{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T03:54:30Z","timestamp":1773287670479,"version":"3.50.1"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,10,9]],"date-time":"2021-10-09T00:00:00Z","timestamp":1633737600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,10,9]],"date-time":"2021-10-09T00:00:00Z","timestamp":1633737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arthroplasty"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Introduction<\/jats:title>\n                <jats:p>The cementless acetabular implants are commonly used in primary and revision hip arthroplasty. Reconstruction of acetabulum in case of bone defects can be challenging. The aims of this single center study are to review the mid-term outcomes of porous tantalum cups (TM) and evaluate complications.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The midterm outcome of a trabecular metal tantalum modular uncemented cup was evaluated in 59 hips in 58 patients. In our group, we had 23 males and 35 females. The mean age was 70.11\u2009years (range, 30 to 87\u2009years). Four patients were lost to follow-up and 13 died during the period without having further surgeries attributed to the hip arthroplasty. The remaining 41 patients (42 revision hip arthroplasties) had complete data available.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean follow-up was 87\u2009months, ranging from 24\u2009to 144\u2009months. Standard pelvic anteroposterior (AP) radiographs were used to assess and preoperatively classify acetabular defects <jats:italic>as per<\/jats:italic> Paprosky classification. The serial radiographs showed excellent stability, bone opposition and graft incorporation. Four patients had further surgeries. Two of these were due to infection (one superficial and one deep infection). One of the patients had washout and then removal of metal work, the other patient only had a washout and symptoms settled. One patient had vascular compromise and went for surgery to stem the bleeding. One patient had re-revision due to stem loosening and hence required surgery but the revision cup remained stable. We noted a\u00a096% survival at an average of 7.2\u2009years follow-up.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The mid-term results with the trabecular metal cementless cup appeared to be promising in both primary and revision hip arthroplasty, even in the presence of considerable bone loss which requires bone grafting and augments.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>IV.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s42836-021-00099-z","type":"journal-article","created":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T18:07:47Z","timestamp":1633889267000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Mid-term outcomes of tantalum cup\u2013 a single centre study"],"prefix":"10.1186","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3127-0105","authenticated-orcid":false,"given":"Rajesh","family":"Bawale","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baseem","family":"Choudhry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Srinivasa","family":"Samsani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,10,9]]},"reference":[{"issue":"5","key":"99_CR1","doi-asserted-by":"publisher","first-page":"1612","DOI":"10.1016\/j.arth.2016.12.007","volume":"32","author":"AN Mahmoud","year":"2017","unstructured":"Mahmoud AN, Sundberg M, Flivik G. Comparable results with metal augments in combination with either cemented or Uncemented cups in revision hip Arthroplasty: an analysis of one hundred forty-seven revisions at a mean of five years. J Arthroplast. 2017;32(5):1612\u20137.","journal-title":"J Arthroplast"},{"issue":"4","key":"99_CR2","doi-asserted-by":"publisher","first-page":"780","DOI":"10.2106\/00004623-200704000-00012","volume":"89","author":"S Kurtz","year":"2007","unstructured":"Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780\u20135.","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"99_CR3","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/S0883-5403(03)00019-6","volume":"18","author":"TP Ng","year":"2003","unstructured":"Ng TP, Chiu KY. Acetabular revision without cement. J Arthroplast. 2003;18(4):435\u201341.","journal-title":"J Arthroplast"},{"issue":"11","key":"99_CR4","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.2106\/00004623-200111000-00014","volume":"83","author":"JE Templeton","year":"2001","unstructured":"Templeton JE, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83(11):1706\u201311.","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"99_CR5","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1016\/j.arth.2015.01.013","volume":"30","author":"J Wegrzyn","year":"2015","unstructured":"Wegrzyn J, Kaufman KR, Hanssen AD, Lewallen DG. Perfromance of porous tantalum vs. titanium cup in Total hip Arthroplasty: randomized trial with minimum 10-year follow-up. J Arthroplast. 