurosci"},{"key":"168_CR37","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.bios.2010.05.010","volume":"26","author":"T Boretius","year":"2010","unstructured":"Boretius T, Badia J, Pascual-Font A, Schuettler M, Navarro X, Yoshida K, Stieglitz T. A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. Biosens Bioelectron. 2010;26:62\u20139. https:\/\/doi.org\/10.1016\/j.bios.2010.05.010.","journal-title":"Biosens Bioelectron"},{"key":"168_CR38","doi-asserted-by":"publisher","unstructured":"Bose R, Dalrymple AN, Sarma D, Petersen BA, Barra B, Nanivadekar AC, Madonna TJ, Liu MF, Levy I, Helm ER, Miele VJ, Capogrosso M, Fisher LE, Weber DJ. Characterizing spinal reflexes evoked by spinal cord stimulation to restore sensation in people with lower-limb amputation. 2024. https:\/\/doi.org\/10.1101\/2023.09.08.23295273.","DOI":"10.1101\/2023.09.08.23295273"},{"key":"168_CR39","doi-asserted-by":"publisher","unstructured":"Bose R, Petersen B, Sarma D, Barra B, Nanivadekar A, Madonna T, Liu M, Levy I, Helm E, Miele V, Fisher L, Weber D, Dalrymple A. Changes in muscle activation and joint motion during walking after transtibial amputation with sensory feedback from spinal cord stimulation: a case study. 2025. https:\/\/doi.org\/10.1101\/2024.12.27.24319684.","DOI":"10.1101\/2024.12.27.24319684"},{"key":"168_CR40","unstructured":"Boston Scientific. Precision spinal cord stimulation system clinician manual. 2017."},{"key":"168_CR41","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.1111\/ejn.15941","volume":"57","author":"MP Branco","year":"2023","unstructured":"Branco MP, Geukes SH, Aarnoutse EJ, Ramsey NF, Vansteensel MJ. Nine decades of electrocorticography: a comparison between epidural and subdural recordings. Eur J Neurosci. 2023;57:1260\u201388. https:\/\/doi.org\/10.1111\/ejn.15941.","journal-title":"Eur J Neurosci"},{"key":"168_CR42","doi-asserted-by":"publisher","unstructured":"Breach CD, Wai Mun T, Lee TK, Holliday R. Moisture induced corrosion in gold and copper ball bonds, in: 2010 34th IEEE\/CPMT International Electronic Manufacturing Technology Symposium (IEMT). Presented at the 2010 34th IEEE\/CPMT International Electronic Manufacturing Technology Symposium (IEMT). 2010:1\u201311. https:\/\/doi.org\/10.1109\/IEMT.2010.5746748.","DOI":"10.1109\/IEMT.2010.5746748"},{"key":"168_CR43","doi-asserted-by":"publisher","unstructured":"Bredeson SD, Troyk PR, Suh S, Bak M. Identification and quantification of electrical leakage pathways in floating microelectrode arrays, in: 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Presented at the 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 2013:1542\u20131545. https:\/\/doi.org\/10.1109\/EMBC.2013.6609807.","DOI":"10.1109\/EMBC.2013.6609807"},{"key":"168_CR44","doi-asserted-by":"publisher","unstructured":"Bredeson S, Kanneganti A, Deku F, Cogan S, Romero-Ortega M, Troyk P. Chronic in-vivo testing of a 16-channel implantable wireless neural stimulator, in: 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Presented at the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 2015:1017\u20131020. https:\/\/doi.org\/10.1109\/EMBC.2015.7318537.","DOI":"10.1109\/EMBC.2015.7318537"},{"key":"168_CR45","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1111\/papr.13008","volume":"21","author":"C Brooker","year":"2021","unstructured":"Brooker C, Russo M, Cousins MJ, Taylor N, Holford L, Martin R, Boesel T, Sullivan R, Hanson E, Gmel GE, Shariati NH, Poree L, Parker J. ECAP-controlled closed-loop spinal cord stimulation efficacy and opioid reduction over 24-months: final results of the prospective, multicenter, open-label avalon study. Pain Pract. 2021;21:680\u201391. https:\/\/doi.org\/10.1111\/papr.13008.","journal-title":"Pain Pract"},{"key":"168_CR46","doi-asserted-by":"publisher","first-page":"12S","DOI":"10.1097\/01.prs.0000225430.42531.c2","volume":"117","author":"G Broughton","year":"2006","unstructured":"Broughton G, Janis JE, Attinger CE. The basic science of wound healing. Plast Reconstr Surg. 2006;117:12S-34S. https:\/\/doi.org\/10.1097\/01.prs.0000225430.42531.c2.","journal-title":"Plast Reconstr Surg"},{"key":"168_CR47","doi-asserted-by":"publisher","first-page":"366","DOI":"10.3171\/jns.1977.47.3.0366","volume":"47","author":"WJ Brown","year":"1977","unstructured":"Brown WJ, Babb TL, Soper HV, Lieb JP, Ottino CA, Crandall PH. Tissue reactions to long-term electrical stimulation of the cerebellum in monkeys. J Neurosurg. 1977;47:366\u201379. https:\/\/doi.org\/10.3171\/jns.1977.47.3.0366.","journal-title":"J Neurosurg"},{"key":"168_CR48","doi-asserted-by":"publisher","first-page":"1044","DOI":"10.1149\/1.2407716","volume":"117","author":"S Bruckenstein","year":"1970","unstructured":"Bruckenstein S, Miller B. An experimental study of nonuniform current distribution at rotating disk electrodes. J Electrochem Soc. 1970;117:1044. https:\/\/doi.org\/10.1149\/1.2407716.","journal-title":"J Electrochem Soc"},{"key":"168_CR49","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1109\/TBME.1977.326218","volume":"24","author":"SB Brummer","year":"1977","unstructured":"Brummer SB, Turner MJ. Electrochemical considerations for safe electrical stimulation of the nervous system with platinum electrodes. IEEE Trans Biomed Eng. 1977;24:59\u201363. https:\/\/doi.org\/10.1109\/TBME.1977.326218.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR50","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/1741-2560\/3\/1\/001","volume":"3","author":"CR Butson","year":"2006","unstructured":"Butson CR, McIntyre CC. Role of electrode design on the volume of tissue activated during deep brain stimulation. J Neural Eng. 2006;3:1\u20138. https:\/\/doi.org\/10.1088\/1741-2560\/3\/1\/001.","journal-title":"J Neural Eng"},{"key":"168_CR51","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.clinph.2005.10.007","volume":"117","author":"CR Butson","year":"2006","unstructured":"Butson CR, Maks CB, McIntyre CC. Sources and effects of electrode impedance during deep brain stimulation. Clin Neurophysiol. 2006;117:447\u201354. https:\/\/doi.org\/10.1016\/j.clinph.2005.10.007.","journal-title":"Clin Neurophysiol"},{"issue":"22","key":"168_CR52","doi-asserted-by":"publisher","first-page":"00644","DOI":"10.1016\/j.neurom.2022.03.007","volume":"S1094\u20137159","author":"JS Calvert","year":"2022","unstructured":"Calvert JS, Darie R, Parker SR, Shaaya E, Syed S, McLaughlin BL, Fridley JS, Borton DA. Spatiotemporal distribution of electrically evoked spinal compound action potentials during spinal cord stimulation. Neuromodulation. 2022;S1094\u20137159(22):00644\u201354. https:\/\/doi.org\/10.1016\/j.neurom.2022.03.007.","journal-title":"Neuromodulation"},{"key":"168_CR53","doi-asserted-by":"publisher","first-page":"254","DOI":"10.3171\/spi.2004.100.3.0254","volume":"100","author":"T Cameron","year":"2004","unstructured":"Cameron T. Safety and efficacy of spinal cord stimulation for the treatment of chronic pain: a 20-year literature review. J Neurosurg. 2004;100:254\u201367. https:\/\/doi.org\/10.3171\/spi.2004.100.3.0254.","journal-title":"J Neurosurg"},{"key":"168_CR54","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1109\/10.83588","volume":"38","author":"PK Campbell","year":"1991","unstructured":"Campbell PK, Jones KE, Huber RJ, Horch KW, Normann RA. A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array. IEEE Trans Biomed Eng. 1991;38:758\u201368. https:\/\/doi.org\/10.1109\/10.83588.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR55","doi-asserted-by":"publisher","first-page":"1370","DOI":"10.1126\/science.1153307","volume":"319","author":"JR Capadona","year":"2008","unstructured":"Capadona JR, Shanmuganathan K, Tyler DJ, Rowan SJ, Weder C. Stimuli-responsive polymer nanocomposites inspired by the sea cucumber dermis. Science. 2008;319:1370\u20134. https:\/\/doi.org\/10.1126\/science.1153307.","journal-title":"Science"},{"key":"168_CR56","doi-asserted-by":"publisher","unstructured":"Capogrosso M, Prat-Ortega G, Ensel S, Donadio S, Borda L, Boos A, Yadav P, Verma N, Ho J, Frazier-Kim S, Fields D, Fisher L, Weber D, Duong T, Weinstein S, Eliasson M, Montes J, Chen K, Clemens P, Gerzsten P, Mentis G, Pirondini E, Friedlander R. Targeted stimulation of the sensory afferents improves motoneuron function in humans with spinal muscular atrophy. 2024. Research Square Preprint. https:\/\/doi.org\/10.21203\/rs.3.rs-3970994\/v1.","DOI":"10.21203\/rs.3.rs-3970994\/v1"},{"key":"168_CR57","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1109\/TNSRE.2003.822763","volume":"12","author":"MR Carhart","year":"2004","unstructured":"Carhart MR, He J, Herman R, D\u2019Luzansky S, Willis WT. Epidural spinal-cord stimulation facilitates recovery of functional walking following incomplete spinal-cord injury. IEEE Trans Neural Syst Rehabil Eng. 2004;12:32\u201342. https:\/\/doi.org\/10.1109\/TNSRE.2003.822763.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"168_CR58","doi-asserted-by":"publisher","unstructured":"Chandrasekaran S, Nanivadekar AC, McKernan G, Helm ER, Boninger ML, Collinger JL, Gaunt RA, Fisher LE. Sensory restoration by epidural stimulation of the lateral spinal cord in upper-limb amputees. eLife. 2020;9:e54349. https:\/\/doi.org\/10.7554\/eLife.54349.","DOI":"10.7554\/eLife.54349"},{"key":"168_CR59","first-page":"99","volume":"19","author":"E Chaplin","year":"1996","unstructured":"Chaplin E. Functional neuromuscular stimulation for mobility in people with spinal cord injuries. The Parastep I System. J Spinal Cord Med. 1996;19:99\u2013105.","journal-title":"J Spinal Cord Med"},{"key":"168_CR60","doi-asserted-by":"publisher","first-page":"010501","DOI":"10.1063\/1.5138587","volume":"116","author":"CAR Chapman","year":"2020","unstructured":"Chapman CAR, Cuttaz EA, Goding JA, Green RA. Actively controlled local drug delivery using conductive polymer-based devices. Appl Phys Lett. 2020;116:010501. https:\/\/doi.org\/10.1063\/1.5138587.","journal-title":"Appl Phys Lett"},{"key":"168_CR61","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1111\/papr.13285","volume":"24","author":"KB Chapman","year":"2024","unstructured":"Chapman KB, Yousef T, Amireh A, Kallewaard JW, van Helmond N. Lead migration rate in dorsal root ganglion stimulation using lead anchoring techniques: a follow-up study. Pain Pract. 2024;24:72\u20135. https:\/\/doi.org\/10.1111\/papr.13285.","journal-title":"Pain Pract"},{"key":"168_CR62","doi-asserted-by":"publisher","first-page":"056002","DOI":"10.1088\/1741-2552\/aac964","volume":"15","author":"H Charkhkar","year":"2018","unstructured":"Charkhkar H, Shell CE, Marasco PD, Pinault GJ, Tyler DJ, Triolo RJ. High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations. J Neural Eng. 2018;15:056002. https:\/\/doi.org\/10.1088\/1741-2552\/aac964.","journal-title":"J Neural Eng"},{"key":"168_CR63","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1038\/s41597-022-01180-1","volume":"9","author":"X Chen","year":"2022","unstructured":"Chen X, Morales-Gregorio A, Sprenger J, Kleinjohann A, Sridhar S, van Albada SJ, Gr\u00fcn S, Roelfsema PR. 1024-channel electrophysiological recordings in macaque V1 and V4 during resting state. Sci Data. 2022;9:77. https:\/\/doi.org\/10.1038\/s41597-022-01180-1.","journal-title":"Sci Data"},{"key":"168_CR64","doi-asserted-by":"publisher","first-page":"045005","DOI":"10.1088\/1741-2560\/8\/4\/045005","volume":"8","author":"CA Chestek","year":"2011","unstructured":"Chestek CA, Gilja V, Nuyujukian P, Foster JD, Fan JM, Kaufman MT, Churchland MM, Rivera-Alvidrez Z, Cunningham JP, Ryu SI, Shenoy KV. Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex. J Neural Eng. 2011;8:045005. https:\/\/doi.org\/10.1088\/1741-2560\/8\/4\/045005.","journal-title":"J Neural Eng"},{"key":"168_CR65","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1007\/s10544-006-9045-z","volume":"9","author":"KC Cheung","year":"2007","unstructured":"Cheung KC. Implantable microscale neural interfaces. Biomed Microdevices. 2007;9:923\u201338. https:\/\/doi.org\/10.1007\/s10544-006-9045-z.","journal-title":"Biomed Microdevices"},{"key":"168_CR66","doi-asserted-by":"publisher","first-page":"1982","DOI":"10.1016\/j.biomaterials.2011.11.052","volume":"33","author":"JA Chikar","year":"2012","unstructured":"Chikar JA, Hendricks JL, Richardson-Burns SM, Raphael Y, Pfingst BE, Martin DC. The use of a dual PEDOT and RGD-functionalized alginate hydrogel coating to provide sustained drug delivery and improved cochlear implant function. Biomaterials. 2012;33:1982\u201390. https:\/\/doi.org\/10.1016\/j.biomaterials.2011.11.052.","journal-title":"Biomaterials"},{"key":"168_CR67","doi-asserted-by":"crossref","unstructured":"Choi EJ, Ri HS, Park H, Kim HJ, Yoon JU, Byeon GJ. Unexpected extrusion of the implantable pulse generator of the spinal cord stimulator - a case report -. Anesth Pain Med. 2021;16:103\u2013107. https:\/\/doi.org\/10.17085\/apm.20054.","DOI":"10.17085\/apm.20054"},{"key":"168_CR68","doi-asserted-by":"publisher","first-page":"4650","DOI":"10.1016\/j.actbio.2014.07.010","volume":"10","author":"MB Christensen","year":"2014","unstructured":"Christensen MB, Pearce SM, Ledbetter NM, Warren DJ, Clark GA, Tresco PA. The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve. Acta Biomater. 2014;10:4650\u201360. https:\/\/doi.org\/10.1016\/j.actbio.2014.07.010.","journal-title":"Acta Biomater"},{"key":"168_CR69","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1186\/s12984-017-0285-3","volume":"14","author":"BP Christie","year":"2017","unstructured":"Christie BP, Freeberg M, Memberg WD, Pinault GJC, Hoyen HA, Tyler DJ, Triolo RJ. Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves. J NeuroEngineering Rehabil. 2017;14:70. https:\/\/doi.org\/10.1186\/s12984-017-0285-3.","journal-title":"J NeuroEngineering Rehabil"},{"key":"168_CR70","first-page":"4069","volume":"63","author":"B Christie","year":"2022","unstructured":"Christie B, Sadeghi R, Kartha A, Caspi A, Klatzky RL, Tenore F, Billings S, Dagnelie G. Evaluating the influence of stimulation parameters on phosphene detectability for epiretinal prostheses. Invest Ophthalmol vis Sci. 2022a;63:4069-F0033.","journal-title":"Invest Ophthalmol vis Sci"},{"key":"168_CR71","doi-asserted-by":"publisher","first-page":"036033","DOI":"10.1088\/1741-2552\/ac7326","volume":"19","author":"B Christie","year":"2022","unstructured":"Christie B, Sadeghi R, Kartha A, Caspi A, Tenore FV, Klatzky RL, Dagnelie G, Billings S. Sequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only. J Neural Eng. 2022b;19:036033. https:\/\/doi.org\/10.1088\/1741-2552\/ac7326.","journal-title":"J Neural Eng"},{"key":"168_CR72","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1088\/0967-3334\/33\/6\/943","volume":"33","author":"JU Chu","year":"2012","unstructured":"Chu JU, Song KI, Han S, Lee SH, Kim J, Kang JY, Hwang D, Suh JKF, Choi K, Youn I. Improvement of signal-to-interference ratio and signal-to-noise ratio in nerve cuff electrode systems. Physiol Meas. 2012;33:943\u201367. https:\/\/doi.org\/10.1088\/0967-3334\/33\/6\/943.","journal-title":"Physiol Meas"},{"key":"168_CR73","doi-asserted-by":"publisher","first-page":"056018","DOI":"10.1088\/1741-2560\/12\/5\/056018","volume":"12","author":"T Chung","year":"2015","unstructured":"Chung T, Wang JQ, Wang J, Cao B, Li Y, Pang SW. Electrode modifications to lower electrode impedance and improve neural signal recording sensitivity. J Neural Eng. 2015;12:056018. https:\/\/doi.org\/10.1088\/1741-2560\/12\/5\/056018.","journal-title":"J Neural Eng"},{"key":"168_CR74","doi-asserted-by":"publisher","unstructured":"Cisnal A, Fraile JC, P\u00e9rez-Turiel J, Mu\u00f1oz-Martinez V, M\u00fcller C, R Ihmig F. A measurement setup and automated calculation method to determine the charge injection capacity of implantable microelectrodes. Sensors (Basel). 2018:18. https:\/\/doi.org\/10.3390\/s18124152.","DOI":"10.3390\/s18124152"},{"key":"168_CR75","doi-asserted-by":"publisher","unstructured":"Clingan JA, Patel A, Maher DP. Survey of Spinal cord stimulation hardware currently available for the treatment of chronic pain in the United States. Front Pain Res. 2020:1. https:\/\/doi.org\/10.3389\/fpain.2020.572907.","DOI":"10.3389\/fpain.2020.572907"},{"key":"168_CR76","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1146\/annurev.bioeng.10.061807.160518","volume":"10","author":"SF Cogan","year":"2008","unstructured":"Cogan SF. Neural stimulation and recording electrodes. Annu Rev Biomed Eng. 2008;10:275\u2013309. https:\/\/doi.org\/10.1146\/annurev.bioeng.10.061807.160518.","journal-title":"Annu Rev Biomed Eng"},{"key":"168_CR77","doi-asserted-by":"publisher","unstructured":"Colachis SC, Dunlap CF, Annetta NV, Tamrakar SM, Bockbrader MA, Friedenberg DA. Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis. J Neural Eng. 2021:18. https:\/\/doi.org\/10.1088\/1741-2552\/ac1add.","DOI":"10.1088\/1741-2552\/ac1add"},{"key":"168_CR78","doi-asserted-by":"publisher","first-page":"302","DOI":"10.3171\/jns.1957.14.3.0302","volume":"14","author":"JC Collias","year":"1957","unstructured":"Collias JC, Manuelidis EE. Histopathological changes produced by implanted electrodes in cat brains; comparison with histopathological changes in human and experimental puncture wounds. J Neurosurg. 1957;14:302\u201328. https:\/\/doi.org\/10.3171\/jns.1957.14.3.0302.","journal-title":"J Neurosurg"},{"key":"168_CR79","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/S0140-6736(12)61816-9","volume":"381","author":"JL Collinger","year":"2013","unstructured":"Collinger JL, Wodlinger B, Downey JE, Wang W, Tyler-Kabara EC, Weber DJ, McMorland AJ, Velliste M, Boninger ML, Schwartz AB. High-performance neuroprosthetic control by an individual with tetraplegia. Lancet. 2013;381:557\u201364. https:\/\/doi.org\/10.1016\/S0140-6736(12)61816-9.","journal-title":"Lancet"},{"key":"168_CR80","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1111\/papr.12926","volume":"20","author":"S Costandi","year":"2020","unstructured":"Costandi S, Mekhail N, Azer G, Mehanny DS, Hanna D, Salma Y, Bolash R, Saweris Y. Longevity and utilization cost of rechargeable and non-rechargeable spinal cord stimulation implants: a comparative study. Pain Pract. 2020;20:937\u201345. https:\/\/doi.org\/10.1111\/papr.12926.","journal-title":"Pain Pract"},{"key":"168_CR81","doi-asserted-by":"publisher","first-page":"2004033","DOI":"10.1002\/advs.202004033","volume":"8","author":"EA Cuttaz","year":"2021","unstructured":"Cuttaz EA, Chapman CAR, Syed O, Goding JA, Green RA. Stretchable, fully polymeric electrode arrays for peripheral nerve stimulation. Adv Sci. 2021;8:2004033. https:\/\/doi.org\/10.1002\/advs.202004033.","journal-title":"Adv Sci"},{"key":"168_CR82","doi-asserted-by":"publisher","first-page":"046006","DOI":"10.1088\/1741-2552\/ab9a9a","volume":"17","author":"P \u010cvan\u010dara","year":"2020","unstructured":"\u010cvan\u010dara P, Boretius T, L\u00f3pez-\u00c1lvarez VM, Maciejasz P, Andreu D, Raspopovic S, Petrini F, Micera S, Granata G, Fernandez E, Rossini PM, Yoshida K, Jensen W, Divoux J-L, Guiraud D, Navarro X, Stieglitz T. Stability of flexible thin-film metallization stimulation electrodes: analysis of explants after first-in-human study and improvement of in vivo performance. J Neural Eng. 2020;17:046006. https:\/\/doi.org\/10.1088\/1741-2552\/ab9a9a.","journal-title":"J Neural Eng"},{"key":"168_CR83","doi-asserted-by":"publisher","unstructured":"\u010cvan\u010dara P, Valle G, M\u00fcller M, Bartels I, Guiho T, Hiairrassary A, Petrini F, Raspopovic S, Strauss I, Granata G, Fernandez E, Rossini PM, Barbaro M, Yoshida K, Jensen W, Divoux JL, Guiraud D, Micera S, Stieglitz T. Bringing sensation to prosthetic hands\u2014chronic assessment of implanted thin-film electrodes in humans. npj Flex Electron. 2023;7:1\u201314. https:\/\/doi.org\/10.1038\/s41528-023-00284-x.","DOI":"10.1038\/s41528-023-00284-x"},{"key":"168_CR84","doi-asserted-by":"publisher","unstructured":"da Cruz L, Dorn JD, Humayun MS, Dagnelie G, Handa J, Barale PO, Sahel JA, Stanga PE, Hafezi F, Safran AB, Salzmann J, Santos A, Birch D, Spencer R, Cideciyan AV, de Juan E, Duncan JL, Eliott D, Fawzi A, Olmos de Koo LC, Ho AC, Brown G, Haller J, Regillo C, Del Priore LV, Arditi A, Greenberg RJ, Argus II Study Group. Five-year safety and performance results from the argus II retinal prosthesis system clinical trial. Ophthalmology. 2016;123:2248\u201354. https:\/\/doi.org\/10.1016\/j.ophtha.2016.06.049.","DOI":"10.1016\/j.ophtha.2016.06.049"},{"key":"168_CR85","unstructured":"Dadd F, Schuller P, Pawsey NCK, Manouchehri S. Strain relief in an implantable electrode assembly. US20110196465A1. 2011."},{"key":"168_CR86","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.4103\/1673-5374.300342","volume":"16","author":"AN Dalrymple","year":"2021","unstructured":"Dalrymple AN. Implanted devices: the importance of both electrochemical performance and biological acceptance. Neural Regen Res. 2021;16:1188\u20139. https:\/\/doi.org\/10.4103\/1673-5374.300342.","journal-title":"Neural Regen Res"},{"key":"168_CR87","doi-asserted-by":"publisher","first-page":"2041003","DOI":"10.1142\/S2424905X20410032","volume":"05","author":"AN Dalrymple","year":"2020","unstructured":"Dalrymple AN, Mushahwar VK. Intelligent control of a spinal prosthesis to restore walking after neural injury: recent work and future possibilities. J Med Robot Res. 2020;05:2041003. https:\/\/doi.org\/10.1142\/S2424905X20410032.","journal-title":"J Med Robot Res"},{"key":"168_CR88","doi-asserted-by":"publisher","first-page":"056023","DOI":"10.1088\/1741-2552\/aad872","volume":"15","author":"AN Dalrymple","year":"2018","unstructured":"Dalrymple AN, Everaert DG, Hu DS, Mushahwar VK. A speed-adaptive intraspinal microstimulation controller to restore weight-bearing stepping in a spinal cord hemisection model. J Neural Eng. 2018;15:056023. https:\/\/doi.org\/10.1088\/1741-2552\/aad872.","journal-title":"J Neural Eng"},{"key":"168_CR89","doi-asserted-by":"publisher","first-page":"016015","DOI":"10.1088\/1741-2552\/ab5163","volume":"17","author":"AN Dalrymple","year":"2019","unstructured":"Dalrymple AN, Huynh M, Robles UAA, Marroquin JB, Lee C, Petrossians A, Whalen JJ, Li D, Parkington HC, Forsythe JS, Green R, Poole-Warren LA, Shepherd RK, Fallon JB. Electrochemical and mechanical performance of reduced graphene oxide, conductive hydrogel, and electrodeposited Pt-Ir coated electrodes: an active in vitro study. J Neural Eng. 2019;17:016015. https:\/\/doi.org\/10.1088\/1741-2552\/ab5163.","journal-title":"J Neural Eng"},{"key":"168_CR90","doi-asserted-by":"publisher","unstructured":"Dalrymple AN, Huynh M, Nayagam BA, Lee C, Weiland GR, Petrossians A III, JJW, Fallon, JB, Shepherd RK. Electrochemical and biological characterization of thin-film platinum-iridium alloy electrode coatings: a chronic in vivo study. J Neural Eng. 2020a. https:\/\/doi.org\/10.1088\/1741-2552\/ab933d.","DOI":"10.1088\/1741-2552\/ab933d"},{"key":"168_CR91","doi-asserted-by":"publisher","first-page":"026018","DOI":"10.1088\/1741-2552\/ab7cfc","volume":"17","author":"AN Dalrymple","year":"2020","unstructured":"Dalrymple AN, Robles UA, Huynh M, Nayagam BA, Green RA, Poole-Warren LA, Fallon JB, Shepherd RK. Electrochemical and biological performance of chronically stimulated conductive hydrogel electrodes. J Neural Eng. 2020b;17:026018. https:\/\/doi.org\/10.1088\/1741-2552\/ab7cfc.","journal-title":"J Neural Eng"},{"key":"168_CR92","doi-asserted-by":"publisher","first-page":"036002","DOI":"10.1088\/1741-2552\/ab8e8e","volume":"17","author":"AN Dalrymple","year":"2020","unstructured":"Dalrymple AN, Roszko DA, Sutton RS, Mushahwar VK. Pavlovian control of intraspinal microstimulation to produce over-ground walking. J Neural Eng. 2020c;17:036002. https:\/\/doi.org\/10.1088\/1741-2552\/ab8e8e.","journal-title":"J Neural Eng"},{"key":"168_CR93","doi-asserted-by":"publisher","first-page":"056068","DOI":"10.1088\/1741-2552\/ac2ffb","volume":"18","author":"AN Dalrymple","year":"2021","unstructured":"Dalrymple AN, Ting JE, Bose R, Trevathan JK, Nieuwoudt S, Lempka SF, Franke M, Ludwig KA, Shoffstall AJ, Fisher LE, Weber DJ. Stimulation of the dorsal root ganglion using an Injectrode\u00ae. J Neural Eng. 2021;18:056068. https:\/\/doi.org\/10.1088\/1741-2552\/ac2ffb.","journal-title":"J Neural Eng"},{"key":"168_CR94","doi-asserted-by":"publisher","first-page":"2325","DOI":"10.1089\/neu.2018.6006","volume":"36","author":"D Darrow","year":"2019","unstructured":"Darrow D, Balser D, Netoff TI, Krassioukov A, Phillips A, Parr A, Samadani U. Epidural spinal cord stimulation facilitates immediate restoration of dormant motor and autonomic supraspinal pathways after chronic neurologically complete spinal cord injury. J Neurotrauma. 