{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T21:02:25Z","timestamp":1762981345632,"version":"3.37.3"},"reference-count":6,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,5,4]],"date-time":"2022-05-04T00:00:00Z","timestamp":1651622400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,4]],"date-time":"2022-05-04T00:00:00Z","timestamp":1651622400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Egypt Heart J"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Structural valve failure in the form of leaflet fracture and embolization is an uncommon complication. Severe valve regurgitation with pulmonary oedema in a patient with a history of a prosthetic cardiac valve requires urgent diagnosis. An echocardiogram is essential in identifying the cause of valve failure.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>We report a case of a 21-year-old male patient who presented with acute pulmonary oedema due to fracture and embolization of a leaflet of an On-X mitral valve four years post-implant. He underwent an emergency redo mitral valve replacement with a good outcome.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Structural valve failure with leaflet fracture and embolization is an extremely rare complication and may be fatal. Good clinical acumen is required for prompt diagnosis in any patient who presents with a circulatory collapse in the presence of a history of previous cardiac surgery. Once the diagnosis is made, the patient should undergo emergency redo valve replacement surgery.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s43044-022-00270-0","type":"journal-article","created":{"date-parts":[[2022,5,4]],"date-time":"2022-05-04T10:04:21Z","timestamp":1651658661000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["On-X mitral valve leaflet embolization presenting as acute pulmonary oedema"],"prefix":"10.1186","volume":"74","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2618-3100","authenticated-orcid":false,"given":"Lindiwe","family":"Sidali","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nandipha","family":"Ndibi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manogran","family":"Moopanar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajhmun","family":"Madansein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,5,4]]},"reference":[{"issue":"18","key":"270_CR1","doi-asserted-by":"publisher","first-page":"2303","DOI":"10.1161\/01.CIR.0000070590.42796.F0","volume":"107","author":"T Bottio","year":"2003","unstructured":"Bottio T, Casarotto D, Thiene G, Caprili L, Angelini A, Gerosa G (2003) Leaflet escape in a new bileaflet mechanical valve: TRI technologies. Circulation 107(18):2303\u20132306","journal-title":"Circulation"},{"issue":"3","key":"270_CR2","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1111\/jocs.13975","volume":"34","author":"GG van Steenbergen","year":"2019","unstructured":"van Steenbergen GG, Tsang QH, van der Heide SM, Verkroost MW, Li WW, Morshuis WJ (2019) Spontaneous leaflet fracture resulting in embolization from mechanical valve prostheses. J Card Surg 34(3):124\u2013130","journal-title":"J Card Surg"},{"key":"270_CR3","doi-asserted-by":"publisher","first-page":"e199","DOI":"10.1016\/j.athoracsur.2020.01.023","volume":"110","author":"N G\u00f6bel","year":"2020","unstructured":"G\u00f6bel N, Tanriverdi S, Nagib R, Franke UF (2020) Cardiogenic shock due to leaflet migration of On-X\u00ae aortic mechanical prosthesis. Ann Thorac Surg 110:e199\u2013e200","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"270_CR4","doi-asserted-by":"publisher","first-page":"e307","DOI":"10.1016\/j.athoracsur.2019.03.064","volume":"108","author":"CA Rivera","year":"2019","unstructured":"Rivera CA, Rodr\u00edguez FJL, Garc\u00eda MEA, Abascal RAA, Varela AMB, Tatis MML et al (2019) Survival after mitral valve replacement for leaflet escape in a contemporary on-X mechanical valve. Ann Thorac Surg 108(5):e307\u2013e309","journal-title":"Ann Thorac Surg"},{"issue":"1","key":"270_CR5","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.euje.2005.12.007","volume":"8","author":"TF Cianciulli","year":"2007","unstructured":"Cianciulli TF, Lax JA, Saccheri MC, Redruello HJ, Belforte SM, Picone VP et al (2007) Acute mitral valve dysfunction due to leaflet escape in a Tri-technologies bileaflet mechanical valve. Eur J Echocardiogr 8(1):63\u201366","journal-title":"Eur J Echocardiogr"},{"key":"270_CR6","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1093\/ejcts\/ezy122","volume":"15","author":"S Kageyama","year":"2018","unstructured":"Kageyama S, Yoshioka D, Kawasumi R, Ohashi T (2018) Sudden haemodynamic collapse caused by leaflet escape of the contemporary On-X mechanical valve. Eur J Cardio-Thorac Surg 15:608","journal-title":"Eur J Cardio-Thorac Surg"}],"container-title":["The Egyptian Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s43044-022-00270-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s43044-022-00270-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s43044-022-00270-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,4]],"date-time":"2022-05-04T10:05:42Z","timestamp":1651658742000},"score":1,"resource":{"primary":{"URL":"https:\/\/tehj.springeropen.com\/articles\/10.1186\/s43044-022-00270-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,4]]},"references-count":6,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["270"],"URL":"https:\/\/doi.org\/10.1186\/s43044-022-00270-0","relation":{},"ISSN":["2090-911X"],"issn-type":[{"type":"electronic","value":"2090-911X"}],"subject":[],"published":{"date-parts":[[2022,5,4]]},"assertion":[{"value":"16 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written consent for participation was obtained from patient available which should be requested.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written consent for publication was obtained from patient available which should be requested.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they all have no competing interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"36"}}