{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T01:45:44Z","timestamp":1782179144206,"version":"3.54.5"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T00:00:00Z","timestamp":1765324800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T00:00:00Z","timestamp":1765324800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["EP\/R004498\/1"],"award-info":[{"award-number":["EP\/R004498\/1"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Bioelectron Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Damage to the peripheral nervous system severely disrupts motor control, sensory perception, and organ function, often resulting in long-term disability. To restore such impairments, peripheral nerve interfaces (PNIs) aim to achieve precise stimulation selectivity, yet current approaches face several limitations. Most PNIs rely on metal-based electrodes, which introduce a mechanical mismatch with soft neural tissue and are limited by low charge-injection capacity. The device design of these PNIs also suffers from a fundamental trade-off: highly invasive approaches enable high selectivity but provoke strong foreign-body responses, while less invasive designs minimize tissue damage but fail to provide sufficient selectivity. Although current-steering strategies have been explored to enhance selectivity, their performance remains inadequate for clinical application. Significant advances in PNIs are required to safely achieve higher selectivity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this work, a novel array consisting of a single penetrating interfascicular electrode (SPIF) added to an extraneural cuff (EC) array, termed SPIFEC, was developed using laser-based fabrication and polymeric materials. Electrochemical properties were characterized, and ex vivo experiments using whole rat sciatic nerve were conducted to assess fascicular selectivity. The implantation was assessed through computed tomography (CT) imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The SPIFEC design includes seven extraneural electrodes and one double-sided interfascicular penetrating electrode. Electrochemical analysis revealed the polymeric electrodes had low impedance, high charge storage capacity and high charge-injection limit, when compared to previous reports on traditional metallic devices. Ex vivo studies demonstrated that the device achieved high fascicular selectivity, particularly in nerves with well-defined fascicles, outperforming a comparable non-penetrating cuff. CT imaging confirmed the interfascicular positioning of the penetrating electrode.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>These results demonstrate the potential of this novel SPIFEC array in enhancing spatial selectivity for peripheral nerve applications. Further studies, including chronic in vivo testing, are required to fully evaluate long-term performance and clinical potential in neuroprosthetic systems.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s42234-025-00193-6","type":"journal-article","created":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T00:02:19Z","timestamp":1765324939000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Using a single penetrating interfascicular electrode to improve spatial selectivity of an extraneural polymeric cuff array"],"prefix":"10.1186","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-2224-8586","authenticated-orcid":false,"given":"Imane","family":"Ben M\u2019Rad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2274-5914","authenticated-orcid":false,"given":"Zachary K.","family":"Bailey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7957-2348","authenticated-orcid":false,"given":"Estelle A.","family":"Cuttaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1569-7288","authenticated-orcid":false,"given":"Rylie A.","family":"Green","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,10]]},"reference":[{"issue":"4","key":"193_CR1","doi-asserted-by":"publisher","first-page":"046017","DOI":"10.1088\/1741-2552\/ac7d0e","volume":"19","author":"O