{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T13:28:28Z","timestamp":1780320508590,"version":"3.54.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,3]],"date-time":"2024-12-03T00:00:00Z","timestamp":1733184000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,3]],"date-time":"2024-12-03T00:00:00Z","timestamp":1733184000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012664","name":"International Joint Laboratory for MicroNano Manufacturing and Measurement Technologies","doi-asserted-by":"publisher","award":["21KK0281"],"award-info":[{"award-number":["21KK0281"]}],"id":[{"id":"10.13039\/501100012664","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["2023-RP03"],"award-info":[{"award-number":["2023-RP03"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arthroplasty"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Despite recent developments in THA, a more objective method is needed to assist orthopedic surgeons in identifying the insertion endpoint of the broaching procedure. Therefore, this systematic review evaluated the in-vivo efficacy of various acoustic and vibration analyses in detecting proper implant seating, identifying intraoperative complications, and quantifying the accuracy of predictive modeling using acoustics.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Four electronic databases were searched on July 23rd, 2023, to retrieve articles evaluating the use of acoustic analysis during THA. The search identified 835 unique articles, which were subsequently screened by two independent reviewers as per our inclusion and exclusion criteria. In total, 12 studies evaluating 580 THAs were found to satisfy our criteria and were included in this review.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Methodologically, analyses have suggested stopping broaching when consecutive blows emit similar acoustic profiles (maximum peak frequency\u00a0\u00b1\u00a00.5 kHz), which indicates proper implant seating in terms of stability and mitigates subsidence. Also, abrupt large deviations from the typical progression of acoustic signals while broaching are indicative of an intraoperative fracture. Since height, weight, femoral morphological parameters, and implant type have been shown to alter acoustic emissions while hammering, incorporating these factors into models to predict subsidence or intraoperative fracture yielded virtually 100% accuracy in identifying these adverse events.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>These findings support that acoustic analyses during THA show promise as an accurate, objective, and non-invasive method to predict and detect proper implant fixation as well as to identify intraoperative fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Trial registration<\/jats:title>\n                <jats:p>PROSPERO registration of the study protocol: CRD42023447889, 23 July 2023.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s42836-024-00280-0","type":"journal-article","created":{"date-parts":[[2024,12,3]],"date-time":"2024-12-03T00:01:40Z","timestamp":1733184100000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["What is the clinical utility of acoustic and vibrational analyses in uncemented total hip arthroplasty?"],"prefix":"10.1186","volume":"6","author":[{"given":"Shlok","family":"Patel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"II","given":"Christian J.","family":"Hecht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuhiro","family":"Homma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9214-2756","authenticated-orcid":false,"given":"Atul F.","family":"Kamath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,3]]},"reference":[{"key":"280_CR1","doi-asserted-by":"publisher","first-page":"229","DOI":"10.4236\/jbise.2022.159021","volume":"15","author":"X Zhuang","year":"2022","unstructured":"Zhuang X, Homma Y, Sato T, et al. Factors influence on the broaching hammering sound during cementless total hip arthroplasty. J Biomed Sci Eng. 2022;15:229\u201340.","journal-title":"J Biomed Sci Eng"},{"key":"280_CR2","doi-asserted-by":"publisher","unstructured":"Homma Y, Zhuang X, Yanagisawa N, et al. Patients with shorter stature exhibit minimal hammering sound changes during cementless stem insertion in total hip arthroplasty. Arthroplast Today 21. https:\/\/doi.org\/10.1016\/j.artd.2023.101136. Epub ahead of print 1 June 2023.","DOI":"10.1016\/j.artd.2023.101136"},{"key":"280_CR3","doi-asserted-by":"publisher","unstructured":"Morohashi I, Iwase H, Kanda A, et al. Acoustic pattern evaluation during cementless hip arthroplasty surgery may be a new method for predicting complications. SICOT J 3. https:\/\/doi.org\/10.1051\/sicotj\/2016049. Epub ahead of print 2017","DOI":"10.1051\/sicotj\/2016049"},{"key":"280_CR4","first-page":"576","volume":"10","author":"M Mulier","year":"2008","unstructured":"Mulier M, Pastrav C, Van der Perre G. Per-operative vibration analysis: a valuable tool for defining correct stem insertion: preliminary report. Ortop Traumatol Rehabil. 