{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T14:56:12Z","timestamp":1760885772563},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T00:00:00Z","timestamp":1581033600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T00:00:00Z","timestamp":1581033600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Frontier and Key Technologies Innovation Funding Project of Department of Science and Technology of Guangdong Province","award":["2015B020225007"],"award-info":[{"award-number":["2015B020225007"]}]},{"name":"National Natural Science Foundation of China Grant Awards","award":["81802222"],"award-info":[{"award-number":["81802222"]}]},{"name":"the Natural Science Foundation of Guangdong Province","award":["2018A030310694"],"award-info":[{"award-number":["2018A030310694"]}]},{"name":"Project of Administration of Traditional Chinese Medicine of Guangdong Province","award":["20191004"],"award-info":[{"award-number":["20191004"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arthroplasty"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Strength deficits, muscle imbalances, and quadriceps inhibition are common after the total knee arthroplasty (TKA). It was suggested that theoretically single radius (SR) femoral protheses could provide longer extensor moment arm compared to the multiple radius (MR) design. However, quantitative evidence has not yet been reported. Thus, the aim of the study was to investigate the differences in isokinetic data and to compare the patient-reported outcome scores between TKA SR and MR design.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Method<\/jats:title>\n<jats:p>The present retrospective study included 36 TKA involving 16 knees (9 patients) using SR design implant and 20 knees (11 patients) using MR design implant. The mean follow-up time was longer than 1\u2009year. Isokinetic knee flexion and extension torques of the operated leg were evaluated at 60\u00b0\/s and 180\u00b0\/s. Quadriceps and hamstring torques and ratios, work and power were recorded. Angle-specific torques were also collected at different extension or flexion angles.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>Both groups showed improvement in knee society scores (KSS) and knee injury, and osteoarthritis outcome score (KOOS) after operation. Patients in SR group had significantly higher scores in KSS-knee, symptoms and activities of daily living KOOS sub-score than those in the MR group at the end of the follow-up. The peak knee flexion torque, peak knee extension torque and maximum knee flexion work were greater in SR group at 180\u00b0\/s and 60\u00b0\/s. At 60\u00b0\/s, and SR group had higher average knee flexion power and average knee extension power than MR group. In the isometric contraction test, the knee extension torque was higher in SR group than in MR group. At 180\u00b0\/s, SR group showed higher flexion torques at 30\u00b0, 40\u00b0, 50\u00b0, 60\u00b0 compared with MR group. At 60\u00b0\/s, SR group showed higher flexion torques at 30\u00b0, 40\u00b0, 50\u00b0, 60\u00b0, 80\u00b0 when compared with MR group. Additionally, SR group also provided higher extension torques at 40\u00b0, 50\u00b0, 60\u00b0 than the MR group. There were no differences in other isokinetic and isometric parameters between the two groups.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>Femoral design exerted an influence on quadriceps and hamstring strength after TKA, and SR design shows advantages, in terms of higher extension and flexion strength, over MR design.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s42836-020-0022-4","type":"journal-article","created":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T00:06:38Z","timestamp":1581033998000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Better quadriceps and hamstring strength is achieved after Total knee Arthroplasty with single radius femoral prostheses: a retrospective study based on isokinetic and isometric data"],"prefix":"10.1186","volume":"2","author":[{"given":"Mengyuan","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruiying","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuanchen","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junxing","family":"Liao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qingtian","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhantao","family":"Deng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiujian","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,2,7]]},"reference":[{"key":"22_CR1","volume-title":"14th Annual Report 2017","author":"National Joint Registry for England WaNI","year":"2017","unstructured":"National Joint Registry for England WaNI. 14th Annual Report 2017. 2017."},{"key":"22_CR2","volume-title":"Annual report","author":"SKA Register","year":"2017","unstructured":"Register SKA. Annual report; 2017."},{"key":"22_CR3","volume-title":"Fourth AJRR annual report on hip and knee arthroplasty data","author":"AJR Registry","year":"2017","unstructured":"Registry AJR. Fourth AJRR annual report on hip and knee arthroplasty data; 2017."},{"key":"22_CR4","volume-title":"Hip, knee and shoulder arthroplasty annual report","author":"AOANJR Registry","year":"2017","unstructured":"Registry AOANJR. Hip, knee and shoulder arthroplasty annual report; 2017."