{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T14:22:20Z","timestamp":1791555740079,"version":"4.3.4"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Medical Research Council","award":["MR\/R025266\/1"],"award-info":[{"award-number":["MR\/R025266\/1"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC biomed eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Cuffed tracheal tubes enable a secure airway during mechanical ventilation; however, improper cuff inflation can lead to complications such as inspiratory gas leaks, pulmonary ingress of orogastric secretions, or tracheal injury. This study explores a sensor-based approach to optimise cuff inflation using fibre Bragg grating (FBG) optical sensors embedded within the cuff to detect contact with the tracheal wall. Testing was conducted on multiple trachea models, including cylindrical and bio-inspired models, as well as ex vivo porcine trachea samples, to assess cuff\u2013trachea contact. Seal performance was evaluated at both standard inflation pressures and contact-guided inflation pressures. The contact-sensing tracheal tube successfully detected cuff\u2013trachea contact in all models and ex vivo samples tested. Seal tests showed that larger diameter tracheal models exhibited lower leakage rates at contact-guided inflation pressures compared with standard inflation, indicating improved sealing. In contrast, smaller diameter models showed higher leakage rates at contact-guided pressures due to cuff folding, which formed leakage pathways. These results demonstrate that contact sensing improved cuff performance in larger tracheal models by enhancing sealing effectiveness. The contact-sensing tracheal tube differentiated tracheal model sizes, indicating potential for personalised cuff inflation to accommodate variations in tracheal size and shape. Future work will focus on further sensor miniaturisation and integration within lower-volume cuffs to enable effective contact sensing across a wider range of tracheal geometries and support translation to in vivo use.<\/jats:p>","DOI":"10.1186\/s42490-026-00113-y","type":"journal-article","created":{"date-parts":[[2026,5,31]],"date-time":"2026-05-31T22:01:56Z","timestamp":1780264916000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Bench testing a contact sensing tracheal tube for monitoring the cuff\u2013trachea interface"],"prefix":"10.1186","volume":"8","author":[{"given":"Tamaralayefa B.","family":"Agbiki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandor","family":"Erdody","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricardo","family":"Correia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergiy","family":"Korposh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David W.","family":"Hewson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew M.","family":"Norris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barrie R.","family":"Hayes-Gill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen P.","family":"Morgan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,1]]},"reference":[{"key":"113_CR1","unstructured":"Royal College of Anaesthetists and The Difficult Airway Society. Major complications of airway management in the United Kingdom: Report and findings. 4 ed. th National Audit Project; 2011;8."},{"key":"113_CR2","unstructured":"Sandberg W, Urman R, Ehrenfeld J. The MGH Textbook of anesthetic equipment E-Book. Elsevier; 2010. pp. 111\u201321."},{"key":"113_CR3","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1164\/ajrccm.165.7.2105078","volume":"165","author":"J Chastre","year":"2002","unstructured":"Chastre J, Fagon J-Y. Ventilator-associated pneumonia. Am J Respir Crit Care Med. 2002;165:867\u2013903. https:\/\/doi.org\/10.1164\/ajrccm.165.7.2105078.","journal-title":"Am J Respir Crit Care Med"},{"key":"113_CR4","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/EJA.0b013e3283222b6e","volume":"26","author":"S Nseir","year":"2009","unstructured":"Nseir S, Brisson H, Marquette C-H, Chaud P, Di Pompeo C, Diarra M, Durocher A. Variations in endotracheal cuff pressure in intubated critically ill patients: prevalence and risk factors. Eur J Anaesthesiol. 