{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:49:36Z","timestamp":1792788576747,"version":"4.5.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,27]],"date-time":"2025-12-27T00:00:00Z","timestamp":1766793600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,27]],"date-time":"2025-12-27T00:00:00Z","timestamp":1766793600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100023835","name":"BRAIN Initiative","doi-asserted-by":"publisher","award":["UG3NS107688"],"award-info":[{"award-number":["UG3NS107688"]}],"id":[{"id":"10.13039\/100023835","id-type":"DOI","asserted-by":"publisher"}]},{"name":"WVU Startup Funding for Prof. Rieth"},{"name":"Blackrock Neurotech Industry Contract"},{"name":"DARPA HAPTIX","award":["N66001-15-C-4017"],"award-info":[{"award-number":["N66001-15-C-4017"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Bioelectron Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The Utah electrode array (UEA) is a promising microelectrode technology with potential applications to assist patients with sensory loss, spinal cord injuries, and limb loss serving as neural prosthetics and brain-computer interfaces. Performance lifetime of microelectrodes, particularly when used for stimulation, remains one of the challenges for their clinical translation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This study characterizes the stimulation stability of an optimized iridium oxide (IrOx)\n                      <jats:italic>research<\/jats:italic>\n                      metallization for the UEA in comparison to the Blackrock standard practice metallization. The stimulation stability (Stim-Stab) protocol used electrochemical characterization and either 10\n                      <jats:sup>6<\/jats:sup>\n                      or 4\u2009\u00d7\u200910\n                      <jats:sup>6<\/jats:sup>\n                      pulses at 2,100\n                      <jats:italic>\u00b5<\/jats:italic>\n                      A (420 nC\/ph) with longitudinal voltage transient measurements and physical characterization to quantify electrode lifetime.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Approximately 50% of electrodes using the Blackrock standard practice process electrical failed during 10\n                      <jats:sup>6<\/jats:sup>\n                      pulses, whereas no electrical failures were observed from 4\u2009\u00d7\u200910\n                      <jats:sup>6<\/jats:sup>\n                      pulses for the\n                      <jats:italic>research<\/jats:italic>\n                      metallization. Backscattered scanning electron microscopy (BSEM) determined that all electrodes with electrical failures during Stim-Stab testing had complete loss of metallization. Of electrodes with good electrical outcomes from Stim-Stab testing 80% and 50% of those had notable metallization damage for\n                      <jats:italic>BRM<\/jats:italic>\n                      and\n                      <jats:italic>research<\/jats:italic>\n                      metallization, respectively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      These results suggest that the\n                      <jats:italic>research<\/jats:italic>\n                      metallization makes important steps for improving electrode metallization lifetime of Utah arrays. Additionally, the Stim-Stab method provides valuable feedback for engineering improved electrode metallization.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s42234-025-00190-9","type":"journal-article","created":{"date-parts":[[2025,12,27]],"date-time":"2025-12-27T00:02:09Z","timestamp":1766793729000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Improved electrode stimulation stability of Utah arrays*"],"prefix":"10.1186","volume":"11","author":[{"given":"Taylor","family":"Stump","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"Baker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Caldwell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohit","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandeep","family":"Negi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Loren","family":"Rieth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,27]]},"reference":[{"issue":"5","key":"190_CR1","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1097\/00005537-200305000-00012","volume":"113","author":"AN Badi","year":"2003","unstructured":"Badi AN, Kertesz TR, Gurgel RK, Shelton C, Normann RA. Development of a novel eighth-nerve intraneural auditory neuroprosthesis. Laryngoscope. 