2019;36:2325\u201336. https:\/\/doi.org\/10.1089\/neu.2018.6006.","journal-title":"J Neurotrauma"},{"key":"168_CR95","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/s10544-017-0147-6","volume":"19","author":"R Daschner","year":"2017","unstructured":"Daschner R, Greppmaier U, Kokelmann M, Rudorf S, Rudorf R, Schleehauf S, Wrobel WG. Laboratory and clinical reliability of conformally coated subretinal implants. Biomed Microdevices. 2017;19:7. https:\/\/doi.org\/10.1007\/s10544-017-0147-6.","journal-title":"Biomed Microdevices"},{"key":"168_CR96","first-page":"377","volume":"7","author":"GW Dauth","year":"1977","unstructured":"Dauth GW, Defendini R, Gilman S, Tennyson VM, Kremzner L. Long-term surface stimulation of the cerebellum in the monkey. I. Light microscopic, electrophysiologic, and clinical observations. Surg Neurol. 1977;7:377\u201384.","journal-title":"Surg Neurol"},{"key":"168_CR97","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1016\/S0140-6736(21)00475-X","volume":"397","author":"J Dawson","year":"2021","unstructured":"Dawson J, Liu CY, Francisco GE, Cramer SC, Wolf SL, Dixit A, Alexander J, Ali R, Brown BL, Feng W, DeMark L, Hochberg LR, Kautz SA, Majid A, O\u2019Dell MW, Pierce D, Prudente CN, Redgrave J, Turner DL, Engineer ND, Kimberley TJ. Vagus nerve stimulation paired with rehabilitation for upper limb motor function after ischaemic stroke (VNS-REHAB): a randomised, blinded, pivotal, device trial. Lancet. 2021;397:1545\u201353. https:\/\/doi.org\/10.1016\/S0140-6736(21)00475-X.","journal-title":"Lancet"},{"key":"168_CR98","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1093\/eurheartj\/ehq391","volume":"32","author":"GM De Ferrari","year":"2011","unstructured":"De Ferrari GM, Crijns HJGM, Borggrefe M, Milasinovic G, Smid J, Zabel M, Gavazzi A, Sanzo A, Dennert R, Kuschyk J, Raspopovic S, Klein H, Swedberg K, Schwartz PJ, Investigators CMT. Chronic vagus nerve stimulation: a new and promising therapeutic approach for chronic heart failure. Eur Heart J. 2011;32:847\u201355. https:\/\/doi.org\/10.1093\/eurheartj\/ehq391.","journal-title":"Eur Heart J"},{"key":"168_CR99","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/ner.12845","volume":"22","author":"TR Deer","year":"2019","unstructured":"Deer TR, Pope JE, Lamer TJ, Grider JS, Provenzano D, Lubenow TR, FitzGerald JJ, Hunter C, Falowski S, Sayed D, Baranidharan G, Patel NK, Davis T, Green A, Pajuelo A, Epstein LJ, Harned M, Liem L, Christo PJ, Chakravarthy K, Gilmore C, Huygen F, Lee E, Metha P, Nijhuis H, Patterson DG, Petersen E, Pilitsis JG, Rowe JJ, Rupert MP, Skaribas I, Sweet J, Verrills P, Wilson D, Levy RM, Mekhail N. The neuromodulation appropriateness consensus committee on best practices for dorsal root ganglion stimulation. Neuromodulation. 2019;22:1\u201335. https:\/\/doi.org\/10.1111\/ner.12845.","journal-title":"Neuromodulation"},{"key":"168_CR100","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1111\/ner.12941","volume":"23","author":"T Deer","year":"2020","unstructured":"Deer T, Pope J, Hunter C, Falowski S, Kapural L, Kramer J, Levy R. Safety analysis of dorsal root ganglion stimulation in the treatment of chronic pain. Neuromodulation. 2020;23:239\u201344. https:\/\/doi.org\/10.1111\/ner.12941.","journal-title":"Neuromodulation"},{"key":"168_CR101","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1159\/000368905","volume":"93","author":"AV Dekopov","year":"2015","unstructured":"Dekopov AV, Shabalov VA, Tomsky AA, Hit MV, Salova EM. Chronic spinal cord stimulation in the treatment of cerebral and spinal spasticity. Stereotact Funct Neurosurg. 2015;93:133\u20139. https:\/\/doi.org\/10.1159\/000368905.","journal-title":"Stereotact Funct Neurosurg"},{"key":"168_CR102","doi-asserted-by":"publisher","unstructured":"DeMichele GA, Zhe H, Troyk PR. Integrated reliability modules used in an implantable wireless EMG sensor, in: 2013 6th International IEEE\/EMBS Conference on Neural Engineering (NER). Presented at the 2013 6th International IEEE\/EMBS Conference on Neural Engineering (NER). 2013:847\u2013850. https:\/\/doi.org\/10.1109\/NER.2013.6696067.","DOI":"10.1109\/NER.2013.6696067"},{"key":"168_CR103","doi-asserted-by":"publisher","unstructured":"DeMichele GA, Cogan SF, Troyk PR, Chen H, Hu Z. Multichannel wireless ECoG array ASIC devices, in: 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Presented at the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2014:3969\u20133972. https:\/\/doi.org\/10.1109\/EMBC.2014.6944493.","DOI":"10.1109\/EMBC.2014.6944493"},{"key":"168_CR104","doi-asserted-by":"publisher","unstructured":"Deng DY, Gulati M, Rutman M, Raz S, Rodr\u00edguez LV. Failure of sacral nerve stimulation due to migration of tined lead. J Urol. 2006. https:\/\/doi.org\/10.1016\/S0022-5347(06)00318-1.","DOI":"10.1016\/S0022-5347(06)00318-1"},{"key":"168_CR105","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.1038\/s41598-024-51617-3","volume":"14","author":"DR Deo","year":"2024","unstructured":"Deo DR, Willett FR, Avansino DT, Hochberg LR, Henderson JM, Shenoy KV. Brain control of bimanual movement enabled by recurrent neural networks. Sci Rep. 2024;14:1598. https:\/\/doi.org\/10.1038\/s41598-024-51617-3.","journal-title":"Sci Rep"},{"key":"168_CR106","doi-asserted-by":"publisher","first-page":"2443","DOI":"10.1109\/TBME.2015.2431911","volume":"62","author":"TA Desautels","year":"2015","unstructured":"Desautels TA, Choe J, Gad P, Nandra MS, Roy RR, Zhong H, Tai YC, Edgerton VR, Burdick JW. An active learning algorithm for control of epidural electrostimulation. IEEE Trans Biomed Eng. 2015;62:2443\u201355. https:\/\/doi.org\/10.1109\/TBME.2015.2431911.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR107","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.2174\/092986707780597961","volume":"14","author":"ST Dheen","year":"2007","unstructured":"Dheen ST, Kaur C, Ling EA. Microglial activation and its implications in the brain diseases. Curr Med Chem. 2007;14:1189\u201397. https:\/\/doi.org\/10.2174\/092986707780597961.","journal-title":"Curr Med Chem"},{"key":"168_CR108","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.eplepsyres.2019.02.004","volume":"153","author":"M Dibu\u00e9-Adjei","year":"2019","unstructured":"Dibu\u00e9-Adjei M, Kamp MA, Vonck K. 30 years of vagus nerve stimulation trials in epilepsy: Do we need neuromodulation-specific trial designs? Epilepsy Res. 2019;153:71\u20135. https:\/\/doi.org\/10.1016\/j.eplepsyres.2019.02.004.","journal-title":"Epilepsy Res"},{"key":"168_CR109","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1097\/01.sla.0000133083.54934.ae","volume":"240","author":"D Dindo","year":"2004","unstructured":"Dindo D, Demartines N, Clavien PA. Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg. 2004;240:205\u201313. https:\/\/doi.org\/10.1097\/01.sla.0000133083.54934.ae.","journal-title":"Ann Surg"},{"key":"168_CR110","doi-asserted-by":"publisher","unstructured":"Drew L. Elon Musk\u2019s Neuralink brain chip: what scientists think of first human trial. Nature. 2024. https:\/\/doi.org\/10.1038\/d41586-024-00304-4.","DOI":"10.1038\/d41586-024-00304-4"},{"key":"168_CR111","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1016\/j.bbr.2018.11.004","volume":"359","author":"D Drobisz","year":"2019","unstructured":"Drobisz D, Damborsk\u00e1 A. Deep brain stimulation targets for treating depression. Behav Brain Res. 2019;359:266\u201373. https:\/\/doi.org\/10.1016\/j.bbr.2018.11.004.","journal-title":"Behav Brain Res"},{"key":"168_CR112","doi-asserted-by":"publisher","first-page":"4299","DOI":"10.1523\/JNEUROSCI.2917-18.2019","volume":"39","author":"A Dubey","year":"2019","unstructured":"Dubey A, Ray S. Cortical Electrocorticogram (ECoG) Is a Local Signal. J Neurosci. 2019;39:4299\u2013311. https:\/\/doi.org\/10.1523\/JNEUROSCI.2917-18.2019.","journal-title":"J Neurosci"},{"key":"168_CR113","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1177\/1941874418809869","volume":"9","author":"S Dujari","year":"2019","unstructured":"Dujari S, Gold CA. Infected implantable pulse generator. Neurohospitalist. 2019;9:172\u20133. https:\/\/doi.org\/10.1177\/1941874418809869.","journal-title":"Neurohospitalist"},{"key":"168_CR114","doi-asserted-by":"publisher","first-page":"8077","DOI":"10.1167\/iovs.14-15391","volume":"55","author":"G Dumm","year":"2014","unstructured":"Dumm G, Fallon JB, Williams CE, Shivdasani MN. Virtual electrodes by current steering in retinal prostheses. Invest Ophthalmol vis Sci. 2014;55:8077\u201385. https:\/\/doi.org\/10.1167\/iovs.14-15391.","journal-title":"Invest Ophthalmol vis Sci"},{"key":"168_CR115","doi-asserted-by":"publisher","first-page":"574","DOI":"10.3171\/jns.1970.33.5.0574","volume":"33","author":"AM Dymond","year":"1970","unstructured":"Dymond AM, Kaechele LE, Jurist JM, Crandall PH. Brain tissue reaction to some chronically implanted metals. J Neurosurg. 1970;33:574\u201380. https:\/\/doi.org\/10.3171\/jns.1970.33.5.0574.","journal-title":"J Neurosurg"},{"key":"168_CR116","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1109\/10.141202","volume":"39","author":"DJ Edell","year":"1992","unstructured":"Edell DJ, Toi VV, McNeil VM, Clark LD. Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE Trans Biomed Eng. 1992;39:635\u201343. https:\/\/doi.org\/10.1109\/10.141202.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR117","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1093\/pm\/pnv025","volume":"17","author":"S Eldabe","year":"2016","unstructured":"Eldabe S, Buchser E, Duarte RV. Complications of spinal cord stimulation and peripheral nerve stimulation techniques: a review of the literature. Pain Med. 2016;17:325\u201336. https:\/\/doi.org\/10.1093\/pm\/pnv025.","journal-title":"Pain Med"},{"key":"168_CR118","doi-asserted-by":"publisher","first-page":"016019","DOI":"10.1088\/1741-2560\/12\/1\/016019","volume":"12","author":"A Ersen","year":"2015","unstructured":"Ersen A, Elkabes S, Freedman DS, Sahin M. Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord. J Neural Eng. 2015;12:016019. https:\/\/doi.org\/10.1088\/1741-2560\/12\/1\/016019.","journal-title":"J Neural Eng"},{"key":"168_CR119","doi-asserted-by":"publisher","first-page":"3649","DOI":"10.1167\/iovs.07-1322","volume":"49","author":"N Eter","year":"2008","unstructured":"Eter N, Engel DR, Meyer L, Helb HM, Roth F, Maurer J, Holz FG, Kurts C. In vivo visualization of dendritic cells, macrophages, and microglial cells responding to laser-induced damage in the fundus of the eye. Invest Ophthalmol vis Sci. 2008;49:3649\u201358. https:\/\/doi.org\/10.1167\/iovs.07-1322.","journal-title":"Invest Ophthalmol vis Sci"},{"key":"168_CR120","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1111\/ner.12843","volume":"22","author":"SM Falowski","year":"2019","unstructured":"Falowski SM, Provenzano DA, Xia Y, Doth AH. Spinal cord stimulation infection rate and risk factors: results from a united states payer database. Neuromodulation. 2019;22:279\u201389. https:\/\/doi.org\/10.1111\/ner.12843.","journal-title":"Neuromodulation"},{"key":"168_CR121","doi-asserted-by":"publisher","first-page":"2885","DOI":"10.1166\/jnn.2013.7409","volume":"13","author":"S Farsinezhad","year":"2013","unstructured":"Farsinezhad S, Mohammadpour A, Dalrymple AN, Geisinger J, Kar P, Brett MJ, Shankar K. Transparent anodic TiO2 nanotube arrays on plastic substrates for disposable biosensors and flexible electronics. J Nanosci Nanotechnol. 2013;13:2885\u201391. https:\/\/doi.org\/10.1166\/jnn.2013.7409.","journal-title":"J Nanosci Nanotechnol"},{"key":"168_CR122","unstructured":"FDA. Class 1 device recall VNS therapy SenTiva generator, model 1000. Center for Devices and Radiological Health. 2019. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfRes\/res.cfm?id=176637."},{"key":"168_CR123","unstructured":"FDA. Conduct a trial stimulation period before implanting a Spinal Cord Stimulator (SCS) - letter to health care providers. Center for Devices and Radiological Health. 2020. https:\/\/www.fda.gov\/medical-devices\/letters-health-care-providers\/conduct-trial-stimulation-period-implanting-spinal-cord-stimulator-scs-letter-health-care-providers."},{"key":"168_CR124","unstructured":"FDA. Abbott medical recalls proclaim and infinity IPGs for inability to exit Magnetic Resonance Imaging (MRI) mode. Center for Devices and Radiological Health. 2023. https:\/\/www.fda.gov\/medical-devices\/medical-device-recalls\/abbott-medical-recalls-proclaim-and-infinity-ipgs-inability-exit-magnetic-resonance-imaging-mri-mode."},{"key":"168_CR125","unstructured":"FDA. What is a serious adverse event? Office of the commissioner. 2024. https:\/\/www.fda.gov\/safety\/reporting-serious-problems-fda\/what-serious-adverse-event."},{"key":"168_CR126","unstructured":"FDA. Medical device recalls vagus nerve stimulator. 2025a."},{"key":"168_CR127","unstructured":"FDA. Medical device recalls spinal cord stimulator. 2025b."},{"key":"168_CR128","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1016\/j.snb.2016.12.096","volume":"243","author":"Z Fekete","year":"2017","unstructured":"Fekete Z, Pongr\u00e1cz A. Multifunctional soft implants to monitor and control neural activity in the central and peripheral nervous system: a review. Sens Actuators, B Chem. 2017;243:1214\u201323. https:\/\/doi.org\/10.1016\/j.snb.2016.12.096.","journal-title":"Sens Actuators, B Chem"},{"key":"168_CR129","doi-asserted-by":"publisher","unstructured":"Ferro MD, Proctor CM, Gonzalez A, Zhao E, Slezia A, Pas J, Dijk G, Donahue MJ, Williamson A, Malliaras GG, Giocomo L, Melosh NA. NeuroRoots, a bio-inspired, seamless brain machine interface device for long-term recording. 2018. https:\/\/doi.org\/10.1101\/460949.","DOI":"10.1101\/460949"},{"key":"168_CR130","doi-asserted-by":"publisher","first-page":"046010","DOI":"10.1088\/1741-2560\/6\/4\/046010","volume":"6","author":"LE Fisher","year":"2009","unstructured":"Fisher LE, Tyler DJ, Anderson JS, Triolo RJ. Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve. J Neural Eng. 2009;6:046010. https:\/\/doi.org\/10.1088\/1741-2560\/6\/4\/046010.","journal-title":"J Neural Eng"},{"key":"168_CR131","doi-asserted-by":"publisher","first-page":"036007","DOI":"10.1088\/1741-2560\/11\/3\/036007","volume":"11","author":"LE Fisher","year":"2014","unstructured":"Fisher LE, Ayers CA, Ciollaro M, Ventura V, Weber DJ, Gaunt RA. Chronic recruitment of primary afferent neurons by microstimulation in the feline dorsal root ganglia. J Neural Eng. 2014;11:036007. https:\/\/doi.org\/10.1088\/1741-2560\/11\/3\/036007.","journal-title":"J Neural Eng"},{"key":"168_CR132","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1126\/science.abd0380","volume":"372","author":"SN Flesher","year":"2021","unstructured":"Flesher SN, Downey JE, Weiss JM, Hughes CL, Herrera AJ, Tyler-Kabara EC, Boninger ML, Collinger JL, Gaunt RA. A brain-computer interface that evokes tactile sensations improves robotic arm control. Science. 2021;372:831\u20136. https:\/\/doi.org\/10.1126\/science.abd0380.","journal-title":"Science"},{"key":"168_CR133","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1002\/lio2.329","volume":"4","author":"MJ Foggia","year":"2019","unstructured":"Foggia MJ, Quevedo RV, Hansen MR. Intracochlear fibrosis and the foreign body response to cochlear implant biomaterials. Laryngoscope Investig Otolaryngol. 2019;4:678\u201383. https:\/\/doi.org\/10.1002\/lio2.329.","journal-title":"Laryngoscope Investig Otolaryngol"},{"key":"168_CR134","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1053\/j.scrs.2017.07.006","volume":"28","author":"L Force","year":"2017","unstructured":"Force L, da Silva G. Management of complications of sacral neuromodulation. Semin Colon Rectal Surg. 2017;28:173\u20136. https:\/\/doi.org\/10.1053\/j.scrs.2017.07.006.","journal-title":"Semin Colon Rectal Surg"},{"key":"168_CR135","doi-asserted-by":"publisher","unstructured":"Ford B. Deep brain stimulation, in: Kompoliti, K., Metman, L.V. (Eds.), Encyclopedia of movement disorders. Academic Press, Oxford. 2010:277\u2013282. https:\/\/doi.org\/10.1016\/B978-0-12-374105-9.00453-6.","DOI":"10.1016\/B978-0-12-374105-9.00453-6"},{"key":"168_CR136","doi-asserted-by":"publisher","first-page":"046019","DOI":"10.1088\/1741-2552\/aba4fc","volume":"17","author":"E Formento","year":"2020","unstructured":"Formento E, D\u2019Anna E, Gribi S, Lacour SP, Micera S. A biomimetic electrical stimulation strategy to induce asynchronous stochastic neural activity. J Neural Eng. 2020;17:046019. https:\/\/doi.org\/10.1088\/1741-2552\/aba4fc.","journal-title":"J Neural Eng"},{"key":"168_CR137","doi-asserted-by":"publisher","unstructured":"Forsyth IA, Dunston M, Lombardi G, Rind GS, Ronayne S, Wong YT, May CN, Grayden DB, Oxley T, Opie N, John SE. Evaluation of a minimally invasive endovascular neural interface for decoding motor activity, in: 2019 9th International IEEE\/EMBS Conference on Neural Engineering (NER). Presented at the 2019 9th International IEEE\/EMBS Conference on Neural Engineering (NER). 2019:750\u2013753. https:\/\/doi.org\/10.1109\/NER.2019.8717000.","DOI":"10.1109\/NER.2019.8717000"},{"key":"168_CR138","doi-asserted-by":"publisher","first-page":"1702009","DOI":"10.1002\/adfm.201702009","volume":"28","author":"L Frey","year":"2018","unstructured":"Frey L, Bandaru P, Zhang YS, O\u2019Kelly K, Khademhosseini A, Shin SR. A dual-layered microfluidic system for long-term controlled In Situ delivery of multiple anti-inflammatory factors for chronic neural applications. Adv Funct Mater. 2018;28:1702009. https:\/\/doi.org\/10.1002\/adfm.201702009.","journal-title":"Adv Funct Mater"},{"key":"168_CR139","doi-asserted-by":"publisher","unstructured":"Fu Z, Rutishauser U. Human single neuron recordings: depth electrode with microwires (\u201chybrid\u201d electrode), in: Grafman, J.H. (Ed.), Encyclopedia of the Human Brain (Second Edition). Elsevier, Oxford. 2025:42\u201358. https:\/\/doi.org\/10.1016\/B978-0-12-820480-1.00002-4.","DOI":"10.1016\/B978-0-12-820480-1.00002-4"},{"key":"168_CR140","doi-asserted-by":"publisher","first-page":"E10046","DOI":"10.1073\/pnas.1717695114","volume":"114","author":"T-M Fu","year":"2017","unstructured":"Fu T-M, Hong G, Viveros RD, Zhou T, Lieber CM. Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology. Proc Natl Acad Sci U S A. 2017;114:E10046\u201355. https:\/\/doi.org\/10.1073\/pnas.1717695114.","journal-title":"Proc Natl Acad Sci U S A"},{"key":"168_CR141","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1136\/bmjqs-2017-006481","volume":"27","author":"AR Gagliardi","year":"2018","unstructured":"Gagliardi AR, Ducey A, Lehoux P, Turgeon T, Ross S, Trbovich P, Easty A, Bell C, Urbach D. Factors influencing the reporting of adverse medical device events: qualitative interviews with physicians about higher risk implantable devices. BMJ Qual Saf. 2018;27:190\u20138. https:\/\/doi.org\/10.1136\/bmjqs-2017-006481.","journal-title":"BMJ Qual Saf"},{"key":"168_CR142","doi-asserted-by":"publisher","first-page":"066027","DOI":"10.1088\/1741-2552\/aae4b6","volume":"15","author":"J Gaire","year":"2018","unstructured":"Gaire J, Lee HC, Hilborn N, Ward R, Regan M, Otto KJ. The role of inflammation on the functionality of intracortical microelectrodes. J Neural Eng. 2018;15:066027. https:\/\/doi.org\/10.1088\/1741-2552\/aae4b6.","journal-title":"J Neural Eng"},{"key":"168_CR143","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1177\/1545968311420443","volume":"26","author":"LS Gan","year":"2012","unstructured":"Gan LS, Ravid E, Kowalczewski JA, Olson JL, Morhart M, Prochazka A. First permanent implant of nerve stimulation leads activated by surface electrodes, enabling hand grasp and release: the stimulus router neuroprosthesis. Neurorehabil Neural Repair. 2012;26:335\u201343. https:\/\/doi.org\/10.1177\/1545968311420443.","journal-title":"Neurorehabil Neural Repair"},{"key":"168_CR144","doi-asserted-by":"publisher","first-page":"e1800923","DOI":"10.1002\/adhm.201800923","volume":"7","author":"M Ganji","year":"2018","unstructured":"Ganji M, Hossain L, Tanaka A, Thunemann M, Halgren E, Gilja V, Devor A, Dayeh SA. Monolithic and scalable Au nanorod substrates improve PEDOT-metal adhesion and stability in neural electrodes. Adv Healthc Mater. 2018;7:e1800923. https:\/\/doi.org\/10.1002\/adhm.201800923.","journal-title":"Adv Healthc Mater"},{"key":"168_CR145","doi-asserted-by":"publisher","first-page":"045002","DOI":"10.1088\/1741-2552\/aab90d","volume":"15","author":"A Garcia-Sandoval","year":"2018","unstructured":"Garcia-Sandoval A, Pal A, Mishra AM, Sherman S, Parikh AR, Joshi-Imre A, Arreaga-Salas D, Gutierrez-Heredia G, Duran-Martinez AC, Nathan J, Hosseini SM, Carmel JB, Voit W. Chronic softening spinal cord stimulation arrays. J Neural Eng. 2018;15:045002. https:\/\/doi.org\/10.1088\/1741-2552\/aab90d.","journal-title":"J Neural Eng"},{"key":"168_CR146","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1007\/s11916-023-01190-7","volume":"27","author":"I Garg","year":"2023","unstructured":"Garg I, Wang D. Complications of spinal cord stimulator trials and implants: a review. Curr Pain Headache Rep. 2023;27:837\u201342. https:\/\/doi.org\/10.1007\/s11916-023-01190-7.","journal-title":"Curr Pain Headache Rep"},{"key":"168_CR147","doi-asserted-by":"publisher","first-page":"3640","DOI":"10.3390\/ijms15033640","volume":"15","author":"P Gentile","year":"2014","unstructured":"Gentile P, Chiono V, Carmagnola I, Hatton PV. An overview of poly(lactic-co-glycolic) acid (PLGA)-based biomaterials for bone tissue engineering. Int J Mol Sci. 2014;15:3640\u201359. https:\/\/doi.org\/10.3390\/ijms15033640.","journal-title":"Int J Mol Sci"},{"key":"168_CR148","doi-asserted-by":"publisher","unstructured":"George JA, Kluger DT, Davis TS, Wendelken SM, Okorokova EV, He Q, Duncan CC, Hutchinson DT, Thumser ZC, Beckler DT, Marasco PD, Bensmaia SJ, Clark GA. Biomimetic sensory feedback through peripheral nerve stimulation improves dexterous use of a bionic hand. Sci Robot. 