2015;30(6):1008\u201313.","journal-title":"J Arthroplast"},{"issue":"9","key":"99_CR6","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.arth.2005.01.023","volume":"20","author":"AS Unger","year":"2005","unstructured":"Unger AS, Lewis RJ, Gruen T. Evaluation of a porous tantalum Uncemented Acetabular cup in revision Total hip Arthroplasty. J Arthroplasty. 2005;20(9):1002\u20139.","journal-title":"J Arthroplasty"},{"issue":"5","key":"99_CR7","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1302\/0301-620X.81B5.0810907","volume":"81","author":"JD Bobyn","year":"1999","unstructured":"Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new poous tantalum biomaterial. J Bone Joint Surg Br. 1999;81(5):907\u201314.","journal-title":"J Bone Joint Surg Br"},{"issue":"6","key":"99_CR8","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1016\/j.arth.2013.01.035","volume":"28","author":"JA Hanslik","year":"2013","unstructured":"Hanslik JA, Day JS, et al. Bone ingrowth in well-fixed retrieved porous tantalum implants. J Arthroplast. 2013;28(6):922\u20137.","journal-title":"J Arthroplast"},{"issue":"12","key":"99_CR9","doi-asserted-by":"publisher","first-page":"1397","DOI":"10.1016\/j.biomaterials.2004.05.036","volume":"26","author":"J Hong","year":"2005","unstructured":"Hong J, Azens A, Ekdahl KN, Granqvist CG, Nilsson B. Material-specific thrombin generation following contact between metal surfaces and whole blood. Biomaterials. 2005;26(12):1397\u2013403.","journal-title":"Biomaterials"},{"issue":"8","key":"99_CR10","doi-asserted-by":"publisher","first-page":"3349","DOI":"10.1016\/j.actbio.2010.01.046","volume":"6","author":"VK Balla","year":"2010","unstructured":"Balla VK, Bodhak S, Bose S, Bandyopadhyay A. Porous tantalum structures for bone implants: fabrication, mechanical and in vitro biological properties. Acta Biomater. 2010;6(8):3349\u201359.","journal-title":"Acta Biomater"},{"key":"99_CR11","doi-asserted-by":"crossref","unstructured":"Russell Levive B, Spoere S, Poggie RA, Della Valle CJ, Jacobs JJ. Experimental and clinical performance of porous tantalum in orthopaedic surgery. J Biomaterials. 2006;27(27):4671\u201381.","DOI":"10.1016\/j.biomaterials.2006.04.041"},{"issue":"1","key":"99_CR12","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1302\/0301-620X.97B1.34236","volume":"97","author":"AT Tokarski","year":"2015","unstructured":"Tokarski AT, Novack TA, Parvizi J. Is tantalum protective against infection in revision hip arthroplasty? Bone Joint J. 2015;97(1):45\u20139.","journal-title":"Bone Joint J"},{"issue":"2","key":"99_CR13","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1007\/s11999-009-1090-5","volume":"468","author":"SM Jafari","year":"2010","unstructured":"Jafari SM, Bender B, Coyle C, Parvizi J, Sharkey PF, Hozack WJ. Do tantalum and titanium cups show similar results in revision arthroplasty? Clin Orthop Related Research. 2010;468(2):459\u201362.","journal-title":"Clin Orthop Related Research"},{"issue":"5","key":"99_CR14","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1007\/s00264-007-0364-3","volume":"32","author":"SD Ulrich","year":"2008","unstructured":"Ulrich SD, Seyler TM, Bennett D, Delanois RE, Saleh KJ, Thongtrangan I, et al. Total hip arthroplasties: what are the reasons for revision? Int Orthop. 2008;32(5):597\u2013604.","journal-title":"Int Orthop"},{"key":"99_CR15","unstructured":"National Joint Registry 17th Annual Report, Sept 2020. United Kingdom."},{"issue":"2","key":"99_CR16","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1302\/0301-620X.95B2.30608","volume":"95-B","author":"M Abolghasemian","year":"2013","unstructured":"Abolghasemian M, Tangsataporn S, Sternheim A, Safir O, Gross AE. Combined trabecular metal shell and augment for acetabular revision with substantial bone loss: a mid-term review. Bone Joint J. 2013;95-B(2):166\u201372.","journal-title":"Bone Joint J"},{"issue":"8","key":"99_CR17","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1016\/j.arth.2011.02.022","volume":"26","author":"JH Davies","year":"2011","unstructured":"Davies JH, Laflamme GY, Delisle J, Fernandes J. Trabecular metal used for majo bone loss in acetabular hip revision. J Arthroplast. 2011;26(8):1245\u201350.","journal-title":"J Arthroplast"},{"issue":"2","key":"99_CR18","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1007\/s11999-009-1090-5","volume":"468","author":"SM Jafari","year":"2010","unstructured":"Jafari SM, Bender B, Coyle C, Parvizi J, Sharkey PF, Hozack WJ. Do tantalum and titanium show similar results in revision hip arthroplasty? Clin Orthop Relat Res. 2010;468(2):459\u201365.","journal-title":"Clin Orthop Relat Res"},{"issue":"9","key":"99_CR19","doi-asserted-by":"publisher","first-page":"2806","DOI":"10.1016\/j.arth.2017.03.065","volume":"32","author":"RE Delanois","year":"2017","unstructured":"Delanois RE, Gwam CU, Mohamed N, Khlopas A, Chughtai M, Malkani AL, et al. Midterm outocmes of revision Total hip Arthropalsty with the use of a multihole highlu porous titanium shell. J Arthroplast. 