{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T10:30:57Z","timestamp":1788172257156,"version":"build-2803163510"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T00:00:00Z","timestamp":1750032000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T00:00:00Z","timestamp":1750032000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Echo Res Pract"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>The number of patients referred for and requiring a transthoracic echocardiogram (TTE) has increased over the years resulting in more cardiac sonographers reporting work related musculoskeletal pain. We sought to determine if a scanning protocol that replaced conventional workflows with advanced technologies such as multiplane imaging, artificial intelligence (AI) and automation could be used to optimise conventional workflows and potentially reduce ergonomic risk for cardiac sonographers. The aim was to assess whether this alternate protocol could reduce active scanning time as well as interaction with the ultrasound machine compared to a standard echocardiogram without a reduction in image quality and interpretability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method and results<\/jats:title>\n            <jats:p>Volunteer participants were recruited for a study that comprised of two TTE\u2019s with separate protocols. Both were clinically complete, but Protocol A combined automation, AI assisted acquisition and measurement, simultaneous and multiplane imaging whilst Protocol B reflected a standard scanning protocol without these additional technologies. Keystrokes were significantly reduced with the advanced protocol as compared to the typical protocol (230.9\u2009\u00b1\u200924.2 vs. 502.8\u2009\u00b1\u200956.2; difference 271.9\u2009\u00b1\u200961.3, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Furthermore, there was a reduction in scan time with protocol A compared to protocol B the standard TTE protocol (13.4\u2009\u00b1\u20092.3\u00a0min vs. 18.0\u2009\u00b1\u20092.6\u00a0min; difference 4.6\u2009\u00b1\u20092.9\u00a0min, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) as well as a decrease of approximately 27% in the time the sonographers were required to reach beyond a neutral position on the ultrasound console.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>A TTE protocol that embraces modern technologies such as AI, automation, and multiplane imaging shows potential for a reduction in ultrasound keystrokes and scan time without a reduction in quality and interpretability. This may aid a reduction in ergonomic workload as compared to a standard TTE.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s44156-025-00077-0","type":"journal-article","created":{"date-parts":[[2025,6,15]],"date-time":"2025-06-15T23:02:02Z","timestamp":1750028522000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Can automation and artificial intelligence reduce echocardiography scan time and ultrasound system interaction?"],"prefix":"10.1186","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-1757-4796","authenticated-orcid":false,"given":"Kylie J.","family":"Hollitt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven","family":"Milanese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Majo","family":"Joseph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rebecca","family":"Perry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,16]]},"reference":[{"issue":"10","key":"77_CR1","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1016\/j.echo.2022.06.011","volume":"35","author":"MP Henry","year":"2022","unstructured":"Henry MP, Cotella JI, Slivnick JA, Yamat M, Hipke K, Johnson R, et al. Three-dimensional echocardiographic deconstruction: feasibility of clinical evaluation from two-dimensional views derived from a three-dimensional data set. J Am Soc Echocardiogr. 2022;35(10):1009\u201317..e2.","journal-title":"J Am Soc Echocardiogr"},{"key":"77_CR2","doi-asserted-by":"publisher","unstructured":"Sehly A, Jaltotage B, He A, Maiorana A, Ihdayhid AR, Rajwani A, et al. Artificial intelligence in echocardiography: the time is now. RCM. 2022;23(8). https:\/\/doi.org\/10.31083\/j.rcm2308256.","DOI":"10.31083\/j.rcm2308256"},{"issue":"6","key":"77_CR3","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1016\/j.jcmg.2018.11.038","volume":"12","author":"MT Nolan","year":"2019","unstructured":"Nolan MT, Thavendiranathan P. Automated quantification in echocardiography. JACC: Cardiovasc Imaging. 