{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T01:54:04Z","timestamp":1787968444526,"version":"build-2784847793"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Knee Surg &amp; Relat Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Repair of a meniscal tear is indicated in certain conditions. Despite extensive research on the biomechanics of various repair methods, there has been minimal investigation of whether the suture material influences the meniscal-suture construct. The purpose of this study was to compare the biomechanical properties of nine different suture materials under cyclic and load-to-failure conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Ninety porcine menisci were randomly allocated to simple suture placement using either Ultrabraid\u00ae, Ultratape\u00ae, Magnum Wire\u00ae, TigerWire\u00ae, TigerTape\u00ae, LabralTape\u00ae, Orthocord\u00ae, 0 FiberWire\u00ae, or 2-0 FiberWire\u00ae. Each suture-meniscus specimen underwent cyclic loading followed by load-to-failure testing. Elongation, maximum load to failure, stiffness, and mode of failure were recorded and compared between each suture type using non-parametric testing. Mean\u2009\u00b1\u2009standard deviation was reported and the statistical significance was\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Elongation during cyclic loading was lowest with 2-0 FiberWire (0.95\u2009\u00b1\u20090.17\u2009mm); this value was statistically significantly different than the results for all other sutures except 0 FiberWire\u00ae (1.09\u2009\u00b1\u20090.17\u2009mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.79), TigerWire\u00ae (1.09\u2009\u00b1\u20090.29\u2009mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.85), TigerTape\u00ae (1.39\u2009\u00b1\u20090.29\u2009mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.08), and LabralTape\u00ae (1.20\u2009\u00b1\u20090.33\u2009mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.41). The highest elongation was seen with Ultrabraid\u00ae (1.91\u2009\u00b1\u20090.34\u2009mm); this value was statistically significantly greater than the results for all other suture materials except Orthocord\u00ae (1.59\u2009mm\u2009\u00b1\u20090.31\u2009mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.46) and Magnum Wire\u00ae (1.43\u2009\u00b1\u20090.25\u2009mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.14). Load to failure was highest for TigerTape\u00ae (287.43\u2009\u00b1\u200941.15\u2009N), and this result was statistically significantly different than the results for all other sutures except LabralTape\u00ae (271.34\u2009\u00b1\u200948.48\u2009N,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.99) and TigerWire\u00ae (251.03\u2009\u00b1\u200925.8\u2009N,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.51). Stiffness was highest for LabralTape\u00ae (195.77\u2009\u00b1\u200949.06\u2009N\/mm), and this result was statistically significantly different than the results for all other sutures except TigerWire\u00ae (186.49\u2009\u00b1\u200919.83\u2009N\/mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.45) and TigerTape\u00ae (173.35\u2009\u00b1\u200915.60\u2009N\/mm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.19). The majority of sutures failed by pullout (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200946, 51%) or tearing (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200940, 45%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Suture design and material affect the biomechanical behavior of porcine meniscal-suture specimens. LabralTape\u00ae, TigerWire\u00ae, and TigerTape\u00ae demonstrated better overall combinations of low elongation, high maximum load to failure, and high stiffness.