{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:45:14Z","timestamp":1787021114328,"version":"build-2736575974"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,5,1]],"date-time":"2021-05-01T00:00:00Z","timestamp":1619827200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,5,1]],"date-time":"2021-05-01T00:00:00Z","timestamp":1619827200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Central Innovation Programme for SMEs","award":["944000\u2013033"],"award-info":[{"award-number":["944000\u2013033"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arthroplasty"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>All current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly influenced by the applied impulse and surrounding soft tissues. This leads to large differences in assembly forces between the surgeries. This study aimed to quantify the assembly forces of different surgeons under influence of surrounding soft tissue.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      First, a measuring system, consisting of a prosthesis and a hammer, was developed. Both components are equipped with a piezoelectric force sensor. Initially,\n                      <jats:italic>in situ<\/jats:italic>\n                      experiments on human cadavers were carried out using this system in order to determine the actual assembly forces and to characterize the influence of human soft tissues. Afterwards, an\n                      <jats:italic>in vitro<\/jats:italic>\n                      model in the form of an artificial femur (Sawbones Europe AB, Malmo, Sweden) with implanted measuring stem embedded in gelatine was developed. The gelatine mixture was chosen in such a way that assembly forces applied to the model corresponded to those\n                      <jats:italic>in situ<\/jats:italic>\n                      . A study involving 31 surgeons was carried out on the aforementioned\n                      <jats:italic>in vitro<\/jats:italic>\n                      model, in which the assembly forces were determined.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A model was developed, with the influence of human soft tissues being taken into account. The assembly forces measured on the\n                      <jats:italic>in vitro<\/jats:italic>\n                      model were, on average, 2037.2\u00a0N\u2009\u00b1\u2009724.9\u00a0N, ranging from 822.5\u00a0N to 3835.2\u00a0N. The comparison among the surgeons showed no significant differences in sex (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.09), work experience (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.71) and number of THAs performed per year (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.69).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      All measured assembly forces were below 4 kN, which is recommended in the literature. This could lead to increased corrosion following fretting in the head-neck interface. In addition, there was a very wide range of assembly forces among the surgeons, although other influencing factors such as different implant sizes or materials were not taken into account. To ensure optimal assembly force, the impaction should be standardized,\n                      <jats:italic>e.g<\/jats:italic>\n                      ., by using an appropriate surgical instrument.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s42836-021-00075-7","type":"journal-article","created":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T07:48:24Z","timestamp":1620028104000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Quantification of assembly forces during creation of head-neck taper junction considering soft tissue bearing: a biomechanical study"],"prefix":"10.1186","volume":"3","author":[{"given":"Toni","family":"Wendler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Torsten","family":"Prietzel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"M\u00f6bius","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Pierre","family":"Fischer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Roth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Zajonz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,5,1]]},"reference":[{"key":"75_CR1","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","volume":"370","author":"ID Learmonth","year":"2007","unstructured":"Learmonth ID, Young C, Rorabeck C. The operation of the century: Total hip replacement. The Lancet. 