Akouissi","year":"2022","unstructured":"Akouissi O, Lacour SP, Micera S, Desimone A. A finite element model of the mechanical interactions between peripheral nerves and intrafascicular implants. J Neural Eng. 2022;19(4):046017. https:\/\/doi.org\/10.1088\/1741-2552\/ac7d0e.","journal-title":"J Neural Eng"},{"issue":"8","key":"193_CR2","doi-asserted-by":"publisher","first-page":"2324","DOI":"10.1109\/TBME.2011.2153850","volume":"58","author":"J Badia","year":"2011","unstructured":"Badia J, Boretius T, Pascual-Font A, Udina E, Stieglitz T, Navarro X. Biocompatibility of chronically implanted transverse intrafascicular multichannel electrode (TIME) in the rat sciatic nerve. IEEE Trans Biomed Eng. 2011;58(8):2324\u201332.","journal-title":"IEEE Trans Biomed Eng"},{"key":"193_CR3","doi-asserted-by":"crossref","unstructured":"Bailey Z, Nairac Z, Cuttaz EA, Ben M\u2019Rad I, Chapman CAR, Rapeaux A, et al. Neuromodulation of a peripheral nerve using fully polymeric cuff electrodes: Understanding predictability of selective stimulation. bioRxiv. Cold Spring Harbor Laboratory; 2025. p. 2025.10.28.685203. Available from:\u00a0http:\/\/biorxiv.org\/lookup\/doi\/10.1101\/2025.10.28.685203. Cited 2025 Nov 3","DOI":"10.1101\/2025.10.28.685203"},{"issue":"1","key":"193_CR4","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.bios.2010.05.010","volume":"26","author":"T Boretius","year":"2010","unstructured":"Boretius T, Badia J, Pascual-Font A, Schuettler M, Navarro X, Yoshida K, et al. A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. Biosens Bioelectron. 2010;26(1):62\u20139.","journal-title":"Biosens Bioelectron"},{"issue":"1","key":"193_CR5","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1109\/TBME.2003.820321","volume":"51","author":"A Branner","year":"2004","unstructured":"Branner A, Stein RB, Fernandez E, Aoyagi Y, Normann RA. Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve. IEEE Trans Biomed Eng. 2004;51(1):146\u201357.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6","key":"193_CR6","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.3171\/2019.2.JNS183542","volume":"132","author":"AE Carolus","year":"2020","unstructured":"Carolus AE, Lenz M, Hofmann M, Welp H, Schmieder K, Brenke C. High-resolution in vivo imaging of peripheral nerves using optical coherence tomography: a feasibility study. J Neurosurg. 2020;132(6):1907\u201313. Available from: https:\/\/pubmed.ncbi.nlm.nih.gov\/31026830\/. Cited 2025 May 4.","journal-title":"J Neurosurg."},{"issue":"1","key":"193_CR7","doi-asserted-by":"publisher","first-page":"270","DOI":"10.3171\/2019.8.JNS191278","volume":"134","author":"AE Carolus","year":"2021","unstructured":"Carolus AE, M\u00f6ller J, Hofmann MR, van de Nes JAP, Welp H, Schmieder K, et al. Comparison between optical coherence tomography imaging and histological sections of peripheral nerves. J Neurosurg. 2021;134(1):270\u20137. Available from: https:\/\/thejns.org\/doi\/abs\/10.3171\/2019.8.JNS191278. Cited 2025 May 4.","journal-title":"J Neurosurg."},{"issue":"2","key":"193_CR8","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1109\/10.909637","volume":"48","author":"AQ Choi","year":"2001","unstructured":"Choi AQ, Cavanaugh JK, Durand DM. Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis. IEEE Trans Biomed Eng. 2001;48(2):165\u201372.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"193_CR9","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1146\/annurev.bioeng.10.061807.160518","volume":"10","author":"SF Cogan","year":"2008","unstructured":"Cogan SF. Neural stimulation and recording electrodes. Annu Rev Biomed Eng. 2008;10(1):275\u2013309. Available from: https:\/\/www.annualreviews.org\/doi\/10.1146\/annurev.bioeng.10.061807.160518. Cited 2024 Mar 9.","journal-title":"Annu Rev Biomed Eng."