{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T23:48:24Z","timestamp":1740181704477,"version":"3.37.3"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,7]],"date-time":"2020-09-07T00:00:00Z","timestamp":1599436800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,7]],"date-time":"2020-09-07T00:00:00Z","timestamp":1599436800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Egypt Heart J"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>The most common post-surgical complication of tetralogy of Fallot (TOF) is pulmonary regurgitation (PR) which can lead to right ventricle (RV) dysfunction\/failure. Cardiac magnetic resonance (CMR) is the imaging modality of choice to follow-up a repaired TOF. However, the conventional two-dimensional phase-contrast (2D-PC) flow usually underestimates PR as well as the pulmonary peak systolic velocity (PSV). Recently, four-dimensional (4D) CMR flow is introduced for more accurate quantitative flow assessment. This work aimed to compare between 4D-CMR and 2D-PC flow across the main (MPA), right (RPA), and left (LPA) pulmonary arteries (PAs) in surgically corrected TOF patients.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>This study was conducted on 20 repaired TOF patients (range 3\u20139 years, 50% males). All patients had CMR exam on 1.5T scanner. 4D-CMR and 2D-PC flows were obtained at the proximal segments of the MPA, RPA, and LPA. The stroke volume index (SVI), regurgitation fraction (RF), and PSV measured by 4D-CMR were compared to 2D-PC flow. The SVI across the PAs was nearly similar between both methods (<jats:italic>P<\/jats:italic> = 0.179 for MPA, 0.218 for RPA, and 0.091 for LPA). However, the RF was significantly higher by 4D-CMR in comparison to 2D-PC flow (<jats:italic>P<\/jats:italic> = 0.027 for MPA, 0.039 for RPA, and 0.046 for LPA). The PSV as well was significantly higher by 4D-CMR flow (<jats:italic>P<\/jats:italic> = 0.003 for MPA, &lt; 0.001 for RPA, and 0.002 for LPA). The Bland-Altman plots showed a good agreement between 4D-CMR and 2D-PC flow for the SVI, RF, and PSV across the pulmonary arteries.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>A good agreement existed between the two studied methods regarding pulmonary flow measurements. Because of its major advantage of performing a comprehensive flow assessment in a shorter time, 4D-CMR flow plays an important role in the assessment of patients with complex CHD especially in the pediatric group.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s43044-020-00092-y","type":"journal-article","created":{"date-parts":[[2020,9,7]],"date-time":"2020-09-07T12:02:41Z","timestamp":1599480161000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Assessment of flow pattern of right ventricle outflow and pulmonary arteries in surgically corrected tetralogy of Fallot patients by four-dimensional cardiac magnetic resonance flow"],"prefix":"10.1186","volume":"72","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2801-4901","authenticated-orcid":false,"given":"Mahmoud","family":"Shaaban","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mai","family":"Salama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayman","family":"Alsaied","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raghda","family":"Elsheikh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magdy","family":"Elmasry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,9,7]]},"reference":[{"issue":"9699","key":"92_CR1","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1016\/S0140-6736(09)60657-7","volume":"374","author":"C Apitz","year":"2009","unstructured":"Apitz C, Webb GD, Redington AN (2009) Tetralogy of fallot. Lancet. 374(9699):1462\u20131471","journal-title":"Lancet."},{"issue":"1","key":"92_CR2","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/S0003-4975(10)64489-X","volume":"41","author":"CW Lillehei","year":"1986","unstructured":"Lillehei CW, Varco RL, Cohen M, Warden HE, Patton C, Moller JH (1986) The first open-heart repairs of ventricular septal defect, atrioventricular communis, and tetralogy of Fallot using extracorporeal circulation by cross-circulation: a 30-year follow-up. Ann Thorac Surg 41(1):4\u201321","journal-title":"Ann Thorac Surg"},{"issue":"12","key":"92_CR3","doi-asserted-by":"publisher","first-page":"1663","DOI":"10.1136\/hrt.2008.147249","volume":"94","author":"KV Huehnergarth","year":"2008","unstructured":"Huehnergarth KV, Gurvitz M, Stout KK, Otto CM (2008) Repaired tetralogy of Fallot in the adult: monitoring and management. Heart. 94(12):1663\u20131669","journal-title":"Heart."},{"issue":"11","key":"92_CR4","doi-asserted-by":"publisher","first-page":"2044","DOI":"10.1016\/S0735-1097(02)02566-4","volume":"40","author":"PA Davlouros","year":"2002","unstructured":"Davlouros PA, Kilner PJ, Hornung TS, Li W, Francis JM, Moon JCC et al (2002) Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction. J Am Coll Cardiol 40(11):2044\u20132052","journal-title":"J Am Coll Cardiol"},{"issue":"7","key":"92_CR5","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1093\/eurheartj\/ehp586","volume":"31","author":"PJ Kilner","year":"2010","unstructured":"Kilner PJ, Geva T, Kaemmerer H, Trindade PT, Schwitter J, Webb GD (2010) Recommendations for cardiovascular magnetic resonance in adults with congenital heart disease from the respective working groups of the European Society of Cardiology. Eur Heart J 31(7):794\u2013805. Available from:. https:\/\/doi.org\/10.1093\/eurheartj\/ehp586","journal-title":"Eur Heart J"},{"issue":"1","key":"92_CR6","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1148\/rg.261055064","volume":"26","author":"KI Norton","year":"2006","unstructured":"Norton KI, Tong C, Glass RBJ, Nielsen JC (2006) Cardiac MR imaging assessment following tetralogy of Fallot repair 1. Radiographics. 