{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T21:57:57Z","timestamp":1787954277665,"version":"build-2784847793"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:00:00Z","timestamp":1772755200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":34,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100008678","name":"Universit\u00e4t Leipzig","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100008678","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC biomed eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Personalized 3D-printed bone models are becoming increasingly popular in clinical care. Common applications include the visualization of idiopathic deformities or complex joint fractures. Functionalizing such printed replicas in terms of individual mechanical properties holds great potential for clinical training and research but is challenging due to the complexity of the bone structure. This study aims at developing a parametrizable structure as a substitute for spongious bone by simplifying 3D reconstruction and printing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      43 vertebrae from 6 body donors aged 86.8\u2009\u00b1\u20097.8 years were examined. Each spine underwent a clinical computed tomography scan. Cylindrical samples (\u00d86\u2009\u00d7\u200912\u00a0mm) were randomly taken from the left or right side of the vertebral body using a core drill in the superior-inferior direction. Specific software was used for determining the volumetric Hounsfield units of the spongious bone in each vertebral hemisphere. In parallel, a parametric hexagonal grid structure was designed using engineering software. All rods within the lattice have a variable length L and a fixed diameter of t\u2009=\u20090.4\u00a0mm. By varying the ratio t\/L, six different porosities were defined. For each of these, five cylindrical lattice samples (diameter\/length\u2009=\u20091\/2) from two different synthetic resins were manufactured using the stereolithography printing process. All samples were mechanically characterized by uniaxial compressive testing. Curve fitting based on power functions (y\u2009=\u2009ax\n                      <jats:sup>b<\/jats:sup>\n                      ) allowed the determination of correlations between mechanical parameters and Hounsfield units (bone) as well as the lattice parameter t\/L (3D-printed lattice). Finally, three vertebrae with varying bone quality were printed with their respected parameterized lattice and evaluated by comparing the axial screw pullout forces of the human and the respective printed bones.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>There is a significant correlation between the mechanical properties of the bone specimens and the determined Hounsfield units. Furthermore, the mechanical properties of the lattice can be excellently described by the ratio t\/L. The printed vertebrae showed pull-out forces similar to those of osteoporotic bone.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conlusion<\/jats:title>\n                    <jats:p>The mechanical behavior of vertebral human spongious bone can be well reproduced by a 3D-printed generic lattice structure. Patient-specific bone models can be generated by integrating the parameterizable lattice structure into the specific bone contours. These models can help in improving patient care, for instance by enabling highly realistic surgical approaches for particularly complex anatomies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s42490-026-00107-w","type":"journal-article","created":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T10:23:53Z","timestamp":1772792633000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Biomechanical evaluation of individual 3D-printed vertebrae"],"prefix":"10.1186","volume":"8","author":[{"given":"Florian","family":"Metzner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Schleifenbaum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph-Eckhard","family":"Heyde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas Heinz","family":"von der