2019:4. https:\/\/doi.org\/10.1126\/scirobotics.aax2352.","DOI":"10.1126\/scirobotics.aax2352"},{"key":"168_CR149","doi-asserted-by":"publisher","first-page":"056042","DOI":"10.1088\/1741-2552\/abc025","volume":"17","author":"JA George","year":"2020","unstructured":"George JA, Page DM, Davis TS, Duncan CC, Hutchinson DT, Rieth LW, Clark GA. Long-term performance of Utah slanted electrode arrays and intramuscular electromyographic leads implanted chronically in human arm nerves and muscles. J Neural Eng. 2020;17:056042. https:\/\/doi.org\/10.1088\/1741-2552\/abc025.","journal-title":"J Neural Eng"},{"key":"168_CR150","doi-asserted-by":"publisher","unstructured":"Gilgunn PJ, Khilwani R, Kozai TDY, Weber DJ, Cui XT, Erdos G, Ozdoganlar OB, Fedder GK. An ultra-compliant, scalable neural probe with molded biodissolvable delivery vehicle, in: 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS). Presented at the 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS). 2012:56\u201359. https:\/\/doi.org\/10.1109\/MEMSYS.2012.6170092.","DOI":"10.1109\/MEMSYS.2012.6170092"},{"key":"168_CR151","doi-asserted-by":"publisher","unstructured":"Gill ML, Grahn PJ, Calvert JS, Linde MB, Lavrov IA, Strommen JA, Beck LA, Sayenko DG, Van Straaten MG, Drubach DI, Veith DD, Thoreson AR, Lopez C, Gerasimenko YP, Edgerton VR, Lee KH, Zhao KD. Neuromodulation of lumbosacral spinal networks enables independent stepping after complete paraplegia. Nat Med. 2018. https:\/\/doi.org\/10.1038\/s41591-018-0175-7.","DOI":"10.1038\/s41591-018-0175-7"},{"key":"168_CR152","doi-asserted-by":"publisher","first-page":"119519","DOI":"10.1016\/j.biomaterials.2019.119519","volume":"225","author":"A Golabchi","year":"2019","unstructured":"Golabchi A, Wu B, Cao B, Bettinger CJ, Cui XT. Zwitterionic polymer\/polydopamine coating reduce acute inflammatory tissue responses to neural implants. Biomaterials. 2019;225:119519. https:\/\/doi.org\/10.1016\/j.biomaterials.2019.119519.","journal-title":"Biomaterials"},{"key":"168_CR153","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1109\/TBME.1973.324190","volume":"20","author":"SR Goldstein","year":"1973","unstructured":"Goldstein SR, Salcman M. Mechanical factors in the design of chronic recording intracortical microelectrodes. IEEE Trans Biomed Eng. 1973;20:260\u20139. https:\/\/doi.org\/10.1109\/TBME.1973.324190.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR154","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1002\/jnr.10633","volume":"73","author":"L Goldstein","year":"2003","unstructured":"Goldstein L, Teng Z-P, Zeserson E, Patel M, Regan RF. Hemin induces an iron-dependent, oxidative injury to human neuron-like cells. J Neurosci Res. 2003;73:113\u201321. https:\/\/doi.org\/10.1002\/jnr.10633.","journal-title":"J Neurosci Res"},{"key":"168_CR155","doi-asserted-by":"publisher","unstructured":"Goodwin BJ, Mahmud R, TomThundyil S, Rivera-Colon G, Murray VW, O\u2019Donnell K. The efficacy of spinal cord stimulators in the reduction of multiple sclerosis spasticity: a narrative systematic review. Brain Neurorehabil. 2023;16:e19. https:\/\/doi.org\/10.12786\/bn.2023.16.e19.","DOI":"10.12786\/bn.2023.16.e19"},{"key":"168_CR156","doi-asserted-by":"publisher","unstructured":"Goree JH, Grant SA, Dickerson DM, Ilfeld BM, Eshraghi Y, Vaid S, Valimahomed AK, Shah JR, Smith GL, Finneran JJ, Shah NN, Guirguis MN, Eckmann MS, Antony AB, Ohlendorf BJ, Gupta M, Gilbert JE, Wongsarnpigoon A, Boggs JW. Randomized placebo-controlled trial of 60-day percutaneous peripheral nerve stimulation treatment indicates relief of persistent postoperative pain, and improved function after knee replacement. Neuromodulation. 2024. https:\/\/doi.org\/10.1016\/j.neurom.2024.03.001.","DOI":"10.1016\/j.neurom.2024.03.001"},{"key":"168_CR157","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1016\/j.neurom.2023.09.001","volume":"27","author":"L Goudman","year":"2024","unstructured":"Goudman L, Moens M, Kelly S, Young C, Pilitsis JG. Incidence of infections, explantations, and displacements\/mechanical complications of spinal cord stimulation during the past eight years. Neuromodulation. 2024;27:1082\u20139. https:\/\/doi.org\/10.1016\/j.neurom.2023.09.001.","journal-title":"Neuromodulation"},{"key":"168_CR158","doi-asserted-by":"publisher","first-page":"3637","DOI":"10.1016\/j.biomaterials.2009.03.043","volume":"30","author":"RA Green","year":"2009","unstructured":"Green RA, Lovell NH, Poole-Warren LA. Cell attachment functionality of bioactive conducting polymers for neural interfaces. Biomaterials. 2009;30:3637\u201344. https:\/\/doi.org\/10.1016\/j.biomaterials.2009.03.043.","journal-title":"Biomaterials"},{"key":"168_CR159","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1002\/mabi.201100490","volume":"12","author":"RA Green","year":"2012","unstructured":"Green RA, Hassarati RT, Goding JA, Baek S, Lovell NH, Martens PJ, Poole-Warren LA. Conductive hydrogels: mechanically robust hybrids for use as biomaterials. Macromol Biosci. 2012;12:494\u2013501. https:\/\/doi.org\/10.1002\/mabi.201100490.","journal-title":"Macromol Biosci"},{"key":"168_CR160","unstructured":"Greenberg R, Mann A, Little J, Ihrig KH, Mech B, Talbot N, Zhou D. Implantable retinal electrode array configuration for minimal retinal damage and method of reducing retinal stress. US20020111658A1. 2002."},{"key":"168_CR161","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1113\/JP277036","volume":"597","author":"CM Greenspon","year":"2019","unstructured":"Greenspon CM, Battell EE, Devonshire IM, Donaldson LF, Chapman V, Hathway GJ. Lamina-specific population encoding of cutaneous signals in the spinal dorsal horn using multi-electrode arrays. J Physiol. 2019;597:377\u201397. https:\/\/doi.org\/10.1113\/JP277036.","journal-title":"J Physiol"},{"key":"168_CR162","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1097\/IAE.0000000000000812","volume":"36","author":"NZ Gregori","year":"2016","unstructured":"Gregori NZ, Davis JL, Rizzo S. Bimanual technique for retinal tacking of epiretinal prosthesis. Retina. 2016;36:199\u2013202. https:\/\/doi.org\/10.1097\/IAE.0000000000000812.","journal-title":"Retina"},{"key":"168_CR163","doi-asserted-by":"publisher","unstructured":"Grill WM, Mortimer JT. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. J Biomed Mater Res. 2000;50:215\u201326.\u00a0https:\/\/doi.org\/10.1002\/(SICI)1097-4636(200005)50:23.0.CO;2-A.","DOI":"10.1002\/(SICI)1097-4636(200005)50:23.0.CO;2-A"},{"key":"168_CR164","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.brs.2013.07.001","volume":"7","author":"J Groothuis","year":"2014","unstructured":"Groothuis J, Ramsey NF, Ramakers GMJ, van der Plasse G. Physiological challenges for intracortical electrodes. Brain Stimul. 2014;7:1\u20136. https:\/\/doi.org\/10.1016\/j.brs.2013.07.001.","journal-title":"Brain Stimul"},{"key":"168_CR165","doi-asserted-by":"publisher","unstructured":"Haberler C, Alesch F, Mazal PR, Pilz P, Jellinger K, Pinter MM, Hainfellner JA, Budka H. No tissue damage by chronic deep brain stimulation in Parkinson\u2019s disease. Ann Neurol. 2000;48:372\u20136.\u00a0https:\/\/doi.org\/10.1002\/1531-8249(200009)48:33.0.CO;2-0.","DOI":"10.1002\/1531-8249(200009)48:33.0.CO;2-0"},{"key":"168_CR166","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1111\/j.1346-8138.2006.00133.x","volume":"33","author":"M Hamada","year":"2006","unstructured":"Hamada M, Kayashima M, Uryu M, Moroi Y, Urabe K, Furue M. Pressure cutaneous ulcer over a pacemaker successfully treated with left subcostal transplantation in an extremely thin patient. J Dermatol. 2006;33:567\u201370. https:\/\/doi.org\/10.1111\/j.1346-8138.2006.00133.x.","journal-title":"J Dermatol"},{"key":"168_CR167","doi-asserted-by":"publisher","unstructured":"Hanna J, Saad R, Sibai N. Chapter 13 - Dorsal root ganglion stimulation\u2014implant, in: Abd-Elsayed, A. (Ed.), Neuromodulation techniques for the spine. Elsevier. 2024:109\u2013119. https:\/\/doi.org\/10.1016\/B978-0-323-87584-4.00022-X.","DOI":"10.1016\/B978-0-323-87584-4.00022-X"},{"key":"168_CR168","doi-asserted-by":"publisher","unstructured":"Hanson TL, Diaz-Botia CA, Kharazia V, Maharbiz MM, Sabes PN. The \u201csewing machine\u201d for minimally invasive neural recording. 2019. https:\/\/doi.org\/10.1101\/578542.","DOI":"10.1101\/578542"},{"key":"168_CR169","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1682\/JRRD.2007.03.0333","volume":"44","author":"E Hardin","year":"2007","unstructured":"Hardin E, Kobetic R, Murray L, Corado-Ahmed M, Pinault G, Sakai J, Bailey SN, Ho C, Triolo RJ. Walking after incomplete spinal cord injury using an implanted FES system: a case report. J Rehabil Res Dev. 2007;44:333\u201346.","journal-title":"J Rehabil Res Dev"},{"key":"168_CR170","doi-asserted-by":"publisher","unstructured":"Harkema SJ, Wang S, Angeli CA, Chen Y, Boakye M, Ugiliweneza B, Hirsch GA. Normalization of blood pressure with spinal cord epidural stimulation after severe spinal cord injury. Front Hum Neurosci. 2018:12. https:\/\/doi.org\/10.3389\/fnhum.2018.00083.","DOI":"10.3389\/fnhum.2018.00083"},{"key":"168_CR171","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.jneumeth.2004.04.019","volume":"138","author":"D Harnack","year":"2004","unstructured":"Harnack D, Winter C, Meissner W, Reum T, Kupsch A, Morgenstern R. The effects of electrode material, charge density and stimulation duration on the safety of high-frequency stimulation of the subthalamic nucleus in rats. J Neurosci Methods. 2004;138:207\u201316. https:\/\/doi.org\/10.1016\/j.jneumeth.2004.04.019.","journal-title":"J Neurosci Methods"},{"key":"168_CR172","doi-asserted-by":"publisher","first-page":"066011","DOI":"10.1088\/1741-2560\/8\/6\/066011","volume":"8","author":"JP Harris","year":"2011","unstructured":"Harris JP, Capadona JR, Miller RH, Healy BC, Shanmuganathan K, Rowan SJ, Weder C, Tyler DJ. Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies. J Neural Eng. 2011a;8:066011. https:\/\/doi.org\/10.1088\/1741-2560\/8\/6\/066011.","journal-title":"J Neural Eng"},{"key":"168_CR173","doi-asserted-by":"publisher","first-page":"046010","DOI":"10.1088\/1741-2560\/8\/4\/046010","volume":"8","author":"JP Harris","year":"2011","unstructured":"Harris JP, Hess AE, Rowan SJ, Weder C, Zorman CA, Tyler DJ, Capadona JR. In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes. J Neural Eng. 2011b;8:046010. https:\/\/doi.org\/10.1088\/1741-2560\/8\/4\/046010.","journal-title":"J Neural Eng"},{"key":"168_CR174","doi-asserted-by":"publisher","first-page":"2771","DOI":"10.1007\/s10853-015-9643-3","volume":"51","author":"KD Harris","year":"2016","unstructured":"Harris KD, Elias AL, Chung H-J. Flexible electronics under strain: a review of mechanical characterization and durability enhancement strategies. J Mater Sci. 2016;51:2771\u2013805. https:\/\/doi.org\/10.1007\/s10853-015-9643-3.","journal-title":"J Mater Sci"},{"key":"168_CR175","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1109\/TNSRE.2010.2079952","volume":"19","author":"RL Hart","year":"2011","unstructured":"Hart RL, Bhadra N, Montague FW, Kilgore KL, Peckham PH. Design and testing of an advanced implantable neuroprosthesis with myoelectric control. IEEE Trans Neural Syst Rehabil Eng. 2011;19:45\u201353. https:\/\/doi.org\/10.1109\/TNSRE.2010.2079952.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"168_CR176","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1002\/polb.22169","volume":"49","author":"C Hassler","year":"2011","unstructured":"Hassler C, Boretius T, Stieglitz T. Polymers for neural implants. J Polym Sci, Part b: Polym Phys. 2011;49:18\u201333. https:\/\/doi.org\/10.1002\/polb.22169.","journal-title":"J Polym Sci, Part b: Polym Phys"},{"key":"168_CR177","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1124\/pr.57.2.4","volume":"57","author":"BT Hawkins","year":"2005","unstructured":"Hawkins BT, Davis TP. The blood-brain barrier\/neurovascular unit in health and disease. Pharmacol Rev. 2005;57:173\u201385. https:\/\/doi.org\/10.1124\/pr.57.2.4.","journal-title":"Pharmacol Rev"},{"key":"168_CR178","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1088\/1741-2560\/3\/4\/009","volume":"3","author":"W He","year":"2006","unstructured":"He W, McConnell GC, Bellamkonda RV. Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arrays. J Neural Eng. 2006;3:316\u201326. https:\/\/doi.org\/10.1088\/1741-2560\/3\/4\/009.","journal-title":"J Neural Eng"},{"key":"168_CR179","doi-asserted-by":"publisher","unstructured":"He F, Lycke R, Ganji M, Xie C, Luan L. Ultraflexible neural electrodes for long-lasting intracortical recording. iScience. 2020;23:101387. https:\/\/doi.org\/10.1016\/j.isci.2020.101387.","DOI":"10.1016\/j.isci.2020.101387"},{"key":"168_CR180","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1186\/s12984-019-0571-3","volume":"16","author":"E Heald","year":"2019","unstructured":"Heald E, Kilgore K, Hart R, Moss C, Peckham PH. Myoelectric signal from below the level of spinal cord injury as a command source for an implanted upper extremity neuroprosthesis - a case report. J NeuroEngineering Rehabil. 2019;16:100. https:\/\/doi.org\/10.1186\/s12984-019-0571-3.","journal-title":"J NeuroEngineering Rehabil"},{"key":"168_CR181","unstructured":"FDA. About Manufacturer and User Facility Device Experience (MAUDE) Database. Center for Devices and Radiological Health. 2024. https:\/\/www.fda.gov\/medical-devices\/mandatory-reporting-requirements-manufacturers-importers-and-device-user-facilities\/about-manufacturer-and-user-facility-device-experience-maude-database."},{"key":"168_CR182","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1111\/j.1525-1403.2006.00059.x","volume":"9","author":"JM Henderson","year":"2006","unstructured":"Henderson JM, Schade CM, Sasaki J, Caraway DL, Oakley JC. Prevention of mechanical failures in implanted spinal cord stimulation systems. Neuromodulation. 2006;9:183\u201391. https:\/\/doi.org\/10.1111\/j.1525-1403.2006.00059.x.","journal-title":"Neuromodulation"},{"key":"168_CR183","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.4049\/jimmunol.107.6.1547","volume":"107","author":"PM Henson","year":"1971","unstructured":"Henson PM. The immunologic release of constituents from neutrophil leukocytes. II. Mechanisms of release during phagocytosis, and adherence to nonphagocytosable surfaces. J Immunol. 1971;107:1547\u201357.","journal-title":"J Immunol"},{"key":"168_CR184","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1615\/CritRevBiomedEng.2018027166","volume":"46","author":"JK Hermann","year":"2018","unstructured":"Hermann JK, Capadona JR. Understanding the role of innate immunity in the response to intracortical microelectrodes. Crit Rev Biomed Eng. 2018;46:341\u201367. https:\/\/doi.org\/10.1615\/CritRevBiomedEng.2018027166.","journal-title":"Crit Rev Biomed Eng"},{"key":"168_CR185","doi-asserted-by":"publisher","first-page":"113","DOI":"10.3389\/fbioe.2018.00113","volume":"6","author":"JK Hermann","year":"2018","unstructured":"Hermann JK, Lin S, Soffer A, Wong C, Srivastava V, Chang J, Sunil S, Sudhakar S, Tomaszewski WH, Protasiewicz G, Selkirk SM, Miller RH, Capadona JR. The role of toll-like receptor 2 and 4 innate immunity pathways in intracortical microelectrode-induced neuroinflammation. Front Bioeng Biotechnol. 2018a;6:113. https:\/\/doi.org\/10.3389\/fbioe.2018.00113.","journal-title":"Front Bioeng Biotechnol"},{"key":"168_CR186","doi-asserted-by":"publisher","first-page":"025002","DOI":"10.1088\/1741-2552\/aaa03e","volume":"15","author":"JK Hermann","year":"2018","unstructured":"Hermann JK, Ravikumar M, Shoffstall AJ, Ereifej ES, Kovach KM, Chang J, Soffer A, Wong C, Srivastava V, Smith P, Protasiewicz G, Jiang J, Selkirk SM, Miller RH, Sidik S, Ziats NP, Taylor DM, Capadona JR. Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance. J Neural Eng. 2018b;15:025002. https:\/\/doi.org\/10.1088\/1741-2552\/aaa03e.","journal-title":"J Neural Eng"},{"key":"168_CR187","doi-asserted-by":"publisher","unstructured":"Hess AE, Potter KA, Tyler DJ, Zorman CA, Capadona JR. Environmentally-controlled microtensile testing of mechanically-adaptive polymer nanocomposites for ex vivo characterization. J Vis Exp. 2013:e50078. https:\/\/doi.org\/10.3791\/50078.","DOI":"10.3791\/50078"},{"key":"168_CR188","doi-asserted-by":"publisher","unstructured":"Hines K, Swaminathan V, Thalheimer S, Kogan M, Wu C, Sharan A. Single-center retrospective analysis of device-related complications related to dorsal root ganglion stimulation for pain relief in 31 patients. Neuromodulation: Technology at the Neural Interface. 2022;25:1040\u20131044. https:\/\/doi.org\/10.1111\/ner.13498.","DOI":"10.1111\/ner.13498"},{"key":"168_CR189","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1038\/nature04970","volume":"442","author":"LR Hochberg","year":"2006","unstructured":"Hochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, Branner A, Chen D, Penn RD, Donoghue JP. Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature. 2006;442:164\u201371. https:\/\/doi.org\/10.1038\/nature04970.","journal-title":"Nature"},{"key":"168_CR190","doi-asserted-by":"publisher","unstructured":"Hoffmann CM, Coy DS, Moeschler SM, Pingree MJ, Mauck WD. Incidence of temporary peripheral nerve stimulator lead tip retention: a retrospective review of 80 lead placements. Neuromodulation: Technology at the Neural Interface.\u00a02023;26:690\u2013693. https:\/\/doi.org\/10.1016\/j.neurom.2022.01.018.","DOI":"10.1016\/j.neurom.2022.01.018"},{"key":"168_CR191","doi-asserted-by":"publisher","first-page":"14900","DOI":"10.1038\/s41598-021-94047-1","volume":"11","author":"MK Hogan","year":"2021","unstructured":"Hogan MK, Barber SM, Rao Z, Kondiles BR, Huang M, Steele WJ, Yu C, Horner PJ. A wireless spinal stimulation system for ventral activation of the rat cervical spinal cord. Sci Rep. 2021;11:14900. https:\/\/doi.org\/10.1038\/s41598-021-94047-1.","journal-title":"Sci Rep"},{"key":"168_CR192","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.conb.2017.11.007","volume":"50","author":"G Hong","year":"2018","unstructured":"Hong G, Yang X, Zhou T, Lieber CM. Mesh electronics: a new paradigm for tissue-like brain probes. Curr Opin Neurobiol. 2018;50:33\u201341. https:\/\/doi.org\/10.1016\/j.conb.2017.11.007.","journal-title":"Curr Opin Neurobiol"},{"key":"168_CR193","doi-asserted-by":"publisher","unstructured":"Horan M, Jacobsen AH, Scherer C, Rosenlund C, Gulisano HA, S\u00f8e M, S\u00f8rensen JCH, Meier K, Blichfeldt-Eckhardt MR. Complications and effects of dorsal root ganglion stimulation in the treatment of chronic neuropathic pain: a nationwide cohort study in Denmark. Neuromodulation. 2020. https:\/\/doi.org\/10.1111\/ner.13171.","DOI":"10.1111\/ner.13171"},{"key":"168_CR194","doi-asserted-by":"publisher","first-page":"055008","DOI":"10.1088\/1741-2552\/abf398","volume":"18","author":"CC Horn","year":"2021","unstructured":"Horn CC, Forssell M, Sciullo M, Harms JE, Fulton S, Mou C, Sun F, Simpson TW, Xiao G, Fisher LE, Bettinger C, Fedder GK. Hydrogel-based electrodes for selective cervical vagus nerve stimulation. J Neural Eng. 2021;18:055008. https:\/\/doi.org\/10.1088\/1741-2552\/abf398.","journal-title":"J Neural Eng"},{"key":"168_CR195","doi-asserted-by":"publisher","unstructured":"Hosman T, Pun TK, Kapitonava A, Simeral JD, Hochberg LR. Months-long high-performance fixed LSTM decoder for cursor control in human intracortical brain-computer interfaces, in: 2023 11th International IEEE\/EMBS Conference on Neural Engineering (NER). Presented at the 2023 11th International IEEE\/EMBS Conference on Neural Engineering (NER), IEEE, Baltimore, MD, USA. 2023:1\u20135. https:\/\/doi.org\/10.1109\/NER52421.2023.10123740.","DOI":"10.1109\/NER52421.2023.10123740"},{"key":"168_CR196","doi-asserted-by":"publisher","first-page":"045012","DOI":"10.1088\/1741-2552\/ac18ad","volume":"18","author":"CL Hughes","year":"2021","unstructured":"Hughes CL, Flesher SN, Weiss JM, Downey JE, Boninger M, Collinger JL, Gaunt RA. Neural stimulation and recording performance in human sensorimotor cortex over 1500 days. J Neural Eng. 2021;18:045012. https:\/\/doi.org\/10.1088\/1741-2552\/ac18ad.","journal-title":"J Neural Eng"},{"key":"168_CR197","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1016\/j.medengphy.2008.06.001","volume":"30","author":"DWL Hukins","year":"2008","unstructured":"Hukins DWL, Mahomed A, Kukureka SN. Accelerated aging for testing polymeric biomaterials and medical devices. Med Eng Phys. 2008;30:1270\u20134. https:\/\/doi.org\/10.1016\/j.medengphy.2008.06.001.","journal-title":"Med Eng Phys"},{"key":"168_CR198","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1097\/DCR.0b013e318276b24c","volume":"56","author":"T Hull","year":"2013","unstructured":"Hull T, Giese C, Wexner SD, Mellgren A, Devroede G, Madoff RD, Stromberg K, Coller JA, SNS Study Group. Long-term durability of sacral nerve stimulation therapy for chronic fecal incontinence. Dis Colon Rectum. 2013;56:234\u201345. https:\/\/doi.org\/10.1097\/DCR.0b013e318276b24c.","journal-title":"Dis Colon Rectum"},{"key":"168_CR199","doi-asserted-by":"publisher","unstructured":"Huygen FJPM, Kallewaard JW, Nijhuis H, Liem L, Vesper J, Fahey ME, Blomme B, Morgalla MH, Deer TR, Capobianco RA. Effectiveness and safety of dorsal root ganglion stimulation for the treatment of chronic pain: a pooled analysis. Neuromodulation: Technology at the Neural Interface. 2020;23:213\u2013221. https:\/\/doi.org\/10.1111\/ner.13074.","DOI":"10.1111\/ner.13074"},{"key":"168_CR200","doi-asserted-by":"publisher","unstructured":"Hyakumura T, Aregueta-Robles U, Duan W, Villalobos J, Adams WK, Poole-Warren L, Fallon JB. Improving deep brain stimulation electrode performance in vivo through use of conductive hydrogel coatings. Front Neurosci. 2021;15:761525.\u00a0https:\/\/doi.org\/10.3389\/fnins.2021.761525.","DOI":"10.3389\/fnins.2021.761525"},{"key":"168_CR201","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1006\/exnr.1999.7212","volume":"160","author":"DL Hynds","year":"1999","unstructured":"Hynds DL, Snow DM. Neurite outgrowth inhibition by chondroitin sulfate proteoglycan: stalling\/stopping exceeds turning in human neuroblastoma growth cones. Exp Neurol. 1999;160:244\u201355. https:\/\/doi.org\/10.1006\/exnr.1999.7212.","journal-title":"Exp Neurol"},{"key":"168_CR202","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1111\/papr.12523","volume":"17","author":"BM Ilfeld","year":"2017","unstructured":"Ilfeld BM, Gabriel RA, Saulino MF, Chae J, Peckham PH, Grant SA, Gilmore CA, Donohue MC, deBock MG, Wongsarnpigoon A, Boggs JW. Infection rates of electrical leads used for percutaneous neurostimulation of the peripheral nervous system. Pain Pract. 2017;17:753\u201362. https:\/\/doi.org\/10.1111\/papr.12523.","journal-title":"Pain Pract"},{"key":"168_CR203","doi-asserted-by":"publisher","first-page":"100566","DOI":"10.1016\/j.cobme.2024.100566","volume":"32","author":"MM Iversen","year":"2024","unstructured":"Iversen MM, Harrison AT, Stanley CT, Dalrymple AN. Rehabilitation of motor and sensory function using spinal cord stimulation: recent advances. Curr Opin Biomed Eng. 2024;32:100566. https:\/\/doi.org\/10.1016\/j.cobme.2024.100566.","journal-title":"Curr Opin Biomed Eng"},{"key":"168_CR204","doi-asserted-by":"publisher","first-page":"2157","DOI":"10.1021\/bm500318d","volume":"15","author":"AF Jeffery","year":"2014","unstructured":"Jeffery AF, Churchward MA, Mushahwar VK, Todd KG, Elias AL. Hyaluronic acid-based 3D culture model for in vitro testing of electrode biocompatibility. Biomacromol. 2014;15:2157\u201365. https:\/\/doi.org\/10.1021\/bm500318d.","journal-title":"Biomacromol"},{"key":"168_CR205","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1109\/TBME.2014.2377197","volume":"62","author":"J Jeong","year":"2015","unstructured":"Jeong J, Bae SH, Min KS, Seo J-M, Chung H, Kim SJ. A miniaturized, eye-conformable, and long-term reliable retinal prosthesis using monolithic fabrication of liquid crystal polymer (LCP). IEEE Trans Biomed Eng. 2015;62:982\u20139. https:\/\/doi.org\/10.1109\/TBME.2014.2377197.