2007;370:1508\u201319. doi:https:\/\/doi.org\/10.1016\/S0140-6736(07)60457-7.","journal-title":"The Lancet"},{"key":"75_CR2","doi-asserted-by":"publisher","first-page":"e0167911","DOI":"10.1371\/journal.pone.0167911","volume":"11","author":"A Neuprez","year":"2016","unstructured":"Neuprez A, Delcour J-P, Fatemi F, Gillet P, Crielaard J-M, Bruy\u00e8re O, Reginster J-Y. Patients\u2019 Expectations Impact Their Satisfaction following Total Hip or Knee Arthroplasty. PLoS One. 2016;11:e0167911. doi:https:\/\/doi.org\/10.1371\/journal.pone.0167911.","journal-title":"PLoS One"},{"key":"75_CR3","unstructured":"Statistisches Bundesamt. Die 20 h\u00e4ufigsten Operationen insgesamt. 2018. ."},{"key":"75_CR4","unstructured":"Steiner C, Andrews R, Barrett M, Weiss AHCUP, Projections. Mobility\/Orthopedic Procedures 2003 to 2012. 2012. ."},{"key":"75_CR5","unstructured":"Australian Orthopaedic Association. Australian Orthopaedic Association National Joint Replacement Registry. Adelaide; 2012."},{"key":"75_CR6","doi-asserted-by":"publisher","first-page":"2088","DOI":"10.1016\/j.arth.2017.02.046","volume":"32","author":"CU Gwam","year":"2017","unstructured":"Gwam CU, Mistry JB, Mohamed NS, Thomas M, Bigart KC, Mont MA, Delanois RE. Current Epidemiology of Revision Total Hip Arthroplasty in the United States: National Inpatient Sample 2009 to 2013. J Arthroplasty. 2017;32:2088\u201392. doi:https:\/\/doi.org\/10.1016\/j.arth.2017.02.046.","journal-title":"J Arthroplasty"},{"key":"75_CR7","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.RVW.16.00002","author":"M Pollock","year":"2016","unstructured":"Pollock M, Somerville L, Firth A, Lanting B. Outpatient Total Hip Arthroplasty, Total Knee Arthroplasty, and Unicompartmental Knee Arthroplasty: A Systematic Review of the Literature. JBJS Rev. 2016. doi:https:\/\/doi.org\/10.2106\/JBJS.RVW.16.00002.","journal-title":"JBJS Rev"},{"key":"75_CR8","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1002\/jor.22326","volume":"31","author":"N Bishop","year":"2013","unstructured":"Bishop N, Witt F, Pourzal R, Fischer A, R\u00fctschi M, Michel M, Morlock M. Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings. J Orthop Res. 2013;31:1116\u201322. doi:https:\/\/doi.org\/10.1002\/jor.22326.","journal-title":"J Orthop Res"},{"key":"75_CR9","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1302\/2046-3758.14.2000047","volume":"1","author":"DJ Langton","year":"2012","unstructured":"Langton DJ, Sidaginamale R, Lord JK, Nargol AVF, Joyce TJ. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res. 2012;1:56\u201363. doi:https:\/\/doi.org\/10.1302\/2046-3758.14.2000047.","journal-title":"Bone Joint Res"},{"key":"75_CR10","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1007\/s11420-016-9526-4","volume":"13","author":"M Morlock","year":"2017","unstructured":"Morlock M, B\u00fcnte D, G\u00fchrs J, Bishop N. Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article. HSS J. 2017;13:42\u20139. doi:https:\/\/doi.org\/10.1007\/s11420-016-9526-4.","journal-title":"HSS J"},{"key":"75_CR11","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1302\/0301-620X.98B5.35592","volume":"98-B","author":"K Osman","year":"2016","unstructured":"Osman K, Panagiotidou AP, Khan M, Blunn G, Haddad FS. Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head-neck junctions. Bone Joint J. 2016;98-B:579\u201384. doi:https:\/\/doi.org\/10.1302\/0301-620X.98B5.35592.","journal-title":"Bone Joint J"},{"key":"75_CR12","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1053\/j.sart.2014.01.002","volume":"24","author":"SB Kocag\u00f6z","year":"2013","unstructured":"Kocag\u00f6z SB, Underwood RJ, Sivan S, Gilbert JL, Macdonald DW, Day JS, Kurtz SM. Does Taper Angle Clearance Influence Fretting and Corrosion Damage at the Head-Stem Interface? A Matched Cohort Retrieval Study. Semin Arthroplasty. 