H\u00f6h","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,6]]},"reference":[{"key":"107_CR1","doi-asserted-by":"publisher","first-page":"687379","DOI":"10.3389\/fsurg.2021.687379","volume":"8","author":"M Jiang","year":"2021","unstructured":"Jiang M, Coles-Black J, Chen G, Alexander M, Chuen J, Hardidge A. 3D Printed Patient-Specific Complex Hip Arthroplasty Models Streamline the Preoperative Surgical Workflow: A Pilot Study. Front Surg. 2021;8:687379. https:\/\/doi.org\/10.3389\/fsurg.2021.687379.","journal-title":"Front Surg"},{"key":"107_CR2","doi-asserted-by":"publisher","first-page":"e016891","DOI":"10.1136\/bmjopen-2017-016891","volume":"7","author":"LE Diment","year":"2017","unstructured":"Diment LE, Thompson MS, Bergmann JHM. Clinical efficacy and effectiveness of 3D printing: a systematic review. BMJ Open. 2017;7:e016891. https:\/\/doi.org\/10.1136\/bmjopen-2017-016891.","journal-title":"BMJ Open"},{"key":"107_CR3","doi-asserted-by":"publisher","first-page":"e582","DOI":"10.1097\/MD.0000000000000582","volume":"94","author":"M Yang","year":"2015","unstructured":"Yang M, Li C, Li Y, Zhao Y, Wei X, Zhang G, et al. Application of 3D rapid prototyping technology in posterior corrective surgery for Lenke 1 adolescent idiopathic scoliosis patients. Med (Baltim). 2015;94:e582. https:\/\/doi.org\/10.1097\/MD.0000000000000582.","journal-title":"Med (Baltim)"},{"key":"107_CR4","doi-asserted-by":"publisher","first-page":"57","DOI":"10.2147\/ORR.S99614","volume":"8","author":"KC Wong","year":"2016","unstructured":"Wong KC. 3D-printed patient-specific applications in orthopedics. Orthop Res Rev. 2016;8:57\u201366. https:\/\/doi.org\/10.2147\/ORR.S99614.","journal-title":"Orthop Res Rev"},{"key":"107_CR5","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s41205-020-00082-5","volume":"6","author":"M Meglioli","year":"2020","unstructured":"Meglioli M, Naveau A, Macaluso GM, Catros S. 3D printed bone models in oral and cranio-maxillofacial surgery: a systematic review. 3D Print Med. 2020;6:30. https:\/\/doi.org\/10.1186\/s41205-020-00082-5.","journal-title":"3D Print Med"},{"key":"107_CR6","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1007\/s00776-015-0706-8","volume":"20","author":"C Li","year":"2015","unstructured":"Li C, Yang M, Xie Y, Chen Z, Wang C, Bai Y, et al. Application of the polystyrene model made by 3-D printing rapid prototyping technology for operation planning in revision lumbar discectomy. J Orthop Sci. 2015;20:475\u201380. https:\/\/doi.org\/10.1007\/s00776-015-0706-8.","journal-title":"J Orthop Sci"},{"key":"107_CR7","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1007\/978-981-13-1396-7_27","volume":"1093","author":"H Cai","year":"2018","unstructured":"Cai H, Liu Z, Wei F, Yu M, Xu N, Li Z. 3D Printing in Spine Surgery. Adv Exp Med Biol. 2018;1093:345\u201359. https:\/\/doi.org\/10.1007\/978-981-13-1396-7_27.","journal-title":"Adv Exp Med Biol"},{"key":"107_CR8","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/SIH.0000000000000417","volume":"15","author":"P Stefan","year":"2020","unstructured":"Stefan P, Pfandler M, Lazarovici M, Weigl M, Navab N, Euler E, et al. Three-dimensional-Printed Computed Tomography-Based Bone Models for Spine Surgery Simulation. Simul Healthc. 2020;15:61\u20136. https:\/\/doi.org\/10.1097\/SIH.0000000000000417.","journal-title":"Simul Healthc"},{"key":"107_CR9","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.jos.2017.12.010","volume":"23","author":"JW Kim","year":"2018","unstructured":"Kim JW, Lee Y, Seo J, Park JH, Seo YM, Kim SS, Shon HC. Clinical experience with three-dimensional printing techniques in orthopedic trauma. J Orthop Sci. 2018;23:383\u20138. https:\/\/doi.org\/10.1016\/j.jos.2017.12.010.","journal-title":"J Orthop Sci"},{"key":"107_CR10","doi-asserted-by":"publisher","first-page":"6044","DOI":"10.1038\/s41598-020-63219-w","volume":"10","author":"S Shen","year":"2020","unstructured":"Shen S, Wang P, Li X, Han X, Tan H. Pre-operative simulation using a three-dimensional printing model for surgical treatment of old and complex tibial plateau fractures. Sci Rep. 2020;10:6044. https:\/\/doi.org\/10.1038\/s41598-020-63219-w.","journal-title":"Sci Rep"},{"key":"107_CR11","doi-asserted-by":"publisher","first-page":"2223","DOI":"10.1016\/j.injury.2016.03.015","volume":"47","author":"C Zeng","year":"2016","unstructured":"Zeng C, Xing W, Wu Z, Huang H, Huang W. