{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T15:09:52Z","timestamp":1788448192606,"version":"build-2803163510"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,2,22]],"date-time":"2024-02-22T00:00:00Z","timestamp":1708560000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,22]],"date-time":"2024-02-22T00:00:00Z","timestamp":1708560000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Gen Thorac Cardiovasc Surg Cases"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Stent graft-induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) is a serious adverse event which leads to stent graft migration and rupture. SINE is known to be more frequent in cases of chronic dissection and oversizing. However, few studies have evaluated the influence of hemodynamic stress on SINE in patients with chronic dissection. Here, we report a rare case of TEVAR for chronic dissection with a dissection stent, inducing SINE 6 years after the first surgery. In addition, we analyze the hemodynamic stress for the aortic event using computational fluid dynamics (CFD) analysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 69-year-old male underwent TEVAR with left subclavian artery debranching for chronic type B aortic dissection, using a stent graft and dissection stent. The postoperative course was uneventful, but follow-up computed tomography (CT) showed that the stent graft and bare-metal stent had dislodged 4 years after surgery. The gap between the bare-metal stent and the stent graft increased over time, and the proximal edge of the bare-metal stent led to SINE at the descending aorta 6 years after surgery. We performed reintervention to cover the SINE. The patient recovered well and was discharged at 6 days postoperatively. He is currently in good condition 6 months after reintervention. CFD analysis of the patient\u2019s CT image suggested that the local change in wall shear stress at the stent graft and dissection stent might be related to the aortic event.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Hemodynamic stress is a factor affecting SINE and device migration. CFD may be useful for evaluating patient-specific risk of aortic events.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s44215-024-00146-6","type":"journal-article","created":{"date-parts":[[2024,2,22]],"date-time":"2024-02-22T15:02:21Z","timestamp":1708614141000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Stent-induced new entry and device migration associated with hemodynamic stress after thoracic endovascular aortic repair for type B chronic aortic dissection using computational fluid dynamics analysis: a case report"],"prefix":"10.1186","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4005-8229","authenticated-orcid":false,"given":"Itaru","family":"Hosaka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Uzuka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riko","family":"Umeta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiko","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,22]]},"reference":[{"key":"146_CR1","doi-asserted-by":"publisher","first-page":"6385","DOI":"10.1007\/s00330-019-06282-w","volume":"29","author":"U Asenbaum","year":"2019","unstructured":"Asenbaum U, Schoder M, Schwartz E, Langs G, Baltzer P, Wolf F, et al. Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks. Eur Radiol. 2019;29:6385\u201395. https:\/\/doi.org\/10.1007\/s00330-019-06282-w.","journal-title":"Eur Radiol."},{"key":"146_CR2","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1177\/15266028221075548","volume":"30","author":"K Kobayashi","year":"2023","unstructured":"Kobayashi K, Yamashita A, Kuroda Y, Nakai S, Arai S, Uchida T. Unexpected bare metal stent migration associated with aortic remodeling after PETTICOAT technique for aortic dissection. J Endovasc Ther. 2023;30:302\u20136. https:\/\/doi.org\/10.1177\/15266028221075548.","journal-title":"J Endovasc Ther."},{"key":"146_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3233\/CH-200996","volume":"78","author":"F Ashraf","year":"2021","unstructured":"Ashraf F, Ambreen T, Park CW, Kim DI. Comparative evaluation of ballet-type and conventional stent graft configurations for endovascular aneurysm repair: a CFD analysis. Clin Hemorheol Microcirc. 2021;78:1\u201327. https:\/\/doi.org\/10.3233\/CH-200996.","journal-title":"Clin Hemorheol Microcirc."},{"key":"146_CR4","doi-asserted-by":"publisher","first-page":"869505","DOI":"10.3389\/fcvm.2022.869505","volume":"9","author":"X Zhang","year":"2022","unstructured":"Zhang X, Chen D, Wu M, Dong H, Wan Z, Jia H, et al. Functional evaluation of embedded modular single-branched stent graft: application to type B aortic dissection with aberrant right subclavian artery. Front Cardiovasc Med. 2022;9:869505. https:\/\/doi.org\/10.3389\/fcvm.2022.869505.","journal-title":"Front Cardiovasc Med."},{"key":"146_CR5","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1177\/152660280200900606","volume":"9","author":"IV Mohan","year":"2002","unstructured":"Mohan IV, Harris PL, Van Marrewijk CJ, Laheij RJ, How TV. Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair. J Endovasc Ther. 2002;9:748\u201355. https:\/\/doi.org\/10.1177\/152660280200900606.","journal-title":"J Endovasc Ther."