2008;10:576\u201382.","journal-title":"Ortop Traumatol Rehabil"},{"key":"280_CR5","doi-asserted-by":"publisher","unstructured":"Wei JCJ, Crezee WHA, Jongeneel H, et al. Using acoustic vibrations as a method for implant insertion assessment in total hip arthroplasty. Sensors 22. https:\/\/doi.org\/10.3390\/s22041609. Epub ahead of print 1 February 2022","DOI":"10.3390\/s22041609"},{"key":"280_CR6","doi-asserted-by":"crossref","unstructured":"Berend KR, Lombardi AV. Intraoperative Femur Fracture is Associated with Stem and Instrument Design in Primary Total Hip Arthroplasty. Clin Orthop Relat Res. 2010;468:2377\u201381.","DOI":"10.1007\/s11999-010-1314-8"},{"key":"280_CR7","doi-asserted-by":"publisher","unstructured":"Homma Y, Ito S, Zhuang X, et al. Artificial intelligence for distinguishment of hammering sound in total hip arthroplasty. Sci Rep 12. https:\/\/doi.org\/10.1038\/s41598-022-14006-2. Epub ahead of print 1 December 2022.","DOI":"10.1038\/s41598-022-14006-2"},{"key":"280_CR8","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1080\/03091902.2017.1411986","volume":"42","author":"PHM Pechon","year":"2018","unstructured":"Pechon PHM, Pullin R, Eaton MJ, et al. Acoustic emission technology can warn of impending iatrogenic femur fracture during femoral canal preparation for uncemented hip replacement. A cadaveric animal bone study. J Med Eng Technol. 2018;42:72\u201387.","journal-title":"J Med Eng Technol"},{"key":"280_CR9","doi-asserted-by":"publisher","unstructured":"Leuridan S, Goossens Q, Pastrav LC, et al. Development of an instrument to assess the stability of cementless femoral implants using vibration analysis during total hip arthroplasty. IEEE J Transl Eng Health Med 9. https:\/\/doi.org\/10.1109\/JTEHM.2021.3128276. Epub ahead of print 2021.","DOI":"10.1109\/JTEHM.2021.3128276"},{"key":"280_CR10","first-page":"334","volume":"20","author":"RM Meneghini","year":"2010","unstructured":"Meneghini RM, Guthrie M, Moore HD, et al. A novel method for prevention of intraoperative fracture in cementless hip arthroplasty: vibration analysis during femoral component insertion. Surg Technol Int. 2010;20:334\u20139.","journal-title":"Surg Technol Int"},{"key":"280_CR11","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1080\/10255842.2011.650635","volume":"16","author":"MA P\u00e9rez","year":"2013","unstructured":"P\u00e9rez MA, Seral-Garc\u00eda B. A finite element analysis of the vibration behaviour of a cementless hip system. Comput Methods Biomech Biomed Engin. 2013;16:1022\u201331.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"280_CR12","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1177\/0954411912462813","volume":"227","author":"G Whitwell","year":"2013","unstructured":"Whitwell G, Brockett CL, Young S, et al. Spectral analysis of the sound produced during femoral broaching and implant insertion in uncemented total hip arthroplasty. Proc Inst Mech Eng H. 2013;227:175\u201380.","journal-title":"Proc Inst Mech Eng H"},{"key":"280_CR13","doi-asserted-by":"publisher","unstructured":"Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. The BMJ 339. https:\/\/doi.org\/10.1136\/BMJ.B2700. Epub ahead of print 2009.","DOI":"10.1136\/BMJ.B2700"},{"key":"280_CR14","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1002\/jor.24837","volume":"39","author":"Q Goossens","year":"2021","unstructured":"Goossens Q, Pastrav L, Roosen J, et al. Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study. J Orthop Res. 2021;39:1164\u201373.","journal-title":"J Orthop Res"},{"key":"280_CR15","doi-asserted-by":"publisher","unstructured":"Sakai R. \u2018Development of total hip arthroplasty support system for predicting intraoperative fractures by the frequency of hammering sound\u2019. Biomed J Sci Tech Res 44. https:\/\/doi.org\/10.26717\/bjstr.2022.44.007081. Epub ahead of print 20 June 2022.","DOI":"10.26717\/bjstr.2022.44.007081"},{"key":"280_CR16","doi-asserted-by":"publisher","first-page":"14","DOI":"10.4236\/jbise.2021.141003","volume":"14","author":"R Sakai","year":"2021","unstructured":"Sakai R, Uchiyama K, Fukushima K, et al. Hammering sound frequency analysis to fix an acetabular cup during total hip arthroplasty: clinical trials and biomechanical studies. J Biomed Sci Eng. 2021;14:14\u201320.","journal-title":"J Biomed Sci Eng"},{"key":"280_CR17","doi-asserted-by":"publisher","first-page":"1559","DOI":"10.1302\/0301-620X.100B12.BJJ-2018-0368.R2","volume":"100-B","author":"JS McConnell","year":"2018","unstructured":"McConnell JS, Saunders PRJ, Young SK. The clinical relevance of sound changes produced during cementless hip arthroplasty. Bone Joint J. 2018;100-B:1559\u201364.","journal-title":"Bone Joint J"},{"key":"280_CR18","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1007\/s00264-021-05278-w","volume":"46","author":"X Zhuang","year":"2022","unstructured":"Zhuang X, Homma Y, Ishii S, et al. Acoustic characteristics of broaching procedure for post-operative stem subsidence in cementless total hip arthroplasty. Int Orthop. 2022;46:741\u20138.","journal-title":"Int Orthop"},{"key":"280_CR19","doi-asserted-by":"publisher","unstructured":"Pastrav LC, Jaecques SV, Jonkers I, et al. In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses. J Orthop Surg Res 4. https:\/\/doi.org\/10.1186\/1749-799X-4-10. Epub ahead of print 2009.","DOI":"10.1186\/1749-799X-4-10"},{"key":"280_CR20","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s00264-022-05641-5","volume":"47","author":"Y Homma","year":"2023","unstructured":"Homma Y, Zhuang X, Ohtsu H, et al. Highly accurate acoustical prediction using support vector machine algorithm for post-operative subsidence after cementless total hip arthroplasty. Int Orthop. 2023;47:187\u201392.","journal-title":"Int Orthop"},{"key":"280_CR21","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1046\/j.1445-2197.2003.02748.x","volume":"73","author":"K Slim","year":"2003","unstructured":"Slim K, Nini E, Forestier D, et al. Methodological index for non-randomized studies (MINORS): development and validation of a new instrument. ANZ J Surg. 2003;73:712\u20136.","journal-title":"ANZ J Surg"},{"key":"280_CR22","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1007\/s00264-018-4020-x","volume":"43","author":"C Ries","year":"2019","unstructured":"Ries C, Boese CK, Dietrich F, et al. Femoral stem subsidence in cementless total hip arthroplasty: a retrospective single-centre study. Int Orthop. 2019;43:307\u201314.","journal-title":"Int Orthop"},{"key":"280_CR23","first-page":"7080","volume":"14","author":"X Feng","year":"2022","unstructured":"Feng X, Gu J, Zhou Y. Primary total hip arthroplasty failure: aseptic loosening remains the most common cause of revision. Am J Transl Res. 2022;14:7080\u20139.","journal-title":"Am J Transl Res"},{"key":"280_CR24","doi-asserted-by":"publisher","first-page":"1835","DOI":"10.1007\/s00068-020-01549-0","volume":"48","author":"JKM Fakler","year":"2022","unstructured":"Fakler JKM, Brand A, Lycke C, et al. Risk factors for intraoperative greater trochanteric fractures in hemiarthroplasty for intracapsular femoral neck fractures. Eur J Trauma Emerg Surg. 2022;48:1835\u201340.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"280_CR25","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1111\/os.13646","volume":"15","author":"Y Liu","year":"2023","unstructured":"Liu Y, Li C, Cao Z, et al. Undetected intraoperative periprosthetic femoral fractures in patients undergoing primary total hip arthroplasty: a retrospective case series and literature review. Orthop Surg. 2023;15:758\u201365.","journal-title":"Orthop Surg"},{"key":"280_CR26","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1007\/s12570-012-0120-z","volume":"4","author":"F Marqu\u00e9s Lopez","year":"2013","unstructured":"Marqu\u00e9s Lopez F, Mu\u00f1oz Vives JM. Intraoperative periprosthetic hip fractures. Eur Orthop Traumatol. 2013;4:89\u201392.","journal-title":"Eur Orthop Traumatol"},{"key":"280_CR27","first-page":"1952","volume":"88","author":"GJ Haidukewych","year":"2006","unstructured":"Haidukewych GJ. Intraoperative fractures of the acetabulum during primary total hip arthroplasty. J Bone Joint Surg (American). 