2009;26:229\u201334. https:\/\/doi.org\/10.1097\/EJA.0b013e3283222b6e.","journal-title":"Eur J Anaesthesiol"},{"issue":"2","key":"113_CR5","first-page":"139","volume":"28","author":"J Deslauriers","year":"2018","unstructured":"Deslauriers J, Shamji FM, Nelems B. Fundamentals of airway surgery, Part I, An issue of Thoracic Surgery Clinics. Elsevier Health Sci. 2018;28(2):139\u201344.","journal-title":"Elsevier Health Sci"},{"key":"113_CR6","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1097\/MCC.0b013e3283636b71","volume":"19","author":"R Anahita","year":"2013","unstructured":"Anahita R, Nseir S. Continuous control of tracheal cuff pressure for the prevention of ventilator-associated pneumonia in critically ill patients: where is the evidence? Curr Opin Crit Care. 2013;19:440\u20137. https:\/\/doi.org\/10.1097\/MCC.0b013e3283636b71.","journal-title":"Curr Opin Crit Care"},{"key":"113_CR7","doi-asserted-by":"publisher","first-page":"965","DOI":"10.1136\/bmj.288.6422.965","volume":"288","author":"RD Seegobin","year":"1984","unstructured":"Seegobin RD, Van Hasselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J (Clin Res Ed). 1984;288:965\u201388. https:\/\/doi.org\/10.1136\/bmj.288.6422.965.","journal-title":"Br Med J (Clin Res Ed)"},{"key":"113_CR8","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1007\/s00134-012-2750-6","volume":"39","author":"L Touat","year":"2013","unstructured":"Touat L, Fournier C, Ramon P, Salleron J, Durocher A, Nseir S. Intubation-related tracheal ischemic lesions: incidence, risk factors, and outcome. Intensive Care Med. 2013;39:575\u201382. https:\/\/doi.org\/10.1007\/s00134-012-2750-6.","journal-title":"Intensive Care Med"},{"key":"113_CR9","first-page":"625","volume":"80","author":"KL Yang","year":"1995","unstructured":"Yang KL. Tracheal stenosis after a brief intubation. Anesth Analg. 1995;80:625\u20137.","journal-title":"Anesth Analg"},{"key":"113_CR10","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1288\/00005537-197703000-00006","volume":"87","author":"DB Hawkins","year":"1977","unstructured":"Hawkins DB. Glottic and subglottic stenosis from endotracheal intubation. Laryngoscope. 1977;87:339\u201346. https:\/\/doi.org\/10.1288\/00005537-197703000-00006.","journal-title":"Laryngoscope"},{"key":"113_CR11","doi-asserted-by":"publisher","first-page":"e92","DOI":"10.1093\/ejcts\/ezu483","volume":"47","author":"S Gopal","year":"2015","unstructured":"Gopal S, Luckraz H, Giri R, Nevill A, Muhammed I, Reid M, Bickerton S, Jenkins D. Significant reduction in ventilator-associated pneumonia with the Venner-PneuX system in high-risk patients undergoing cardiac surgery: the Low Ventilator-Associated-Pneumonia study. Eur J Cardiothorac Surg. 2015;47:e92\u20136. https:\/\/doi.org\/10.1093\/ejcts\/ezu483.","journal-title":"Eur J Cardiothorac Surg"},{"key":"113_CR12","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.accpm.2020.04.007","volume":"39","author":"JE Dauvergne","year":"2020","unstructured":"Dauvergne JE, Geffray A, Asehnoune K, Rozec B, Lakhal K. Automatic regulation of the endotracheal tube cuff pressure with a portable elastomeric device: A randomised controlled study. Anaesth Crit Care Pain Med. 2020;39:435\u201341. https:\/\/doi.org\/10.1016\/j.accpm.2020.04.007.","journal-title":"Anaesth Crit Care Pain Med"},{"key":"113_CR13","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s10877-013-9513-y","volume":"28","author":"P Goethals","year":"2014","unstructured":"Goethals P, Chaobal H, Reynaerts D, Schaner D. A novel airway device with contact sensing capabilities for verifying correct endotracheal tube placement. J Clin Monit Comput. 2014;28:179\u201385. https:\/\/doi.org\/10.1007\/s10877-013-9513-y.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"113_CR14","doi-asserted-by":"publisher","first-page":"e10116","DOI":"10.1002\/mds3.10116","volume":"3","author":"J Vishnu","year":"2020","unstructured":"Vishnu J, Manivasagam G. Perspectives on smart stents with sensors: From conventional permanent to novel bioabsorbable smart stent technologies. Med Dev Sens. 2020;3(6):e10116. https:\/\/doi.org\/10.1002\/mds3.10116.","journal-title":"Med Dev Sens"},{"issue":"18","key":"113_CR15","doi-asserted-by":"publisher","first-page":"5446","DOI":"10.3390\/s20185446","volume":"20","author":"E Vanegas","year":"2020","unstructured":"Vanegas E, Igual R, Plaza I. Sensing systems for respiration monitoring: A technical systematic review. Sensors. 