{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:21:34Z","timestamp":1790788894596,"version":"4.1.0"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T00:00:00Z","timestamp":1700611200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T00:00:00Z","timestamp":1700611200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Gen Thorac Cardiovasc Surg Cases"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Various complications of permanent pacemaker implantation have been reported. However, late pacemaker lead-related myocardial perforation rarely occurs. Conservative treatment is generally selected, if possible, but open heart surgery or catheter lead removal should be considered in symptomatic patients. We herein describe a patient who was successfully treated by pericardial repair and coverage for late pacemaker lead-related atrial perforation and pneumothorax.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A woman in her 80s who had undergone permanent pacemaker implantation 2 years previously visited our hospital because of dyspnea. She had also been treated for right pneumothorax 1 year previously. A chest radiograph and computed tomography scan showed right pneumothorax and pericardial emphysema with no effusion. Because similar findings had been obtained at the previous onset of pneumothorax, we suspected delayed myocardial perforation and lung injury due to the screw-in lead in the right atrium. No myocardial bleeding, cardiac tamponade, or pacing failure was present. The cardiovascular surgeon judged that open-heart lead extraction would be difficult because of the patient\u2019s poor performance status; therefore, thoracoscopic pericardial repair with an expanded polytetrafluoroethylene sheet and coverage with anterior mediastinal adipose tissue was attempted to prevent recurrent pneumothorax. The patient was successfully treated without lead extraction or open heart surgery. At 1.5 years postoperatively, she had developed no recurrence of pneumothorax or pacing failure.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Pericardial repair and coverage can be an effective strategy for pacemaker lead-related pneumothorax without pacing failure or bleeding.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s44215-023-00117-3","type":"journal-article","created":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T14:02:27Z","timestamp":1700661747000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Successful pericardial repair and coverage for late pacemaker lead-related atrial perforation and pneumothorax: a case report"],"prefix":"10.1186","volume":"2","author":[{"given":"Yoshiyuki","family":"Maruya","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takumi","family":"Yamaura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hayato","family":"Mine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4457-1863","authenticated-orcid":false,"given":"Hiroyuki","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,11,22]]},"reference":[{"key":"117_CR1","first-page":"768","volume":"54","author":"T Tsuchida","year":"2022","unstructured":"Tsuchida T, Suzuki T, Yoshida M, Furubayashi K, Yano K, Terashita K, et al. Pacemaker Implantation techniques and countermeasures against postoperative complications-study of 502 consecutive case. Shinzo. 2022;54:768\u201375.","journal-title":"Shinzo."},{"key":"117_CR2","first-page":"626","volume":"51","author":"K Yoshitake","year":"2019","unstructured":"Yoshitake K, Namiki A, Kosaki R, Inokuchi K, Ochi A, Sekimoto T, et al. Complications after permanent pacemaker implantation; pneumothrax, pneumopericardium and pneumomediastinum. Shinzo. 2019;51:626\u201330.","journal-title":"Shinzo."},{"key":"117_CR3","first-page":"239","volume":"58","author":"T Norikane","year":"2013","unstructured":"Norikane T, Murota M, Itou S, Arai H, Yamamoto Y, Toyama Y, et al. A case of pneumothorax in contralateral side of venous approach after pacemaker implantation. Jpn J Clin Radiol. 2013;58:239\u201342.","journal-title":"Jpn J Clin Radiol."},{"key":"117_CR4","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.joa.2017.03.003","volume":"33","author":"KJ IshizueN","year":"2017","unstructured":"IshizueN KJ, Niwano N, Ako J. Subacute pneumothorax contralateral to the venous access site associated with atrial lead perforation in a patient who was receiving corticosteroid therapy. J Arrhythmia. 2017;33:335\u20137.","journal-title":"J Arrhythmia."},{"key":"117_CR5","first-page":"309","volume":"118","author":"H Nozaki","year":"2004","unstructured":"Nozaki H, Miyajima S, Yamaura M, Kazama R. A case of contralateral pneumothorax associated with pacemaker implantation using screw-in atrial lead. Niigata Med J. 2004;118:309\u201314.","journal-title":"Niigata Med J."},{"key":"117_CR6","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/j.jccase.2021.05.008","volume":"24","author":"U Hisashi","year":"2021","unstructured":"Hisashi U, Shin Y, Naosumi S, Sachiko Y, Ayaka A, Hiroe T, et al. Repair of pacemaker lead-induced right ventricular perforation via a left mini-thoracotomy. J Cardiol Cases. 2021;24:307\u20139.","journal-title":"J Cardiol Cases."},{"key":"117_CR7","first-page":"70","volume":"8","author":"P Justyna","year":"2012","unstructured":"Justyna P, Jacek L, Anna R, Jacek M. Heart perforation in patients with permanent cardiac pacing\u2013pilot personal observations. Arch Med Sci. 2012;8:70\u20134.","journal-title":"Arch Med Sci."},{"key":"117_CR8","first-page":"637","volume":"20","author":"M Fujimori","year":"2004","unstructured":"Fujimori M, Tamura A, Simizu T, Akagi T, Tanabe M, Sasahashi N, et al. Left pneumothorax resulting from right ventricular screw-in lead as a late complication after permanent pacemaker implantation: a case report. J Arrhythmia. 2004;20:637\u201341.","journal-title":"J Arrhythmia."},{"key":"117_CR9","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1111\/j.1540-8159.2005.40003.x","volume":"28","author":"M Khan","year":"2005","unstructured":"Khan M, Joseph G, Khaykin Y, Ziada K, Wilkoff B. Delayed lead perforation: a disturbing trend. Pace. 2005;28:251\u20133.","journal-title":"Pace."},{"key":"117_CR10","doi-asserted-by":"crossref","unstructured":"Marwan M, Jana G, Alaa A. Late perforation by cardiac implantable electronic device leads: clinical presentation, diagnostic clues, and management. Clin Cardiol. 2010;33;8:466\u2013475.","DOI":"10.1002\/clc.20803"},{"key":"117_CR11","first-page":"39","volume":"15","author":"K Ishikawa","year":"1999","unstructured":"Ishikawa K, Cida K, Taniguchi T, Watanabe C, Okawa S. Myocardial perforation and\/or penetration by a permanent endocardial electrode of the pacemaker in autopsy cases. J Arrhythmia. 1999;15:39\u201344.","journal-title":"J Arrhythmia."}],"container-title":["General Thoracic and Cardiovascular Surgery Cases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-023-00117-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s44215-023-00117-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-023-00117-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T14:06:30Z","timestamp":1700661990000},"score":1,"resource":{"primary":{"URL":"https:\/\/gtcscases.biomedcentral.com\/articles\/10.1186\/s44215-023-00117-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,22]]},"references-count":11,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["117"],"URL":"https:\/\/doi.org\/10.1186\/s44215-023-00117-3","relation":{},"ISSN":["2731-6203"],"issn-type":[{"value":"2731-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,22]]},"assertion":[{"value":"5 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"102"}}