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR206","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1111\/ner.12229","volume":"18","author":"C Jiang","year":"2015","unstructured":"Jiang C, Mo X, Dong Y, Meng F, Hao H, Zhang J, Feng X, Li L. An experimental study of deep brain stimulation lead fracture: possible fatigue mechanisms and prevention approach. Neuromodulation. 2015;18:243\u20138. https:\/\/doi.org\/10.1111\/ner.12229. discussion 248.","journal-title":"Neuromodulation"},{"key":"168_CR207","doi-asserted-by":"publisher","first-page":"107604","DOI":"10.1016\/j.compbiomed.2023.107604","volume":"167","author":"X Jiang","year":"2023","unstructured":"Jiang X, Fan J, Zhu Z, Wang Z, Guo Y, Liu X, Jia F, Dai C. Cybersecurity in neural interfaces: survey and future trends. Comput Biol Med. 2023;167:107604. https:\/\/doi.org\/10.1016\/j.compbiomed.2023.107604.","journal-title":"Comput Biol Med"},{"key":"168_CR208","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1080\/17434440.2019.1674139","volume":"16","author":"SE John","year":"2019","unstructured":"John SE, Grayden DB, Yanagisawa T. The future potential of the Stentrode. Expert Rev Med Devices. 2019;16:841\u20133. https:\/\/doi.org\/10.1080\/17434440.2019.1674139.","journal-title":"Expert Rev Med Devices"},{"key":"168_CR209","doi-asserted-by":"publisher","first-page":"011001","DOI":"10.1088\/1741-2560\/12\/1\/011001","volume":"12","author":"M Jorfi","year":"2015","unstructured":"Jorfi M, Skousen JL, Weder C, Capadona JR. Progress towards biocompatible intracortical microelectrodes for neural interfacing applications. J Neural Eng. 2015;12:011001. https:\/\/doi.org\/10.1088\/1741-2560\/12\/1\/011001.","journal-title":"J Neural Eng"},{"key":"168_CR210","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/j.seizure.2013.06.011","volume":"22","author":"H Kahlow","year":"2013","unstructured":"Kahlow H, Olivecrona M. Complications of vagal nerve stimulation for drug-resistant epilepsy: a single center longitudinal study of 143 patients. Seizure. 2013;22:827\u201333. https:\/\/doi.org\/10.1016\/j.seizure.2013.06.011.","journal-title":"Seizure"},{"key":"168_CR211","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1097\/WCO.0b013e3283632d08","volume":"26","author":"SK Kalia","year":"2013","unstructured":"Kalia SK, Sankar T, Lozano AM. Deep brain stimulation for Parkinson\u2019s disease and other movement disorders. Curr Opin Neurol. 2013;26:374\u201380. https:\/\/doi.org\/10.1097\/WCO.0b013e3283632d08.","journal-title":"Curr Opin Neurol"},{"key":"168_CR212","doi-asserted-by":"publisher","first-page":"2153","DOI":"10.1109\/TBME.2013.2248152","volume":"60","author":"SR Kane","year":"2013","unstructured":"Kane SR, Cogan SF, Ehrlich J, Plante TD, McCreery DB, Troyk PR. Electrical performance of penetrating microelectrodes chronically implanted in cat cortex. IEEE Trans Biomed Eng. 2013;60:2153\u201360. https:\/\/doi.org\/10.1109\/TBME.2013.2248152.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR213","doi-asserted-by":"publisher","first-page":"6179","DOI":"10.1021\/la104194m","volume":"27","author":"G Kang","year":"2011","unstructured":"Kang G, Borgens RB, Cho Y. Well-ordered porous conductive polypyrrole as a new platform for neural interfaces. Langmuir. 2011;27:6179\u201384. https:\/\/doi.org\/10.1021\/la104194m.","journal-title":"Langmuir"},{"key":"168_CR214","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1038\/nature16492","volume":"530","author":"SK Kang","year":"2016","unstructured":"Kang S-K, Murphy RKJ, Hwang S-W, Lee SM, Harburg DV, Krueger NA, Shin J, Gamble P, Cheng H, Yu S, Liu Z, McCall JG, Stephen M, Ying H, Kim J, Park G, Webb RC, Lee CH, Chung S, Wie DS, Gujar AD, Vemulapalli B, Kim AH, Lee K-M, Cheng J, Huang Y, Lee SH, Braun PV, Ray WZ, Rogers JA. Bioresorbable silicon electronic sensors for the brain. Nature. 2016;530:71\u20136. https:\/\/doi.org\/10.1038\/nature16492.","journal-title":"Nature"},{"key":"168_CR215","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1002\/jbm.820280110","volume":"28","author":"WJ Kao","year":"1994","unstructured":"Kao WJ, Zhao QH, Hiltner A, Anderson JM. Theoretical analysis of in vivo macrophage adhesion and foreign body giant cell formation on polydimethylsiloxane, low density polyethylene, and polyetherurethanes. J Biomed Mater Res. 1994;28:73\u20139. https:\/\/doi.org\/10.1002\/jbm.820280110.","journal-title":"J Biomed Mater Res"},{"key":"168_CR216","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1007\/978-3-319-18603-0_6","volume":"865","author":"M Kastellorizios","year":"2015","unstructured":"Kastellorizios M, Tipnis N, Burgess DJ. Foreign body reaction to subcutaneous implants. Adv Exp Med Biol. 2015;865:93\u2013108. https:\/\/doi.org\/10.1007\/978-3-319-18603-0_6.","journal-title":"Adv Exp Med Biol"},{"key":"168_CR217","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1109\/IEMBS.2006.259978","volume":"2006","author":"Y Kato","year":"2006","unstructured":"Kato Y, Saito I, Hoshino T, Suzuki T, Mabuchi K. Preliminary study of multichannel flexible neural probes coated with hybrid biodegradable polymer. Conf Proc IEEE Eng Med Biol Soc. 2006;2006:660\u20133. https:\/\/doi.org\/10.1109\/IEMBS.2006.259978.","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"168_CR218","doi-asserted-by":"publisher","first-page":"2904","DOI":"10.1109\/TBME.2013.2265877","volume":"60","author":"I Khaled","year":"2013","unstructured":"Khaled I, Elmallah S, Cheng C, Moussa WA, Mushahwar VK, Elias AL. A flexible base electrode array for intraspinal microstimulation. IEEE Trans Biomed Eng. 2013;60:2904\u201313. https:\/\/doi.org\/10.1109\/TBME.2013.2265877.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR219","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1111\/ner.12810","volume":"22","author":"T Khaleeq","year":"2019","unstructured":"Khaleeq T, Hasegawa H, Samuel M, Ashkan K. Fixed-life or rechargeable battery for deep brain stimulation: which do patients prefer? Neuromodulation. 2019;22:489\u201392. https:\/\/doi.org\/10.1111\/ner.12810.","journal-title":"Neuromodulation"},{"key":"168_CR220","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1682\/JRRD.2003.11.0457","volume":"40","author":"KL Kilgore","year":"2003","unstructured":"Kilgore KL, Peckham PH, Keith MW, Montague FW, Hart RL, Gazdik MM, Bryden AM, Snyder SA, Stage TG. Durability of implanted electrodes and leads in an upper-limb neuroprosthesis. J Rehabil Res Dev. 2003;40:457\u201368.","journal-title":"J Rehabil Res Dev"},{"key":"168_CR221","doi-asserted-by":"publisher","first-page":"3031","DOI":"10.1016\/j.biomaterials.2005.12.021","volume":"27","author":"D-H Kim","year":"2006","unstructured":"Kim D-H, Martin DC. Sustained release of dexamethasone from hydrophilic matrices using PLGA nanoparticles for neural drug delivery. Biomaterials. 2006;27:3031\u20137. https:\/\/doi.org\/10.1016\/j.biomaterials.2005.12.021.","journal-title":"Biomaterials"},{"key":"168_CR222","doi-asserted-by":"publisher","first-page":"2229","DOI":"10.1016\/j.biomaterials.2003.09.010","volume":"25","author":"Y-T Kim","year":"2004","unstructured":"Kim Y-T, Hitchcock RW, Bridge MJ, Tresco PA. Chronic response of adult rat brain tissue to implants anchored to the skull. Biomaterials. 2004;25:2229\u201337. https:\/\/doi.org\/10.1016\/j.biomaterials.2003.09.010.","journal-title":"Biomaterials"},{"key":"168_CR223","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.actbio.2009.07.034","volume":"6","author":"DH Kim","year":"2010","unstructured":"Kim DH, Wiler JA, Anderson DJ, Kipke DR, Martin DC. Conducting polymers on hydrogel-coated neural electrode provide sensitive neural recordings in auditory cortex. Acta Biomater. 2010;6:57\u201362. https:\/\/doi.org\/10.1016\/j.actbio.2009.07.034.","journal-title":"Acta Biomater"},{"key":"168_CR224","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1001\/jamaoto.2020.0030","volume":"146","author":"SY Kim","year":"2020","unstructured":"Kim SY, Kim MB, Chung W-H, Cho Y-S, Hong SH, Moon IJ. Evaluating reasons for revision surgery and device failure rates in patients who underwent cochlear implantation surgery. JAMA Otolaryngol Head Neck Surg. 2020;146:414\u201320. https:\/\/doi.org\/10.1001\/jamaoto.2020.0030.","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"168_CR225","doi-asserted-by":"publisher","unstructured":"Kim W, Tuppen CA, Alrashdan F, Singer A, Weirnick R, Robinson JT. Magnetoelectrics enables large power delivery to mm-sized wireless bioelectronics. 2023. bioRxiv. 2023.09.01.555944. https:\/\/doi.org\/10.1101\/2023.09.01.555944.","DOI":"10.1101\/2023.09.01.555944"},{"key":"168_CR226","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1002\/jbm.a.35958","volume":"105","author":"R Klopfleisch","year":"2017","unstructured":"Klopfleisch R, Jung F. The pathology of the foreign body reaction against biomaterials. J Biomed Mater Res A. 2017;105:927\u201340. https:\/\/doi.org\/10.1002\/jbm.a.35958.","journal-title":"J Biomed Mater Res A"},{"key":"168_CR227","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1109\/86.808942","volume":"7","author":"R Kobetic","year":"1999","unstructured":"Kobetic R, Triolo RJ, Uhlir JP, Bieri C, Wibowo M, Polando G, Marsolais EB, Davis JA, Ferguson KA. Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report. IEEE Trans Rehabil Eng. 1999;7:390\u20138. https:\/\/doi.org\/10.1109\/86.808942.","journal-title":"IEEE Trans Rehabil Eng"},{"key":"168_CR228","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.nec.2019.01.001","volume":"30","author":"M Kogan","year":"2019","unstructured":"Kogan M, McGuire M, Riley J. Deep brain stimulation for parkinson disease. Neurosurg Clin N Am. 2019;30:137\u201346. https:\/\/doi.org\/10.1016\/j.nec.2019.01.001.","journal-title":"Neurosurg Clin N Am"},{"key":"168_CR229","doi-asserted-by":"publisher","first-page":"3825","DOI":"10.1038\/s41598-018-22051-z","volume":"8","author":"WS Konerding","year":"2018","unstructured":"Konerding WS, Froriep UP, Kral A, Baumhoff P. New thin-film surface electrode array enables brain mapping with high spatial acuity in rodents. Sci Rep. 2018;8:3825. https:\/\/doi.org\/10.1038\/s41598-018-22051-z.","journal-title":"Sci Rep"},{"key":"168_CR230","doi-asserted-by":"publisher","first-page":"8284","DOI":"10.1073\/pnas.1605635113","volume":"113","author":"FA Koopman","year":"2016","unstructured":"Koopman FA, Chavan SS, Miljko S, Grazio S, Sokolovic S, Schuurman PR, Mehta AD, Levine YA, Faltys M, Zitnik R, Tracey KJ, Tak PP. Vagus nerve stimulation inhibits cytokine production and attenuates disease severity in rheumatoid arthritis. Proc Natl Acad Sci U S A. 2016;113:8284\u20139. https:\/\/doi.org\/10.1073\/pnas.1605635113.","journal-title":"Proc Natl Acad Sci U S A"},{"key":"168_CR231","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.pscychresns.2010.11.004","volume":"191","author":"M Kosel","year":"2011","unstructured":"Kosel M, Brockmann H, Frick C, Zobel A, Schlaepfer TE. Chronic vagus nerve stimulation for treatment-resistant depression increases regional cerebral blood flow in the dorsolateral prefrontal cortex. Psychiatry Res. 2011;191:153\u20139. https:\/\/doi.org\/10.1016\/j.pscychresns.2010.11.004.","journal-title":"Psychiatry Res"},{"key":"168_CR232","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.jneumeth.2009.08.002","volume":"184","author":"TDY Kozai","year":"2009","unstructured":"Kozai TDY, Kipke DR. Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain. J Neurosci Methods. 2009;184:199\u2013205. https:\/\/doi.org\/10.1016\/j.jneumeth.2009.08.002.","journal-title":"J Neurosci Methods"},{"key":"168_CR233","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1038\/nmat3468","volume":"11","author":"TDY Kozai","year":"2012","unstructured":"Kozai TDY, Langhals NB, Patel PR, Deng X, Zhang H, Smith KL, Lahann J, Kotov NA, Kipke DR. Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. Nat Mater. 2012a;11:1065\u201373. https:\/\/doi.org\/10.1038\/nmat3468.","journal-title":"Nat Mater"},{"key":"168_CR234","doi-asserted-by":"publisher","first-page":"066001","DOI":"10.1088\/1741-2560\/9\/6\/066001","volume":"9","author":"TDY Kozai","year":"2012","unstructured":"Kozai TDY, Vazquez AL, Weaver CL, Kim S-G, Cui XT. In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes. J Neural Eng. 2012b;9:066001. https:\/\/doi.org\/10.1088\/1741-2560\/9\/6\/066001.","journal-title":"J Neural Eng"},{"key":"168_CR235","doi-asserted-by":"publisher","first-page":"9255","DOI":"10.1016\/j.biomaterials.2014.07.039","volume":"35","author":"TDY Kozai","year":"2014","unstructured":"Kozai TDY, Gugel Z, Li X, Gilgunn PJ, Khilwani R, Ozdoganlar OB, Fedder GK, Weber DJ, Cui XT. Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes. Biomaterials. 2014a;35:9255\u201368. https:\/\/doi.org\/10.1016\/j.biomaterials.2014.07.039.","journal-title":"Biomaterials"},{"key":"168_CR236","doi-asserted-by":"publisher","first-page":"9620","DOI":"10.1016\/j.biomaterials.2014.08.006","volume":"35","author":"TDY Kozai","year":"2014","unstructured":"Kozai TDY, Li X, Bodily LM, Caparosa EM, Zenonos GA, Carlisle DL, Friedlander RM, Cui XT. Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response. Biomaterials. 2014b;35:9620\u201334. https:\/\/doi.org\/10.1016\/j.biomaterials.2014.08.006.","journal-title":"Biomaterials"},{"key":"168_CR237","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.biomaterials.2014.10.040","volume":"37","author":"TDY Kozai","year":"2015","unstructured":"Kozai TDY, Catt K, Li X, Gugel ZV, Olafsson VT, Vazquez AL, Cui XT. Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording. Biomaterials. 2015;37:25\u201339. https:\/\/doi.org\/10.1016\/j.biomaterials.2014.10.040.","journal-title":"Biomaterials"},{"key":"168_CR238","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.jneumeth.2015.10.007","volume":"258","author":"TDY Kozai","year":"2016","unstructured":"Kozai TDY, Eles JR, Vazquez AL, Cui XT. Two-photon imaging of chronically implanted neural electrodes: sealing methods and new insights. J Neurosci Methods. 2016;258:46\u201355. https:\/\/doi.org\/10.1016\/j.jneumeth.2015.10.007.","journal-title":"J Neurosci Methods"},{"issue":"Suppl 3","key":"168_CR239","doi-asserted-by":"publisher","first-page":"S188","DOI":"10.1002\/mds.10163","volume":"17","author":"P Krack","year":"2002","unstructured":"Krack P, Fraix V, Mendes A, Benabid AL, Pollak P. Postoperative management of subthalamic nucleus stimulation for Parkinson\u2019s disease. Mov Disord. 2002;17(Suppl 3):S188-197. https:\/\/doi.org\/10.1002\/mds.10163.","journal-title":"Mov Disord"},{"key":"168_CR240","doi-asserted-by":"publisher","unstructured":"Krukiewicz K, Chudy M, Gregg S, Biggs MJP. The synergistic effects of gold particles and dexamethasone on the electrochemical and biological performance of PEDOT neural interfaces. Polymers (Basel). 2019;11. https:\/\/doi.org\/10.3390\/polym11010067.","DOI":"10.3390\/polym11010067"},{"key":"168_CR241","doi-asserted-by":"publisher","first-page":"025006","DOI":"10.1088\/1741-2560\/8\/2\/025006","volume":"8","author":"DJ Krusienski","year":"2011","unstructured":"Krusienski DJ, Shih JJ. Control of a brain-computer interface using stereotactic depth electrodes in and adjacent to the hippocampus. J Neural Eng. 2011;8:025006. https:\/\/doi.org\/10.1088\/1741-2560\/8\/2\/025006.","journal-title":"J Neural Eng"},{"key":"168_CR242","doi-asserted-by":"publisher","first-page":"2863","DOI":"10.1002\/jnr.22132","volume":"87","author":"DP Kuffler","year":"2009","unstructured":"Kuffler DP, Sosa IJ, Reyes O. Schwann cell chondroitin sulfate proteoglycan inhibits dorsal root ganglion neuron neurite outgrowth and substrate specificity via a soma and not a growth cone mechanism. J Neurosci Res. 2009;87:2863\u201371. https:\/\/doi.org\/10.1002\/jnr.22132.","journal-title":"J Neurosci Res"},{"key":"168_CR243","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1039\/c2lc40935f","volume":"13","author":"JTW Kuo","year":"2013","unstructured":"Kuo JTW, Kim BJ, Hara SA, Lee CD, Gutierrez CA, Hoang TQ, Meng E. Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration. Lab Chip. 2013;13:554\u201361. https:\/\/doi.org\/10.1039\/c2lc40935f.","journal-title":"Lab Chip"},{"key":"168_CR244","doi-asserted-by":"publisher","first-page":"E2","DOI":"10.3171\/2018.5.FOCUS18173","volume":"45","author":"CH Kuo","year":"2018","unstructured":"Kuo CH, White-Dzuro GA, Ko AL. Approaches to closed-loop deep brain stimulation for movement disorders. Neurosurg Focus. 2018;45:E2. https:\/\/doi.org\/10.3171\/2018.5.FOCUS18173.","journal-title":"Neurosurg Focus"},{"key":"168_CR245","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1089\/neu.2009.1080","volume":"27","author":"BK Kwon","year":"2010","unstructured":"Kwon BK, Stammers AMT, Belanger LM, Bernardo A, Chan D, Bishop CM, Slobogean GP, Zhang H, Umedaly H, Giffin M, Street J, Boyd MC, Paquette SJ, Fisher CG, Dvorak MF. Cerebrospinal Fluid Inflammatory Cytokines and Biomarkers of Injury Severity in Acute Human Spinal Cord Injury. J Neurotrauma. 2010;27:669\u201382. https:\/\/doi.org\/10.1089\/neu.2009.1080.","journal-title":"J Neurotrauma"},{"key":"168_CR246","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1109\/TBME.2006.886617","volume":"54","author":"N Lago","year":"2007","unstructured":"Lago N, Yoshida K, Koch KP, Navarro X. Assessment of biocompatibility of chronically implanted polyimide and platinum intrafascicular electrodes. IEEE Trans Biomed Eng. 2007;54:281\u201390. https:\/\/doi.org\/10.1109\/TBME.2006.886617.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR247","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1001\/jama.2019.18611","volume":"323","author":"DP Lander","year":"2020","unstructured":"Lander DP, Durakovic N, Kallogjeri D, Jiramongkolchai P, Olsen MA, Piccirillo JF, Buchman CA. Incidence of infectious complications following cochlear implantation in children and adults. JAMA. 2020;323:182\u20133. https:\/\/doi.org\/10.1001\/jama.2019.18611.","journal-title":"JAMA"},{"key":"168_CR248","doi-asserted-by":"publisher","first-page":"4169","DOI":"10.1167\/iovs.08-2076","volume":"49","author":"JE Lee","year":"2008","unstructured":"Lee JE, Liang KJ, Fariss RN, Wong WT. Ex vivo dynamic imaging of retinal microglia using time-lapse confocal microscopy. Invest Ophthalmol vis Sci. 2008;49:4169\u201376. https:\/\/doi.org\/10.1167\/iovs.08-2076.","journal-title":"Invest Ophthalmol vis Sci"},{"key":"168_CR249","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1016\/j.snb.2016.06.169","volume":"237","author":"YJ Lee","year":"2016","unstructured":"Lee YJ, Kim HJ, Do SH, Kang JY, Lee SH. Characterization of nerve-cuff electrode interface for biocompatible and chronic stimulating application. Sens Actuators, B Chem. 2016;237:924\u201334. https:\/\/doi.org\/10.1016\/j.snb.2016.06.169.","journal-title":"Sens Actuators, B Chem"},{"key":"168_CR250","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1038\/s41928-021-00631-8","volume":"4","author":"J Lee","year":"2021","unstructured":"Lee J, Leung V, Lee A-H, Huang J, Asbeck P, Mercier PP, Shellhammer S, Larson L, Laiwalla F, Nurmikko A. Neural recording and stimulation using wireless networks of microimplants. Nat Electron. 2021;4:604\u201314. https:\/\/doi.org\/10.1038\/s41928-021-00631-8.","journal-title":"Nat Electron"},{"key":"168_CR251","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1038\/s41467-023-43727-9","volume":"15","author":"K Lee","year":"2024","unstructured":"Lee K, Paulk AC, Ro YG, Cleary DR, Tonsfeldt KJ, Kfir Y, Pezaris JS, Tchoe Y, Lee J, Bourhis AM, Vatsyayan R, Martin JR, Russman SM, Yang JC, Baohan A, Richardson RM, Williams ZM, Fried SI, Hoi Sang U, Raslan AM, Ben-Haim S, Halgren E, Cash SS, Dayeh SA. Flexible, scalable, high channel count stereo-electrode for recording in the human brain. Nat Commun. 2024;15:218. https:\/\/doi.org\/10.1038\/s41467-023-43727-9.","journal-title":"Nat Commun"},{"key":"168_CR252","doi-asserted-by":"publisher","first-page":"119116","DOI":"10.1016\/j.neuroimage.2022.119116","volume":"254","author":"K Lehongre","year":"2022","unstructured":"Lehongre K, Lambrecq V, Whitmarsh S, Frazzini V, Cousyn L, Soleil D, Fernandez-Vidal S, Mathon B, Houot M, Lemar\u00e9chal J-D, Clemenceau S, Hasboun D, Adam C, Navarro V. Long-term deep intracerebral microelectrode recordings in patients with drug-resistant epilepsy: Proposed guidelines based on 10-year experience. Neuroimage. 2022;254:119116. https:\/\/doi.org\/10.1016\/j.neuroimage.2022.119116.","journal-title":"Neuroimage"},{"key":"168_CR253","doi-asserted-by":"publisher","first-page":"035005","DOI":"10.1088\/1741-2552\/ab8f70","volume":"17","author":"D Lemoine","year":"2020","unstructured":"Lemoine D, Simon E, Buc G, Deterre M. In vitro reliability testing and in vivo lifespan estimation of wireless Pixium Vision PRIMA photovoltaic subretinal prostheses suggest prolonged durability and functionality in clinical practice. J Neural Eng. 2020;17:035005. https:\/\/doi.org\/10.1088\/1741-2552\/ab8f70.","journal-title":"J Neural Eng"},{"key":"168_CR254","doi-asserted-by":"publisher","first-page":"046001","DOI":"10.1088\/1741-2560\/6\/4\/046001","volume":"6","author":"SF Lempka","year":"2009","unstructured":"Lempka SF, Miocinovic S, Johnson MD, Vitek JL, McIntyre CC. In vivo impedance spectroscopy of deep brain stimulation electrodes. J Neural Eng. 2009;6:046001. https:\/\/doi.org\/10.1088\/1741-2560\/6\/4\/046001.","journal-title":"J Neural Eng"},{"key":"168_CR255","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1088\/1741-2560\/1\/2\/001","volume":"1","author":"EC Leuthardt","year":"2004","unstructured":"Leuthardt EC, Schalk G, Wolpaw JR, Ojemann JG, Moran DW. A brain-computer interface using electrocorticographic signals in humans. J Neural Eng. 2004;1:63\u201371. https:\/\/doi.org\/10.1088\/1741-2560\/1\/2\/001.","journal-title":"J Neural Eng"},{"key":"168_CR256","doi-asserted-by":"publisher","first-page":"2483","DOI":"10.1016\/j.actbio.2011.02.027","volume":"7","author":"D Lewitus","year":"2011","unstructured":"Lewitus D, Smith KL, Shain W, Kohn J. Ultrafast resorbing polymers for use as carriers for cortical neural probes. Acta Biomater. 2011;7:2483\u201391. https:\/\/doi.org\/10.1016\/j.actbio.2011.02.027.","journal-title":"Acta Biomater"},{"key":"168_CR257","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1111\/epi.13964","volume":"59","author":"MCH Li","year":"2018","unstructured":"Li MCH, Cook MJ. Deep brain stimulation for drug-resistant epilepsy. Epilepsia. 2018;59:273\u201390. https:\/\/doi.org\/10.1111\/epi.13964.","journal-title":"Epilepsia"},{"key":"168_CR258","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1111\/ner.12072","volume":"16","author":"L Liem","year":"2013","unstructured":"Liem L, Russo M, Huygen FJPM, Van Buyten JP, Smet I, Verrills P, Cousins M, Brooker C, Levy R, Deer T, Kramer J. A multicenter, prospective trial to assess the safety and performance of the spinal modulation dorsal root ganglion neurostimulator system in the treatment of chronic pain. Neuromodulation. 2013;16:471\u201382. https:\/\/doi.org\/10.1111\/ner.12072. discussion 482.","journal-title":"Neuromodulation"},{"key":"168_CR259","doi-asserted-by":"publisher","first-page":"1555","DOI":"10.1007\/s00216-008-1970-7","volume":"391","author":"F Lisdat","year":"2008","unstructured":"Lisdat F, Sch\u00e4fer D. The use of electrochemical impedance spectroscopy for biosensing. Anal Bioanal Chem. 2008;391:1555\u201367. https:\/\/doi.org\/10.1007\/s00216-008-1970-7.","journal-title":"Anal Bioanal Chem"},{"key":"168_CR260","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1109\/86.788468","volume":"7","author":"X Liu","year":"1999","unstructured":"Liu X, McCreery DB, Carter RR, Bullara LA, Yuen TG, Agnew WF. Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes. IEEE Trans Rehabil Eng. 1999;7:315\u201326. https:\/\/doi.org\/10.1109\/86.788468.","journal-title":"IEEE Trans Rehabil Eng"},{"key":"168_CR261","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1038\/nnano.2015.115","volume":"10","author":"J Liu","year":"2015","unstructured":"Liu J, Fu T-M, Cheng Z, Hong G, Zhou T, Jin L, Duvvuri M, Jiang Z, Kruskal P, Xie C, Suo Z, Fang Y, Lieber CM. Syringe-injectable electronics. Nat Nanotechnol. 2015;10:629\u201336. https:\/\/doi.org\/10.1038\/nnano.2015.115.","journal-title":"Nat Nanotechnol"},{"key":"168_CR262","unstructured":"LivaNova, Vagus Nerve Stimulation (VNS) therapy for epilepsy | VNS Therapy [WWW Document]. 2023. URL https:\/\/www.livanova.com\/epilepsy-vnstherapy\/en-us. Accessed 10.31.23."},{"key":"168_CR263","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1088\/1741-2560\/3\/1\/007","volume":"3","author":"KA Ludwig","year":"2006","unstructured":"Ludwig KA, Uram JD, Yang J, Martin DC, Kipke DR. Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film. J Neural Eng. 2006;3:59\u201370. https:\/\/doi.org\/10.1088\/1741-2560\/3\/1\/007.","journal-title":"J Neural Eng"},{"key":"168_CR264","doi-asserted-by":"publisher","first-page":"014001","DOI":"10.1088\/1741-2560\/8\/1\/014001","volume":"8","author":"KA Ludwig","year":"2011","unstructured":"Ludwig KA, Langhals NB, Joseph MD, Richardson-Burns SM, Hendricks JL, Kipke DR. Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes. J Neural Eng. 2011;8:014001. https:\/\/doi.org\/10.1088\/1741-2560\/8\/1\/014001.","journal-title":"J Neural Eng"},{"key":"168_CR265","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1007\/s13311-022-01190-2","volume":"19","author":"S Luo","year":"2022","unstructured":"Luo S, Rabbani Q, Crone NE. Brain-computer interface: applications to speech decoding and synthesis to augment communication. Neurotherapeutics. 2022;19:263\u201373. https:\/\/doi.org\/10.1007\/s13311-022-01190-2.","journal-title":"Neurotherapeutics"},{"key":"168_CR266","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1212\/01.wnl.0000134650.91974.1a","volume":"63","author":"KE Lyons","year":"2004","unstructured":"Lyons KE, Wilkinson SB, Overman J, Pahwa R. Surgical and hardware complications of subthalamic stimulation: a series of 160 procedures. Neurology. 2004;63:612\u20136. https:\/\/doi.org\/10.1212\/01.wnl.0000134650.91974.1a.","journal-title":"Neurology"},{"key":"168_CR267","doi-asserted-by":"publisher","unstructured":"Mahajan S, Hermann JK, Bedell HW, Sharkins JA, Chen L, Chen K, Meade SM, Smith CS, Rayyan J, Feng H, Kim Y, Schiefer MA, Taylor DM, Capadona JR, Ereifej ES. Toward standardization of electrophysiology and computational tissue strain in rodent intracortical microelectrode models. Front Bioeng Biotechnol. 2020;8. https:\/\/doi.org\/10.3389\/fbioe.2020.00416.","DOI":"10.3389\/fbioe.2020.00416"},{"key":"168_CR268","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s40708-023-00199-3","volume":"10","author":"B Maiseli","year":"2023","unstructured":"Maiseli B, Abdalla AT, Massawe LV, Mbise M, Mkocha K, Nassor NA, Ismail M, Michael J, Kimambo S. Brain\u2013computer interface: trend, challenges, and threats. Brain Inform. 2023;10:20. https:\/\/doi.org\/10.1186\/s40708-023-00199-3.","journal-title":"Brain Inform"},{"key":"168_CR269","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1109\/TBCAS.2021.3066838","volume":"15","author":"NS Makowski","year":"2021","unstructured":"Makowski NS, Campean A, Lambrecht JM, Buckett JR, Coburn JD, Hart RL, Miller ME, Montague FW, Crish T, Fu MJ, Kilgore KL, Peckham PH, Smith B. Design and testing of stimulation and myoelectric recording modules in an implanted distributed neuroprosthetic system. IEEE Trans Biomed Circuits Syst. 2021;15:281\u201393. https:\/\/doi.org\/10.1109\/TBCAS.2021.3066838.","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"168_CR270","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1007\/BF02368058","volume":"17","author":"MS Malagodi","year":"1989","unstructured":"Malagodi MS, Horch KW, Schoenberg AA. An intrafascicular electrode for recording of action potentials in peripheral nerves. Ann Biomed Eng. 1989;17:397\u2013410. https:\/\/doi.org\/10.1007\/BF02368058.","journal-title":"Ann Biomed Eng"},{"key":"168_CR271","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1016\/s0022-5347(17)61137-6","volume":"107","author":"C Markland","year":"1972","unstructured":"Markland C, Merrill D, Chou S, Bradley W. Sacral nerve root stimulation: a clinical test of detrusor innervation. J Urol. 1972;107:772\u20136. https:\/\/doi.org\/10.1016\/s0022-5347(17)61137-6.","journal-title":"J Urol"},{"key":"168_CR272","first-page":"1","volume":"23","author":"EB Marsolais","year":"1986","unstructured":"Marsolais EB, Kobetic R. Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities. J Rehabil Res Dev. 1986;23:1\u20138.","journal-title":"J Rehabil Res Dev"},{"key":"168_CR273","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1002\/jbm.a.20009","volume":"68","author":"SP Massia","year":"2004","unstructured":"Massia SP, Holecko MM, Ehteshami GR. In vitro assessment of bioactive coatings for neural implant applications. J Biomed Mater Res A. 2004;68:177\u201386. https:\/\/doi.org\/10.1002\/jbm.a.20009.","journal-title":"J Biomed Mater Res A"},{"key":"168_CR274","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1007\/s10544-011-9519-5","volume":"13","author":"PT McCarthy","year":"2011","unstructured":"McCarthy PT, Otto KJ, Rao MP. Robust penetrating microelectrodes for neural interfaces realized by titanium micromachining. Biomed Microdevices. 2011;13:503\u201315. https:\/\/doi.org\/10.1007\/s10544-011-9519-5.","journal-title":"Biomed Microdevices"},{"key":"168_CR275","doi-asserted-by":"publisher","first-page":"7853","DOI":"10.1074\/jbc.RA118.001949","volume":"293","author":"RC McCarthy","year":"2018","unstructured":"McCarthy RC, Sosa JC, Gardeck AM, Baez AS, Lee C-H, Wessling-Resnick M. Inflammation-induced iron transport and metabolism by brain microglia. J Biol Chem. 2018;293:7853\u201363. https:\/\/doi.org\/10.1074\/jbc.RA118.001949.","journal-title":"J Biol Chem"},{"key":"168_CR276","doi-asserted-by":"publisher","first-page":"056003","DOI":"10.1088\/1741-2560\/6\/5\/056003","volume":"6","author":"GC McConnell","year":"2009","unstructured":"McConnell GC, Rees HD, Levey AI, Gutekunst C-A, Gross RE, Bellamkonda RV. Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration. J Neural Eng. 2009;6:056003. https:\/\/doi.org\/10.1088\/1741-2560\/6\/5\/056003.","journal-title":"J Neural Eng"},{"key":"168_CR277","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1109\/10.102812","volume":"37","author":"DB McCreery","year":"1990","unstructured":"McCreery DB, Agnew WF, Yuen TG, Bullara L. Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation. IEEE Trans Biomed Eng. 1990;37:996\u20131001. https:\/\/doi.org\/10.1109\/10.102812.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR278","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1109\/TNSRE.2004.827223","volume":"12","author":"D McCreery","year":"2004","unstructured":"McCreery D, Pikov V, Lossinsky A, Bullara L, Agnew W. Arrays for chronic functional microstimulation of the lumbosacral spinal cord. IEEE Trans Neural Syst Rehabil Eng. 2004;12:195\u2013207. https:\/\/doi.org\/10.1109\/TNSRE.2004.827223.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"168_CR279","doi-asserted-by":"publisher","first-page":"036005","DOI":"10.1088\/1741-2560\/7\/3\/036005","volume":"7","author":"D McCreery","year":"2010","unstructured":"McCreery D, Pikov V, Troyk PR. Neuronal loss due to prolonged controlled-current stimulation with chronically implanted microelectrodes in the cat cerebral cortex. J Neural Eng. 2010;7:036005. https:\/\/doi.org\/10.1088\/1741-2560\/7\/3\/036005.","journal-title":"J Neural Eng"},{"key":"168_CR280","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1016\/j.brs.2021.10.385","volume":"14","author":"D McCreery","year":"2021","unstructured":"McCreery D, Han M, Pikov V, Miller C. Configuring intracortical microelectrode arrays and stimulus parameters to minimize neuron loss during prolonged intracortical electrical stimulation. Brain Stimul. 2021;14:1553\u201362. https:\/\/doi.org\/10.1016\/j.brs.2021.10.385.","journal-title":"Brain Stimul"},{"key":"168_CR281","unstructured":"Medtronic. Spinal cord stimulation systems. 2017."},{"key":"168_CR282","doi-asserted-by":"publisher","unstructured":"Mehta V, Kramer D, Russin J, Liu C, Amar A. Chapter 82 - vagal nerve simulation, in: Krames, E.S., Peckham, P.H., Rezai, A.R. (Eds.), Neuromodulation (Second Edition). Academic Press. 2018:999\u20131009. https:\/\/doi.org\/10.1016\/B978-0-12-805353-9.00082-6.","DOI":"10.1016\/B978-0-12-805353-9.00082-6"},{"key":"168_CR283","doi-asserted-by":"publisher","first-page":"31","DOI":"10.3171\/2018.1.PEDS17476","volume":"22","author":"Y Meng","year":"2018","unstructured":"Meng Y, Voisin MR, Suppiah S, Merali Z, Moghaddamjou A, Alotaibi NM, Manicat-Emo A, Weiss S, Go C, McCoy B, Donner EJ, Rutka JT. Risk factors for surgical site infection after intracranial electroencephalography monitoring for epilepsy in the pediatric population. J Neurosurg Pediatr. 2018;22:31\u20136. https:\/\/doi.org\/10.3171\/2018.1.PEDS17476.","journal-title":"J Neurosurg Pediatr"},{"key":"168_CR284","doi-asserted-by":"publisher","unstructured":"Merrill DR. The electrochemistry of charge injection at the electrode\/tissue interface, in: Zhou, D., Greenbaum, E. (Eds.), Implantable neural prostheses 2: techniques and engineering approaches, biological and medical physics, biomedical engineering. Springer, New York, NY. 2010:85\u2013138. https:\/\/doi.org\/10.1007\/978-0-387-98120-8_4.","DOI":"10.1007\/978-0-387-98120-8_4"},{"key":"168_CR285","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/j.cossms.2014.07.002","volume":"18","author":"DR Merrill","year":"2014","unstructured":"Merrill DR. Materials considerations of implantable neuroengineering devices for clinical use. Curr Opin Solid State Mater Sci, Neuroeng Mat. 2014;18:329\u201336. https:\/\/doi.org\/10.1016\/j.cossms.2014.07.002.","journal-title":"Curr Opin Solid State Mater Sci, Neuroeng Mat"},{"key":"168_CR286","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.jneumeth.2004.10.020","volume":"141","author":"DR Merrill","year":"2005","unstructured":"Merrill DR, Bikson M, Jefferys JGR. Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J Neurosci Methods. 2005;141:171\u201398. https:\/\/doi.org\/10.1016\/j.jneumeth.2004.10.020.","journal-title":"J Neurosci Methods"},{"key":"168_CR287","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1126\/science.1260318","volume":"347","author":"IR Minev","year":"2015","unstructured":"Minev IR, Musienko P, Hirsch A, Barraud Q, Wenger N, Moraud EM, Gandar J, Capogrosso M, Milekovic T, Asboth L, Torres RF, Vachicouras N, Liu Q, Pavlova N, Duis S, Larmagnac A, V\u00f6r\u00f6s J, Micera S, Suo Z, Courtine G, Lacour SP. Electronic dura mater for long-term multimodal neural interfaces. Science. 2015;347:159\u201363. https:\/\/doi.org\/10.1126\/science.1260318.","journal-title":"Science"},{"key":"168_CR288","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/2024.2.SPINE23757","volume":"41","author":"S Mirkiani","year":"2024","unstructured":"Mirkiani S, O\u2019Sullivan CL, Roszko DA, Faridi P, Hu DS, Everaert DG, Toossi A, Kang R, Fang T, Tyreman N, Dalrymple AN, Robinson K, Uwiera RRE, Shah H, Fox R, Konrad PE, Mushahwar VK. Safety of mapping the motor networks in the spinal cord using penetrating microelectrodes in Yucatan minipigs. J Neurosurg Spine. 2024;41:1\u201313. https:\/\/doi.org\/10.3171\/2024.2.SPINE23757.","journal-title":"J Neurosurg Spine"},{"key":"168_CR289","doi-asserted-by":"publisher","unstructured":"Mishra LN, Kulkarni G, Gadgil M. A novel current steering method for targeted spinal cord stimulation. Front Pain Res. 2020;4. https:\/\/doi.org\/10.3389\/fpain.2023.1028368.","DOI":"10.3389\/fpain.2023.1028368"},{"key":"168_CR290","doi-asserted-by":"publisher","unstructured":"Mitchell P, Lee SCM, Yoo PE, Morokoff A, Sharma RP, Williams DL, MacIsaac C, Howard ME, Irving L, Vrljic I, Williams C, Bush S, Balabanski AH, Drummond KJ, Desmond P, Weber D, Denison T, Mathers S, O\u2019Brien TJ, Mocco J, Grayden DB, Liebeskind DS, Opie NL, Oxley TJ, Campbell BCV. Assessment of safety of a fully implanted endovascular brain-computer interface for severe paralysis in 4 patients: the Stentrode With Thought-Controlled Digital Switch (SWITCH) Study. JAMA Neurol. 2023. https:\/\/doi.org\/10.1001\/jamaneurol.2022.4847.","DOI":"10.1001\/jamaneurol.2022.4847"},{"key":"168_CR291","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.parkreldis.2003.11.001","volume":"10","author":"AA Mohit","year":"2004","unstructured":"Mohit AA, Samii A, Slimp JC, Grady MS, Goodkin R. Mechanical failure of the electrode wire in deep brain stimulation. Parkinsonism Relat Disord. 2004;10:153\u20136. https:\/\/doi.org\/10.1016\/j.parkreldis.2003.11.001.","journal-title":"Parkinsonism Relat Disord"},{"key":"168_CR292","doi-asserted-by":"publisher","unstructured":"Moman RN, Peterson AA, Maher DP, Eli I, Hagedorn JM, Bendel MA, Gerberi D, Murad MH, Hooten WM. Infectious complications of dorsal root ganglion stimulation: a systematic review and pooled analysis of incidence. Neuromodulation. 2021. https:\/\/doi.org\/10.1111\/ner.13473.","DOI":"10.1111\/ner.13473"},{"key":"168_CR293","doi-asserted-by":"publisher","first-page":"E377","DOI":"10.36076\/ppj.2018.4.E377","volume":"21","author":"MH Morgalla","year":"2018","unstructured":"Morgalla MH, Fortunato M, Lepski G, Chander BS. Dorsal Root Ganglion Stimulation (DRGS) for the treatment of chronic neuropathic pain: a single-center study with long-term prospective results in 62 cases. Pain Physician. 2018;21:E377\u201387.","journal-title":"Pain Physician"},{"key":"168_CR294","doi-asserted-by":"publisher","first-page":"e0183711","DOI":"10.1371\/journal.pone.0183711","volume":"12","author":"T Morishita","year":"2017","unstructured":"Morishita T, Hilliard JD, Okun MS, Neal D, Nestor KA, Peace D, Hozouri AA, Davidson MR, Bova FJ, Sporrer JM, Oyama G, Foote KD. Postoperative lead migration in deep brain stimulation surgery: incidence, risk factors, and clinical impact. PLoS ONE. 2017;12:e0183711. https:\/\/doi.org\/10.1371\/journal.pone.0183711.","journal-title":"PLoS ONE"},{"key":"168_CR295","doi-asserted-by":"publisher","first-page":"2755","DOI":"10.1093\/brain\/awh292","volume":"127","author":"J Moss","year":"2004","unstructured":"Moss J, Ryder T, Aziz TZ, Graeber MB, Bain PG. Electron microscopy of tissue adherent to explanted electrodes in dystonia and Parkinson\u2019s disease. Brain. 2004;127:2755\u201363. https:\/\/doi.org\/10.1093\/brain\/awh292.","journal-title":"Brain"},{"key":"168_CR296","doi-asserted-by":"publisher","first-page":"6325","DOI":"10.1007\/s00405-024-08855-y","volume":"281","author":"BE Mostafa","year":"2024","unstructured":"Mostafa BE, El Fiky L. Complications of cochlear implantation: a decade\u2019s experience. Eur Arch Otorhinolaryngol. 2024;281:6325\u201331. https:\/\/doi.org\/10.1007\/s00405-024-08855-y.","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"168_CR297","doi-asserted-by":"publisher","first-page":"1762","DOI":"10.3390\/ma2041762","volume":"2","author":"KA Moxon","year":"2009","unstructured":"Moxon KA, Hallman S, Sundarakrishnan A, Wheatley M, Nissanov J, Barbee KA. Long-term recordings of multiple, single-neurons for clinical applications: the emerging role of the bioactive microelectrode. Materials (Basel). 2009;2:1762\u201394. https:\/\/doi.org\/10.3390\/ma2041762.","journal-title":"Materials (Basel)"},{"key":"168_CR298","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/j.ophtha.2018.11.010","volume":"126","author":"MMK Muqit","year":"2019","unstructured":"Muqit MMK, Velikay-Parel M, Weber M, Dupeyron G, Audemard D, Corcostegui B, Sahel J, Le Mer Y. Six-month safety and efficacy of the intelligent retinal implant system II device in retinitis pigmentosa. Ophthalmology. 2019;126:637\u20139. https:\/\/doi.org\/10.1016\/j.ophtha.2018.11.010.","journal-title":"Ophthalmology"},{"key":"168_CR299","doi-asserted-by":"publisher","unstructured":"Musk E, Neuralink. An integrated brain-machine interface platform with thousands of channels. J Med Internet Res. 2019;21:e16194. https:\/\/doi.org\/10.2196\/16194.","DOI":"10.2196\/16194"},{"key":"168_CR300","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1177\/000348940111000914","volume":"110","author":"JB Nadol","year":"2001","unstructured":"Nadol JB, Shiao JY, Burgess BJ, Ketten DR, Eddington DK, Gantz BJ, Kos I, Montandon P, Coker NJ, Roland JT, Shallop JK. Histopathology of cochlear implants in humans. Ann Otol Rhinol Laryngol. 2001;110:883\u201391. https:\/\/doi.org\/10.1177\/000348940111000914.","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"168_CR301","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.heares.2014.09.007","volume":"318","author":"JB Nadol","year":"2014","unstructured":"Nadol JB, O\u2019Malley JT, Burgess BJ, Galler D. Cellular immunologic responses to cochlear implantation in the human. Hear Res. 2014;318:11\u20137. https:\/\/doi.org\/10.1016\/j.heares.2014.09.007.","journal-title":"Hear Res"},{"key":"168_CR302","doi-asserted-by":"publisher","unstructured":"Nagarkar K, Hou X, Stoffel N, Davis E, Ashe J, Borton D. Micro-hermetic packaging technology for active implantable neural interfaces, in: 2017 IEEE 67th Electronic Components and Technology Conference (ECTC). Presented at the 2017 IEEE 67th Electronic Components and Technology Conference (ECTC). 2017:218\u2013223. https:\/\/doi.org\/10.1109\/ECTC.2017.340.","DOI":"10.1109\/ECTC.2017.340"},{"key":"168_CR303","doi-asserted-by":"publisher","first-page":"eabn4732","DOI":"10.1126\/science.abn4732","volume":"382","author":"V Nair","year":"2023","unstructured":"Nair V, Dalrymple AN, Yu Z, Balakrishnan G, Bettinger CJ, Weber DJ, Yang K, Robinson JT. Miniature battery-free bioelectronics. Science. 2023;382:eabn4732. https:\/\/doi.org\/10.1126\/science.abn4732.","journal-title":"Science"},{"key":"168_CR304","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1038\/s41551-023-01153-8","volume":"8","author":"AC Nanivadekar","year":"2023","unstructured":"Nanivadekar AC, Bose R, Petersen BA, Okorokova EV, Sarma D, Madonna TJ, Barra B, Farooqui J, Dalrymple AN, Levy I, Helm ER, Miele VJ, Boninger ML, Capogrosso M, Bensmaia SJ, Weber DJ, Fisher LE. Restoration of sensory feedback from the foot and reduction of phantom limb pain via closed-loop spinal cord stimulation. Nat Biomed Eng. 2023;8:992\u20131003. https:\/\/doi.org\/10.1038\/s41551-023-01153-8.","journal-title":"Nat Biomed Eng"},{"key":"168_CR305","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1109\/10.8670","volume":"35","author":"GG Naples","year":"1988","unstructured":"Naples GG, Mortimer JT, Scheiner A, Sweeney JD. A spiral nerve cuff electrode for peripheral nerve stimulation. IEEE Trans Biomed Eng. 1988;35:905\u201316. https:\/\/doi.org\/10.1109\/10.8670.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR306","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1001\/archsurg.1972.04180020075015","volume":"104","author":"BS Nashold","year":"1972","unstructured":"Nashold BS, Friedman H, Glenn JF, Grimes JH, Barry WF, Avery R. Electromicturition in paraplegia. Implantation of a spinal neuroprosthesis. Arch Surg. 1972;104:195\u2013202. https:\/\/doi.org\/10.1001\/archsurg.1972.04180020075015.","journal-title":"Arch Surg"},{"key":"168_CR307","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1159\/000102205","volume":"44","author":"BS Nashold","year":"1981","unstructured":"Nashold BS, Friedman H, Grimes J. Electrical stimulation of the conus medullaris to control the bladder in the paraplegic patient. A 10-year review. Appl Neurophysiol. 1981;44:225\u201332. https:\/\/doi.org\/10.1159\/000102205.","journal-title":"Appl Neurophysiol"},{"key":"168_CR308","doi-asserted-by":"publisher","first-page":"e97182","DOI":"10.1371\/journal.pone.0097182","volume":"9","author":"DAX Nayagam","year":"2014","unstructured":"Nayagam DAX, Williams RA, Allen PJ, Shivdasani MN, Luu CD, Salinas-LaRosa CM, Finch S, Ayton LN, Saunders AL, McPhedran M, McGowan C, Villalobos J, Fallon JB, Wise AK, Yeoh J, Xu J, Feng H, Millard R, McWade M, Thien PC, Williams CE, Shepherd RK. Chronic electrical stimulation with a suprachoroidal retinal prosthesis: a preclinical safety and efficacy study. PLoS ONE. 2014;9:e97182. https:\/\/doi.org\/10.1371\/journal.pone.0097182.","journal-title":"PLoS ONE"},{"key":"168_CR309","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1152\/jn.00877.2016","volume":"118","author":"MJ Nelson","year":"2017","unstructured":"Nelson MJ, Valtcheva S, Venance L. Magnitude and behavior of cross-talk effects in multichannel electrophysiology experiments. J Neurophysiol. 2017;118:574\u201394. https:\/\/doi.org\/10.1152\/jn.00877.2016.","journal-title":"J Neurophysiol"},{"key":"168_CR310","doi-asserted-by":"publisher","first-page":"116","DOI":"10.3109\/00016489.2012.723824","volume":"133","author":"Y Nguyen","year":"2013","unstructured":"Nguyen Y, Mosnier I, Borel S, Ambert-Dahan E, Bouccara D, Bozorg-Grayeli A, Ferrary E, Sterkers O. Evolution of electrode array diameter for hearing preservation in cochlear implantation. Acta Otolaryngol. 2013;133:116\u201322. https:\/\/doi.org\/10.3109\/00016489.2012.723824.","journal-title":"Acta Otolaryngol"},{"key":"168_CR311","doi-asserted-by":"publisher","first-page":"911","DOI":"10.3389\/fnins.2019.00911","volume":"13","author":"CM Noller","year":"2019","unstructured":"Noller CM, Levine YA, Urakov TM, Aronson JP, Nash MS. Vagus nerve stimulation in rodent models: an overview of technical considerations. Front Neurosci. 2019;13:911. https:\/\/doi.org\/10.3389\/fnins.2019.00911.","journal-title":"Front Neurosci"},{"key":"168_CR312","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1002\/jbm.b.31733","volume":"95","author":"EA Nunamaker","year":"2010","unstructured":"Nunamaker EA, Kipke DR. An alginate hydrogel dura mater replacement for use with intracortical electrodes. J Biomed Mater Res B Appl Biomater. 2010;95:421\u20139. https:\/\/doi.org\/10.1002\/jbm.b.31733.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"168_CR313","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1109\/TBME.2017.2768442","volume":"65","author":"ES Nurse","year":"2018","unstructured":"Nurse ES, John SE, Freestone DR, Oxley TJ, Ung H, Berkovic SF, O\u2019Brien TJ, Cook MJ, Grayden DB. Consistency of long-term subdural electrocorticography in humans. IEEE Trans Biomed Eng. 2018;65:344\u201352. https:\/\/doi.org\/10.1109\/TBME.2017.2768442.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR314","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1097\/MAO.0000000000001454","volume":"38","author":"JT O\u2019Malley","year":"2017","unstructured":"O\u2019Malley JT, Burgess BJ, Galler D, Nadol JB. Foreign body response to silicone in cochlear implant electrodes in the human. Otol Neurotol. 