},{"key":"193_CR10","doi-asserted-by":"crossref","unstructured":"Courties A, Berenbaum F, Sellam J. Vagus nerve stimulation in musculoskeletal diseases. Vol. 88, Joint Bone Spine. Elsevier Masson s.r.l.; 2021. p. 105149.","DOI":"10.1016\/j.jbspin.2021.105149"},{"issue":"4","key":"193_CR11","doi-asserted-by":"publisher","first-page":"1372","DOI":"10.1039\/C8BM01235K","volume":"7","author":"E Cuttaz","year":"2019","unstructured":"Cuttaz E, Goding J, Vallejo-Giraldo C, Aregueta-Robles U, Lovell N, Ghezzi D, et al. Conductive elastomer composites for fully polymeric, flexible bioelectronics. Biomater Sci. 2019;7(4):1372\u201385. https:\/\/doi.org\/10.1039\/C8BM01235K.","journal-title":"Biomater Sci"},{"issue":"8","key":"193_CR12","doi-asserted-by":"publisher","first-page":"2004033","DOI":"10.1002\/advs.202004033","volume":"8","author":"EA Cuttaz","year":"2021","unstructured":"Cuttaz EA, Chapman CAR, Syed O, Goding JA, Green RA. Stretchable, fully polymeric electrode arrays for peripheral nerve stimulation. Adv Sci. 2021;8(8):2004033. Available from: https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/advs.202004033. Cited 2024 Feb 7.","journal-title":"Adv Sci."},{"issue":"2","key":"193_CR13","doi-asserted-by":"publisher","first-page":"026032","DOI":"10.1088\/1741-2552\/acc42b","volume":"20","author":"CJ Davis","year":"2023","unstructured":"Davis CJ, Musselman ED, Grill WM, Pelot NA. Fibers in smaller fascicles have lower activation thresholds with cuff electrodes due to thinner perineurium and smaller cross-sectional area. J Neural Eng. 2023;20(2):026032. https:\/\/doi.org\/10.1088\/1741-2552\/acc42b.","journal-title":"J Neural Eng"},{"key":"193_CR14","doi-asserted-by":"publisher","unstructured":"Fitchett A, Mastitskaya S, Aristovich K. Selective Neuromodulation of the Vagus Nerve. Vol. 15, Frontiers in Neuroscience. Frontiers Media S.A.; 2021. p. 685872. Available from: https:\/\/www.frontiersin.org\/articles\/https:\/\/doi.org\/10.3389\/fnins.2021.685872\/full Cited 2024 Feb 7","DOI":"10.3389\/fnins.2021.685872\/full"},{"issue":"42","key":"193_CR15","doi-asserted-by":"publisher","first-page":"1703019","DOI":"10.1002\/adfm.201703019","volume":"27","author":"M Ganji","year":"2017","unstructured":"Ganji M, Tanaka A, Gilja V, Halgren E, Dayeh SA. Scaling Effects on the Electrochemical Stimulation Performance of Au, Pt, and PEDOT:PSS Electrocorticography Arrays. Adv Funct Mater. 2017;27(42):1703019. Available from: https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/adfm.201703019. Cited 2025 Aug 19.","journal-title":"Adv Funct Mater."},{"issue":"1","key":"193_CR16","doi-asserted-by":"publisher","first-page":"16390","DOI":"10.1038\/s41598-018-34566-6","volume":"8","author":"MA Gonz\u00e1lez-Gonz\u00e1lez","year":"2018","unstructured":"Gonz\u00e1lez-Gonz\u00e1lez MA, Kanneganti A, Joshi-Imre A, Hernandez-Reynoso AG, Bendale G, Modi R, et al. Thin film multi-electrode softening cuffs for selective neuromodulation. Sci Rep. 2018;8(1):16390. Available from: www.nature.com\/scientificreports\/. Cited 2025 Aug 22.","journal-title":"Sci Rep."},{"issue":"9","key":"193_CR17","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1109\/10.83604","volume":"38","author":"EV Goodall","year":"1991","unstructured":"Goodall EV, Lefurge TM, Horch KW. Information contained in sensory nerve recordings made with intrafascicular electrodes. IEEE Trans Biomed Eng. 1991;38(9):846\u201350.","journal-title":"IEEE Trans Biomed Eng"},{"key":"193_CR18","unstructured":"Green RA, Toor H, Dodds C, Lovell NH. Variation in Performance of Platinum Electrodes with Size and Surface Roughness. Vol. 24, Sensors and Materials. 2012."},{"key":"193_CR19","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1038\/s41551-018-0342-7","volume":"3","author":"R Green","year":"2019","unstructured":"Green R. Elastic and conductive hydrogel electrodes. Nat Biomed Eng. 2019;3:9\u201310. https:\/\/doi.org\/10.1038\/s41551-018-0342-7.","journal-title":"Nat Biomed Eng"},{"key":"193_CR20","doi-asserted-by":"crossref","unstructured":"Green R, Abidian MR. Conducting Polymers for Neural Prosthetic and Neural Interface Applications. Vol. 27, Advanced materials (Deerfield Beach, Fla.). John Wiley & Sons, Ltd; 2015. p. 7620\u201337.