26(1):197\u2013211","journal-title":"Radiographics."},{"issue":"4","key":"92_CR7","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1002\/jmri.20871","volume":"25","author":"M Markl","year":"2007","unstructured":"Markl M, Harloff A, Bley TA, Zaitsev M, Jung B, Weigang E et al (2007) Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging 25(4):824\u2013831","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"92_CR8","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1148\/radiol.12120778","volume":"267","author":"P B\u00e4chler","year":"2013","unstructured":"B\u00e4chler P, Valverde I, Pinochet N, Nordmeyer S, Kuehne T, Crelier G et al (2013) Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging. Radiology. 267(1):67\u201375","journal-title":"Radiology."},{"issue":"1","key":"92_CR9","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1007\/s00330-013-2998-4","volume":"24","author":"J Geiger","year":"2014","unstructured":"Geiger J, Hirtler D, B\u00fcrk J, Stiller B, Arnold R, Jung B et al (2014) Postoperative pulmonary and aortic 3D haemodynamics in patients after repair of transposition of the great arteries. Eur Radiol 24(1):200\u2013208","journal-title":"Eur Radiol"},{"issue":"8","key":"92_CR10","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1007\/s00247-013-2641-1","volume":"43","author":"D Hirtler","year":"2013","unstructured":"Hirtler D, Geiger J, Jung B, Markl M, Arnold R (2013) 4-D MRI flow analysis in the course of interrupted aortic arch reveals complex morphology and quantifies amount of collateral blood flow. Pediatr Radiol 43(8):1037\u20131040","journal-title":"Pediatr Radiol"},{"key":"92_CR11","unstructured":"Mu\u00f1oz DR, Markl M, JLM M, Barker A, Fern\u00e1ndez-Golf\u00edn C, Lancellotti P et al (2013) Intracardiac flow visualization: current status and future directions. Eur Heart J Cardiovasc Imaging jet086"},{"key":"92_CR12","doi-asserted-by":"crossref","unstructured":"Jacobs KG, Chan FP, Cheng JY, Vasanawala SS, Maskatia SA (2020) 4D flow vs. 2D cardiac MRI for the evaluation of pulmonary regurgitation and ventricular volume in repaired tetralogy of Fallot: a retrospective case control study. Int J Card Imaging:1\u201313","DOI":"10.1007\/s10554-019-01751-1"},{"issue":"10","key":"92_CR13","doi-asserted-by":"publisher","first-page":"1849","DOI":"10.1016\/j.ejrad.2016.07.018","volume":"85","author":"RG Chelu","year":"2016","unstructured":"Chelu RG, Wanambiro KW, Hsiao A, Swart LE, Voogd T, van den Hoven AT et al (2016) Cloud-processed 4D CMR flow imaging for pulmonary flow quantification. Eur J Radiol 85(10):1849\u20131856","journal-title":"Eur J Radiol"},{"issue":"3","key":"92_CR14","first-page":"285","volume":"10","author":"M-A Isorni","year":"2018","unstructured":"Isorni M-A, Tortigue M, Ben Moussa N, Hasco\u00ebt S, Monnot S (2018) 4D Flow CMR analysis in repaired Tetralogy of Fallot: Where we are and where we are going. Arch Cardiovasc Dis Suppl 10(3):285 Available from: http:\/\/www.sciencedirect.com\/science\/article\/pii\/S1878648018302192","journal-title":"Arch Cardiovasc Dis Suppl"},{"issue":"1","key":"92_CR15","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1002\/jmri.23793","volume":"37","author":"S Nordmeyer","year":"2013","unstructured":"Nordmeyer S, Riesenkampff E, Messroghli D, Kropf S, Nordmeyer J, Berger F et al (2013) Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow. J Magn Reson Imaging 37(1):208\u2013216","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"92_CR16","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1007\/s00247-014-3246-z","volume":"45","author":"M Gabbour","year":"2015","unstructured":"Gabbour M, Schnell S, Jarvis K, Robinson JD, Markl M, Rigsby CK (2015) 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography. Pediatr Radiol 45(6):804\u2013813. Available from. https:\/\/doi.org\/10.1007\/s00247-014-3246-z","journal-title":"Pediatr Radiol"}],"container-title":["The Egyptian Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s43044-020-00092-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s43044-020-00092-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s43044-020-00092-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T23:16:46Z","timestamp":1630970206000},"score":1,"resource":{"primary":{"URL":"https:\/\/tehj.springeropen.com\/articles\/10.1186\/s43044-020-00092-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,7]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["92"],"URL":"https:\/\/doi.org\/10.1186\/s43044-020-00092-y","relation":{},"ISSN":["2090-911X"],"issn-type":[{"type":"electronic","value":"2090-911X"}],"subject":[],"published":{"date-parts":[[2020,9,7]]},"assertion":[{"value":"20 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"An informed written consent was taken from each participant\u2019s father or mother. This study was approved by Research Ethics Committee, Quality Assurance Unit, Faculty of Medicine, Tanta University, with the following approval code: 31542\/05\/17.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"57"}}