2017;38:970\u20137. https:\/\/doi.org\/10.1097\/MAO.0000000000001454.","journal-title":"Otol Neurotol"},{"key":"168_CR315","doi-asserted-by":"publisher","first-page":"066033","DOI":"10.1088\/1741-2552\/aae398","volume":"15","author":"EV Okorokova","year":"2018","unstructured":"Okorokova EV, He Q, Bensmaia SJ. Biomimetic encoding model for restoring touch in bionic hands through a nerve interface. J Neural Eng. 2018;15:066033. https:\/\/doi.org\/10.1088\/1741-2552\/aae398.","journal-title":"J Neural Eng"},{"key":"168_CR316","doi-asserted-by":"publisher","first-page":"1258190","DOI":"10.3389\/fnagi.2023.1258190","volume":"15","author":"MC Olson","year":"2023","unstructured":"Olson MC, Shill H, Ponce F, Aslam S. Deep brain stimulation in PD: risk of complications, morbidity, and hospitalizations: a systematic review. Front Aging Neurosci. 2023;15:1258190. https:\/\/doi.org\/10.3389\/fnagi.2023.1258190.","journal-title":"Front Aging Neurosci"},{"key":"168_CR317","doi-asserted-by":"publisher","first-page":"7802","DOI":"10.1167\/iovs.12-10600","volume":"53","author":"NL Opie","year":"2012","unstructured":"Opie NL, Greferath U, Vessey KA, Burkitt AN, Meffin H, Grayden DB, Fletcher EL. Retinal prosthesis safety: alterations in microglia morphology due to thermal damage and retinal implant contact. Invest Ophthalmol vis Sci. 2012;53:7802\u201312. https:\/\/doi.org\/10.1167\/iovs.12-10600.","journal-title":"Invest Ophthalmol vis Sci"},{"key":"168_CR318","doi-asserted-by":"publisher","first-page":"046020","DOI":"10.1088\/1741-2560\/13\/4\/046020","volume":"13","author":"NL Opie","year":"2016","unstructured":"Opie NL, John SE, Rind GS, Ronayne SM, Grayden DB, Burkitt AN, May CN, O\u2019Brien TJ, Oxley TJ. Chronic impedance spectroscopy of an endovascular stent-electrode array. J Neural Eng. 2016;13:046020. https:\/\/doi.org\/10.1088\/1741-2560\/13\/4\/046020.","journal-title":"J Neural Eng"},{"key":"168_CR319","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1109\/TBME.2016.2552226","volume":"64","author":"NL Opie","year":"2017","unstructured":"Opie NL, van der Nagel NR, John SE, Vessey K, Rind GS, Ronayne SM, Fletcher EL, May CN, O\u2019Brien TJ, Oxley TJ. Micro-CT and Histological Evaluation of an Neural Interface Implanted Within a Blood Vessel. IEEE Trans Biomed Eng. 2017;64:928\u201334. https:\/\/doi.org\/10.1109\/TBME.2016.2552226.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR320","doi-asserted-by":"publisher","unstructured":"Opie NL, John SE, Rind GS, Ronayne SM, May CN, Grayden DB, Oxley TJ. Effect of implant duration, anatomical location and electrode orientation on bandwidth recorded with a chronically implanted endovascular stent-electrode array, in: 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Presented at the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 2018:1074\u20131077. https:\/\/doi.org\/10.1109\/EMBC.2018.8512385.","DOI":"10.1109\/EMBC.2018.8512385"},{"key":"168_CR321","doi-asserted-by":"publisher","first-page":"101428","DOI":"10.1016\/j.bjorl.2024.101428","volume":"90","author":"VR Orlando","year":"2024","unstructured":"Orlando VR, Cruz OLM. Postoperative complications in cochlear implant surgery and their possible risk factors. Braz J Otorhinolaryngol. 2024;90:101428. https:\/\/doi.org\/10.1016\/j.bjorl.2024.101428.","journal-title":"Braz J Otorhinolaryngol"},{"key":"168_CR322","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1038\/nbt.3428","volume":"34","author":"TJ Oxley","year":"2016","unstructured":"Oxley TJ, Opie NL, John SE, Rind GS, Ronayne SM, Wheeler TL, Judy JW, McDonald AJ, Dornom A, Lovell TJH, Steward C, Garrett DJ, Moffat BA, Lui EH, Yassi N, Campbell BCV, Wong YT, Fox KE, Nurse ES, Bennett IE, Bauquier SH, Liyanage KA, van der Nagel NR, Perucca P, Ahnood A, Gill KP, Yan B, Churilov L, French CR, Desmond PM, Horne MK, Kiers L, Prawer S, Davis SM, Burkitt AN, Mitchell PJ, Grayden DB, May CN, O\u2019Brien TJ. Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity. Nat Biotechnol. 2016;34:320\u20137. https:\/\/doi.org\/10.1038\/nbt.3428.","journal-title":"Nat Biotechnol"},{"key":"168_CR323","doi-asserted-by":"publisher","unstructured":"Oxley TJ, Yoo PE, Rind GS, Ronayne SM, Lee CMS, Bird C, Hampshire V, Sharma RP, Morokoff A, Williams DL, MacIsaac C, Howard ME, Irving L, Vrljic I, Williams C, John SE, Weissenborn F, Dazenko M, Balabanski AH, Friedenberg D, Burkitt AN, Wong YT, Drummond KJ, Desmond P, Weber D, Denison T, Hochberg LR, Mathers S, O\u2019Brien TJ, May CN, Mocco J, Grayden DB, Campbell BCV, Mitchell P, Opie NL. Motor neuroprosthesis implanted with neurointerventional surgery improves capacity for activities of daily living tasks in severe paralysis: first in-human experience. J NeuroInterv Surg. 2020. https:\/\/doi.org\/10.1136\/neurintsurg-2020-016862.","DOI":"10.1136\/neurintsurg-2020-016862"},{"key":"168_CR324","doi-asserted-by":"publisher","first-page":"352","DOI":"10.3389\/fnhum.2018.00352","volume":"12","author":"DM Page","year":"2018","unstructured":"Page DM, George JA, Kluger DT, Duncan C, Wendelken S, Davis T, Hutchinson DT, Clark GA. Motor control and sensory feedback enhance prosthesis embodiment and reduce phantom pain after long-term hand amputation. Fron Hum Neurosci. 2018;12:352.\u00a0https:\/\/doi.org\/10.3389\/fnhum.2018.00352.","journal-title":"Fron Hum Neurosci"},{"key":"168_CR325","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1038\/nn.4510","volume":"20","author":"S Park","year":"2017","unstructured":"Park S, Guo Y, Jia X, Choe HK, Grena B, Kang J, Park J, Lu C, Canales A, Chen R, Yim YS, Choi GB, Fink Y, Anikeeva P. One-step optogenetics with multifunctional flexible polymer fibers. Nat Neurosci. 2017;20:612\u20139. https:\/\/doi.org\/10.1038\/nn.4510.","journal-title":"Nat Neurosci"},{"key":"168_CR326","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1109\/RBME.2013.2294796","volume":"7","author":"R Pashaie","year":"2014","unstructured":"Pashaie R, Anikeeva P, Lee JH, Prakash R, Yizhar O, Prigge M, Chander D, Richner TJ, Williams J. Optogenetic brain interfaces. IEEE Rev Biomed Eng. 2014;7:3\u201330. https:\/\/doi.org\/10.1109\/RBME.2013.2294796.","journal-title":"IEEE Rev Biomed Eng"},{"key":"168_CR327","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1038\/s41587-019-0234-8","volume":"37","author":"SR Patel","year":"2019","unstructured":"Patel SR, Lieber CM. Precision electronic medicine in the brain. Nat Biotechnol. 2019;37:1007\u201312. https:\/\/doi.org\/10.1038\/s41587-019-0234-8.","journal-title":"Nat Biotechnol"},{"key":"168_CR328","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1016\/j.jneumeth.2011.03.012","volume":"198","author":"E Patrick","year":"2011","unstructured":"Patrick E, Orazem ME, Sanchez JC, Nishida T. Corrosion of tungsten microelectrodes used in neural recording applications. J Neurosci Methods. 2011;198:158\u201371. https:\/\/doi.org\/10.1016\/j.jneumeth.2011.03.012.","journal-title":"J Neurosci Methods"},{"key":"168_CR329","doi-asserted-by":"publisher","first-page":"235","DOI":"10.2217\/bem-2018-0011","volume":"1","author":"SC Payne","year":"2018","unstructured":"Payne SC, Burns O, Stebbing M, Thomas R, de Silva A, Sedo A, Weissenborn F, Hyakumura T, Huynh M, May CN, Williams RA, Furness JB, Fallon JB, Shepherd RK. Vagus nerve stimulation to treat inflammatory bowel disease: a chronic, preclinical safety study in sheep. Bioelectron Med. 2018;1:235\u201350. https:\/\/doi.org\/10.2217\/bem-2018-0011.","journal-title":"Bioelectron Med"},{"key":"168_CR330","doi-asserted-by":"publisher","first-page":"418","DOI":"10.3389\/fnins.2019.00418","volume":"13","author":"SC Payne","year":"2019","unstructured":"Payne SC, Furness JB, Burns O, Sedo A, Hyakumura T, Shepherd RK, Fallon JB. Anti-inflammatory effects of abdominal vagus nerve stimulation on experimental intestinal inflammation. Front Neurosci. 2019;13:418. https:\/\/doi.org\/10.3389\/fnins.2019.00418.","journal-title":"Front Neurosci"},{"key":"168_CR331","doi-asserted-by":"publisher","unstructured":"Payne SC, Wiedmann NM, Eiber CD, Wong AW, Senn P, Osborne PB, Keast JR, Fallon JB. Recording of electrically evoked neural activity and bladder pressure responses in awake rats chronically implanted with a pelvic nerve array. Front Neurosci. 2020;14:619275.\u00a0https:\/\/doi.org\/10.3389\/fnins.2020.619275.","DOI":"10.3389\/fnins.2020.619275"},{"key":"168_CR332","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1053\/apmr.2001.25910","volume":"82","author":"PH Peckham","year":"2001","unstructured":"Peckham PH, Keith MW, Kilgore KL, Grill JH, Wuolle KS, Thrope GB, Gorman P, Hobby J, Mulcahey MJ, Carroll S, Hentz VR, Wiegner A. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study. Arch Phys Med Rehabil. 2001;82:1380\u20138. https:\/\/doi.org\/10.1053\/apmr.2001.25910.","journal-title":"Arch Phys Med Rehabil"},{"key":"168_CR333","doi-asserted-by":"publisher","first-page":"066014","DOI":"10.1088\/1741-2552\/aa814d","volume":"14","author":"AE Pena","year":"2017","unstructured":"Pena AE, Kuntaegowdanahalli SS, Abbas JJ, Patrick J, Horch KW, Jung R. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes. J Neural Eng. 2017;14:066014. https:\/\/doi.org\/10.1088\/1741-2552\/aa814d.","journal-title":"J Neural Eng"},{"key":"168_CR334","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1159\/000343202","volume":"91","author":"J Pepper","year":"2013","unstructured":"Pepper J, Zrinzo L, Mirza B, Foltynie T, Limousin P, Hariz M. The risk of hardware infection in deep brain stimulation surgery is greater at impulse generator replacement than at the primary procedure. Stereotact Funct Neurosurg. 2013;91:56\u201365. https:\/\/doi.org\/10.1159\/000343202.","journal-title":"Stereotact Funct Neurosurg"},{"key":"168_CR335","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1113\/jphysiol.2004.061804","volume":"557","author":"J Phillips","year":"2004","unstructured":"Phillips J, Smit X, De Zoysa N, Afoke A, Brown R. Peripheral nerves in the rat exhibit localized heterogeneity of tensile properties during limb movement. J Physiol. 2004;557:879\u201387. https:\/\/doi.org\/10.1113\/jphysiol.2004.061804.","journal-title":"J Physiol"},{"key":"168_CR336","doi-asserted-by":"crossref","unstructured":"Pinter MM, Gerstenbrand F, Dimitrijevic MR. Epidural electrical stimulation of posterior structures of the human lumbosacral cord: 3. Control of Spasticity. Spinal Cord. 2000;38:524\u201331.","DOI":"10.1038\/sj.sc.3101040"},{"key":"168_CR337","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jneumeth.2005.08.015","volume":"148","author":"VS Polikov","year":"2005","unstructured":"Polikov VS, Tresco PA, Reichert WM. Response of brain tissue to chronically implanted neural electrodes. J Neurosci Methods. 2005;148:1\u201318. https:\/\/doi.org\/10.1016\/j.jneumeth.2005.08.015.","journal-title":"J Neurosci Methods"},{"key":"168_CR338","doi-asserted-by":"publisher","first-page":"2248","DOI":"10.1039\/C4TB00125G","volume":"2","author":"KA Potter-Baker","year":"2014","unstructured":"Potter-Baker KA, Nguyen JK, Kovach KM, Gitomer MM, Srail TW, Stewart WG, Skousen JL, Capadona JR. Development of superoxide dismutase mimetic surfaces to reduce accumulation of reactive oxygen species for neural interfacing applications. J Mater Chem B. 2014;2:2248\u201358. https:\/\/doi.org\/10.1039\/C4TB00125G.","journal-title":"J Mater Chem B"},{"key":"168_CR339","doi-asserted-by":"publisher","unstructured":"Powell MP, Hou X, Galligan C, Ashe J, Borton DA. Toward multi-area distributed network of implanted neural interrogators, in: Biosensing and Nanomedicine X. Presented at the Biosensing and Nanomedicine X, International Society for Optics and Photonics, 2017:103520H. https:\/\/doi.org\/10.1117\/12.2276046.","DOI":"10.1117\/12.2276046"},{"key":"168_CR340","doi-asserted-by":"publisher","unstructured":"Powell MP, Verma N, Sorensen E, Carranza E, Boos A, Fields D, Roy S, Ensel S, Barra B, Balzer J, Goldsmith J, Friedlander RM, Wittenberg G, Fisher LE, Krakauer JW, Gerszten PC, Pirondini E, Weber DJ, Capogrosso M. Epidural stimulation of the cervical spinal cord improves voluntary motor control in post-stroke upper limb paresis. 2022. https:\/\/doi.org\/10.1101\/2022.04.11.22273635.","DOI":"10.1101\/2022.04.11.22273635"},{"key":"168_CR341","doi-asserted-by":"publisher","first-page":"e596","DOI":"10.1016\/j.wneu.2022.12.071","volume":"171","author":"T Prabhala","year":"2023","unstructured":"Prabhala T, Figueroa F, Harland T, Nabage MN, Pilitsis JG. The use of salvage procedures for wound complications in neuromodulation. World Neurosurgery. 2023;171:e596\u2013604. https:\/\/doi.org\/10.1016\/j.wneu.2022.12.071.","journal-title":"World Neurosurgery"},{"key":"168_CR342","doi-asserted-by":"publisher","first-page":"056015","DOI":"10.1088\/1741-2560\/9\/5\/056015","volume":"9","author":"A Prasad","year":"2012","unstructured":"Prasad A, Xue Q-S, Sankar V, Nishida T, Shaw G, Streit WJ, Sanchez JC. Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants. J Neural Eng. 2012;9:056015. https:\/\/doi.org\/10.1088\/1741-2560\/9\/5\/056015.","journal-title":"J Neural Eng"},{"key":"168_CR343","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3389\/fneng.2014.00002","volume":"7","author":"A Prasad","year":"2014","unstructured":"Prasad A, Xue Q-S, Dieme R, Sankar V, Mayrand RC, Nishida T, Streit WJ, Sanchez JC. Abiotic-biotic characterization of Pt\/Ir microelectrode arrays in chronic implants. Front Neuroeng. 2014;7:2. https:\/\/doi.org\/10.3389\/fneng.2014.00002.","journal-title":"Front Neuroeng"},{"key":"168_CR344","doi-asserted-by":"publisher","first-page":"2233","DOI":"10.1016\/j.actbio.2012.03.001","volume":"8","author":"L Rao","year":"2012","unstructured":"Rao L, Zhou H, Li T, Li C, Duan YY. Polyethylene glycol-containing polyurethane hydrogel coatings for improving the biocompatibility of neural electrodes. Acta Biomater. 2012;8:2233\u201342. https:\/\/doi.org\/10.1016\/j.actbio.2012.03.001.","journal-title":"Acta Biomater"},{"key":"168_CR345","doi-asserted-by":"publisher","first-page":"787","DOI":"10.2174\/1570159X17666190409142555","volume":"17","author":"C Rapinesi","year":"2019","unstructured":"Rapinesi C, Kotzalidis GD, Ferracuti S, Sani G, Girardi P, Del Casale A. Brain stimulation in Obsessive-Compulsive Disorder (OCD): a systematic review. Curr Neuropharmacol. 2019;17:787\u2013807. https:\/\/doi.org\/10.2174\/1570159X17666190409142555.","journal-title":"Curr Neuropharmacol"},{"key":"168_CR346","doi-asserted-by":"publisher","unstructured":"Raslan AM, McCartney S, Burchiel KJ. Management of chronic severe pain: spinal neuromodulatory and neuroablative approaches. Acta Neurochir Suppl. 2007;97:33\u201341.\u00a0https:\/\/doi.org\/10.1007\/978-3-211-33079-1_4.","DOI":"10.1007\/978-3-211-33079-1_4"},{"key":"168_CR347","doi-asserted-by":"publisher","first-page":"222ra19\u2013222ra19","DOI":"10.1126\/scitranslmed.3006820","volume":"6","author":"S Raspopovic","year":"2014","unstructured":"Raspopovic S, Capogrosso M, Petrini FM, Bonizzato M, Rigosa J, Di Pino G, Carpaneto J, Controzzi M, Boretius T, Fernandez E, Granata G, Oddo CM, Citi L, Ciancio AL, Cipriani C, Carrozza MC, Jensen W, Guglielmelli E, Stieglitz T, Rossini PM, Micera S. Restoring natural sensory feedback in real-time bidirectional hand prostheses. Sci Transl Med. 2014;6:222ra19-222ra19. https:\/\/doi.org\/10.1126\/scitranslmed.3006820.","journal-title":"Sci Transl Med"},{"key":"168_CR348","doi-asserted-by":"publisher","unstructured":"Rastogi A, Willett FR, Abreu J, Crowder DC, Murphy BA, Memberg WD, Vargas-Irwin CE, Miller JP, Sweet J, Walter BL, Rezaii PG, Stavisky SD, Hochberg LR, Shenoy KV, Henderson JM, Kirsch RF, Ajiboye AB. The neural representation of force across grasp types in motor cortex of humans with Tetraplegia. eNeuro.\u00a02021;8:ENEURO.0231\u201320.2020. https:\/\/doi.org\/10.1523\/ENEURO.0231-20.2020.","DOI":"10.1523\/ENEURO.0231-20.2020"},{"key":"168_CR349","doi-asserted-by":"publisher","first-page":"8049","DOI":"10.1016\/j.biomaterials.2014.05.084","volume":"35","author":"M Ravikumar","year":"2014","unstructured":"Ravikumar M, Sunil S, Black J, Barkauskas DS, Haung AY, Miller RH, Selkirk SM, Capadona JR. The roles of blood-derived macrophages and resident microglia in the neuroinflammatory response to implanted intracortical microelectrodes. Biomaterials. 2014;35:8049\u201364. https:\/\/doi.org\/10.1016\/j.biomaterials.2014.05.084.","journal-title":"Biomaterials"},{"key":"168_CR350","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1089\/neu.1996.13.223","volume":"13","author":"RF Regan","year":"1996","unstructured":"Regan RF, Panter SS. Hemoglobin potentiates excitotoxic injury in cortical cell culture. J Neurotrauma. 1996;13:223\u201331. https:\/\/doi.org\/10.1089\/neu.1996.13.223.","journal-title":"J Neurotrauma"},{"key":"168_CR351","first-page":"153","volume":"9","author":"RR Richardson","year":"1978","unstructured":"Richardson RR, McLone DG. Percutaneous epidural neurostimulation for paraplegic spasticity. Surg Neurol. 1978;9:153\u20135.","journal-title":"Surg Neurol"},{"key":"168_CR352","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1109\/86.313150","volume":"2","author":"NJM Rijkhoff","year":"1994","unstructured":"Rijkhoff NJM, Koldewijn EL, van Kerrebroeck PEV, Debruyne FMJ, Wijkstra H. Acute animal studies on the use of an anodal block to reduce urethral resistance in sacral root stimulation. IEEE Trans Rehabil Eng. 1994;2:92\u20139. https:\/\/doi.org\/10.1109\/86.313150.","journal-title":"IEEE Trans Rehabil Eng"},{"key":"168_CR353","doi-asserted-by":"publisher","first-page":"1504","DOI":"10.1016\/S0022-5347(01)65032-8","volume":"157","author":"NJ Rijkhoff","year":"1997","unstructured":"Rijkhoff NJ, Wijkstra H, van Kerrebroeck PE, Debruyne FM. Selective detrusor activation by electrical sacral nerve root stimulation in spinal cord injury. J Urol. 1997;157:1504\u20138.","journal-title":"J Urol"},{"key":"168_CR354","doi-asserted-by":"publisher","unstructured":"Rijnbeek EH, Eleveld N, Olthuis W. Update on peripheral nerve electrodes for closed-loop neuroprosthetics. Front Neurosci. 2018;12. https:\/\/doi.org\/10.3389\/fnins.2018.00350.","DOI":"10.3389\/fnins.2018.00350"},{"key":"168_CR355","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1097\/IAE.0000000000002394","volume":"40","author":"S Rizzo","year":"2020","unstructured":"Rizzo S, Barale P-O, Ayello-Scheer S, Devenyi RG, Delyfer M-N, Korobelnik J-F, Rachitskaya A, Yuan A, Jayasundera KT, Zacks DN, Handa JT, Montezuma SR, Koozekanani D, Stanga PE, da Cruz L, Walter P, Augustin AJ, Chizzolini M, Olmos de Koo LC, Ho AC, Kirchhof B, Hahn P, Vajzovic L, Iezzi R, Gaucher D, Arevalo JF, Gregori NZ, Grisanti S, \u00d6zmert E, Yoon YH, Kokame GT, Lim JI, Szurman P, de Juan E, Rezende FA, Salzmann J, Richard G, Huang SS, Merlini F, Patel U, Cruz C, Greenberg RJ, Justus S, Cinelli L, Humayun MS. ADVERSE EVENTS OF THE ARGUS II RETINAL PROSTHESIS: incidence, causes, and best practices for managing and preventing conjunctival erosion. Retina. 2020;40:303\u201311. https:\/\/doi.org\/10.1097\/IAE.0000000000002394.","journal-title":"Retina"},{"key":"168_CR356","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1038\/nnano.2011.249","volume":"7","author":"JT Robinson","year":"2012","unstructured":"Robinson JT, Jorgolli M, Shalek AK, Yoon M-H, Gertner RS, Park H. Vertical nanowire electrode arrays as a scalable platform for intracellular interfacing to neuronal circuits. Nature Nanotech. 2012;7:180\u20134. https:\/\/doi.org\/10.1038\/nnano.2011.249.","journal-title":"Nature Nanotech"},{"key":"168_CR357","doi-asserted-by":"publisher","unstructured":"Robinson J, Woods J, Alrashdan F, Chen E, Tan W, John M, Jaworski L, Beranrd D, Post A, Moctezuma-Ramirez A, Elgalad A, Steele A, Barber S, Horner P, Faraji A, Sayenko D, Razavi M. Scalable networks of wireless bioelectronics using magnetoelectrics. 2024.\u00a0https:\/\/doi.org\/10.21203\/rs.3.rs-5005441\/v1.","DOI":"10.21203\/rs.3.rs-5005441\/v1"},{"key":"168_CR358","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/s0165-0270(00)00192-8","volume":"98","author":"FJ Rodr\u00edguez","year":"2000","unstructured":"Rodr\u00edguez FJ, Ceballos D, Sch\u00fcttler M, Valero A, Valderrama E, Stieglitz T, Navarro X. Polyimide cuff electrodes for peripheral nerve stimulation. J Neurosci Methods. 2000;98:105\u201318. https:\/\/doi.org\/10.1016\/s0165-0270(00)00192-8.","journal-title":"J Neurosci Methods"},{"key":"168_CR359","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.eplepsyres.2016.02.004","volume":"122","author":"JD Rolston","year":"2016","unstructured":"Rolston JD, Englot DJ, Cornes S, Chang EF. Major and minor complications in extraoperative electrocorticography: A review of a national database. Epilepsy Res. 2016;122:26\u20139. https:\/\/doi.org\/10.1016\/j.eplepsyres.2016.02.004.","journal-title":"Epilepsy Res"},{"key":"168_CR360","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0165-0270(98)00031-4","volume":"82","author":"PJ Rousche","year":"1998","unstructured":"Rousche PJ, Normann RA. Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. J Neurosci Methods. 1998;82:1\u201315. https:\/\/doi.org\/10.1016\/S0165-0270(98)00031-4.","journal-title":"J Neurosci Methods"},{"key":"168_CR361","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1109\/10.914800","volume":"48","author":"PJ Rousche","year":"2001","unstructured":"Rousche PJ, Pellinen DS, Pivin DP, Williams JC, Vetter RJ, Kipke DR. Flexible polyimide-based intracortical electrode arrays with bioactive capability. IEEE Trans Biomed Eng. 2001;48:361\u201371. https:\/\/doi.org\/10.1109\/10.914800.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR362","doi-asserted-by":"publisher","first-page":"036003","DOI":"10.1088\/1741-2560\/6\/3\/036003","volume":"6","author":"B Rubehn","year":"2009","unstructured":"Rubehn B, Bosman C, Oostenveld R, Fries P, Stieglitz T. A MEMS-based flexible multichannel ECoG-electrode array. J Neural Eng. 2009;6:036003. https:\/\/doi.org\/10.1088\/1741-2560\/6\/3\/036003.","journal-title":"J Neural Eng"},{"key":"168_CR363","doi-asserted-by":"publisher","unstructured":"Rueb JJ, Pizarro-Berdichevsky J, Goldman HB. 17-year single center retrospective review of rate, risk factors, and outcomes of lead breakage during sacral neuromodulation lead removal. J Urol. 2020: 101097JU0000000000000740. https:\/\/doi.org\/10.1097\/JU.0000000000000740.","DOI":"10.1097\/JU.0000000000000740"},{"key":"168_CR364","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/j.biopsych.2005.05.025","volume":"58","author":"AJ Rush","year":"2005","unstructured":"Rush AJ, Marangell LB, Sackeim HA, George MS, Brannan SK, Davis SM, Howland R, Kling MA, Rittberg BR, Burke WJ, Rapaport MH, Zajecka J, Nierenberg AA, Husain MM, Ginsberg D, Cooke RG. Vagus nerve stimulation for treatment-resistant depression: a randomized, controlled acute phase trial. Biol Psychiatry. 2005;58:347\u201354. https:\/\/doi.org\/10.1016\/j.biopsych.2005.05.025.","journal-title":"Biol Psychiatry"},{"key":"168_CR365","doi-asserted-by":"publisher","first-page":"015002","DOI":"10.1088\/1741-2552\/abd0ce","volume":"18","author":"K Sahasrabuddhe","year":"2021","unstructured":"Sahasrabuddhe K, Khan AA, Singh AP, Stern TM, Ng Y, Tadi\u0107 A, Orel P, LaReau C, Pouzzner D, Nishimura K, Boergens KM, Shivakumar S, Hopper MS, Kerr B, Hanna M-ES, Edgington RJ, McNamara I, Fell D, Gao P, Babaie-Fishani A, Veijalainen S, Klekachev AV, Stuckey AM, Luyssaert B, Kozai TDY, Xie C, Gilja V, Dierickx B, Kong Y, Straka M, Sohal HS, Angle MR. The Argo: a high channel count recording system for neural recording in vivo. J Neural Eng. 2021;18:015002. https:\/\/doi.org\/10.1088\/1741-2552\/abd0ce.","journal-title":"J Neural Eng"},{"key":"168_CR366","doi-asserted-by":"publisher","first-page":">046011","DOI":"10.1088\/1741-2560\/11\/4\/046011","volume":"11","author":"AA Schendel","year":"2014","unstructured":"Schendel AA, Nonte MW, Vokoun C, Richner TJ, Brodnick SK, Atry F, Frye S, Bostrom P, Pashaie R, Thongpang S, Eliceiri KW, Williams JC. The effect of micro-ECoG substrate footprint on the meningeal tissue response. J Neural Eng. 2014;11:046011. https:\/\/doi.org\/10.1088\/1741-2560\/11\/4\/046011.","journal-title":"J Neural Eng"},{"key":"168_CR367","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1007\/BF01181577","volume":"5","author":"RL Schultz","year":"1976","unstructured":"Schultz RL, Willey TJ. The ultrastructure of the sheath around chronically implanted electrodes in brain. J Neurocytol. 