2003;113(5):833\u201342.","journal-title":"Laryngoscope"},{"key":"190_CR2","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.actbio.2025.02.030","volume":"198","author":"DA Bj\u00e5nes","year":"2025","unstructured":"Bj\u00e5nes DA, Kellis S, Nickl R, Baker B, Aflalo T, Bashford L, et al. Quantifying physical degradation alongside recording and stimulation performance of 980 intracortical microelectrodes chronically implanted in three humans for 956\u20132130 days. Acta Biomater. 2025;198:188\u2013206.","journal-title":"Acta Biomater"},{"key":"190_CR3","doi-asserted-by":"crossref","unstructured":"Caldwell R, Street MG, Sharma R, Takmakov P, Baker B, Rieth L. Characterization of Parylene-C degradation mechanisms: In vitro reactive accelerated aging model compared to multiyear in vivo implantation. Biomaterials. 2020;232:119731.","DOI":"10.1016\/j.biomaterials.2019.119731"},{"key":"190_CR4","doi-asserted-by":"crossref","unstructured":"Campbell PK, Jones KE, Huber RJ, Horch KW, Normann RA. A Silicon-Based, Three-Dimensional Neural Interface: Manufacturing Processes for an Intracortical Electrode Array. lEEE Trans Biomed Eng. 1991;38(8):758-68.","DOI":"10.1109\/10.83588"},{"key":"190_CR5","doi-asserted-by":"crossref","unstructured":"Chen KH, Dammann JF, Boback JL, Tenore F V., Otto KJ, Gaunt RA, Bensmaia SJ. The effect of chronic intracortical microstimulation on the electrode-tissue interface. J Neural Eng. 2014;11(2):026004.","DOI":"10.1088\/1741-2560\/11\/2\/026004"},{"issue":"2","key":"190_CR6","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1146\/annurev.bioeng.10.061807.160518","volume":"10","author":"SF Cogan","year":"2008","unstructured":"Cogan SF. Neural stimulation and recording electrodes. Annu Rev Biomed Eng. 2008;10(2):275\u2013309.","journal-title":"Annu Rev Biomed Eng"},{"issue":"2","key":"190_CR7","doi-asserted-by":"publisher","first-page":"021001","DOI":"10.1088\/1741-2560\/13\/2\/021001","volume":"13","author":"SF Cogan","year":"2016","unstructured":"Cogan SF, Ludwig KA, Welle CG, Takmakov P. Tissue damage thresholds during therapeutic electrical stimulation. J Neural Eng. 2016;13(2):021001.","journal-title":"J Neural Eng"},{"issue":"7","key":"190_CR8","doi-asserted-by":"publisher","first-page":"E679","DOI":"10.1212\/WNL.0000000000013173","volume":"98","author":"MS Fifer","year":"2022","unstructured":"Fifer MS, McMullen DP, Osborn LE, Thomas TM, Christie B, Nickl RW, et al. Intracortical Somatosensory Stimulation to Elicit Fingertip Sensations in an Individual with Spinal Cord Injury. Neurology. 2022;98(7):E679\u201387.","journal-title":"Neurology"},{"issue":"361","key":"190_CR9","doi-asserted-by":"publisher","first-page":"361ra141","DOI":"10.1126\/scitranslmed.aaf8083","volume":"8","author":"SN Flesher","year":"2016","unstructured":"Flesher SN, Collinger JL, Foldes ST, Weiss JM, Downey JE, Tyler-Kabara EC, et al. Intracortical microstimulation of human somatosensory cortex. Sci Transl Med. 2016;8(361):361ra141.","journal-title":"Sci Transl Med"},{"key":"190_CR10","doi-asserted-by":"crossref","unstructured":"George JA, Kluger DT, Davis TS, Wendelken SM, Okorokova E V, He Q, Duncan CC, Hutchinson DT, Thumser ZC, Beckler DT, Marasco PD, Bensmaia SJ, Clark GA. Biomimetic sensory feedback through peripheral nerve stimulation improves dexterous use of a bionic hand. Sci Robot. 2019;4(32):eaax2352.","DOI":"10.1126\/scirobotics.aax2352"},{"key":"190_CR11","doi-asserted-by":"crossref","unstructured":"George JA, Page DM, Davis TS, Duncan CC, Hutchinson DT, Rieth LW, Clark GA. Long-term performance of Utah slanted electrode arrays and intramuscular electromyographic leads implanted chronically in human arm nerves and muscles. J Neural Eng. 2020;17(5):056042.","DOI":"10.1088\/1741-2552\/abc025"},{"key":"190_CR12","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1007\/BF02368134","volume":"20","author":"KE Jones","year":"1992","unstructured":"Jones KE, Campbell PK, Normann RA. A glass\/silicon composite intracortical electrode array. Ann Biomed Eng. 1992;20:423\u201337.","journal-title":"Ann Biomed Eng"},{"issue":"7679","key":"190_CR13","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1038\/nature24636","volume":"551","author":"JJ Jun","year":"2017","unstructured":"Jun JJ, Steinmetz NA, Siegle JH, Denman DJ, Bauza M, Barbarits B, et al. Fully integrated silicon probes for high-density recording of neural activity. Nature. 