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction. Injury. 2016;47:2223\u20137. https:\/\/doi.org\/10.1016\/j.injury.2016.03.015.","journal-title":"Injury"},{"key":"107_CR12","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1007\/s00068-018-0970-3","volume":"45","author":"L Brouwers","year":"2019","unstructured":"Brouwers L, Teutelink A, van Tilborg FAJB, de Jongh MAC, Lansink KWW, Bemelman M. Validation study of 3D-printed anatomical models using 2 PLA printers for preoperative planning in trauma surgery, a human cadaver study. Eur J Trauma Emerg Surg. 2019;45:1013\u201320. https:\/\/doi.org\/10.1007\/s00068-018-0970-3.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"107_CR13","doi-asserted-by":"publisher","first-page":"e392","DOI":"10.1097\/MAO.0000000000002524","volume":"41","author":"R Chae","year":"2020","unstructured":"Chae R, Sharon JD, Kournoutas I, Ovunc SS, Wang M, Abla AA, et al. Replicating Skull Base Anatomy With 3D Technologies: A Comparative Study Using 3D-scanned and 3D-printed Models of the Temporal Bone. Otol Neurotol. 2020;41:e392\u2013403. https:\/\/doi.org\/10.1097\/MAO.0000000000002524.","journal-title":"Otol Neurotol"},{"key":"107_CR14","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1177\/1120700018811553","volume":"29","author":"A Sallent","year":"2019","unstructured":"Sallent A, Seijas R, P\u00e9rez-Bellmunt A, Oliva E, Casasayas O, Escalona C, Ares O. Feasibility of 3D-printed models of the proximal femur to real bone: a cadaveric study. Hip Int. 2019;29:452\u20135. https:\/\/doi.org\/10.1177\/1120700018811553.","journal-title":"Hip Int"},{"key":"107_CR15","doi-asserted-by":"publisher","DOI":"10.1186\/s42490-022-00063-1","author":"F Metzner","year":"2022","unstructured":"Metzner F, Neupetsch C, Carabello A, Pietsch M, Wendler T, Drossel W-G. Biomechanical validation of additively manufactured artificial femoral bones. BMC biomed eng. 2022. https:\/\/doi.org\/10.1186\/s42490-022-00063-1.","journal-title":"BMC biomed eng"},{"key":"107_CR16","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.addma.2017.12.002","volume":"20","author":"JRC Dizon","year":"2018","unstructured":"Dizon JRC, Espera AH, Chen Q, Advincula RC. Mechanical characterization of 3D-printed polymers. Additive Manuf. 2018;20:44\u201367. https:\/\/doi.org\/10.1016\/j.addma.2017.12.002.","journal-title":"Additive Manuf"},{"key":"107_CR17","doi-asserted-by":"publisher","DOI":"10.1007\/s40964-021-00191-5","author":"C Silva","year":"2021","unstructured":"Silva C, Pais AI, Caldas G, Gouveia BPPA, Alves JL, Belinha J. Study on 3D printing of gyroid-based structures for superior structural behaviour. Prog Addit Manuf. 2021. https:\/\/doi.org\/10.1007\/s40964-021-00191-5.","journal-title":"Prog Addit Manuf"},{"key":"107_CR18","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1002\/ase.1730","volume":"11","author":"ML Smith","year":"2018","unstructured":"Smith ML, Jones JFX. Dual-extrusion 3D printing of anatomical models for education. Anat Sci Educ. 2018;11:65\u201372. https:\/\/doi.org\/10.1002\/ase.1730.","journal-title":"Anat Sci Educ"},{"key":"107_CR19","doi-asserted-by":"publisher","first-page":"798","DOI":"10.1007\/s00586-018-5847-y","volume":"28","author":"M Burkhard","year":"2019","unstructured":"Burkhard M, F\u00fcrnstahl P, Farshad M. Three-dimensionally printed vertebrae with different bone densities for surgical training. E Spine J. 2019;28:798\u2013806. https:\/\/doi.org\/10.1007\/s00586-018-5847-y.","journal-title":"E Spine J"},{"key":"107_CR20","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1093\/ons\/opz326","volume":"19","author":"MA Bohl","year":"2020","unstructured":"Bohl MA, McBryan S, Pais D, Chang SW, Turner JD, Nakaji P, Kakarla UK. The Living Spine Model: A Biomimetic Surgical Training and Education Tool. Oper Neurosurg (Hagerstown). 