2013;24:246\u201354. doi:https:\/\/doi.org\/10.1053\/j.sart.2014.01.002.","journal-title":"Semin Arthroplasty"},{"key":"75_CR13","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1177\/112070001002000202","volume":"20","author":"D Lakstein","year":"2010","unstructured":"Lakstein D, Kosashvili Y, Backstein D, Safir O, Lee P, Gross AE. Revision total hip arthroplasty with a modular tapered stem. Hip Int. 2010;20:136\u201342.","journal-title":"Hip Int"},{"key":"75_CR14","doi-asserted-by":"publisher","first-page":"3101","DOI":"10.1007\/s11999-012-2502-5","volume":"470","author":"H Meyer","year":"2012","unstructured":"Meyer H, Mueller T, Goldau G, Chamaon K, Ruetschi M, Lohmann CH. Corrosion at the cone\/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties. Clin Orthop Relat Res. 2012;470:3101\u20138. doi:https:\/\/doi.org\/10.1007\/s11999-012-2502-5.","journal-title":"Clin Orthop Relat Res"},{"key":"75_CR15","first-page":"187","volume":"38","author":"CJ Lavernia","year":"2009","unstructured":"Lavernia CJ, Baerga L, Barrack RL, Tozakoglou E, Cook SD, Lata L, Rossi MD. The effects of blood and fat on Morse taper disassembly forces. Am J Orthop. 2009;38:187\u201390.","journal-title":"Am J Orthop"},{"key":"75_CR16","doi-asserted-by":"publisher","first-page":"3270","DOI":"10.1007\/s11999-013-3096-2","volume":"471","author":"SM Kurtz","year":"2013","unstructured":"Kurtz SM, Kocag\u00f6z SB, Hanzlik JA, Underwood RJ, Gilbert JL, Macdonald DW, et al. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Clin Orthop Relat Res. 2013;471:3270\u201382. doi:https:\/\/doi.org\/10.1007\/s11999-013-3096-2.","journal-title":"Clin Orthop Relat Res"},{"key":"75_CR17","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.clinbiomech.2011.08.002","volume":"27","author":"A Rehmer","year":"2012","unstructured":"Rehmer A, Bishop NE, Morlock MM. Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses. Clin Biomech (Bristol Avon). 2012;27:77\u201383. doi:https:\/\/doi.org\/10.1016\/j.clinbiomech.2011.08.002.","journal-title":"Clin Biomech (Bristol Avon)"},{"key":"75_CR18","doi-asserted-by":"publisher","first-page":"422","DOI":"10.3390\/met9040422","volume":"9","author":"K Fallahnezhad","year":"2019","unstructured":"Fallahnezhad K, Oskouei RH, Badnava H, Taylor M. The Influence of Assembly Force on the Material Loss at the Metallic Head-Neck Junction of Hip Implants Subjected to Cyclic Fretting Wear. Metals. 2019;9:422. doi:https:\/\/doi.org\/10.3390\/met9040422.","journal-title":"Metals"},{"key":"75_CR19","doi-asserted-by":"publisher","first-page":"1675","DOI":"10.1016\/j.arth.2016.11.054","volume":"32","author":"DN Ramoutar","year":"2017","unstructured":"Ramoutar DN, Crosnier EA, Shivji F, Miles AW, Gill HS. Assessment of Head Displacement and Disassembly Force With Increasing Assembly Load at the Head\/Trunnion Junction of a Total Hip Arthroplasty Prosthesis. J Arthroplasty. 2017;32:1675\u20138. doi:https:\/\/doi.org\/10.1016\/j.arth.2016.11.054.","journal-title":"J Arthroplasty"},{"key":"75_CR20","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1515\/BMT.2006.018","volume":"51","author":"R Nassutt","year":"2006","unstructured":"Nassutt R, Mollenhauer I, Klingbeil K, Henning O, Grundei H. Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head. Biomed Tech (Berl). 2006;51:103\u20139. doi:https:\/\/doi.org\/10.1515\/BMT.2006.018.","journal-title":"Biomed Tech (Berl)"},{"key":"75_CR21","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1002\/bjs.1800239213","volume":"23","author":"R Watson-Jones","year":"1936","unstructured":"Watson-Jones R. Fractures of the neck of the femur. Br J Surg. 1936;23:787\u2013808. doi:https:\/\/doi.org\/10.1002\/bjs.1800239213.","journal-title":"Br J Surg"},{"key":"75_CR22","doi-asserted-by":"publisher","first-page":"118","DOI":"10.2106\/00004623-199701000-00013","volume":"79","author":"IT Pulliam","year":"1997","unstructured":"Pulliam IT, Trousdale RT. Fracture of a ceramic femoral head after a revision operation. A case report. J Bone Joint