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s43019-020-00053-4","type":"journal-article","created":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T07:03:52Z","timestamp":1598598232000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["The influence of suture materials on the biomechanical behavior of suture-meniscal specimens: a comparative study in a porcine model"],"prefix":"10.1186","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8934-6053","authenticated-orcid":false,"given":"John Reza","family":"Matthews","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiefei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiwei","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melissa A.","family":"Kluczynski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leslie J.","family":"Bisson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,8,28]]},"reference":[{"issue":"5","key":"53_CR1","doi-asserted-by":"publisher","first-page":"435","DOI":"10.3109\/17453679008993557","volume":"61","author":"A Hede","year":"1990","unstructured":"Hede A, Jensen DB, Blyme P, Sonne-Holm S (1990) Epidemiology of meniscal lesions in the knee. 1,215 open operations in Copenhagen 1982-84. Acta Orthop Scand 61(5):435\u2013437","journal-title":"Acta Orthop Scand"},{"key":"53_CR2","doi-asserted-by":"publisher","first-page":"2098","DOI":"10.1007\/s00167-011-1794-4","volume":"20","author":"SH Choi","year":"2012","unstructured":"Choi SH, Bae S, Ji SK, Chang MJ (2012) The MRI findings of meniscal root tear of the medial meniscus: emphasis on coronal, sagittal and axial images. Knee Surg Sports Traumatol Arthrosc 20:2098\u20132103","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"53_CR3","doi-asserted-by":"publisher","first-page":"1326","DOI":"10.1016\/j.arthro.2010.01.032","volume":"26","author":"SB Han","year":"2010","unstructured":"Han SB, Shetty GM, Lee DH, Chae DJ, Seo SS, Wang KH et al (2010) Unfavorable results of partial meniscectomy for complete posterior medial meniscus root tear with early osteoarthritis: a 5- to 8-year follow-up study. Arthroscopy 26:1326\u20131332","journal-title":"Arthroscopy"},{"key":"53_CR4","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1302\/0301-620X.91B2.21097","volume":"91","author":"DD Robertson","year":"2009","unstructured":"Robertson DD, Armfield DR, Towers JD, Irrgang JJ, Maloney WJ, Harner CD (2009) Meniscal root injury and spontaneous osteonecrosis of the knee: an observation. J Bone Joint Surg (Br) 91:190\u2013195","journal-title":"J Bone Joint Surg (Br)"},{"key":"53_CR5","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1016\/j.arthro.2012.11.016","volume":"29","author":"JH Sung","year":"2013","unstructured":"Sung JH, Ha JK, Lee DW, Seo WY, Kim JG (2013) Meniscal extrusion and spontaneous osteonecrosis with root tear of medial meniscus: comparison with horizontal tear. Arthroscopy 29:726\u2013732","journal-title":"Arthroscopy"},{"key":"53_CR6","doi-asserted-by":"publisher","first-page":"1922","DOI":"10.2106\/JBJS.G.00748","volume":"90","author":"R Allaire","year":"2008","unstructured":"Allaire R, Muriuki M, Gilbertson L, Harner CD (2008) Biomechanical consequences of a tear of the posterior root of the medial meniscus. Similar to total meniscectomy. J Bone Joint Surg Am 90:1922\u20131931","journal-title":"J Bone Joint Surg Am"},{"key":"53_CR7","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1007\/s00402-013-1716-7","volume":"133","author":"P Forkel","year":"2013","unstructured":"Forkel P, Herbort M, Schulze M, Rosenbaum D, Kirstein L, Raschke M et al (2013) Biomechanical consequences of a posterior root tear of the lateral meniscus: stabilizing effect of the meniscofemoral ligament. Arch Orthop Trauma Surg 133:621\u2013626","journal-title":"Arch Orthop Trauma Surg"},{"key":"53_CR8","doi-asserted-by":"publisher","first-page":"2121","DOI":"10.1007\/s00167-012-2182-4","volume":"21","author":"JG Kim","year":"2013","unstructured":"Kim JG, Lee YS, Bae TS, Ha JK, Lee DH, Kim YJ et al (2013) Tibiofemoral contact mechanics following posterior root of medial meniscus tear, repair, meniscectomy, and allograft transplantation. Knee Surg Sports Traumatol Arthrosc 21:2121\u20132125","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"53_CR9","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1177\/0363546508323254","volume":"37","author":"JM Marzo","year":"2009","unstructured":"Marzo JM, Gurske-DePerio J (2009) Effects of medial meniscus posterior horn avulsion and repair on tibiofemoral contact area and peak contact pressure with clinical implications. Am J Sports Med 37:124\u2013129","journal-title":"Am J Sports