2017;32(9):2806\u20139.","journal-title":"J Arthroplast"},{"issue":"3","key":"99_CR20","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1007\/s00264-014-2509-5","volume":"39","author":"B Steno","year":"2015","unstructured":"Steno B, Kokavec M, Necas L. Acetabular revision arthroplasty using trabecular titanium implants. Int Orthop. 2015;39(3):389\u201395.","journal-title":"Int Orthop"},{"issue":"2","key":"99_CR21","doi-asserted-by":"publisher","first-page":"98","DOI":"10.5371\/hp.2016.28.2.98","volume":"28","author":"M Jeong","year":"2016","unstructured":"Jeong M, Kim H-J, Lim S-J, Moon Y-W, Park Y-S. Revision Total hip Arthroplasty using tantalum augment inpatients with Paprosky III or IV Acetabular bone defects: a minimum 2 \u2013 year follow up study. Hip Pelvis. 2016;28(2):98\u2013103.","journal-title":"Hip Pelvis"},{"key":"99_CR22","doi-asserted-by":"crossref","unstructured":"Mittien HJ, Mittien SS, Kettunen JS, Jalkanen J, Kroger H. Revision Hip Arthroplasty using a porous tantalum acetabular component. Hip Int.2020.","DOI":"10.1177\/1120700020913294"},{"issue":"3","key":"99_CR23","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.aott.2019.03.007","volume":"53","author":"MD Paolis","year":"2019","unstructured":"Paolis MD, Zucchini R, Romagnoli C, Romantini M, Mariotti F, Federica M, et al. Middle term results of tantalum acetabular cups in total hip arthroplasty following pelvic irradiation. Acta Orthop Traumatol Turc. 2019;53(3):165\u20139.","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"2","key":"99_CR24","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1007\/s11999.0000000000000005","volume":"476","author":"PF Lachiewiecz","year":"2018","unstructured":"Lachiewiecz PF, O\u2019dell J. Tantalum Componenets in difficult Acetabular revisions have good survival at 5 to 10 years: longer term follow up pf a previous report. Clin Orthop Realt Res. 2018;476(2):336\u201342.","journal-title":"Clin Orthop Realt Res"},{"key":"99_CR25","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1097\/01.blo.0000150133.88271.80","volume":"429","author":"A Nehme","year":"2004","unstructured":"Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;429:201\u20138.","journal-title":"Clin Orthop Relat Res"},{"key":"99_CR26","doi-asserted-by":"crossref","unstructured":"Lochel J, Janz V, Hipfl C, Perka C, Wassilew G.I. Reconstruction of acetabular defects with porous tantalum shells and augments in revision total hip arthroplasty at ten years follow up. Bone Joint J, 2019;101-B (3):311\u2013316.","DOI":"10.1302\/0301-620X.101B3.BJJ-2018-0959.R1"},{"issue":"5","key":"99_CR27","first-page":"623","volume":"75","author":"J Jean-Pierre Simon","year":"2009","unstructured":"Jean-Pierre Simon J. Bellemans. Clincal and radiological evaluation of modular trabecular metal acetabular cups. Short-term results in 64 hips. Act Orthop Belgica. Oct 2009;75(5):623\u201330.","journal-title":"Act Orthop Belgica"},{"issue":"7","key":"99_CR28","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1302\/0301-620X.88B7.17150","volume":"88","author":"JE Phillips","year":"2006","unstructured":"Phillips JE, Crane TP, Not M. The incidence of deep prosthetic infection in a specialist orthopaedic hospital: a 15-year prospective survey. J Bone Joint Surg Br. 2006;88(7):943\u20138.","journal-title":"J Bone Joint Surg Br"},{"key":"99_CR29","doi-asserted-by":"crossref","unstructured":"Toakrski AT, Novack TA, Parvizi J. Is tantalum protective against infection in revision total hip arthroplasty? Bone Joint J 2015;97- B (1):45\u20139.","DOI":"10.1302\/0301-620X.97B1.34236"},{"issue":"12","key":"99_CR30","doi-asserted-by":"publisher","first-page":"3015","DOI":"10.1007\/s11999-017-5417-3","volume":"475","author":"I Laaksonen","year":"2017","unstructured":"Laaksonen I, Lorimer M, Gromoy K, Rolfson O, Makela K, Graves S, et al. Does the risk of revision vary between porous tantalum cups and other Cementless designs after revision hip Arthroplasty? Clin Orthop Relat Res. 2017;475(12):3015\u201322.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"99_CR31","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1080\/17453674.2018.1463007","volume":"89","author":"N Hailer","year":"2018","unstructured":"Hailer N. 20 years of porous tantalum in primary and revision hip arthroplasty-time for a critical appraisal. Acta Orthop. 2018;89(3):254\u20135.","journal-title":"Acta Orthop"}],"container-title":["Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-021-00099-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42836-021-00099-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-021-00099-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T20:45:44Z","timestamp":1633898744000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroplasty.biomedcentral.com\/articles\/10.1186\/s42836-021-00099-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,9]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["99"],"URL":"https:\/\/doi.org\/10.1186\/s42836-021-00099-z","relation":{},"ISSN":["2524-7948"],"issn-type":[{"value":"2524-7948","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,9]]},"assertion":[{"value":"6 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"42"}}