1976;5:621\u201342. https:\/\/doi.org\/10.1007\/BF01181577.","journal-title":"J Neurocytol"},{"key":"168_CR368","first-page":"1553","volume":"78","author":"TM Seese","year":"1998","unstructured":"Seese TM, Harasaki H, Saidel GM, Davies CR. Characterization of tissue morphology, angiogenesis, and temperature in the adaptive response of muscle tissue to chronic heating. Lab Invest. 1998;78:1553\u201362.","journal-title":"Lab Invest"},{"key":"168_CR369","unstructured":"Medtronic. SenSight - DBS Directional Lead [WWW Document]. 2022. URL https:\/\/www.medtronic.com\/us-en\/healthcare-professionals\/products\/neurological\/deep-brain-stimulation-systems\/sensight-lead.html.\u00a0Accessed 10.30.23."},{"key":"168_CR370","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.neuron.2016.06.034","volume":"91","author":"D Seo","year":"2016","unstructured":"Seo D, Neely RM, Shen K, Singhal U, Alon E, Rabaey JM, Carmena JM, Maharbiz MM. Wireless recording in the peripheral nervous system with ultrasonic neural dust. Neuron. 2016;91:529\u201339. https:\/\/doi.org\/10.1016\/j.neuron.2016.06.034.","journal-title":"Neuron"},{"key":"168_CR371","doi-asserted-by":"publisher","first-page":"4606","DOI":"10.1109\/IEMBS.2006.260528","volume":"2006","author":"JP Seymour","year":"2006","unstructured":"Seymour JP, Kipke DR. Fabrication of polymer neural probes with sub-cellular features for reduced tissue encapsulation. Conf Proc IEEE Eng Med Biol Soc. 2006;2006:4606\u20139. https:\/\/doi.org\/10.1109\/IEMBS.2006.260528.","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"168_CR372","doi-asserted-by":"publisher","first-page":"3594","DOI":"10.1016\/j.biomaterials.2007.03.024","volume":"28","author":"JP Seymour","year":"2007","unstructured":"Seymour JP, Kipke DR. Neural probe design for reduced tissue encapsulation in CNS. Biomaterials. 2007;28:3594\u2013607. https:\/\/doi.org\/10.1016\/j.biomaterials.2007.03.024.","journal-title":"Biomaterials"},{"key":"168_CR373","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1007\/s10544-011-9512-z","volume":"13","author":"JP Seymour","year":"2011","unstructured":"Seymour JP, Langhals NB, Anderson DJ, Kipke DR. Novel multi-sided, microelectrode arrays for implantable neural applications. Biomed Microdevices. 2011;13:441\u201351. https:\/\/doi.org\/10.1007\/s10544-011-9512-z.","journal-title":"Biomed Microdevices"},{"key":"168_CR374","doi-asserted-by":"publisher","first-page":"L23","DOI":"10.1088\/1741-2560\/3\/4\/L02","volume":"3","author":"AA Sharp","year":"2006","unstructured":"Sharp AA, Panchawagh HV, Ortega A, Artale R, Richardson-Burns S, Finch DS, Gall K, Mahajan RL, Restrepo D. Toward a self-deploying shape memory polymer neuronal electrode. J Neural Eng. 2006;3:L23-30. https:\/\/doi.org\/10.1088\/1741-2560\/3\/4\/L02.","journal-title":"J Neural Eng"},{"key":"168_CR375","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1016\/j.bbrc.2005.08.252","volume":"336","author":"G Shaw","year":"2005","unstructured":"Shaw G, Yang C, Ellis R, Anderson K, Parker Mickle J, Scheff S, Pike B, Anderson DK, Howland DR. Hyperphosphorylated neurofilament NF-H is a serum biomarker of axonal injury. Biochem Biophys Res Commun. 2005;336:1268\u201377. https:\/\/doi.org\/10.1016\/j.bbrc.2005.08.252.","journal-title":"Biochem Biophys Res Commun"},{"key":"168_CR376","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1213\/00000539-196707000-00025","volume":"46","author":"CN Shealy","year":"1967","unstructured":"Shealy CN, Mortimer JT, Reswick JB. Electrical inhibition of pain by stimulation of the dorsal columns: preliminary clinical report. Anesth Analg. 1967;46:489\u201391.","journal-title":"Anesth Analg"},{"key":"168_CR377","doi-asserted-by":"publisher","first-page":"5671","DOI":"10.3390\/ma8095269","volume":"8","author":"Z Sheikh","year":"2015","unstructured":"Sheikh Z, Brooks PJ, Barzilay O, Fine N, Glogauer M. Macrophages, foreign body giant cells and their response to implantable biomaterials. Materials (Basel). 2015;8:5671\u2013701. https:\/\/doi.org\/10.3390\/ma8095269.","journal-title":"Materials (Basel)"},{"key":"168_CR378","doi-asserted-by":"publisher","unstructured":"Shepherd R, Wise A, Fallon J. Chapter 16 - Cochlear implants, in: Celesia, G.G. (Ed.), Handbook of clinical neurophysiology, disorders of peripheral and central auditory processing. Elsevier, 2013:315\u2013331. https:\/\/doi.org\/10.1016\/B978-0-7020-5310-8.00016-8.","DOI":"10.1016\/B978-0-7020-5310-8.00016-8"},{"key":"168_CR379","doi-asserted-by":"publisher","first-page":"041004","DOI":"10.1088\/1741-2552\/aac43c","volume":"15","author":"RK Shepherd","year":"2018","unstructured":"Shepherd RK, Villalobos J, Burns O, Nayagam DAX. The development of neural stimulators: a review of preclinical safety and efficacy studies. J Neural Eng. 2018;15:041004. https:\/\/doi.org\/10.1088\/1741-2552\/aac43c.","journal-title":"J Neural Eng"},{"key":"168_CR380","doi-asserted-by":"publisher","first-page":"026009","DOI":"10.1088\/1741-2552\/aaf66b","volume":"16","author":"RK Shepherd","year":"2019","unstructured":"Shepherd RK, Carter PM, Enke YL, Wise AK, Fallon JB. Chronic intracochlear electrical stimulation at high charge densities results in platinum dissolution but not neural loss or functional changes in vivo. J Neural Eng. 2019;16:026009. https:\/\/doi.org\/10.1088\/1741-2552\/aaf66b.","journal-title":"J Neural Eng"},{"key":"168_CR381","doi-asserted-by":"publisher","unstructured":"Shepherd RK, Carter P, Enke YL, Thompson A, Flynn B, Trang E, Dalrymple A, Fallon JB. Chronic intracochlear electrical stimulation at high charge densities: reducing platinum dissolution. J Neural Eng. 2020. https:\/\/doi.org\/10.1088\/1741-2552\/abb7a6.","DOI":"10.1088\/1741-2552\/abb7a6"},{"key":"168_CR382","doi-asserted-by":"publisher","first-page":"036021","DOI":"10.1088\/1741-2552\/abe5ba","volume":"18","author":"RK Shepherd","year":"2021","unstructured":"Shepherd RK, Carter PM, Dalrymple AN, Enke YL, Wise AK, Nguyen T, Firth J, Thompson A, Fallon JB. Platinum dissolution and tissue response following long-term electrical stimulation at high charge densities. J Neural Eng. 2021;18:036021. https:\/\/doi.org\/10.1088\/1741-2552\/abe5ba.","journal-title":"J Neural Eng"},{"key":"168_CR383","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1016\/j.wneu.2015.03.048","volume":"84","author":"S Shibata","year":"2015","unstructured":"Shibata S, Kunieda T, Inano R, Sawada M, Yamao Y, Kikuchi T, Matsumoto R, Ikeda A, Takahashi R, Mikuni N, Takahashi J, Miyamoto S. Risk factors for infective complications with long-term subdural electrode implantation in patients with medically intractable partial epilepsy. World Neurosurgery. 2015;84:320\u20136. https:\/\/doi.org\/10.1016\/j.wneu.2015.03.048.","journal-title":"World Neurosurgery"},{"key":"168_CR384","doi-asserted-by":"publisher","first-page":"12925","DOI":"10.1038\/s41598-021-91900-1","volume":"11","author":"JA Shulgach","year":"2021","unstructured":"Shulgach JA, Beam DW, Nanivadekar AC, Miller DM, Fulton S, Sciullo M, Ogren J, Wong L, McLaughlin BL, Yates BJ, Horn CC, Fisher LE. Selective stimulation of the ferret abdominal vagus nerve with multi-contact nerve cuff electrodes. Sci Rep. 2021;11:12925. https:\/\/doi.org\/10.1038\/s41598-021-91900-1.","journal-title":"Sci Rep"},{"key":"168_CR385","doi-asserted-by":"publisher","first-page":"8168","DOI":"10.3390\/ma7128168","volume":"7","author":"AT Sidambe","year":"2014","unstructured":"Sidambe AT. Biocompatibility of advanced manufactured titanium implants-a review. Materials (Basel). 2014;7:8168\u201388. https:\/\/doi.org\/10.3390\/ma7128168.","journal-title":"Materials (Basel)"},{"key":"168_CR386","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1016\/j.yebeh.2010.04.008","volume":"18","author":"F Siddiqui","year":"2010","unstructured":"Siddiqui F, Herial NA, Ali II. Cumulative effect of vagus nerve stimulators on intractable seizures observed over a period of 3years. Epilepsy Behav. 2010;18:299\u2013302. https:\/\/doi.org\/10.1016\/j.yebeh.2010.04.008.","journal-title":"Epilepsy Behav"},{"key":"168_CR387","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.juro.2017.07.010","volume":"199","author":"S Siegel","year":"2018","unstructured":"Siegel S, Noblett K, Mangel J, Bennett J, Griebling TL, Sutherland SE, Bird ET, Comiter C, Culkin D, Zylstra S, Kan F, Berg KC. Five-year followup results of a prospective, multicenter study of patients with overactive bladder treated with sacral neuromodulation. J Urol. 2018;199:229\u201336. https:\/\/doi.org\/10.1016\/j.juro.2017.07.010.","journal-title":"J Urol"},{"key":"168_CR388","doi-asserted-by":"publisher","first-page":"S11","DOI":"10.1093\/pm\/pnad092","volume":"24","author":"O Singh","year":"2023","unstructured":"Singh O, Carvalho DZ, Espay AJ, Benarroch EE, Grewal SS, Pagani-Est\u00e9vez GL. Spinal cord stimulation for gait impairment in Parkinson Disease: scoping review and mechanistic considerations. Pain Med. 2023;24:S11\u20137. https:\/\/doi.org\/10.1093\/pm\/pnad092.","journal-title":"Pain Med"},{"key":"168_CR389","doi-asserted-by":"publisher","first-page":"e13911","DOI":"10.1111\/nmo.13911","volume":"32","author":"V Sinniger","year":"2020","unstructured":"Sinniger V, Pellissier S, Fauvelle F, Trocm\u00e9 C, Hoffmann D, Vercueil L, Cracowski J-L, David O, Bonaz B. A 12-month pilot study outcomes of vagus nerve stimulation in Crohn\u2019s disease. Neurogastroenterol Motil. 2020;32:e13911. https:\/\/doi.org\/10.1111\/nmo.13911.","journal-title":"Neurogastroenterol Motil"},{"key":"168_CR390","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1136\/rapm-2018-000007","volume":"44","author":"E Sivanesan","year":"2019","unstructured":"Sivanesan E, Bicket MC, Cohen SP. Retrospective analysis of complications associated with dorsal root ganglion stimulation for pain relief in the FDA MAUDE database. Reg Anesth Pain Med. 2019;44:100\u20136. https:\/\/doi.org\/10.1136\/rapm-2018-000007.","journal-title":"Reg Anesth Pain Med"},{"key":"168_CR391","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1109\/tbme.1987.325979","volume":"34","author":"B Smith","year":"1987","unstructured":"Smith B, Peckham PH, Keith MW, Roscoe DD. An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle. IEEE Trans Biomed Eng. 1987;34:499\u2013508. https:\/\/doi.org\/10.1109\/tbme.1987.325979.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR392","doi-asserted-by":"publisher","first-page":"e0165606","DOI":"10.1371\/journal.pone.0165606","volume":"11","author":"HS Sohal","year":"2016","unstructured":"Sohal HS, Clowry GJ, Jackson A, O\u2019Neill A, Baker SN. Mechanical flexibility reduces the foreign body response to long-term implanted microelectrodes in rabbit cortex. PLoS ONE. 2016;11:e0165606. https:\/\/doi.org\/10.1371\/journal.pone.0165606.","journal-title":"PLoS ONE"},{"key":"168_CR393","doi-asserted-by":"publisher","first-page":"036027","DOI":"10.1088\/1741-2552\/aab55f","volume":"15","author":"ZJ Sperry","year":"2018","unstructured":"Sperry ZJ, Na K, Parizi SS, Chiel HJ, Seymour J, Yoon E, Bruns TM. Flexible microelectrode array for interfacing with the surface of neural ganglia. J Neural Eng. 2018;15:036027. https:\/\/doi.org\/10.1088\/1741-2552\/aab55f.","journal-title":"J Neural Eng"},{"key":"168_CR394","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/j.neurom.2022.03.014","volume":"26","author":"P Spindler","year":"2023","unstructured":"Spindler P, Braun F, Truckenm\u00fcller P, Wasilewski D, Faust K, Schneider G-H, Trampuz A, Conen A, K\u00fchn AA, Vajkoczy P, Prinz V. Surgical site infections associated with implanted pulse generators for deep brain stimulation: meta-analysis and systematic review. Neuromodulation. 2023;26:280\u201391. https:\/\/doi.org\/10.1016\/j.neurom.2022.03.014.","journal-title":"Neuromodulation"},{"key":"168_CR395","doi-asserted-by":"publisher","unstructured":"Sponheim C, Papadourakis V, Collinger JL, Downey J, Weiss J, Pentousi L, Elliott K, Hatsopoulos N. Longevity and reliability of chronic unit recordings using the Utah, intracortical multi-electrode Arrays. J Neural Eng. 2021;18.\u00a0https:\/\/doi.org\/10.1088\/1741-2552\/ac3eaf.","DOI":"10.1088\/1741-2552\/ac3eaf"},{"key":"168_CR396","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1038\/s41586-020-03180-w","volume":"590","author":"JW Squair","year":"2021","unstructured":"Squair JW, Gautier M, Mahe L, Soriano JE, Rowald A, Bichat A, Cho N, Anderson MA, James ND, Gandar J, Incognito AV, Schiavone G, Sarafis ZK, Laskaratos A, Bartholdi K, Demesmaeker R, Komi S, Moerman C, Vaseghi B, Scott B, Rosentreter R, Kathe C, Ravier J, McCracken L, Kang X, Vachicouras N, Fallegger F, Jelescu I, Cheng Y, Li Q, Buschman R, Buse N, Denison T, Dukelow S, Charbonneau R, Rigby I, Boyd SK, Millar PJ, Moraud EM, Capogrosso M, Wagner FB, Barraud Q, Bezard E, Lacour SP, Bloch J, Courtine G, Phillips AA. Neuroprosthetic baroreflex controls haemodynamics after spinal cord injury. Nature. 2021;590:308\u201314. https:\/\/doi.org\/10.1038\/s41586-020-03180-w.","journal-title":"Nature"},{"key":"168_CR397","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.actbio.2017.07.026","volume":"60","author":"S Sridar","year":"2017","unstructured":"Sridar S, Churchward MA, Mushahwar VK, Todd KG, Elias AL. Peptide modification of polyimide-insulated microwires: Towards improved biocompatibility through reduced glial scarring. Acta Biomater. 2017;60:154\u201366. https:\/\/doi.org\/10.1016\/j.actbio.2017.07.026.","journal-title":"Acta Biomater"},{"key":"168_CR398","doi-asserted-by":"publisher","first-page":"064001","DOI":"10.1088\/1741-2552\/ab4114","volume":"16","author":"AM Stiller","year":"2019","unstructured":"Stiller AM, Gonz\u00e1lez-Gonz\u00e1lez MA, Boothby JM, Sherman SE, Benavides J, Romero-Ortega M, Pancrazio JJ, Black BJ. Mechanical considerations for design and implementation of peripheral intraneural devices. J Neural Eng. 2019;16:064001. https:\/\/doi.org\/10.1088\/1741-2552\/ab4114.","journal-title":"J Neural Eng"},{"key":"168_CR399","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/BF01404668","volume":"47","author":"G Stock","year":"1979","unstructured":"Stock G, Sturm V, Schmitt HP, Schl\u00f6r KH. The influence of chronic deep brain stimulation on excitability and morphology of the stimulated tissue. Acta Neurochir. 1979;47:123\u20139. https:\/\/doi.org\/10.1007\/BF01404668.","journal-title":"Acta Neurochir"},{"key":"168_CR400","doi-asserted-by":"publisher","first-page":"Doc10","DOI":"10.3205\/cto000062","volume":"8","author":"T St\u00f6ver","year":"2011","unstructured":"St\u00f6ver T, Lenarz T. Biomaterials in cochlear implants. GMS Curr Top Otorhinolaryngol Head Neck Surg. 2011;8:Doc10. https:\/\/doi.org\/10.3205\/cto000062.","journal-title":"GMS Curr Top Otorhinolaryngol Head Neck Surg"},{"key":"168_CR401","doi-asserted-by":"publisher","first-page":"094301","DOI":"10.1063\/1.5024686","volume":"89","author":"MG Street","year":"2018","unstructured":"Street MG, Welle CG, Takmakov PA. Automated reactive accelerated aging for rapid in vitro evaluation of neural implant performance. Rev Sci Instrum. 2018;89:094301. https:\/\/doi.org\/10.1063\/1.5024686.","journal-title":"Rev Sci Instrum"},{"key":"168_CR402","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1088\/1741-2560\/2\/4\/006","volume":"2","author":"J Subbaroyan","year":"2005","unstructured":"Subbaroyan J, Martin DC, Kipke DR. A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex. J Neural Eng. 2005;2:103\u201313. https:\/\/doi.org\/10.1088\/1741-2560\/2\/4\/006.","journal-title":"J Neural Eng"},{"key":"168_CR403","doi-asserted-by":"publisher","first-page":"193","DOI":"10.2147\/RRU.S89544","volume":"8","author":"T Sukhu","year":"2016","unstructured":"Sukhu T, Kennelly MJ, Kurpad R. Sacral neuromodulation in overactive bladder: a review and current perspectives. Res Rep Urol. 2016;8:193\u20139. https:\/\/doi.org\/10.2147\/RRU.S89544.","journal-title":"Res Rep Urol"},{"key":"168_CR404","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s42234-023-00111-8","volume":"9","author":"AJ Suminski","year":"2023","unstructured":"Suminski AJ, Rajala AZ, Birn RM, Mueller EM, Malone ME, Ness JP, Filla C, Brunner K, McMillan AB, Poore SO, Williams JC, Murali D, Brzeczkowski A, Hurley SA, Dingle AM, Zeng W, Lake WB, Ludwig KA, Populin LC. Vagus nerve stimulation in the non-human primate: implantation methodology, characterization of nerve anatomy, target engagement and experimental applications. Bioelectron Med. 2023;9:9. https:\/\/doi.org\/10.1186\/s42234-023-00111-8.","journal-title":"Bioelectron Med"},{"key":"168_CR405","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1016\/j.jacbts.2020.07.010","volume":"5","author":"YB Sverrisdottir","year":"2020","unstructured":"Sverrisdottir YB, Martin SC, Hadjipavlou G, Kent AR, Paterson DJ, FitzGerald JJ, Green AL. Human dorsal root ganglion stimulation reduces sympathetic outflow and long-term blood pressure. JACC Basic Transl Sci. 2020;5:973\u201385. https:\/\/doi.org\/10.1016\/j.jacbts.2020.07.010.","journal-title":"JACC Basic Transl Sci"},{"key":"168_CR406","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/s0006-8993(03)03023-3","volume":"983","author":"DH Szarowski","year":"2003","unstructured":"Szarowski DH, Andersen MD, Retterer S, Spence AJ, Isaacson M, Craighead HG, Turner JN, Shain W. Brain responses to micro-machined silicon devices. Brain Res. 2003;983:23\u201335. https:\/\/doi.org\/10.1016\/s0006-8993(03)03023-3.","journal-title":"Brain Res"},{"key":"168_CR407","doi-asserted-by":"publisher","unstructured":"Szymanski LJ, Kellis S, Liu CY, Jones KT, Andersen RA, Commins D, Lee B, McCreery DB, Miller CA. Neuropathological effects of chronically implanted, intracortical microelectrodes in a tetraplegic patient. J Neural Eng. 2021;18. https:\/\/doi.org\/10.1088\/1741-2552\/ac127e.","DOI":"10.1088\/1741-2552\/ac127e"},{"key":"168_CR408","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1039\/b417497f","volume":"5","author":"S Takeuchi","year":"2005","unstructured":"Takeuchi S, Ziegler D, Yoshida Y, Mabuchi K, Suzuki T. Parylene flexible neural probes integrated with microfluidic channels. Lab Chip. 2005;5:519\u201323. https:\/\/doi.org\/10.1039\/b417497f.","journal-title":"Lab Chip"},{"key":"168_CR409","doi-asserted-by":"publisher","first-page":"026003","DOI":"10.1088\/1741-2560\/12\/2\/026003","volume":"12","author":"P Takmakov","year":"2015","unstructured":"Takmakov P, Ruda K, Scott Phillips K, Isayeva IS, Krauthamer V, Welle CG. Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species. J Neural Eng. 2015;12:026003. https:\/\/doi.org\/10.1088\/1741-2560\/12\/2\/026003.","journal-title":"J Neural Eng"},{"key":"168_CR410","doi-asserted-by":"publisher","unstructured":"Tan DW, Schiefer MA, Keith MW, Anderson JR, Tyler J, Tyler DJ. A neural interface provides long-term stable natural touch perception. Sci Transl Med. 2014;6:257ra138\u2013257ra138. https:\/\/doi.org\/10.1126\/scitranslmed.3008669.","DOI":"10.1126\/scitranslmed.3008669"},{"key":"168_CR411","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/S0022-5347(17)38751-7","volume":"142","author":"EA Tanagho","year":"1989","unstructured":"Tanagho EA, Schmidt RA, Orvis BR. Neural stimulation for control of voiding dysfunction: a preliminary report in 22 patients with serious neuropathic voiding disorders. J Urol. 1989;142:340\u20135.","journal-title":"J Urol"},{"key":"168_CR412","doi-asserted-by":"publisher","first-page":"8841","DOI":"10.1073\/pnas.95.15.8841","volume":"95","author":"L Tang","year":"1998","unstructured":"Tang L, Jennings TA, Eaton JW. Mast cells mediate acute inflammatory responses to implanted biomaterials. Proc Natl Acad Sci USA. 1998;95:8841\u20136. https:\/\/doi.org\/10.1073\/pnas.95.15.8841.","journal-title":"Proc Natl Acad Sci USA"},{"key":"168_CR413","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/B978-0-444-52137-8.00018-8","volume":"109","author":"CH Tator","year":"2012","unstructured":"Tator CH, Minassian K, Mushahwar VK. Spinal cord stimulation: therapeutic benefits and movement generation after spinal cord injury. Handb Clin Neurol. 2012;109:283\u201396. https:\/\/doi.org\/10.1016\/B978-0-444-52137-8.00018-8.","journal-title":"Handb Clin Neurol"},{"key":"168_CR414","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1111\/aor.14562","volume":"48","author":"O Tawakol","year":"2024","unstructured":"Tawakol O, Herman MD, Foxley S, Mushahwar VK, Towle VL, Troyk PR. In-vivo testing of a novel wireless intraspinal microstimulation interface for restoration of motor function following spinal cord injury. Artif Organs. 2024;48:263\u201373. https:\/\/doi.org\/10.1111\/aor.14562.","journal-title":"Artif Organs"},{"key":"168_CR415","doi-asserted-by":"publisher","unstructured":"Tebcherani TM, Loparo KA, Kaffashi F, Tyler DJ, Graczyk EL. Interleaved multi-contact peripheral nerve stimulation to enhance reproduction of tactile sensation: a computational modeling study. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2024:1\u20131. https:\/\/doi.org\/10.1109\/TNSRE.2024.3414939.","DOI":"10.1109\/TNSRE.2024.3414939"},{"key":"168_CR416","doi-asserted-by":"publisher","first-page":"3185","DOI":"10.1002\/adfm.201203716","volume":"23","author":"LW Tien","year":"2013","unstructured":"Tien LW, Wu F, Tang-Schomer MD, Yoon E, Omenetto FG, Kaplan DL. Silk as a multifunctional biomaterial substrate for reduced glial scarring around brain-penetrating electrodes. Adv Func Mater. 2013;23:3185\u201393. https:\/\/doi.org\/10.1002\/adfm.201203716.","journal-title":"Adv Func Mater"},{"key":"168_CR417","doi-asserted-by":"publisher","unstructured":"Tilz RR, P\u00fcrerfellner H, Kuck K-H, Merino JL, Schmidt V, Vogler J, Xiang K, Uzunoglu EC, Heeger C-H, Tandri H, Assis F, Steven D, Veltmann C, Catanzaro JN, Popescu SS. Underreporting of complications following AF ablation: comparison of the manufacturer and user facility device experience fda database and a voluntary invitation-based registry: the POTTER-AF 3 study. Heart Rhythm. 2024. https:\/\/doi.org\/10.1016\/j.hrthm.2024.09.060.","DOI":"10.1016\/j.hrthm.2024.09.060"},{"key":"168_CR418","doi-asserted-by":"publisher","unstructured":"Ting JE, Hooper CA, Dalrymple AN, Weber DJ. Tonic stimulation of dorsal root ganglion results in progressive decline in recruitment of A\u03b1\/\u03b2-fibers in rats. Neuromodulation: Technology at the Neural Interface. 2024;27:1347\u20131359. https:\/\/doi.org\/10.1016\/j.neurom.2024.06.498.","DOI":"10.1016\/j.neurom.2024.06.498"},{"key":"168_CR419","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.seizure.2020.09.027","volume":"83","author":"DH Toffa","year":"2020","unstructured":"Toffa DH, Touma L, El Meskine T, Bouthillier A, Nguyen DK. Learnings from 30 years of reported efficacy and safety of vagus nerve stimulation (VNS) for epilepsy treatment: a critical review. Seizure. 