\u00a0Available from: https:\/\/onlinelibrary.wiley.com\/doi\/full\/10.1002\/adma.201501810. Cited 2024 Feb 8","DOI":"10.1002\/adma.201501810"},{"issue":"1","key":"193_CR21","doi-asserted-by":"publisher","first-page":"55","DOI":"10.2217\/bem-2017-0009","volume":"1","author":"R Jung","year":"2018","unstructured":"Jung R, Abbas JJ, Kuntaegowdanahalli S, Thota AK. Bionic intrafascicular interfaces for recording and stimulating peripheral nerve fibers. Bioelectron Med. 2018;1(1):55\u201369 Available from: www.futuremedicine.com","journal-title":"Bioelectron Med."},{"key":"193_CR22","doi-asserted-by":"crossref","unstructured":"Larson CE, Meng E. A review for the peripheral nerve interface designer. Vol. 332, Journal of Neuroscience Methods. Elsevier B.V.; 2020. p. 108523.","DOI":"10.1016\/j.jneumeth.2019.108523"},{"key":"193_CR23","doi-asserted-by":"crossref","unstructured":"Ortiz-Catalan M, Br\u00e5nemark R, H\u00e5kansson B, Delbeke J. On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion. Vol. 11, BioMedical Engineering Online. BioMed Central; 2012. p. 33. Available from:\u00a0http:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/1475-925X-11-33. Cited 2025 Oct 13","DOI":"10.1186\/1475-925X-11-33"},{"key":"193_CR24","doi-asserted-by":"crossref","unstructured":"Paggi V, Fallegger F, Serex L, Rizzo O, Galan K, Giannotti A, et al. A soft, scalable and adaptable multi-contact cuff electrode for targeted peripheral nerve modulation. Bioelectron Med. 2024;10(1):6.\u00a0Available from: https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC10865708\/. Cited 2025 Aug 4.","DOI":"10.1186\/s42234-023-00137-y"},{"key":"193_CR25","doi-asserted-by":"crossref","unstructured":"Panskus R, Holzapfel L, Serdijn WA, Giagka V. On the Stimulation Artifact Reduction during Electrophysiological Recording of Compound Nerve Action Potentials. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. Institute of Electrical and Electronics Engineers Inc.; 2023.","DOI":"10.1109\/EMBC40787.2023.10341179"},{"issue":"5","key":"193_CR26","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1109\/TNSRE.2009.2032603","volume":"17","author":"KH Polasek","year":"2009","unstructured":"Polasek KH, Hoyen HA, Keith MW, Kirsch RF, Tyler DJ. Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity. IEEE Trans Neural Syst Rehabil Eng. 2009;17(5):428\u201337.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"193_CR27","doi-asserted-by":"crossref","unstructured":"Raspopovic S, Capogrosso M, Petrini FM, Bonizzato M, Rigosa J, Pino G Di, et al. Restoring natural sensory feedback in real-time bidirectional hand prostheses. Sci Transl Med. 2014;6(222). Available from:\u00a0https:\/\/www.science.org\/doi\/10.1126\/scitranslmed.3006820. Cited 2024 Jan 28.","DOI":"10.1126\/scitranslmed.3006820"},{"key":"193_CR28","doi-asserted-by":"crossref","unstructured":"Roche AD, Bailey ZK, Gonzalez M, Vu PP, Chestek CA, Gates DH, et al. Upper limb prostheses: bridging the sensory gap. Vol. 48, Journal of Hand Surgery: European Volume. SAGE Publications Ltd; 2023. p. 182\u201390.\u00a0Available from: https:\/\/journals.sagepub.com\/doi\/full\/10.1177\/17531934221131756. Cited 2024 Jan 28.","DOI":"10.1177\/17531934221131756"},{"key":"193_CR29","doi-asserted-by":"crossref","unstructured":"Shi Y, Liu R, He L, Feng H, Li Y, Li Z. Recent development of implantable and flexible nerve electrodes. Vol. 1, Smart Materials in Medicine. KeAi Communications Co.; 2020. p. 131\u201347.","DOI":"10.1016\/j.smaim.2020.08.002"},{"key":"193_CR30","doi-asserted-by":"crossref","unstructured":"Stephens-Fripp B, Alici G, Mutlu R. A review of non-invasive sensory feedback methods for transradial prosthetic hands. Vol. 6, IEEE Access. 2018. p. 6878\u201399. Available from: https:\/\/ro.uow.edu.au\/eispapers1:https:\/\/ro.uow.edu.au\/eispapers1\/1181. Cited 2024 Jan 28.","DOI":"10.1109\/ACCESS.2018.2791583"},{"key":"193_CR31","doi-asserted-by":"crossref","unstructured":"Tang LJ, Wang MH, Tian HC, Kang XY, Hong W, Liu JQ. Progress in research of flexible MEMS microelectrodes for neural interface. Vol. 8, Micromachines. 