Med"},{"key":"53_CR10","doi-asserted-by":"publisher","first-page":"2604","DOI":"10.1177\/0363546512458574","volume":"40","author":"CK Schillhammer","year":"2012","unstructured":"Schillhammer CK, Werner FW, Scuderi MG, Cannizzaro JP (2012) Repair of lateral meniscus posterior horn detachment lesions: a biomechanical evaluation. Am J Sports Med 40:2604\u20132609","journal-title":"Am J Sports Med"},{"key":"53_CR11","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s00402-008-0639-1","volume":"129","author":"JH Ahn","year":"2009","unstructured":"Ahn JH, Wang JH, Lim HC, Bae JH, Park JS, Yoo JC et al (2009) Double transosseous pull out suture technique for transection of posterior horn of medial meniscus. Arch Orthop Trauma Surg 129:387\u2013392","journal-title":"Arch Orthop Trauma Surg"},{"key":"53_CR12","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1007\/s00167-007-0310-3","volume":"15","author":"JH Ahn","year":"2007","unstructured":"Ahn JH, Wang JH, Yoo JC, Noh HK, Park JH (2007) A pull out suture for transection of the posterior horn of the medial meniscus: using a posterior trans-septal portal. Knee Surg Sports Traumatol Arthrosc 15:1510\u20131513","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"53_CR13","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s00402-011-1429-8","volume":"132","author":"P Forkel","year":"2012","unstructured":"Forkel P, Petersen W (2012) Posterior root tear fixation of the lateral meniscus combined with arthroscopic ACL double-bundle reconstruction: technical note of a transosseous fixation using the tibial PL tunnel. Arch Orthop Trauma Surg 132:387\u2013391","journal-title":"Arch Orthop Trauma Surg"},{"issue":"Suppl 2","key":"53_CR14","doi-asserted-by":"publisher","first-page":"257","DOI":"10.2106\/JBJS.I.00500","volume":"91","author":"CD Harner","year":"2009","unstructured":"Harner CD, Mauro CS, Lesniak BP, Romanowski JR (2009) Biomechanical consequences of a tear of the posterior root of the medial meniscus. Surgical technique. J Bone Joint Surg Am 91(Suppl 2):257\u2013270","journal-title":"J Bone Joint Surg Am"},{"key":"53_CR15","doi-asserted-by":"publisher","first-page":"1138","DOI":"10.1177\/0363546511435622","volume":"40","author":"HK Moon","year":"2012","unstructured":"Moon HK, Koh YG, Kim YC, Park YS, Jo SB, Kwon SK (2012) Prognostic factors of arthroscopic pull-out repair for a posterior root tear of the medial meniscus. Am J Sports Med 40:1138\u20131143","journal-title":"Am J Sports Med"},{"key":"53_CR16","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1007\/s00167-013-2656-z","volume":"23","author":"MJ Feucht","year":"2015","unstructured":"Feucht MJ, Grande E, Brunhuber J, Rosenstiel N, Burgkart R, Imhoff AB et al (2015) Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears. Knee Surg Sports Traumatol Arthrosc 23:132\u2013139","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"53_CR17","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1007\/s00167-012-2131-2","volume":"21","author":"YM Kim","year":"2013","unstructured":"Kim YM, Joo YB (2013) Pullout failure strength of the posterior horn of the medial meniscus with root ligament tear. Knee Surg Sports Traumatol Arthrosc 21:1546\u20131552","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"53_CR18","doi-asserted-by":"publisher","first-page":"2141","DOI":"10.1177\/0363546511413250","volume":"39","author":"S Kopf","year":"2011","unstructured":"Kopf S, Colvin AC, Muriuki M, Zhang X, Harner CD (2011) Meniscal root suturing techniques: implications for root fixation. Am J Sports Med 39:2141\u20132146","journal-title":"Am J Sports Med"},{"key":"53_CR19","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/s00402-012-1625-1","volume":"133","author":"SB Rosslenbroich","year":"2013","unstructured":"Rosslenbroich SB, Borgmann J, Herbort M, Raschke MJ, Petersen W, Zantop T (2013) Root tear of the meniscus: biomechanical evaluation of an arthroscopic refixation technique. Arch Orthop Trauma Surg 133:111\u2013115","journal-title":"Arch Orthop Trauma Surg"},{"key":"53_CR20","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1016\/j.arthro.2010.04.075","volume":"26","author":"LJ Bisson","year":"2010","unstructured":"Bisson