2006;88:1952.","journal-title":"J Bone Joint Surg (American)"},{"key":"280_CR28","unstructured":"Masonis J, Thompson C, Odum S. Safe and accurate: learning the direct anterior total hip arthroplasty. Orthopedics. 2008;31(12 Suppl 2)."},{"key":"280_CR29","doi-asserted-by":"publisher","first-page":"2013","DOI":"10.1016\/j.arth.2016.02.045","volume":"31","author":"JM Hartford","year":"2016","unstructured":"Hartford JM, Knowles SB. Risk factors for perioperative femoral fractures: cementless femoral implants and the direct anterior approach using a fracture table. J Arthroplasty. 2016;31:2013\u20138.","journal-title":"J Arthroplasty"},{"key":"280_CR30","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1016\/j.arth.2005.09.014","volume":"21","author":"I Asayama","year":"2006","unstructured":"Asayama I, Kinsey TL, Mahoney OM. Two-year experience using a limited-incision direct lateral approach in total hip arthroplasty. J Arthroplasty. 2006;21:1083\u201391.","journal-title":"J Arthroplasty"},{"key":"280_CR31","doi-asserted-by":"publisher","unstructured":"Siddiqi A, Springer BD, Chen AF, et al. Diagnosis and management of intraoperative fractures in primary total hip arthroplasty. J Am Acad Orthop Surg. https:\/\/doi.org\/10.5435\/JAAOS-D-20-00818. Epub ahead of print 20 January 2021.","DOI":"10.5435\/JAAOS-D-20-00818"},{"key":"280_CR32","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1007\/s11517-020-02202-z","volume":"58","author":"AR Remya","year":"2020","unstructured":"Remya AR, Vishwash B, Lee C, et al. Hip implant performance prediction by acoustic emission techniques: a review. Med Biol Eng Comput. 2020;58:1637\u201350.","journal-title":"Med Biol Eng Comput"},{"key":"280_CR33","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1136\/postgradmedj-2017-135352","volume":"94","author":"X Chen","year":"2018","unstructured":"Chen X, Xiong J, Wang P, et al. Robotic-assisted compared with conventional total hip arthroplasty: systematic review and meta-analysis. Postgrad Med J. 2018;94:335\u201341.","journal-title":"Postgrad Med J"},{"key":"280_CR34","doi-asserted-by":"publisher","unstructured":"Emara AK, Samuel LT, Acu\u00f1a AJ, et al. Robotic-arm assisted versus manual total hip arthroplasty: systematic review and meta-analysis of radiographic accuracy. Int J Med Robot Comp Assisted Surg 17. https:\/\/doi.org\/10.1002\/rcs.2332. Epub ahead of print 1 December 2021.","DOI":"10.1002\/rcs.2332"},{"key":"280_CR35","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s11701-021-01315-3","volume":"16","author":"AF Kamath","year":"2022","unstructured":"Kamath AF, Durbhakula SM, Pickering T, et al. Improved accuracy and fewer outliers with a novel CT-free robotic THA system in matched-pair analysis with manual THA. J Robot Surg. 2022;16:905\u201313.","journal-title":"J Robot Surg"}],"container-title":["Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-024-00280-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42836-024-00280-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42836-024-00280-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,3]],"date-time":"2024-12-03T01:03:27Z","timestamp":1733187807000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroplasty.biomedcentral.com\/articles\/10.1186\/s42836-024-00280-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,3]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["280"],"URL":"https:\/\/doi.org\/10.1186\/s42836-024-00280-0","relation":{},"ISSN":["2524-7948"],"issn-type":[{"value":"2524-7948","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,3]]},"assertion":[{"value":"14 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All data included in this study were publicly available and did not include protected health information. Therefore, this study was considered exempt from ethical review board approval.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"A.F.K. reports the following disclosures: paid presenter or speaker (Zimmer Biomet), paid consultant (Zimmer Biomet, BodyCad, Ortho Development, United Ortho), stock or stock options (Zimmer Biomet, Johnson & Johnson, and Procter & Gamble), IP royalties (Innomed), and board or committee member (AAOS, AAHKS, and Anterior Hip Foundation). Y.H. reports the following disclosures: paid presenter or speaker (Zimmer Biomet Japan, B. Braun Aesculap, Smith and Nephew), paid consultant (Zimmer Biomet Japan, Kyocera, and Teijin Nakashima Medical). S.P. and C.J.H. have nothing to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"59"}}