2017;551(7679):232\u20136.","journal-title":"Nature"},{"key":"190_CR14","doi-asserted-by":"crossref","unstructured":"Jung T, Zeng N, Fabbri JD, Eichler G, Li Z, Zabeh E, Das A, Willeke K, Wingel KE, Dubey A, Huq R, Sharma M, Hu Y, Ramakrishnan G, Tien K, Mantovani P, Parihar A, Yin H, Oswalt D, Misdorp A, Uguz I, Shinn T, Rodriguez GJ, Nealley C, Sanborn S, Gonzales I, Roukes M, Knecht J, Yoshor D, Canoll P, Spinazzi E, Carloni LP, Pesaran B, Patel S, Jacobs J, Youngerman B, Cotton RJ, Tolias A, Shepard KL. Stable, chronic in-vivo recordings from a fully wireless subdural-contained 65,536-electrode brain-computer interface device.2024.05.17.59433.","DOI":"10.1101\/2024.05.17.594333"},{"issue":"49","key":"190_CR15","doi-asserted-by":"publisher","first-page":"15202","DOI":"10.1073\/pnas.1509265112","volume":"112","author":"S Kim","year":"2015","unstructured":"Kim S, Callier T, Tabot GA, Gaunt RA, Tenore FV, Bensmaia SJ. Behavioral assessment of sensitivity to intracortical microstimulation of primate somatosensory cortex. Proc Natl Acad Sci USA. 2015;112(49):15202\u20137.","journal-title":"Proc Natl Acad Sci USA"},{"key":"190_CR16","doi-asserted-by":"crossref","unstructured":"Konrad P, Gelman KR, Lawrence J, Bhatia S, Jacqueline D, Sharma R, Ho E, Byun YW, Mermel CH, Rapoport BI. First-in-human experience performing high-resolution cortical mapping using a novel microelectrode array containing 1024 electrodes. J Neural Eng. 2025;22(2):026009.","DOI":"10.1088\/1741-2552\/adaeed"},{"issue":"3","key":"190_CR17","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1002\/jbm.b.34442","volume":"108","author":"J Maeng","year":"2020","unstructured":"Maeng J, Chakraborty B, Geramifard N, Kang T, Rihani RT, Joshi-Imre A, et al. High-charge-capacity sputtered iridium oxide neural stimulation electrodes deposited using water vapor as a reactive plasma constituent. J Biomed Mater Res B Appl Biomater. 2020;108(3):880\u201391.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"issue":"1\u20132","key":"190_CR18","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.heares.2008.04.001","volume":"242","author":"JC Middlebrooks","year":"2008","unstructured":"Middlebrooks JC, Snyder RL. Intraneural stimulation for auditory prosthesis: modiolar trunk and intracranial stimulation sites. Hear Res. 2008;242(1\u20132):52\u201363.","journal-title":"Hear Res"},{"issue":"1","key":"190_CR19","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.jneumeth.2009.10.016","volume":"186","author":"S Negi","year":"2010","unstructured":"Negi S, Bhandari R, Rieth L, Van Wagenen R, Solzbacher F. Neural electrode degradation from continuous electrical stimulation: comparison of sputtered and activated iridium oxide. J Neurosci Methods. 2010a;186(1):8\u201317.","journal-title":"J Neurosci Methods"},{"issue":"1","key":"190_CR20","doi-asserted-by":"publisher","first-page":"15007","DOI":"10.1088\/1748-6041\/5\/1\/015007","volume":"5","author":"S Negi","year":"2010","unstructured":"Negi S, Bhandari R, Rieth L, Solzbacher F. In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays. Biomed Mater. 2010b;5(1):15007.","journal-title":"Biomed Mater"},{"issue":"2","key":"190_CR21","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1109\/TBME.2005.862530","volume":"53","author":"KJ Otto","year":"2006","unstructured":"Otto KJ, Johnson MD, Kipke DR. Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes. IEEE Trans Biomed Eng. 2006;53(2):333\u201340.","journal-title":"IEEE Trans Biomed Eng"},{"key":"190_CR22","doi-asserted-by":"publisher","first-page":"352","DOI":"10.3389\/fnhum.2018.00352","volume":"12","author":"DM Page","year":"2018","unstructured":"Page DM, George JA, Kluger DT, Duncan C, Wendelken S, Davis T, et al. Motor control and sensory feedback enhance prosthesis embodiment and reduce phantom pain after long-term hand amputation. Front Hum Neurosci. 2018;12:352.","journal-title":"Front Hum Neurosci"},{"issue":"1","key":"190_CR23","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s12984-021-00808-4","volume":"18","author":"DM Page","year":"2021","unstructured":"Page DM, George JA, Wendelken SM, Davis TS, Kluger DT, Hutchinson DT, et al. Discriminability of multiple cutaneous and proprioceptive hand percepts evoked by intraneural stimulation with Utah slanted electrode arrays in human amputees. J Neuroeng Rehabil. 