},{"issue":"3","key":"22_CR5","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/S0883-5403(97)90019-X","volume":"12","author":"TP Andriacchi","year":"1997","unstructured":"Andriacchi TP, Yoder D, Conley A, et al. Patellofemoral design influences function following total knee arthroplasty. J Arthroplast. 1997;12(3):243\u20139.","journal-title":"J Arthroplast"},{"issue":"9823","key":"22_CR6","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1016\/S0140-6736(11)60752-6","volume":"379","author":"AJ Carr","year":"2012","unstructured":"Carr AJ, Robertsson O, Graves S, et al. Knee replacement. Lancet. 2012;379(9823):1331\u201340.","journal-title":"Lancet."},{"issue":"5","key":"22_CR7","doi-asserted-by":"publisher","first-page":"945","DOI":"10.2106\/00004623-197153050-00010","volume":"53","author":"VH Frankel","year":"1971","unstructured":"Frankel VH, Burstein AH, Brooks DB. Biomechanics of internal derangement of the knee. Pathomechanics as determined by analysis of the instant centers of motion. J Bone Joint Surg Am. 1971;53(5):945\u201362.","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"22_CR8","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1054\/arth.2002.32168","volume":"17","author":"OM Mahoney","year":"2002","unstructured":"Mahoney OM, McClung CD. dela Rosa MA, et al. the effect of total knee arthroplasty design on extensor mechanism function. J Arthroplast. 2002;17(4):416\u201321.","journal-title":"J Arthroplast"},{"issue":"1","key":"22_CR9","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.clinbiomech.2006.07.011","volume":"22","author":"O Kessler","year":"2007","unstructured":"Kessler O, Durselen L, Banks S, et al. Sagittal curvature of total knee replacements predicts in vivo kinematics. Clin Biomech (Bristol, Avon). 2007;22(1):52\u20138.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"12","key":"22_CR10","doi-asserted-by":"publisher","first-page":"2764","DOI":"10.1007\/s00167-012-2178-0","volume":"21","author":"JY Jenny","year":"2013","unstructured":"Jenny JY, Miehlke R, Saragaglia D, et al. Single-radius, multidirectional total knee replacement. Knee Surg Sports Traumatol. 2013;21(12):2764\u20139.","journal-title":"Knee Surg Sports Traumatol"},{"issue":"6","key":"22_CR11","doi-asserted-by":"publisher","first-page":"527","DOI":"10.3233\/THC-2012-0698","volume":"20","author":"M Ezechieli","year":"2012","unstructured":"Ezechieli M, Dietzek J, Becher C, et al. The influence of a single-radius-design on the knee stability. Technol Health Care. 2012;20(6):527\u201334.","journal-title":"Technol Health Care"},{"issue":"8","key":"22_CR12","doi-asserted-by":"publisher","first-page":"1193","DOI":"10.1016\/j.arth.2006.02.172","volume":"21","author":"H Wang","year":"2006","unstructured":"Wang H, Simpson KJ, Ferrara MS, et al. Biomechanical differences exhibited during sit-to-stand between total knee arthroplasty designs of varying radii. J Arthroplast. 2006;21(8):1193\u20139.","journal-title":"J Arthroplast"},{"issue":"1","key":"22_CR13","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1002\/jor.22170","volume":"31","author":"JE Stoddard","year":"2013","unstructured":"Stoddard JE, Deehan DJ, Bull AM, et al. The kinematics and stability of single-radius versus multi-radius femoral components related to mid-range instability after TKA. J Orthopaedic Res. 2013;31(1):53\u20138.","journal-title":"J Orthopaedic Res"},{"issue":"2","key":"22_CR14","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/j.arth.2007.04.001","volume":"23","author":"J Hall","year":"2008","unstructured":"Hall J, Copp SN, Adelson WS, et al. Extensor mechanism function in single-radius vs multiradius femoral components for total knee arthroplasty. J Arthroplast. 2008;23(2):216\u20139.","journal-title":"J Arthroplast"},{"issue":"3","key":"22_CR15","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1055\/s-0031-1299660","volume":"25","author":"LE Cook","year":"2012","unstructured":"Cook LE, Klika AK, Szubski CR, et al. Functional outcomes used to compare single radius and multiradius of curvature designs in total knee arthroplasty. J Knee Surg. 2012;25(3):249\u201353.","journal-title":"J Knee Surg"},{"issue":"1","key":"22_CR16","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1302\/0301-620X.97B1.34254","volume":"97-b","author":"DF Hamilton","year":"2015","unstructured":"Hamilton DF, Burnett R, Patton JT, et al. Implant design influences patient outcome after total knee arthroplasty: a prospective double-blind randomised controlled trial. Bone Joint J. 2015;97-b(1):64\u201370.","journal-title":"Bone Joint J"},{"issue":"6","key":"22_CR17","doi-asserted-by":"publisher","first-page":"1062","DOI":"10.1016\/j.arth.2015.01.014","volume":"30","author":"B Larsen","year":"2015","unstructured":"Larsen B, Jacofsky MC, Jacofsky DJ. Quantitative, comparative assessment of gait between single-radius and multi-radius Total knee Arthroplasty designs. J Arthroplast. 2015;30(6):1062\u20137.","journal-title":"J Arthroplast"},{"issue":"11","key":"22_CR18","doi-asserted-by":"publisher","first-page":"3508","DOI":"10.1007\/s00167-016-4273-0","volume":"25","author":"I Collados-Maestre","year":"2017","unstructured":"Collados-Maestre I, Lizaur-Utrilla A, Gonzalez-Navarro B, et al. Better functional outcome after single-radius TKA compared with multi-radius TKA. Knee Surg Sports Traumatol Arthroscopy. 