LJ, Manohar LM (2010) A biomechanical comparison of the pullout strength of No. 2 FiberWire suture and 2-mm FiberWire tape in bovine rotator cuff tendons. Arthroscopy 26:1463\u20131468","journal-title":"Arthroscopy"},{"key":"53_CR21","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1177\/0363546508314793","volume":"36","author":"LJ Bisson","year":"2008","unstructured":"Bisson LJ, Manohar LM, Wilkins RD, Gurske-Deperio J, Ehrensberger MT (2008) Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff. Am J Sports Med 36:907\u2013912","journal-title":"Am J Sports Med"},{"key":"53_CR22","doi-asserted-by":"publisher","first-page":"2281","DOI":"10.1177\/0363546510382847","volume":"38","author":"M Herbort","year":"2010","unstructured":"Herbort M, Siam S, Lenschow S, Petersen W, Zantop T (2010) Strategies for repair of radial tears close to the meniscal rim\u2014biomechanical analysis with a cyclic loading protocol. Am J Sports Med 38:2281\u20132287","journal-title":"Am J Sports Med"},{"key":"53_CR23","first-page":"663","volume":"46","author":"P Jaspers","year":"1980","unstructured":"Jaspers P, de Lange A, Huiskes R, van Rens TJ (1980) The mechanical function of the meniscus, experiments on cadaveric pig knee-joints. Acta Orthop Belg 46:663\u2013668","journal-title":"Acta Orthop Belg"},{"key":"53_CR24","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.1016\/j.arthro.2012.06.015","volume":"28","author":"YH Lee","year":"2012","unstructured":"Lee YH, Nyland J, Burden R, Caborn DN (2012) Cyclic test comparison of all-inside device and inside-out sutures for radial meniscus lesion repair: an in vitro porcine model study. Arthroscopy 28:1873\u20131881","journal-title":"Arthroscopy"},{"key":"53_CR25","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1016\/S0749-8063(97)90008-6","volume":"13","author":"WR Post","year":"1997","unstructured":"Post WR, Akers SR, Kish V (1997) Load to failure of common meniscal repair techniques: effects of suture technique and suture material. Arthroscopy 13:731\u2013736","journal-title":"Arthroscopy"},{"key":"53_CR26","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1177\/0363546505285583","volume":"34","author":"T Zantop","year":"2006","unstructured":"Zantop T, Temmig K, Weimann A, Eggers AK, Raschke MJ, Petersen W (2006) Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios: biomechanical evaluation using a cyclic loading protocol. Am J Sports Med 34:799\u2013805","journal-title":"Am J Sports Med"},{"key":"53_CR27","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1177\/0363546503260749","volume":"32","author":"T Zantop","year":"2004","unstructured":"Zantop T, Eggers AK, Weimann A, Hassenpflug J, Petersen W (2004) Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors: biomechanical evaluation of new meniscus refixation systems. Am J Sports Med 32:863\u2013869","journal-title":"Am J Sports Med"},{"key":"53_CR28","doi-asserted-by":"publisher","first-page":"934","DOI":"10.1016\/j.arthro.2005.05.022","volume":"21","author":"T Zantop","year":"2005","unstructured":"Zantop T, Ruemmler M, Welbers B, Langer M, Weimann A, Petersen W (2005) Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts. Arthroscopy 21:934\u2013941","journal-title":"Arthroscopy"},{"key":"53_CR29","first-page":"403","volume":"88","author":"CB Ma","year":"2006","unstructured":"Ma CB, Comerford L, Wilson J, Puttlitz CM (2006) Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation. J Bone Joint Surg Am 88:403\u2013410","journal-title":"J Bone Joint Surg Am"},{"key":"53_CR30","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.2106\/00004623-200406000-00013","volume":"86-A","author":"CB Ma","year":"2004","unstructured":"Ma CB, MacGillivray JD, Clabeaux J, Lee S, Otis JC (2004) Biomechanical evaluation of arthroscopic rotator cuff stitches. J Bone Joint Surg Am 86-A:1211\u20131216","journal-title":"J Bone Joint Surg Am"},{"key":"53_CR31","volume-title":"Stringtheory: an examination of the properties of \u201chigh strength\u201d suture materials","author":"A Jhamb","year":"2007","unstructured":"Jhamb A, Goldberg J, Harper W, Butler A, Smitham PJ, Walsh WR (2007) Stringtheory: an examination of the properties of \u201chigh strength\u201d suture materials. University of New South Wales, Prince of Wales Hospital, Sydney"},{"key":"53_CR32","unstructured":"DePuy Synthes Mitek Sports Medicine. Orthocord\u2122 Product Information. 