2017. Available from: www.mdpi.com\/journal\/micromachines","DOI":"10.3390\/mi8090281"},{"issue":"2","key":"193_CR32","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1109\/TNSRE.2004.828415","volume":"12","author":"MD Tarler","year":"2004","unstructured":"Tarler MD, Mortimer JT. Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode. IEEE Trans Neural Syst Rehabil Eng. 2004;12(2):251\u20137.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"193_CR33","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1109\/86.559349","volume":"5","author":"DJ Tyler","year":"1997","unstructured":"Tyler DJ, Durand DM. A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves. IEEE Trans Rehabil Eng. 1997;5(1):51\u201361. Available from: https:\/\/pubmed.ncbi.nlm.nih.gov\/9086385\/. Cited 2024 Jan 16","journal-title":"IEEE Trans Rehabil Eng."},{"issue":"4","key":"193_CR34","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1109\/TNSRE.2002.806840","volume":"10","author":"DJ Tyler","year":"2002","unstructured":"Tyler DJ, Durand DM. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. IEEE Trans Neural Syst Rehabil Eng. 2002;10(4):294\u2013303.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"193_CR35","doi-asserted-by":"publisher","unstructured":"Won SM, Song E, Zhao J, Li J, Rivnay J, Rogers JA. Recent Advances in Materials, Devices, and Systems for Neural Interfaces. Vol. 30, Advanced Materials. Wiley-VCH Verlag; 2018. p. 1800534. Available from: https:\/\/onlinelibrary.wiley.com\/doi\/full\/https:\/\/doi.org\/10.1002\/adma.201800534 Cited 2025 May 12","DOI":"10.1002\/adma.201800534"},{"key":"193_CR36","doi-asserted-by":"crossref","unstructured":"Yang W, Gong Y, Li W. A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants. Vol. 8, Frontiers in Bioengineering and Biotechnology. Frontiers Media S.A.; 2021. p. 622923. Available from: www.frontiersin.org Cited 2025 May 12","DOI":"10.3389\/fbioe.2020.622923"},{"key":"193_CR37","doi-asserted-by":"crossref","unstructured":"Yoshida K, Kurstjens M, Citi L, Koch KP, Micera S. Recording experience with the thin-film longitudinal intra-fascicular electrode, a multichannel peripheral nerve interface. In: 2007 IEEE 10th International Conference on Rehabilitation Robotics, ICORR\u201907. 2007. p. 862\u20137.","DOI":"10.1109\/ICORR.2007.4428525"},{"key":"193_CR38","doi-asserted-by":"publisher","unstructured":"Yuan H, Silberstein SD. Vagus Nerve and Vagus Nerve Stimulation, a Comprehensive Review: Part i. Vol. 56, Headache. Blackwell Publishing Inc.; 2016. p. 71\u20138. Available from: https:\/\/headachejournal.onlinelibrary.wiley.com\/doi\/https:\/\/doi.org\/10.1111\/head.12647 Cited 2024 Jan 28","DOI":"10.1111\/head.12647"},{"key":"193_CR39","doi-asserted-by":"crossref","unstructured":"Zheng XS, Tan C, Castagnola E, Cui XT. Electrode Materials for Chronic Electrical Microstimulation. Vol. 10, Advanced Healthcare Materials. John Wiley and Sons Inc; 2021. p. e2100119. Available from: https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC8257249\/. Cited 2025 Aug 22","DOI":"10.1002\/adhm.202100119"}],"container-title":["Bioelectronic Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42234-025-00193-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42234-025-00193-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42234-025-00193-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T00:02:22Z","timestamp":1765324942000},"score":1,"resource":{"primary":{"URL":"https:\/\/bioelecmed.biomedcentral.com\/articles\/10.1186\/s42234-025-00193-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,10]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["193"],"URL":"https:\/\/doi.org\/10.1186\/s42234-025-00193-6","relation":{},"ISSN":["2332-8886"],"issn-type":[{"value":"2332-8886","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,10]]},"assertion":[{"value":"27 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No regulated procedures were carried out. Nerves were harvested from animals killed using an approved Schedule 1 method in accordance with the UK Animals (Scientific Procedures) Act 1986.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"29"}}