2020;19:98\u2013106. https:\/\/doi.org\/10.1093\/ons\/opz326.","journal-title":"Oper Neurosurg (Hagerstown)"},{"key":"107_CR21","doi-asserted-by":"publisher","DOI":"10.3390\/ma14133712","author":"A Grzeszczak","year":"2021","unstructured":"Grzeszczak A, Lewin S, Eriksson O, Kreuger J, Persson C. The Potential of Stereolithography for 3D Printing of Synthetic Trabecular Bone Structures. Mater (Basel). 2021. https:\/\/doi.org\/10.3390\/ma14133712.","journal-title":"Mater (Basel)"},{"key":"107_CR22","doi-asserted-by":"publisher","first-page":"103608","DOI":"10.1016\/j.jmbbm.2019.103608","volume":"103","author":"D Wu","year":"2020","unstructured":"Wu D, Spanou A, Diez-Escudero A, Persson C. 3D-printed PLA\/HA composite structures as synthetic trabecular bone: A feasibility study using fused deposition modeling. J Mech Behav Biomed Mater. 2020;103:103608. https:\/\/doi.org\/10.1016\/j.jmbbm.2019.103608.","journal-title":"J Mech Behav Biomed Mater"},{"key":"107_CR23","doi-asserted-by":"publisher","unstructured":"F04 Committee. Specification and test methods for metallic medical bone screws. west conshohocken. PA: ASTM International. https:\/\/doi.org\/10.1520\/F0543-13E01.","DOI":"10.1520\/F0543-13E01"},{"key":"107_CR24","doi-asserted-by":"publisher","first-page":"13284","DOI":"10.1038\/s41598-021-92685-z","volume":"11","author":"F Metzner","year":"2021","unstructured":"Metzner F, Neupetsch C, Fischer J-P, Drossel W-G, Heyde C-E, Schleifenbaum S. Influence of osteoporosis on the compressive properties of femoral cancellous bone and its dependence on various density parameters. Sci Rep. 2021;11:13284. https:\/\/doi.org\/10.1038\/s41598-021-92685-z.","journal-title":"Sci Rep"},{"key":"107_CR25","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1186\/s13018-022-03265-4","volume":"17","author":"F Wang","year":"2022","unstructured":"Wang F, Metzner F, Zheng L, Osterhoff G, Schleifenbaum S. Selected mechanical properties of human cancellous bone subjected to different treatments: short-term immersion in physiological saline and acetone treatment with subsequent immersion in physiological saline. J Orthop Surg Res. 2022;17:376. https:\/\/doi.org\/10.1186\/s13018-022-03265-4.","journal-title":"J Orthop Surg Res"},{"key":"107_CR26","doi-asserted-by":"publisher","first-page":"232","DOI":"10.21037\/jss-23-121","volume":"10","author":"F Metzner","year":"2024","unstructured":"Metzner F, Reise R, Heyde C-E, von der H\u00f6h NH, Schleifenbaum S. Side specific differences of Hounsfield-Units in the osteoporotic lumbar spine. J Spine Surg. 2024;10:232\u201343. https:\/\/doi.org\/10.21037\/jss-23-121.","journal-title":"J Spine Surg"},{"key":"107_CR27","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/0021-9290(85)90287-8","volume":"18","author":"LJ Gibson","year":"1985","unstructured":"Gibson LJ. The mechanical behaviour of cancellous bone. J Biomech. 1985;18:317\u201328. https:\/\/doi.org\/10.1016\/0021-9290(85)90287-8.","journal-title":"J Biomech"},{"key":"107_CR28","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/S8756-3282(99)00098-8","volume":"25","author":"D Ulrich","year":"1999","unstructured":"Ulrich D, van Rietbergen B, Laib A, R\u0308uegsegger P. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone. 1999;25:55\u201360. https:\/\/doi.org\/10.1016\/S8756-3282(99)00098-8.","journal-title":"Bone"},{"key":"107_CR29","doi-asserted-by":"publisher","first-page":"105866","DOI":"10.1016\/j.clinbiomech.2022.105866","volume":"101","author":"F Metzner","year":"2022","unstructured":"Metzner F, Fischer B, Heyde C-E, Schleifenbaum S. The effects of force application on the compressive properties of femoral spongious bone. Clin Biomech (Bristol Avon). 2022;101:105866. https:\/\/doi.org\/10.1016\/j.clinbiomech.2022.105866.","journal-title":"Clin Biomech (Bristol Avon)"},{"key":"107_CR30","doi-asserted-by":"publisher","unstructured":"DIN 50134. 