2019;12(6):1073\u201392. https:\/\/doi.org\/10.1016\/j.jcmg.2018.11.038.","journal-title":"JACC: Cardiovasc Imaging"},{"issue":"1","key":"77_CR4","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1002\/sono.12093","volume":"4","author":"OJ Pallotta","year":"2017","unstructured":"Pallotta OJ, Roberts A. Musculoskeletal pain and injury in sonographers, causes and solutions. Sonography. 2017;4(1):5\u201312. https:\/\/doi.org\/10.1002\/sono.12093.","journal-title":"Sonography"},{"issue":"4","key":"77_CR5","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1177\/1742271X15593575","volume":"23","author":"G Harrison","year":"2015","unstructured":"Harrison G, Harris A. Work-related musculoskeletal disorders in ultrasound: can you reduce risk? Ultrasound. 2015;23(4):224\u201330. https:\/\/doi.org\/10.1177\/1742271X15593575.","journal-title":"Ultrasound"},{"issue":"4","key":"77_CR6","doi-asserted-by":"publisher","first-page":"263","DOI":"10.14797\/mdcj-16-4-263","volume":"16","author":"K Seetharam","year":"2020","unstructured":"Seetharam K, Min JK. Artificial intelligence and machine learning in cardiovascular imaging. Methodist Debakey Cardiovasc J. 2020;16(4):263. https:\/\/doi.org\/10.14797\/mdcj-16-4-263.","journal-title":"Methodist Debakey Cardiovasc J"},{"issue":"2","key":"77_CR7","doi-asserted-by":"publisher","first-page":"50","DOI":"10.3390\/jimaging90200508","volume":"9","author":"T Barry","year":"2023","unstructured":"Barry T, Farina JM, Chao C-J, Ayoub C, Jeong J, Patel BN, et al. The role of artificial intelligence in echocardiography. J Imaging. 2023;9(2):50. https:\/\/doi.org\/10.3390\/jimaging90200508.","journal-title":"J Imaging"},{"key":"77_CR8","unstructured":"Du Bois D, Du Bois EF. A formula to estimate the approximate surface area if height and weight be known. 1916. Nutrition. 1989 Sep-Oct;5(5):303\u2013\u200911; discussion 312-3. PMID: 2520314."},{"issue":"1","key":"77_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.echo.2018.06.004","volume":"32","author":"C Mitchell","year":"2019","unstructured":"Mitchell C, Rahko PS, Blauwet LA, Canaday B, Finstuen JA, Foster MC, et al. Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults: recommendations from the American society of echocardiography. J Am Soc Echocardiogr. 2019;32(1):1\u201364. https:\/\/doi.org\/10.1016\/j.echo.2018.06.004.","journal-title":"J Am Soc Echocardiogr"},{"issue":"4","key":"77_CR10","doi-asserted-by":"publisher","first-page":"792","DOI":"10.2214\/AJR.15.15030","volume":"206","author":"R Sanyal","year":"2016","unstructured":"Sanyal R, Kraft B, Alexander LF, Ismail A, Lockhart ME, Robbin ML. Scanner-based protocol-driven ultrasound: an effective method to improve efficiency in an ultrasound department. Am J Roentgenol. 2016;206(4):792\u20136.","journal-title":"Am J Roentgenol"},{"key":"77_CR11","unstructured":"McLeod K, Sprem J. GE Healthcare The role of artificial intelligence in streamlining echocardiography quantification. Available from: whitepaper_the-role-of-artificial-intelligence__jb20789xx.pdf"},{"key":"77_CR12","volume-title":"The sensible taskmaster. Rev. And enlarged","author":"GC Heyde","year":"1978","unstructured":"Heyde GC. The sensible taskmaster. Rev. And enlarged. 2nd ed. ed. Sydney: Heyde Dynamics; 1978.","edition":"2"},{"issue":"3","key":"77_CR13","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.3233\/WOR-220211","volume":"76","author":"S Harmse","year":"2023","unstructured":"Harmse S, Buys TL, Claassen N. Assessing work speed using MODAPTS: A tool for occupational therapists. Work. 2023;76(3):1167\u201376. https:\/\/doi.org\/10.3233\/WOR-220211.","journal-title":"Work"},{"issue":"8","key":"77_CR14","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.7863\/ultra.32.8.1363","volume":"32","author":"JP Baker","year":"2013","unstructured":"Baker JP, Coffin CT. The importance of an ergonomic workstation to practicing sonographers. J Ultrasound Med. 2013;32(8):1363\u201375. https:\/\/doi.org\/10.7863\/ultra.32.8.1363.","journal-title":"J Ultrasound Med"},{"issue":"5","key":"77_CR15","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1177\/8756479317726767","volume":"33","author":"S Murphey","year":"2017","unstructured":"Murphey S. Work related musculoskeletal disorders in sonography. J Diagn Med Sonography. 