2020;20(18):5446. https:\/\/doi.org\/10.3390\/s20185446.","journal-title":"Sensors"},{"key":"113_CR16","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1364\/BOE.442165","volume":"13","author":"R Correia","year":"2021","unstructured":"Correia R, Gadsby B, Korposh S, Norris AM, Hayes-Gill BR, Sinha R, Hardman JG, Gardner DS, Talbot S, Harvey D, McGlashan J, Morgan SP. Intra-tracheal multiplexed sensing of contact pressure and perfusion. Biomed Opt Express. 2021;13:48\u201364. https:\/\/doi.org\/10.1364\/BOE.442165.","journal-title":"Biomed Opt Express"},{"key":"113_CR17","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1164\/rccm.200405-644ST","volume":"171","author":"American Thoracic Society; Infectious Diseases Society of America","year":"2005","unstructured":"American Thoracic Society; Infectious Diseases Society of America. Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia. Am J Respir Crit Care Med. 2005;171:388\u2013416. https:\/\/doi.org\/10.1164\/rccm.200405-644ST.","journal-title":"Am J Respir Crit Care Med"},{"key":"113_CR18","doi-asserted-by":"publisher","first-page":"1193","DOI":"10.1183\/09031936.00048507","volume":"30","author":"L Lorente","year":"2007","unstructured":"Lorente L, Blot S, Rello J. Evidence on measures for the prevention of ventilator associated pneumonia. Eur Respir J. 2007;30:1193\u2013207. https:\/\/doi.org\/10.1183\/09031936.00048507.","journal-title":"Eur Respir J"},{"key":"113_CR19","doi-asserted-by":"publisher","first-page":"106357","DOI":"10.1016\/j.optlastec.2020.106357","volume":"130","author":"G Woyessa","year":"2020","unstructured":"Woyessa G, Pedersen JK, Nielsen K, Bang O. Enhanced pressure and thermal sensitivity of polymer optical fiber Bragg grating sensors. Opt Lasers Technol. 2020;130:106357. https:\/\/doi.org\/10.1016\/j.optlastec.2020.106357.","journal-title":"Opt Lasers Technol"},{"key":"113_CR20","doi-asserted-by":"publisher","first-page":"103183","DOI":"10.1016\/j.yofte.2022.103183","volume":"75","author":"Z Jia","year":"2023","unstructured":"Jia Z, Dang S, Yu D, Fan W. Cantilever vibration sensor based on fiber Bragg grating temperature compensation. Opt Fiber Technol. 2023;75:103183. https:\/\/doi.org\/10.1016\/j.yofte.2022.103183.","journal-title":"Opt Fiber Technol"},{"key":"113_CR21","doi-asserted-by":"publisher","first-page":"100290","DOI":"10.1016\/j.bjao.2024.100290","volume":"10","author":"T Agbiki","year":"2024","unstructured":"Agbiki T, Arm R, Hewson DW, Erdody S, Norris AM, Correia R, Korposh S, Hayes-Gill BR, Shahidi A, Morgan SP. Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube tracheal seal testing. Br J Anaesth Open. 2024;10:100290. https:\/\/doi.org\/10.1016\/j.bjao.2024.100290.","journal-title":"Br J Anaesth Open"},{"issue":"3","key":"113_CR22","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1165\/rcmb.2013-0453TR","volume":"51","author":"EP Judge","year":"2014","unstructured":"Judge EP, Hughes JML, Egan JJ, Maguire M, Molloy EL, O\u2019Dea S. Anatomy and bronchoscopy of the porcine lung: A model for translational respiratory medicine. Am J Respir Cell Mol Biol. 2014;51(3):334\u201343. https:\/\/doi.org\/10.1165\/rcmb.2013-0453TR.","journal-title":"Am J Respir Cell Mol Biol"},{"issue":"4","key":"113_CR23","doi-asserted-by":"publisher","first-page":"1718","DOI":"10.21873\/invivo.12884","volume":"36","author":"MN Han","year":"2022","unstructured":"Han MN, Kim HY, Choi SH. Evaluation of biomechanical properties and morphometric structures of the trachea in pigs and rabbits. Vivo. 2022;36(4):1718\u201325. https:\/\/doi.org\/10.21873\/invivo.12884.","journal-title":"Vivo"},{"key":"113_CR24","doi-asserted-by":"publisher","unstructured":"Morey WW, Meltz G, Glenn WH. Fiber optic Bragg grating sensors. Proc SPIE 1169: Fiber Optic and Laser Sensors VII. 1990. https:\/\/doi.org\/10.1117\/12.963022.","DOI":"10.1117\/12.963022"},{"key":"113_CR25","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.sna.2016.04.033","volume":"244","author":"C Hong","year":"2016","unstructured":"Hong C, Zhang Y, Zhang M, Gordon LL, Liu L. Application of FBG sensors for geotechnical health monitoring: a review of sensor design, implementation methods and packaging techniques. Sens Actuators Phys. 2016;244:184\u201397. https:\/\/doi.org\/10.1016\/j.sna.2016.04.033.","journal-title":"Sens Actuators Phys"},{"key":"113_CR26","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.jmst.2019.11.010","volume":"43","author":"W Chen","year":"2020","unstructured":"Chen W, Yan X. Progress in achieving high-performance piezoresistive and capacitive flexible pressure sensors: A review. J Mater Sci Technol. 