2017;25(11):3508\u201314.","journal-title":"Knee Surg Sports Traumatol Arthroscopy"},{"issue":"4","key":"22_CR19","doi-asserted-by":"publisher","first-page":"240","DOI":"10.5792\/ksrr.2015.27.4.240","volume":"27","author":"DH Kim","year":"2015","unstructured":"Kim DH, Kim DK, Lee SH, et al. Is single-radius design better for quadriceps recovery in Total knee Arthroplasty? Knee Surg Relat Res. 2015;27(4):240\u20136.","journal-title":"Knee Surg Relat Res"},{"issue":"3","key":"22_CR20","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1016\/j.arth.2015.10.017","volume":"31","author":"S Liu","year":"2016","unstructured":"Liu S, Long H, Zhang Y, et al. Meta-analysis of outcomes of a single-radius versus multi-radius femoral Design in Total Knee Arthroplasty. J Arthroplast. 2016;31(3):646\u201354.","journal-title":"J Arthroplast"},{"issue":"5","key":"22_CR21","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1007\/s11999-009-1190-2","volume":"468","author":"E Gomez-Barrena","year":"2010","unstructured":"Gomez-Barrena E, Fernandez-Garcia C, Fernandez-Bravo A, et al. Functional performance with a single-radius femoral design total knee arthroplasty. Clin Orthop Relat Res. 2010;468(5):1214\u201320.","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"22_CR22","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1007\/s00264-014-2307-0","volume":"38","author":"J Palmer","year":"2014","unstructured":"Palmer J, Sloan K, Clark G. Functional outcomes comparing triathlon versus Duracon total knee arthroplasty: does the triathlon outperform its predecessor? Int Orthop. 2014;38(7):1375\u20138.","journal-title":"Int Orthop"},{"key":"22_CR23","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/00003086-200111000-00026","volume":"392","author":"DD D'Lima","year":"2001","unstructured":"D'Lima DD, Poole C, Chadha H, et al. Quadriceps moment arm and quadriceps forces after total knee arthroplasty. Clin Orthop Relat Res. 2001;392:213\u201320.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"22_CR24","doi-asserted-by":"publisher","first-page":"339","DOI":"10.3109\/17453674.2011.574564","volume":"82","author":"S Ostermeier","year":"2011","unstructured":"Ostermeier S, Stukenborg-Colsman C. Quadriceps force after TKA with femoral single radius. Acta Orthop. 2011;82(3):339\u201343.","journal-title":"Acta Orthop"},{"issue":"3","key":"22_CR25","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s00167-013-2509-9","volume":"22","author":"R Mugnai","year":"2014","unstructured":"Mugnai R, Digennaro V, Ensini A, et al. Can TKA design affect the clinical outcome? Comparison between two guided-motion systems. Knee Surg Sports Traumatol Arthroscopy. 2014;22(3):581\u20139.","journal-title":"Knee Surg Sports Traumatol Arthroscopy."},{"issue":"5","key":"22_CR26","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1007\/s002640000167","volume":"24","author":"S Fuchs","year":"2000","unstructured":"Fuchs S, Tibesku CO, Floren M, et al. Interdependence of clinical and isokinetic results after bicondylar knee prostheses with special emphasis on quality of life results. Int Orthop. 2000;24(5):268\u201371.","journal-title":"Int Orthop"},{"key":"22_CR27","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1097\/00003086-199607000-00023","volume":"328","author":"CH Huang","year":"1996","unstructured":"Huang CH, Cheng CK, Lee YT, et al. Muscle strength after successful total knee replacement: a 6- to 13-year followup. Clin Orthop Relat Res. 1996;328:147\u201354.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"22_CR28","first-page":"38","volume":"71","author":"P Kannus","year":"1990","unstructured":"Kannus P, Jarvinen M. Knee flexor\/extensor strength ratio in follow-up of acute knee distortion injuries. Arch Phys Med Rehabil. 1990;71(1):38\u201341.","journal-title":"Arch Phys Med Rehabil"}],"container-title":["Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-020-0022-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s42836-020-0022-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-020-0022-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,8]],"date-time":"2021-02-08T05:50:16Z","timestamp":1612763416000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroplasty.biomedcentral.com\/articles\/10.1186\/s42836-020-0022-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,7]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["22"],"URL":"https:\/\/doi.org\/10.1186\/s42836-020-0022-4","relation":{},"ISSN":["2524-7948"],"issn-type":[{"value":"2524-7948","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,7]]},"assertion":[{"value":"14 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 February 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The present study was also approved by the institutional review board of Guangdong Provincial People\u2019s Hospital and signed informed consent for participation was obtained from all study patients.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Signed informed consent for publication was obtained from all study patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5"}}