2008-10, Pr\u00fcfung von metallischen Werkstoffen_Druckversuch an metallischen zellularen Werkstoffen. Berlin: Beuth Verlag GmbH. https:\/\/doi.org\/10.31030\/1443205.","DOI":"10.31030\/1443205"},{"key":"107_CR31","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1002\/jor.1100150115","volume":"15","author":"TM Keaveny","year":"1997","unstructured":"Keaveny TM, Pinilla TP, Crawford RP, Kopperdahl DL, Lou A. Systematic and random errors in compression testing of trabecular bone. J Orthop Res. 1997;15:101\u201310. https:\/\/doi.org\/10.1002\/jor.1100150115.","journal-title":"J Orthop Res"},{"key":"107_CR32","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1007\/s11926-018-0784-7","volume":"20","author":"L Lenchik","year":"2018","unstructured":"Lenchik L, Weaver AA, Ward RJ, Boone JM, Boutin RD. Opportunistic Screening for Osteoporosis Using Computed Tomography: State of the Art and Argument for Paradigm Shift. Curr Rheumatol Rep. 2018;20:74. https:\/\/doi.org\/10.1007\/s11926-018-0784-7.","journal-title":"Curr Rheumatol Rep"},{"key":"107_CR33","doi-asserted-by":"publisher","first-page":"100204","DOI":"10.1016\/j.xnsj.2023.100204","volume":"14","author":"A Ahmad","year":"2023","unstructured":"Ahmad A, Crawford CH, Glassman SD, Dimar JR, Gum JL, Carreon LY. Correlation between bone density measurements on CT or MRI versus DEXA scan: A systematic review. N Am Spine Soc J. 2023;14:100204. https:\/\/doi.org\/10.1016\/j.xnsj.2023.100204.","journal-title":"N Am Spine Soc J"},{"key":"107_CR34","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1097\/BRS.0000000000004211","volume":"47","author":"EM Pinto","year":"2022","unstructured":"Pinto EM, Neves JR, Teixeira A, Frada R, Atilano P, Oliveira F, et al. Efficacy of Hounsfield Units Measured by Lumbar Computer Tomography on Bone Density Assessment: A Systematic Review. Spine (Phila Pa 1976). 2022;47:702\u201310. https:\/\/doi.org\/10.1097\/BRS.0000000000004211.","journal-title":"Spine (Phila Pa 1976)"},{"key":"107_CR35","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1007\/s00113-019-0658-0","volume":"122","author":"MJ Scheyerer","year":"2019","unstructured":"Scheyerer MJ, Ullrich B, Osterhoff G, Spiegl UA, Schnake KJ. \u201eHounsfield units als Ma\u00df f\u00fcr die Knochendichte \u2013 Anwendungsm\u00f6glichkeiten in der Wirbels\u00e4ulenchirurgie. [Hounsfield units as a measure of bone density-applications in spine surgery]. Unfallchirurg. 2019;122:654\u201361. https:\/\/doi.org\/10.1007\/s00113-019-0658-0.","journal-title":"Unfallchirurg"},{"key":"107_CR36","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1177\/2192568219889362","volume":"10","author":"M Shirley","year":"2020","unstructured":"Shirley M, Wanderman N, Keaveny T, Anderson P, Freedman BA. Opportunistic Computed Tomography and Spine Surgery: A Narrative Review. Global Spine J. 2020;10:919\u201328. https:\/\/doi.org\/10.1177\/2192568219889362.","journal-title":"Global Spine J"},{"key":"107_CR37","doi-asserted-by":"publisher","first-page":"E239","DOI":"10.1097\/BRS.0000000000002813","volume":"44","author":"Q Zaidi","year":"2019","unstructured":"Zaidi Q, Danisa OA, Cheng W. Measurement Techniques and Utility of Hounsfield Unit Values for Assessment of Bone Quality Prior to Spinal Instrumentation: A Review of Current Literature. Spine (Phila Pa 1976). 2019;44:E239\u201344. https:\/\/doi.org\/10.1097\/BRS.0000000000002813.","journal-title":"Spine (Phila Pa 1976)"},{"key":"107_CR38","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1115\/1.2895536","volume":"115","author":"TM Keaveny","year":"1993","unstructured":"Keaveny TM, Hayes WC. A 20-year perspective on the mechanical properties of trabecular bone. J Biomech Eng. 1993;115:534\u201342. https:\/\/doi.org\/10.1115\/1.2895536.","journal-title":"J Biomech Eng"},{"key":"107_CR39","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1146\/annurev.bioeng.3.1.307","volume":"3","author":"TM Keaveny","year":"2001","unstructured":"Keaveny TM, Morgan EF, Niebur GL, Yeh OC. Biomechanics of trabecular bone. Annu Rev Biomed Eng. 2001;3:307\u201333. https:\/\/doi.org\/10.1146\/annurev.bioeng.3.1.307.","journal-title":"Annu Rev Biomed Eng"},{"key":"107_CR40","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1016\/0021-9290(93)90059-N","volume":"26","author":"TM Keaveny","year":"1993","unstructured":"Keaveny TM, Borchers RE, Gibson LJ, Hayes WC. Trabecular bone modulus and strength can depend on specimen geometry. J Biomech. 