2020;43:175\u201388. https:\/\/doi.org\/10.1016\/j.jmst.2019.11.010.","journal-title":"J Mater Sci Technol"},{"key":"113_CR27","unstructured":"Avnet Abacus. Pressure sensors: The design engineer\u2019s guide. 2020. Available at: https:\/\/www.avnet.com\/wps\/portal\/abacus\/solutions\/technologies\/sensors\/pressure-sensors\/. Accessed 15 March 2026."},{"issue":"2","key":"113_CR28","doi-asserted-by":"publisher","first-page":"1898","DOI":"10.3390\/s120201898","volume":"12","author":"SJ Mihailov","year":"2012","unstructured":"Mihailov SJ. Fiber Bragg Grating Sensors for Harsh Environments. Sensors. 2012;12(2):1898\u2013918. https:\/\/doi.org\/10.3390\/s120201898.","journal-title":"Sensors"},{"issue":"7","key":"113_CR29","doi-asserted-by":"publisher","first-page":"2289","DOI":"10.3390\/s25072289","volume":"25","author":"AND Alhussein","year":"2025","unstructured":"Alhussein AND, Qaid MRTM, Agliullin T, Valeev B, Morozov O, Sakhabutdinov A. Fiber Bragg Grating Sensors: Design, Applications, and Comparison with Other Sensing Technologies. Sensors. 2025;25(7):2289. https:\/\/doi.org\/10.3390\/s25072289.","journal-title":"Sensors"},{"issue":"5","key":"113_CR30","doi-asserted-by":"publisher","first-page":"903","DOI":"10.2214\/ajr.142.5.903","volume":"142","author":"E Breatnach","year":"1984","unstructured":"Breatnach E, Abbott GC, Fraser RG. Dimensions of the normal human trachea. AJR Am J Roentgenol. 1984;142(5):903\u20136. https:\/\/doi.org\/10.2214\/ajr.142.5.903.","journal-title":"AJR Am J Roentgenol"},{"issue":"11","key":"113_CR31","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.1111\/anae.15041","volume":"75","author":"S Karmali","year":"2020","unstructured":"Karmali S, Rose P. Tracheal tube size in adults undergoing elective surgery: A narrative review. Anaesthesia. 2020;75(11):1529\u201339. https:\/\/doi.org\/10.1111\/anae.15041.","journal-title":"Anaesthesia"},{"key":"113_CR32","doi-asserted-by":"publisher","unstructured":"Koka R, Philip JH. Understanding anesthesia equipment, 5th edition. Anesth Analg. 2008;107:2098. https:\/\/doi.org\/10.1213\/ANE.0b013e3181911e29.","DOI":"10.1213\/ANE.0b013e3181911e29"},{"key":"113_CR33","unstructured":"Ahmed RA, Boyer TJ. Endotracheal Tube. In: StatPearls. StatPearls Publishing. Available via NCBI Bookshelf. 2024. https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK539747\/. Accessed 22 March 2025."},{"key":"113_CR34","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1007\/s00134-008-1016-9","volume":"34","author":"A Zanella","year":"2008","unstructured":"Zanella A, Cressoni M, Epp M, Stylianou M, Kolobow T. A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study. Intensive Care Med. 2008;34:1145\u20139. https:\/\/doi.org\/10.1007\/s00134-008-1016-9.","journal-title":"Intensive Care Med"}],"container-title":["BMC Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42490-026-00113-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42490-026-00113-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42490-026-00113-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,31]],"date-time":"2026-05-31T22:01:58Z","timestamp":1780264918000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s42490-026-00113-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,1]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["113"],"URL":"https:\/\/doi.org\/10.1186\/s42490-026-00113-y","relation":{},"ISSN":["2524-4426"],"issn-type":[{"value":"2524-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,1]]},"assertion":[{"value":"10 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declaration"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors have given their consent for the publication of this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10"}}