2021;18(1):12.","journal-title":"J Neuroeng Rehabil"},{"key":"190_CR24","doi-asserted-by":"crossref","unstructured":"Rajan AT, Boback JL, Dammann JF, Tenore F V., Wester BA, Otto KJ, Gaunt RA, Bensmaia SJ. The effects of chronic intracortical microstimulation on neural tissue and fine motor behavior. J Neural Eng. 2015;12(6):066018.","DOI":"10.1088\/1741-2560\/12\/6\/066018"},{"issue":"664","key":"190_CR25","doi-asserted-by":"publisher","first-page":"eabq4744","DOI":"10.1126\/scitranslmed.abq4744","volume":"14","author":"SM Russman","year":"2025","unstructured":"Russman SM, Cleary DR, Tchoe Y, Bourhis AM, Stedelin B, Martin J, et al. Constructing 2D maps of human spinal cord activity and isolating the functional midline with high-density microelectrode arrays. Sci Transl Med. 2025;14(664):eabq4744.","journal-title":"Sci Transl Med."},{"key":"190_CR26","doi-asserted-by":"publisher","first-page":"e32904","DOI":"10.7554\/eLife.32904","volume":"7","author":"MA Salas","year":"2018","unstructured":"Salas MA, Bashford L, Kellis S, Jafari M, Jo H, Kramer D, et al. Proprioceptive and cutaneous sensations in humans elicited by intracortical microstimulation. Elife. 2018;7:e32904.","journal-title":"Elife."},{"issue":"7","key":"190_CR27","doi-asserted-by":"publisher","first-page":"E226","DOI":"10.1149\/1.1747881","volume":"151","author":"E Slavcheva","year":"2004","unstructured":"Slavcheva E, Vitushinsky R, Mokwa W, Schnakenberg U. Sputtered iridium oxide films as charge injection material for functional electrostimulation. J Electrochem Soc. 2004;151(7):E226.","journal-title":"J Electrochem Soc"},{"key":"190_CR28","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.actbio.2023.01.026","volume":"159","author":"T Sun","year":"2023","unstructured":"Sun T, Tsaava T, Peragine J, Crosfield C, Lopez MF, Modi R, et al. Flexible IrOx neural electrode for mouse vagus nerve stimulation. Acta Biomater. 2023;159:394\u2013409.","journal-title":"Acta Biomater"},{"key":"190_CR29","doi-asserted-by":"crossref","unstructured":"Thomas WM, Gurgel RK, Warren DJ. Pilot Performance of a Chronic Intraneural Auditory Neuroprosthesis in Felines. In: International IEEE\/EMBS Conference on Neural Engineering, NER. Baltimore: IEEE Computer Society; 2023;(1-5):10123798.","DOI":"10.1109\/NER52421.2023.10123798"},{"key":"190_CR30","doi-asserted-by":"crossref","unstructured":"Thomas WM, Zuniga SA, Sondh I, Leber M, Solzbacher F, Lenarz T, Lim H, Warren D, Rieth L, Adams M. Development of a feline model for preclinical research of a new translabyrinthine auditory nerve implant. Front Neurosci. 2024;18:1308663.","DOI":"10.3389\/fnins.2024.1308663"},{"issue":"1","key":"190_CR31","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1186\/s12984-017-0320-4","volume":"14","author":"S Wendelken","year":"2017","unstructured":"Wendelken S, Page DM, Davis T, Wark HAC, Kluger DT, Duncan C, et al. Restoration of motor control and proprioceptive and cutaneous sensation in humans with prior upper-limb amputation via multiple Utah Slanted Electrode Arrays (USEAs) implanted in residual peripheral arm nerves. J Neuroeng Rehabil. 2017;14(1):121.","journal-title":"J Neuroeng Rehabil"}],"container-title":["Bioelectronic Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42234-025-00190-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42234-025-00190-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42234-025-00190-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T15:42:33Z","timestamp":1781624553000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s42234-025-00190-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,27]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["190"],"URL":"https:\/\/doi.org\/10.1186\/s42234-025-00190-9","relation":{},"ISSN":["2332-8886"],"issn-type":[{"value":"2332-8886","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,27]]},"assertion":[{"value":"28 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"N\/A.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Research at WVU Loren Rieth and Taylor Stump are partially supported by a research contract by Blackrock Neurotech. Sandeep Negi is an employee of Blackrock Neurotech.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"30"}}