1993;26:991\u20131000. https:\/\/doi.org\/10.1016\/0021-9290(93)90059-N.","journal-title":"J Biomech"},{"key":"107_CR41","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1016\/0021-9290(94)90056-6","volume":"27","author":"TS Keller","year":"1994","unstructured":"Keller TS. Predicting the compressive mechanical behavior of bone. Memory Rik Huiskes. 1994;27:1159\u201368. https:\/\/doi.org\/10.1016\/0021-9290(94)90056-6.","journal-title":"Memory Rik Huiskes"},{"key":"107_CR42","doi-asserted-by":"publisher","first-page":"e1176","DOI":"10.1002\/jsp2.1176","volume":"4","author":"C \u00d6hman-M\u00e4gi","year":"2021","unstructured":"\u00d6hman-M\u00e4gi C, Holub O, Wu D, Hall RM, Persson C. Density and mechanical properties of vertebral trabecular bone-A review. JOR Spine. 2021;4:e1176. https:\/\/doi.org\/10.1002\/jsp2.1176.","journal-title":"JOR Spine"},{"key":"107_CR43","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1002\/jor.1100090507","volume":"9","author":"MJ Ciarelli","year":"1991","unstructured":"Ciarelli MJ, Goldstein SA, Kuhn JL, Cody DD, Brown MB. Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography. J Orthop Res. 1991;9:674\u201382. https:\/\/doi.org\/10.1002\/jor.1100090507.","journal-title":"J Orthop Res"},{"key":"107_CR44","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/0021-9290(75)90075-5","volume":"8","author":"DT Reilly","year":"1975","unstructured":"Reilly DT, Burstein AH. The elastic and ultimate properties of compact bone tissue. J Biomech. 1975;8:393\u2013405. https:\/\/doi.org\/10.1016\/0021-9290(75)90075-5.","journal-title":"J Biomech"},{"key":"107_CR45","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1098\/rsta.2005.1678","volume":"364","author":"MF Ashby","year":"2006","unstructured":"Ashby MF. The properties of foams and lattices. Philos Trans Math Phys Eng Sci. 2006;364:15\u201330. https:\/\/doi.org\/10.1098\/rsta.2005.1678.","journal-title":"Philos Trans Math Phys Eng Sci"},{"key":"107_CR46","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1097\/01.brs.0000261566.38422.40","volume":"32","author":"DJ Burval","year":"2007","unstructured":"Burval DJ, McLain RF, Milks R, Inceoglu S. Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine (Phila Pa 1976). 2007;32:1077\u201383. https:\/\/doi.org\/10.1097\/01.brs.0000261566.38422.40.","journal-title":"Spine (Phila Pa 1976)"},{"key":"107_CR47","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.clinbiomech.2010.10.008","volume":"26","author":"M Gao","year":"2011","unstructured":"Gao M, Lei W, Wu Z, Da Liu, Shi L. Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation. Clin Biomech (Bristol Avon). 2011;26:238\u201344. https:\/\/doi.org\/10.1016\/j.clinbiomech.2010.10.008.","journal-title":"Clin Biomech (Bristol Avon)"},{"key":"107_CR48","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1016\/j.spinee.2013.01.038","volume":"13","author":"H Koller","year":"2013","unstructured":"Koller H, Zenner J, Hitzl W, Resch H, Stephan D, Augat P, et al. The impact of a distal expansion mechanism added to a standard pedicle screw on pullout resistance. A biomechanical study. Spine J. 2013;13:532\u201341. https:\/\/doi.org\/10.1016\/j.spinee.2013.01.038.","journal-title":"Spine J"},{"key":"107_CR49","doi-asserted-by":"publisher","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","volume":"19","author":"TL Halvorson","year":"1994","unstructured":"Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS, Cook SD. Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976). 1994;19:2415\u201320. https:\/\/doi.org\/10.1097\/00007632-199411000-00008.","journal-title":"Spine (Phila Pa 1976)"},{"key":"107_CR50","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1097\/00007632-199111000-00015","volume":"16","author":"S Soshi","year":"1991","unstructured":"Soshi S, Shiba R, Kondo H, Murota K. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine (Phila Pa 1976). 1991;16:1335\u201341. https:\/\/doi.org\/10.1097\/00007632-199111000-00015.","journal-title":"Spine (Phila Pa 1976)"},{"key":"107_CR51","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1007\/s00701-017-3424-5","volume":"160","author":"K Matsukawa","year":"2018","unstructured":"Matsukawa K, Abe Y, Yanai Y, Yato Y. Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study. Acta Neurochir (Wien). 2018;160:405\u201311. https:\/\/doi.org\/10.1007\/s00701-017-3424-5.","journal-title":"Acta Neurochir (Wien)"},{"key":"107_CR52","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1007\/s00586-020-06386-8","volume":"29","author":"D Zou","year":"2020","unstructured":"Zou D, Sun Z, Zhou S, Zhong W, Li W. Hounsfield units value is a better predictor of pedicle screw loosening than the T-score of DXA in patients with lumbar degenerative diseases. E Spine J. 2020;29:1105\u201311. https:\/\/doi.org\/10.1007\/s00586-020-06386-8.","journal-title":"E Spine J"},{"key":"107_CR53","doi-asserted-by":"publisher","first-page":"1714","DOI":"10.1007\/s00330-014-3529-7","volume":"25","author":"JL Wichmann","year":"2015","unstructured":"Wichmann JL, Booz C, Wesarg S, Bauer RW, Kerl JM, Fischer S, et al. Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength. Eur Radiol. 2015;25:1714\u201320. https:\/\/doi.org\/10.1007\/s00330-014-3529-7.","journal-title":"Eur Radiol"},{"key":"107_CR54","doi-asserted-by":"publisher","first-page":"2504","DOI":"10.1097\/00007632-199711010-00007","volume":"22","author":"T Hirano","year":"1997","unstructured":"Hirano T, Hasegawa K, Takahashi HE, Uchiyama S, Hara T, Washio T, et al. Structural characteristics of the pedicle and its role in screw stability. Spine (Phila Pa 1976). 1997;22:2504\u20139. https:\/\/doi.org\/10.1097\/00007632-199711010-00007. discussion 2510.","journal-title":"Spine (Phila Pa 1976)"},{"key":"107_CR55","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1302\/0301-620X.92B8.24237","volume":"92","author":"W Cho","year":"2010","unstructured":"Cho W, Cho SK, Wu C. The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg Br. 2010;92:1061\u20135. https:\/\/doi.org\/10.1302\/0301-620X.92B8.24237.","journal-title":"J Bone Joint Surg Br"},{"key":"107_CR56","doi-asserted-by":"crossref","unstructured":"Carter, Hayes WC. The compressive behavior of bone as a two-phase porous structure. JBJS. 1977;59.","DOI":"10.2106\/00004623-197759070-00021"},{"key":"107_CR57","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1186\/s12891-021-04571-4","volume":"22","author":"D Gehweiler","year":"2021","unstructured":"Gehweiler D, Schultz M, Schulze M, Riesenbeck O, W\u00e4hnert D, Raschke MJ. Material properties of human vertebral trabecular bone under compression can be predicted based on quantitative computed tomography. BMC Musculoskelet Disord. 2021;22:709. https:\/\/doi.org\/10.1186\/s12891-021-04571-4.","journal-title":"BMC Musculoskelet Disord"}],"container-title":["BMC Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42490-026-00107-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42490-026-00107-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42490-026-00107-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T19:29:48Z","timestamp":1781638188000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s42490-026-00107-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,6]]},"references-count":57,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["107"],"URL":"https:\/\/doi.org\/10.1186\/s42490-026-00107-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-7710013\/v1","asserted-by":"object"}]},"ISSN":["2524-4426"],"issn-type":[{"value":"2524-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,6]]},"assertion":[{"value":"25 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. All body donors gave their informed and written consent to the donation of their bodies for teaching and research purposes while alive. Being part of the body donor program regulated by the Saxonian Death and Funeral Act of 1994 (third section, paragraph 18 item 8), institutional approval for the use of the post-mortem tissues of human body donors was obtained from the Institute of Anatomy (University of Leipzig) by the Ethics Committee of the University of Leipzig Medical Center (ethical approval No. 129\/21-ck). The authors declare that all experiments were conducted according to the principles of the Declaration of Helsinki (as revised in 2013).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5"}}