2015. http:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/INT%20Mobile\/Synthes%20International\/Product%20Support%20Material\/legacy_DePuy_Mitek_PDFs\/DSEM-MTK-0414-0064_LR.pdf."},{"key":"53_CR33","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1016\/j.arthro.2009.08.013","volume":"26","author":"C St\u00e4rke","year":"2010","unstructured":"St\u00e4rke C, Kopf S, Gr\u00f6bel KH, Becker R (2010) The effect of a nonanatomic repair of the meniscal horn attachment on meniscal tension: a biomechanical study. Arthroscopy 26:358\u2013365","journal-title":"Arthroscopy"},{"key":"53_CR34","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1007\/s00256-004-0761-2","volume":"33","author":"DB Lerer","year":"2004","unstructured":"Lerer DB, Umans HR, Hu MX, Jones MH (2004) The role of meniscal root pathology and radial meniscal tear in medial meniscal extrusion. Skelet Radiol 33:569\u2013574","journal-title":"Skelet Radiol"},{"key":"53_CR35","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.1002\/jor.20949","volume":"27","author":"C St\u00e4rke","year":"2009","unstructured":"St\u00e4rke C, Kopf S, Gr\u00f6bel KH, Becker R (2009) Tensile forces at the porcine anterior meniscal horn attachment. J Orthop Res 27:1619\u20131624","journal-title":"J Orthop Res"},{"key":"53_CR36","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/S0749-8063(00)90037-9","volume":"16","author":"SS Burkhart","year":"2000","unstructured":"Burkhart SS, Wirth MA, Simonich M, Salem D, Lanctot D, Athanasiou K (2000) Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure must the knot be? Arthroscopy 16:202\u2013207","journal-title":"Arthroscopy"},{"key":"53_CR37","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/S0749-8063(98)70110-0","volume":"14","author":"SS Burkhart","year":"1998","unstructured":"Burkhart SS, Wirth MA, Simonick M, Salem D, Lanctot D, Athanasiou K (1998) Loop security as a determinant of tissue fixation security. Arthroscopy 14:773\u2013776","journal-title":"Arthroscopy"},{"key":"53_CR38","doi-asserted-by":"publisher","first-page":"1146","DOI":"10.1016\/j.arthro.2006.06.013","volume":"22","author":"DM W\u00fcst","year":"2006","unstructured":"W\u00fcst DM, Meyer DC, Favre P, Gerber C (2006) Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures. Arthroscopy 22:1146\u20131153","journal-title":"Arthroscopy"},{"key":"53_CR39","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1177\/0363546513479775","volume":"41","author":"YH Lee","year":"2013","unstructured":"Lee YH, Nyland J, Burden R, Caborn DN (2013) Repair of peripheral vertical meniscus lesions in porcine menisci: in vitro biomechanical testing of 3 different meniscus repair devices. Am J Sports Med 41:1074\u20131081","journal-title":"Am J Sports Med"},{"key":"53_CR40","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s001670100247","volume":"10","author":"M A\u015f\u00edk","year":"2002","unstructured":"A\u015f\u00edk M, Sener N (2002) Failure strength of repair devices versus meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 10:25\u201329","journal-title":"Knee Surg Sports Traumatol Arthrosc"}],"container-title":["Knee Surgery &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s43019-020-00053-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s43019-020-00053-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s43019-020-00053-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,27]],"date-time":"2021-08-27T19:14:20Z","timestamp":1630091660000},"score":1,"resource":{"primary":{"URL":"https:\/\/kneesurgrelatres.biomedcentral.com\/articles\/10.1186\/s43019-020-00053-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,28]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["53"],"URL":"https:\/\/doi.org\/10.1186\/s43019-020-00053-4","relation":{},"ISSN":["2234-2451"],"issn-type":[{"value":"2234-2451","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,28]]},"assertion":[{"value":"3 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"42"}}