2017;33(5):354\u201369. https:\/\/doi.org\/10.1177\/8756479317726767.","journal-title":"J Diagn Med Sonography"},{"issue":"3","key":"77_CR16","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1016\/j.shaw.2017.08.007","volume":"9","author":"JG Simonsen","year":"2018","unstructured":"Simonsen JG, Dahlqvist C, Enquist H, Nordander C, Axmon A, Arvidsson I. Assessments of physical workload in sonography tasks using inclinometry, goniometry, and electromyography. Saf Health Work. 2018;9(3):326\u201333. https:\/\/doi.org\/10.1016\/j.shaw.2017.08.007.","journal-title":"Saf Health Work"},{"issue":"4","key":"77_CR17","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1177\/15443167100340","volume":"34","author":"JF Polak","year":"2010","unstructured":"Polak JF, Baker J, Jones A, Haracznak S, Harrington A. Possible associations between scan quality and pain during ultrasound scanning: results from the society for vascular ultrasound 2009 survey on ergonomics. J Vascular Ultrasound. 2010;34(4):171\u20134. https:\/\/doi.org\/10.1177\/15443167100340.","journal-title":"J Vascular Ultrasound"},{"issue":"4","key":"77_CR18","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1002\/sono.12319","volume":"9","author":"AM Clark","year":"2022","unstructured":"Clark AM, Quinton AE, Alphonse J. Australian cardiac sonographers\u2019 use of industry guidelines when performing a transthoracic echocardiogram. Sonography. 2022;9(4):156\u201365. https:\/\/doi.org\/10.1002\/sono.12319.","journal-title":"Sonography"}],"container-title":["Echo Research &amp; Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44156-025-00077-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s44156-025-00077-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44156-025-00077-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,15]],"date-time":"2025-06-15T23:02:05Z","timestamp":1750028525000},"score":1,"resource":{"primary":{"URL":"https:\/\/echo.biomedcentral.com\/articles\/10.1186\/s44156-025-00077-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,16]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["77"],"URL":"https:\/\/doi.org\/10.1186\/s44156-025-00077-0","relation":{},"ISSN":["2055-0464"],"issn-type":[{"value":"2055-0464","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,16]]},"assertion":[{"value":"17 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Prior to commencing the study, the methodology was subjected to an ethical review by the University of South Australia Human Research Ethics Committee (ID: 203491). To ensure informed consent, potential participants were provided with verbal and written information outlining the study\u2019s aims and how data collected would be used and stored. Ethical considerations that were considered included: the privacy of participant personal information (maintained through de-identification of ultrasound images and video recordings); Vulnerable populations with participants under 18 years of age were excluded from the study. Potential existed for detection of unknown heart abnormalities during cardiac ultrasound image acquisition. GP details were collected at the time of consent and if the senior sonographer suspected an abnormality, the participant was advised appropriately, and their GP informed to ensure that an official referral for a cardiac ultrasound was performed and assessed by a cardiologist.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"As part of the informed consent process, participants were informed that the group, de-identified data would be published to disseminate the scientific results.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"At the time of completion of this project the main author (KH) was a Master of Research student at University of South Australia and employed as a Clinical Applications Specialist for GE HealthCare Australia.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11"}}