2020;83:104\u201323. https:\/\/doi.org\/10.1016\/j.seizure.2020.09.027.","journal-title":"Seizure"},{"key":"168_CR420","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1007\/s10439-016-1709-0","volume":"45","author":"A Toossi","year":"2017","unstructured":"Toossi A, Everaert DG, Azar A, Dennison CR, Mushahwar VK. Mechanically stable intraspinal microstimulation implants for human translation. Ann Biomed Eng. 2017;45:681\u201394. https:\/\/doi.org\/10.1007\/s10439-016-1709-0.","journal-title":"Ann Biomed Eng"},{"key":"168_CR421","doi-asserted-by":"publisher","first-page":"045010","DOI":"10.1088\/1741-2552\/ab9d11","volume":"17","author":"VL Towle","year":"2020","unstructured":"Towle VL, Pytel P, Lane F, Plass J, Frim DM, Troyk PR. Postmortem investigation of a human cortical visual prosthesis that was implanted for 36 years. J Neural Eng. 2020;17:045010. https:\/\/doi.org\/10.1088\/1741-2552\/ab9d11.","journal-title":"J Neural Eng"},{"key":"168_CR422","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1109\/TPHP.1977.1135193","volume":"13","author":"R Traeger","year":"1977","unstructured":"Traeger R. Nonhermeticity of polymeric lid sealants. IEEE Trans Parts Hybrids Packaging. 1977;13:147\u201352. https:\/\/doi.org\/10.1109\/TPHP.1977.1135193.","journal-title":"IEEE Trans Parts Hybrids Packaging"},{"key":"168_CR423","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1615\/critrevbiomedeng.v39.i1.30","volume":"39","author":"PA Tresco","year":"2011","unstructured":"Tresco PA, Winslow BD. The challenge of integrating devices into the central nervous system. Crit Rev Biomed Eng. 2011;39:29\u201344. https:\/\/doi.org\/10.1615\/critrevbiomedeng.v39.i1.30.","journal-title":"Crit Rev Biomed Eng"},{"key":"168_CR424","doi-asserted-by":"publisher","first-page":"1900892","DOI":"10.1002\/adhm.201900892","volume":"8","author":"JK Trevathan","year":"2019","unstructured":"Trevathan JK, Baumgart IW, Nicolai EN, Gosink BA, Asp AJ, Settell ML, Polaconda SR, Malerick KD, Brodnick SK, Zeng W, Knudsen BE, McConico AL, Sanger Z, Lee JH, Aho JM, Suminski AJ, Ross EK, Lujan JL, Weber DJ, Williams JC, Franke M, Ludwig KA, Shoffstall AJ. An injectable neural stimulation electrode made from an in-body curing polymer\/metal composite. Adv Healthcare Mater. 2019;8:1900892. https:\/\/doi.org\/10.1002\/adhm.201900892.","journal-title":"Adv Healthcare Mater"},{"key":"168_CR425","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1016\/j.apmr.2012.01.001","volume":"93","author":"RJ Triolo","year":"2012","unstructured":"Triolo RJ, Bailey SN, Miller ME, Rohde LM, Anderson JS, Davis JA, Abbas JJ, DiPonio LA, Forrest GP, Gater DR, Yang LJ. Longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury. Arch Phys Med Rehabil. 2012;93:896\u2013904. https:\/\/doi.org\/10.1016\/j.apmr.2012.01.001.","journal-title":"Arch Phys Med Rehabil"},{"key":"168_CR426","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.apmr.2017.08.470","volume":"99","author":"RJ Triolo","year":"2018","unstructured":"Triolo RJ, Bailey SN, Foglyano KM, Kobetic R, Lombardo LM, Miller ME, Pinault G. Long-term performance and user satisfaction with implanted neuroprostheses for upright mobility after Paraplegia: 2- to 14-year follow-up. Arch Phys Med Rehabil. 2018;99:289\u201398. https:\/\/doi.org\/10.1016\/j.apmr.2017.08.470.","journal-title":"Arch Phys Med Rehabil"},{"key":"168_CR427","doi-asserted-by":"publisher","first-page":"1414","DOI":"10.1109\/TBME.2012.2237172","volume":"60","author":"P Troyk","year":"2013","unstructured":"Troyk P, Hu Z. Simplified design equations for Class-E neural prosthesis transmitters. IEEE Trans Biomed Eng. 2013;60:1414\u201321. https:\/\/doi.org\/10.1109\/TBME.2012.2237172.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR428","doi-asserted-by":"publisher","unstructured":"Troyk PR, Rush AD. Inductive link design for miniature implants, in: 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Presented at the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2009:204\u2013209. https:\/\/doi.org\/10.1109\/IEMBS.2009.5333621.","DOI":"10.1109\/IEMBS.2009.5333621"},{"key":"168_CR429","doi-asserted-by":"publisher","first-page":"7376","DOI":"10.1109\/IEMBS.2005.1616216","volume":"2005","author":"PR Troyk","year":"2005","unstructured":"Troyk PR, Bradley D, Bak M, Cogan S, Erickson R, Hu Z, Kufta C, McCreery D, Schmidt E, Sung S, Towle V. Intracortical visual prosthesis research - approach and progress. Conf Proc IEEE Eng Med Biol Soc. 2005;2005:7376\u20139. https:\/\/doi.org\/10.1109\/IEMBS.2005.1616216.","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"168_CR430","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1006\/exnr.1998.6983","volume":"156","author":"JN Turner","year":"1999","unstructured":"Turner JN, Shain W, Szarowski DH, Andersen M, Martins S, Isaacson M, Craighead H. Cerebral astrocyte response to micromachined silicon implants. Exp Neurol. 1999;156:33\u201349. https:\/\/doi.org\/10.1006\/exnr.1998.6983.","journal-title":"Exp Neurol"},{"key":"168_CR431","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1109\/TNSRE.2002.806840","volume":"10","author":"DJ Tyler","year":"2002","unstructured":"Tyler DJ, Durand DM. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. IEEE Trans Neural Syst Rehabil Eng. 2002;10:294\u2013303. https:\/\/doi.org\/10.1109\/TNSRE.2002.806840.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"168_CR432","doi-asserted-by":"publisher","unstructured":"Vanloon M, Van Broeckhoven T, Raymaekers V, De Ridder D, Billet B, Meeuws S, Menovsky T, Plazier M. Noninfectious complications of dorsal root ganglion stimulation: a systematic review and meta-analysis. Neuromodulation: Technology at the Neural Interface 2025;28:234\u2013248. https:\/\/doi.org\/10.1016\/j.neurom.2024.10.010.","DOI":"10.1016\/j.neurom.2024.10.010"},{"key":"168_CR433","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.actbio.2019.03.037","volume":"90","author":"H Vara","year":"2019","unstructured":"Vara H, Collazos-Castro JE. Enhanced spinal cord microstimulation using conducting polymer-coated carbon microfibers. Acta Biomater. 2019;90:71\u201386. https:\/\/doi.org\/10.1016\/j.actbio.2019.03.037.","journal-title":"Acta Biomater"},{"key":"168_CR434","doi-asserted-by":"publisher","first-page":"120924","DOI":"10.1016\/j.biomaterials.2021.120924","volume":"275","author":"A Veith","year":"2021","unstructured":"Veith A, Li X, Modi H, Abbaspour A, Luan L, Xie C, Baker AB. Optimized design of a hyperflexible sieve electrode to enhance neurovascular regeneration for a peripheral neural interface. Biomaterials. 2021;275:120924. https:\/\/doi.org\/10.1016\/j.biomaterials.2021.120924.","journal-title":"Biomaterials"},{"key":"168_CR435","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1109\/TNSRE.2011.2109399","volume":"19","author":"S Venkatraman","year":"2011","unstructured":"Venkatraman S, Hendricks J, King ZA, Sereno AJ, Richardson-Burns S, Martin D, Carmena JM. In vitro and in vivo evaluation of PEDOT microelectrodes for neural stimulation and recording. IEEE Trans Neural Syst Rehabil Eng. 2011;19:307\u201316. https:\/\/doi.org\/10.1109\/TNSRE.2011.2109399.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"168_CR436","doi-asserted-by":"publisher","first-page":"74","DOI":"10.3389\/fninf.2019.00074","volume":"13","author":"K Volkova","year":"2019","unstructured":"Volkova K, Lebedev MA, Kaplan A, Ossadtchi A. Decoding movement from electrocorticographic activity: a review. Front Neuroinform. 2019;13:74. https:\/\/doi.org\/10.3389\/fninf.2019.00074.","journal-title":"Front Neuroinform"},{"key":"168_CR437","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.jconrel.2005.10.027","volume":"110","author":"R Wadhwa","year":"2006","unstructured":"Wadhwa R, Lagenaur CF, Cui XT. Electrochemically controlled release of dexamethasone from conducting polymer polypyrrole coated electrode. J Control Release. 2006;110:531\u201341. https:\/\/doi.org\/10.1016\/j.jconrel.2005.10.027.","journal-title":"J Control Release"},{"key":"168_CR438","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1038\/s41586-018-0649-2","volume":"563","author":"FB Wagner","year":"2018","unstructured":"Wagner FB, Mignardot J-B, Le Goff-Mignardot CG, Demesmaeker R, Komi S, Capogrosso M, Rowald A, Se\u00e1\u00f1ez I, Caban M, Pirondini E, Vat M, McCracken LA, Heimgartner R, Fodor I, Watrin A, Seguin P, Paoles E, Van Den Keybus K, Eberle G, Schurch B, Pralong E, Becce F, Prior J, Buse N, Buschman R, Neufeld E, Kuster N, Carda S, von Zitzewitz J, Delattre V, Denison T, Lambert H, Minassian K, Bloch J, Courtine G. Targeted neurotechnology restores walking in humans with spinal cord injury. Nature. 2018;563:65\u201371. https:\/\/doi.org\/10.1038\/s41586-018-0649-2.","journal-title":"Nature"},{"key":"168_CR439","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1016\/j.pneurobio.2010.08.001","volume":"92","author":"J Wang","year":"2010","unstructured":"Wang J. Preclinical and clinical research on inflammation after intracerebral hemorrhage. Prog Neurobiol. 2010;92:463\u201377. https:\/\/doi.org\/10.1016\/j.pneurobio.2010.08.001.","journal-title":"Prog Neurobiol"},{"key":"168_CR440","doi-asserted-by":"publisher","first-page":"E11","DOI":"10.3171\/2018.5.FOCUS18163","volume":"45","author":"TR Wang","year":"2018","unstructured":"Wang TR, Moosa S, Dallapiazza RF, Elias WJ, Lynch WJ. Deep brain stimulation for the treatment of drug addiction. Neurosurg Focus. 2018;45:E11. https:\/\/doi.org\/10.3171\/2018.5.FOCUS18163.","journal-title":"Neurosurg Focus"},{"key":"168_CR441","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.brainres.2009.05.052","volume":"1282","author":"MP Ward","year":"2009","unstructured":"Ward MP, Rajdev P, Ellison C, Irazoqui PP. Toward a comparison of microelectrodes for acute and chronic recordings. Brain Res. 2009;1282:183\u2013200. https:\/\/doi.org\/10.1016\/j.brainres.2009.05.052.","journal-title":"Brain Res"},{"key":"168_CR442","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.1016\/S1474-4422(14)70117-6","volume":"13","author":"RJ Ward","year":"2014","unstructured":"Ward RJ, Zucca FA, Duyn JH, Crichton RR, Zecca L. The role of iron in brain ageing and neurodegenerative disorders. Lancet Neurol. 2014;13:1045\u201360. https:\/\/doi.org\/10.1016\/S1474-4422(14)70117-6.","journal-title":"Lancet Neurol"},{"key":"168_CR443","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/jbmb.32946","volume":"102","author":"T Ware","year":"2014","unstructured":"Ware T, Simon D, Liu C, Musa T, Vasudevan S, Sloan A, Keefer EW, Rennaker RL II, Voit W. Thiol-ene\/acrylate substrates for softening intracortical electrodes. J Biomed Mater Res B Appl Biomater. 2014;102:1\u201311. https:\/\/doi.org\/10.1002\/jbmb.32946.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"168_CR444","unstructured":"Weber C. Closed-loop control neural activity technology roadmap white paper v2. 2020. https:\/\/brain.ieee.org\/publications\/research-and-white-papers\/future-neural-therapeutics-closed-loop-control-of-neural-activity\/."},{"key":"168_CR445","doi-asserted-by":"publisher","first-page":"046008","DOI":"10.1088\/1741-2560\/6\/4\/046008","volume":"6","author":"XF Wei","year":"2009","unstructured":"Wei XF, Grill WM. Impedance characteristics of deep brain stimulation electrodes in vitro and in vivo. J Neural Eng. 2009;6:046008. https:\/\/doi.org\/10.1088\/1741-2560\/6\/4\/046008.","journal-title":"J Neural Eng"},{"key":"168_CR446","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1109\/TBME.2008.2005942","volume":"56","author":"RF Weir","year":"2009","unstructured":"Weir RF, Troyk PR, DeMichele GA, Kerns DA, Schorsch JF, Maas H. Implantable Myoelectric Sensors (IMESs) for intramuscular electromyogram recording. IEEE Trans Biomed Eng. 2009;56:159\u201371. https:\/\/doi.org\/10.1109\/TBME.2008.2005942.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR447","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1159\/000442893","volume":"94","author":"GA White-Dzuro","year":"2016","unstructured":"White-Dzuro GA, Lake W, Eli IM, Neimat JS. Novel approach to securing deep brain stimulation leads: technique and analysis of lead migration, breakage, and surgical infection. Stereotact Funct Neurosurg. 2016;94:18\u201323. https:\/\/doi.org\/10.1159\/000442893.","journal-title":"Stereotact Funct Neurosurg"},{"key":"168_CR448","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1109\/TBME.1982.324910","volume":"29","author":"JD Wiley","year":"1982","unstructured":"Wiley JD, Webster JG. Analysis and control of the current distribution under circular dispersive electrodes. IEEE Trans Biomed Eng. 1982;29:381\u20135. https:\/\/doi.org\/10.1109\/TBME.1982.324910.","journal-title":"IEEE Trans Biomed Eng"},{"key":"168_CR449","doi-asserted-by":"publisher","first-page":"e0147552","DOI":"10.1371\/journal.pone.0147552","volume":"11","author":"M Wilk","year":"2016","unstructured":"Wilk M, Hessler R, Mugridge K, Jolly C, Fehr M, Lenarz T, Scheper V. Impedance changes and fibrous tissue growth after cochlear implantation are correlated and can be reduced using a dexamethasone eluting electrode. PLoS ONE. 2016;11:e0147552. https:\/\/doi.org\/10.1371\/journal.pone.0147552.","journal-title":"PLoS ONE"},{"key":"168_CR450","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1038\/s41586-021-03506-2","volume":"593","author":"FR Willett","year":"2021","unstructured":"Willett FR, Avansino DT, Hochberg LR, Henderson JM, Shenoy KV. High-performance brain-to-text communication via handwriting. Nature. 2021;593:249\u201354. https:\/\/doi.org\/10.1038\/s41586-021-03506-2.","journal-title":"Nature"},{"key":"168_CR451","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1038\/s41586-023-06377-x","volume":"620","author":"FR Willett","year":"2023","unstructured":"Willett FR, Kunz EM, Fan C, Avansino DT, Wilson GH, Choi EY, Kamdar F, Glasser MF, Hochberg LR, Druckmann S, Shenoy KV, Henderson JM. A high-performance speech neuroprosthesis. Nature. 2023;620:1031\u20136. https:\/\/doi.org\/10.1038\/s41586-023-06377-x.","journal-title":"Nature"},{"key":"168_CR452","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1088\/1741-2560\/4\/4\/007","volume":"4","author":"JC Williams","year":"2007","unstructured":"Williams JC, Hippensteel JA, Dilgen J, Shain W, Kipke DR. Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants. J Neural Eng. 2007;4:410\u201323. https:\/\/doi.org\/10.1088\/1741-2560\/4\/4\/007.","journal-title":"J Neural Eng"},{"key":"168_CR453","doi-asserted-by":"publisher","first-page":"4405","DOI":"10.1002\/adma.201500218","volume":"27","author":"A Williamson","year":"2015","unstructured":"Williamson A, Ferro M, Leleux P, Ismailova E, Kaszas A, Doublet T, Quilichini P, Rivnay J, R\u00f3zsa B, Katona G, Bernard C, Malliaras GG. Localized neuron stimulation with organic electrochemical transistors on delaminating depth probes. Adv Mater. 2015;27:4405\u201310. https:\/\/doi.org\/10.1002\/adma.201500218.","journal-title":"Adv Mater"},{"key":"168_CR454","doi-asserted-by":"publisher","first-page":"9163","DOI":"10.1016\/j.biomaterials.2010.05.050","volume":"31","author":"BD Winslow","year":"2010","unstructured":"Winslow BD, Christensen MB, Yang W-K, Solzbacher F, Tresco PA. A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex. Biomaterials. 2010;31:9163\u201372. https:\/\/doi.org\/10.1016\/j.biomaterials.2010.05.050.","journal-title":"Biomaterials"},{"key":"168_CR455","doi-asserted-by":"publisher","first-page":"759711","DOI":"10.3389\/fbioe.2021.759711","volume":"9","author":"K Woeppel","year":"2021","unstructured":"Woeppel K, Hughes C, Herrera AJ, Eles JR, Tyler-Kabara EC, Gaunt RA, Collinger JL, Cui XT. Explant analysis of Utah electrode arrays implanted in human cortex for brain-computer-interfaces. Front Bioeng Biotechnol. 2021;9:759711. https:\/\/doi.org\/10.3389\/fbioe.2021.759711.","journal-title":"Front Bioeng Biotechnol"},{"key":"168_CR456","doi-asserted-by":"publisher","first-page":"101891","DOI":"10.1016\/j.inat.2023.101891","volume":"36","author":"Z Xiao","year":"2024","unstructured":"Xiao Z, Gong L, Chang G, Long X, Pan Z, Guo X, Wang Y, Zhang Y, Ma W, Guo Y. Skin erosion following deep brain stimulator implantation: a case report. Interdiscip Neurosurg. 2024;36:101891. https:\/\/doi.org\/10.1016\/j.inat.2023.101891.","journal-title":"Interdiscip Neurosurg"},{"key":"168_CR457","doi-asserted-by":"publisher","first-page":"1286","DOI":"10.1038\/nmat4427","volume":"14","author":"C Xie","year":"2015","unstructured":"Xie C, Liu J, Fu T-M, Dai X, Zhou W, Lieber CM. Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes. Nat Mater. 2015;14:1286\u201392. https:\/\/doi.org\/10.1038\/nmat4427.","journal-title":"Nat Mater"},{"key":"168_CR458","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/s0378-5955(96)00193-1","volume":"105","author":"J Xu","year":"1997","unstructured":"Xu J, Shepherd RK, Millard RE, Clark GM. Chronic electrical stimulation of the auditory nerve at high stimulus rates: a physiological and histopathological study. Hear Res. 1997;105:1\u201329. https:\/\/doi.org\/10.1016\/s0378-5955(96)00193-1.","journal-title":"Hear Res"},{"key":"168_CR459","doi-asserted-by":"publisher","first-page":"201","DOI":"10.3171\/jns.2004.101.2.0201","volume":"101","author":"T Yamamoto","year":"2004","unstructured":"Yamamoto T, Katayama Y, Kano T, Kobayashi K, Oshima H, Fukaya C. Deep brain stimulation for the treatment of parkinsonian, essential, and poststroke tremor: a suitable stimulation method and changes in effective stimulation intensity. J Neurosurg. 2004;101:201\u20139. https:\/\/doi.org\/10.3171\/jns.2004.101.2.0201.","journal-title":"J Neurosurg"},{"key":"168_CR460","doi-asserted-by":"publisher","unstructured":"Yan JS, Orecchioni M, Vitale F, Coco JA, Duret G, Antonucci S, Pamulapati SS, Taylor LW, Dewey OS, Di Sante M. Biocompatibility studies of macroscopic fibers made from carbon nanotubes: Implications for carbon nanotube macrostructures in biomedical applications. Carbon. 2021;173:462\u201376.\u00a0https:\/\/doi.org\/10.1016\/j.carbon.2020.10.077.","DOI":"10.1016\/j.carbon.2020.10.077"},{"key":"168_CR461","doi-asserted-by":"publisher","first-page":"e2200311","DOI":"10.1002\/smll.202200311","volume":"18","author":"D Yan","year":"2022","unstructured":"Yan D, Jiman AA, Bottorff EC, Patel PR, Meli D, Welle EJ, Ratze DC, Havton LA, Chestek CA, Kemp SWP, Bruns TM, Yoon E, Seymour JP. Ultraflexible and stretchable intrafascicular peripheral nerve recording device with axon-dimension. Cuff-Less Microneedle Electrode Array Small. 2022;18:e2200311. https:\/\/doi.org\/10.1002\/smll.202200311.","journal-title":"Cuff-Less Microneedle Electrode Array Small"},{"key":"168_CR462","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.jocn.2003.10.003","volume":"11","author":"J Yianni","year":"2004","unstructured":"Yianni J, Nandi D, Shad A, Bain P, Gregory R, Aziz T. Increased risk of lead fracture and migration in dystonia compared with other movement disorders following deep brain stimulation. J Clin Neurosci. 2004;11:243\u20135. https:\/\/doi.org\/10.1016\/j.jocn.2003.10.003.","journal-title":"J Clin Neurosci"},{"key":"168_CR463","doi-asserted-by":"publisher","first-page":"032204","DOI":"10.1117\/1.NPh.9.3.032204","volume":"9","author":"R Yin","year":"2022","unstructured":"Yin R, Noble BC, He F, Zolotavin P, Rathore H, Jin Y, Sevilla N, Xie C, Luan L. Chronic co-implantation of ultraflexible neural electrodes and a cranial window. Nph. 2022;9:032204. https:\/\/doi.org\/10.1117\/1.NPh.9.3.032204.","journal-title":"Nph"},{"key":"168_CR464","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1093\/gastro\/gou015","volume":"2","author":"AP Zbar","year":"2014","unstructured":"Zbar AP. Sacral neuromodulation and peripheral nerve stimulation in patients with anal incontinence: an overview of techniques, complications and troubleshooting. Gastroenterol Rep (Oxf). 2014;2:112\u201320. https:\/\/doi.org\/10.1093\/gastro\/gou015.","journal-title":"Gastroenterol Rep (Oxf)"},{"key":"168_CR465","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1109\/RBME.2008.2008250","volume":"1","author":"F-G Zeng","year":"2008","unstructured":"Zeng F-G, Rebscher S, Harrison W, Sun X, Feng H. Cochlear implants: system design, integration, and evaluation. IEEE Rev Biomed Eng. 2008;1:115\u201342. https:\/\/doi.org\/10.1109\/RBME.2008.2008250.","journal-title":"IEEE Rev Biomed Eng"},{"key":"168_CR466","doi-asserted-by":"publisher","first-page":"4588","DOI":"10.1021\/acs.nanolett.7b00956","volume":"17","author":"Z Zhao","year":"2017","unstructured":"Zhao Z, Luan L, Wei X, Zhu H, Li X, Lin S, Siegel JJ, Chitwood RA, Xie C. Nanoelectronic coating enabled versatile multifunctional neural probes. Nano Lett. 2017;17:4588\u201395. https:\/\/doi.org\/10.1021\/acs.nanolett.7b00956.","journal-title":"Nano Lett"},{"key":"168_CR467","doi-asserted-by":"publisher","first-page":"035001","DOI":"10.1088\/1741-2552\/ab05b6","volume":"16","author":"Z Zhao","year":"2019","unstructured":"Zhao Z, Li X, He F, Wei X, Lin S, Xie C. Parallel, minimally-invasive implantation of ultra-flexible neural electrode arrays. J Neural Eng. 2019;16:035001. https:\/\/doi.org\/10.1088\/1741-2552\/ab05b6.","journal-title":"J Neural Eng"},{"key":"168_CR468","doi-asserted-by":"publisher","unstructured":"Zhao Z, Zhu H, Li X, Sun L, He F, Chung JE, Liu DF, Frank L, Luan L, Xie C. Ultraflexible electrode arrays for months-long high-density electrophysiological mapping of thousands of neurons in rodents. Nat Biomed Eng. 2022. https:\/\/doi.org\/10.1038\/s41551-022-00941-y.","DOI":"10.1038\/s41551-022-00941-y"},{"key":"168_CR469","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.jconrel.2005.05.012","volume":"106","author":"Y Zhong","year":"2005","unstructured":"Zhong Y, Bellamkonda RV. Controlled release of anti-inflammatory agent alpha-MSH from neural implants. J Control Release. 2005;106:309\u201318. https:\/\/doi.org\/10.1016\/j.jconrel.2005.05.012.","journal-title":"J Control Release"},{"key":"168_CR470","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.brainres.2007.02.024","volume":"1148","author":"Y Zhong","year":"2007","unstructured":"Zhong Y, Bellamkonda RV. Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes. Brain Res. 2007;1148:15\u201327. https:\/\/doi.org\/10.1016\/j.brainres.2007.02.024.","journal-title":"Brain Res"}],"container-title":["Bioelectronic Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42234-025-00168-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42234-025-00168-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42234-025-00168-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T20:03:49Z","timestamp":1741896229000},"score":1,"resource":{"primary":{"URL":"https:\/\/bioelecmed.biomedcentral.com\/articles\/10.1186\/s42234-025-00168-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,14]]},"references-count":470,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["168"],"URL":"https:\/\/doi.org\/10.1186\/s42234-025-00168-7","relation":{},"ISSN":["2332-8886"],"issn-type":[{"value":"2332-8886","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,14]]},"assertion":[{"value":"18 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"DJW is a founder and shareholder of Reach Neuro, Inc., consultant and shareholder of Neuronoff, Inc., shareholder and scientific board member for NeuroOne Medical, Inc., and a shareholder of Bionic Power Inc., Iota Biosciences Inc., and Blackfynn Inc. JBF is Chair of the Scientific Board of Hemidemia, but does not have a financial interest. The other authors have no relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript. This includes employment, consultancies, honoraria, stock ownership or options, expert testimony, grants or patents received or pending, or royalties.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"6"}}