Surg Am. 1997;79:118\u201321. doi:https:\/\/doi.org\/10.2106\/00004623-199701000-00013.","journal-title":"J Bone Joint Surg Am"},{"key":"75_CR23","doi-asserted-by":"publisher","first-page":"349","DOI":"10.5435\/JAAOS-D-15-00111","volume":"24","author":"JM Jennings","year":"2016","unstructured":"Jennings JM, Dennis DA, Yang CC. Corrosion of the Head-neck Junction After Total Hip Arthroplasty. J Am Acad Orthop Surg. 2016;24:349\u201356. doi:https:\/\/doi.org\/10.5435\/JAAOS-D-15-00111.","journal-title":"J Am Acad Orthop Surg"},{"key":"75_CR24","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1002\/jor.23601","volume":"36","author":"A Panagiotidou","year":"2018","unstructured":"Panagiotidou A, Cobb T, Meswania J, Skinner J, Hart A, Haddad F, Blunn G. Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: An in vitro study. J Orthop Res. 2018;36:405\u201316. doi:https:\/\/doi.org\/10.1002\/jor.23601.","journal-title":"J Orthop Res"},{"key":"75_CR25","doi-asserted-by":"publisher","first-page":"330","DOI":"10.5301\/HIP.2011.8408","volume":"21","author":"R Sakai","year":"2011","unstructured":"Sakai R, Takahashi A, Takahira N, Uchiyama K, Yamamoto T, Uchida K, et al. Hammering force during cementless total hip arthroplasty and risk of microfracture. Hip Int. 2011;21:330\u20135. doi:https:\/\/doi.org\/10.5301\/HIP.2011.8408.","journal-title":"Hip Int"},{"key":"75_CR26","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1177\/0954411916644477","volume":"230","author":"L Scholl","year":"2016","unstructured":"Scholl L, Schmidig G, Faizan A, TenHuisen K, Nevelos J. Evaluation of surgical impaction technique and how it affects locking strength of the head-stem taper junction. Proc Inst Mech Eng H. 2016;230:661\u20137. doi:https:\/\/doi.org\/10.1177\/0954411916644477.","journal-title":"Proc Inst Mech Eng H"},{"key":"75_CR27","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1302\/2046-3758.72.BJR-2017-0078.R2","volume":"7","author":"A Krull","year":"2018","unstructured":"Krull A, Morlock MM, Bishop NE. Maximizing the fixation strength of modular components by impaction without tissue damage. Bone Joint Res. 2018;7:196\u2013204. doi:https:\/\/doi.org\/10.1302\/2046-3758.72.BJR-2017-0078.R2.","journal-title":"Bone Joint Res"},{"key":"75_CR28","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1177\/0954411916648717","volume":"230","author":"H Haschke","year":"2016","unstructured":"Haschke H, Jauch-Matt SY, Sellenschloh K, Huber G, Morlock MM. Assembly force and taper angle difference influence the relative motion at the stem-neck interface of bi-modular hip prostheses. Proc Inst Mech Eng H. 2016;230:690\u20139. doi:https:\/\/doi.org\/10.1177\/0954411916648717.","journal-title":"Proc Inst Mech Eng H"},{"key":"75_CR29","doi-asserted-by":"publisher","DOI":"10.3390\/ma13081950","author":"CB Rieker","year":"2020","unstructured":"Rieker CB, Wahl P. What the Surgeon Can Do to Reduce the Risk of Trunnionosis in Hip Arthroplasty: Recommendations from the Literature. Materials (Basel). 2020. doi:https:\/\/doi.org\/10.3390\/ma13081950.","journal-title":"Materials (Basel)"}],"container-title":["Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-021-00075-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42836-021-00075-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-021-00075-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,20]],"date-time":"2021-07-20T21:10:14Z","timestamp":1626815414000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroplasty.biomedcentral.com\/articles\/10.1186\/s42836-021-00075-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["75"],"URL":"https:\/\/doi.org\/10.1186\/s42836-021-00075-7","relation":{},"ISSN":["2524-7948"],"issn-type":[{"value":"2524-7948","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,1]]},"assertion":[{"value":"19 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Institutional approval was granted for the use the post-mortem tissues in this study under the Saxonian Death and Funeral Act of 1994 (the third section, paragraph 18 item 8).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"20"}}