},{"key":"146_CR6","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.ejvs.2013.11.015","volume":"47","author":"H Roos","year":"2014","unstructured":"Roos H, Ghaffari M, Falkenberg M, Chernoray V, Jeppsson A, Nilsson H. Displacement forces in iliac landing zones and stent graft interconnections in endovascular aortic repair: an experimental study. Eur J Vasc Endovasc Surg. 2014;47:262\u20137. https:\/\/doi.org\/10.1016\/j.ejvs.2013.11.015.","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"146_CR7","doi-asserted-by":"publisher","first-page":"281","DOI":"10.21037\/jtd-22-1206","volume":"15","author":"A Osswald","year":"2023","unstructured":"Osswald A, Weymann A, Tsagakis K, Zubarevich A, Thielmann M, Schmack B. First insights into the role of wall shear stress in the development of a distal stent graft induced new entry through computational fluid dynamics simulations. J Thorac Dis. 2023;15:281\u201390. https:\/\/doi.org\/10.21037\/jtd-22-1206.","journal-title":"J Thorac Dis."},{"key":"146_CR8","doi-asserted-by":"publisher","first-page":"1458","DOI":"10.1016\/j.medengphy.2016.09.011","volume":"38","author":"F Stefanov","year":"2016","unstructured":"Stefanov F, McGloughlin T, Morris L. A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms. Med Eng Phys. 2016;38:1458\u201373. https:\/\/doi.org\/10.1016\/j.medengphy.2016.09.011.","journal-title":"Med Eng Phys."},{"key":"146_CR9","doi-asserted-by":"publisher","first-page":"311.e1","DOI":"10.1016\/j.avsg.2018.12.098","volume":"59","author":"\u00c1 Duque Santos","year":"2019","unstructured":"Duque Santos \u00c1, Reyes Valdivia A, Gordillo Alguacil S, Oca\u00f1a Guaita J, Gandarias ZC. Symptomatic aortic bare-metal stent fracture after PETTICOAT technique for complicated type B aortic dissection. Ann Vasc Surg. 2019;59:311.e1\u20134. https:\/\/doi.org\/10.1016\/j.avsg.2018.12.098.","journal-title":"Ann Vasc Surg."},{"key":"146_CR10","doi-asserted-by":"publisher","first-page":"270","DOI":"10.3400\/avd.cr.17-00044","volume":"10","author":"T Shintani","year":"2017","unstructured":"Shintani T, Atsuta K, Saito T. Successful hybrid treatment of stent-graft migration caused by type B aortic dissection after endovascular aortic aneurysm repair: a case report. Ann Vasc Dis. 2017;10:270\u20133. https:\/\/doi.org\/10.3400\/avd.cr.17-00044.","journal-title":"Ann Vasc Dis."},{"key":"146_CR11","doi-asserted-by":"publisher","first-page":"0245011","DOI":"10.1115\/1.4038751","volume":"140","author":"H Lan","year":"2018","unstructured":"Lan H, Updegrove A, Wilson NM, Maher GD, Shadden SC, Marsden AL. A re-engineered software Interface and workflow for the open-source SimVascular cardiovascular modeling package. J Biomech Eng. 2018;140:0245011\u2013111. https:\/\/doi.org\/10.1115\/1.4038751.","journal-title":"J Biomech Eng."},{"key":"146_CR12","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1299\/jsmec.48.459","volume":"48","author":"S Yokosawa","year":"2005","unstructured":"Yokosawa S, Nakamura M, Wada S, Isoda H, Takeda H, Yamaguchi T. Quantitative measurements on the human ascending aortic flow using 2D cine phase-contrast magnetic resonance imaging. JSME Int J Ser C. 2005;48:459\u201367. https:\/\/doi.org\/10.1299\/jsmec.48.459.","journal-title":"JSME Int J Ser C."},{"key":"146_CR13","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1016\/j.jvs.2016.09.022","volume":"65","author":"H Jang","year":"2017","unstructured":"Jang H, Kim MD, Kim GM, Won JY, Ko YG, Choi D, et al. Risk factors for stent graft-induced new entry after thoracic endovascular aortic repair for Stanford type B aortic dissection. J Vasc Surg. 2017;65:676\u201385. https:\/\/doi.org\/10.1016\/j.jvs.2016.09.022.","journal-title":"J Vasc Surg."},{"key":"146_CR14","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.avsg.2018.10.024","volume":"58","author":"B Nasr","year":"2019","unstructured":"Nasr B, Savean J, Albert B, Badra A, Braesco J, Nonent M, et al. Thoracic stent-graft migration: the role of the geometric modifications of the stent-graft at 3 years. Ann Vasc Surg. 2019;58:16\u201323. https:\/\/doi.org\/10.1016\/j.avsg.2018.10.024.","journal-title":"Ann Vasc Surg."},{"key":"146_CR15","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.jvs.2003.09.022","volume":"39","author":"WC Sternbergh 3rd","year":"2004","unstructured":"Sternbergh WC 3rd, Money SR, Greenberg RK, Chuter TA, Investigators Z. Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the zenith multicenter trial. J Vasc Surg. 2004;39:20\u20136. https:\/\/doi.org\/10.1016\/j.jvs.2003.09.022.","journal-title":"J Vasc Surg."},{"key":"146_CR16","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.ejvs.2017.06.012","volume":"54","author":"A Osswald","year":"2017","unstructured":"Osswald A, Karmonik C, Anderson JR, Rengier F, Karck M, Engelke J, et al. Elevated wall shear stress in aortic type B dissection may relate to retrograde aortic type a dissection: a computational fluid dynamics pilot study. Eur J Vasc Endovasc Surg. 2017;54:324\u201330. https:\/\/doi.org\/10.1016\/j.ejvs.2017.06.012.","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"146_CR17","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.jbiomech.2019.07.034","volume":"94","author":"P Tasso","year":"2019","unstructured":"Tasso P, Lodi Rizzini M, Raptis A, Matsagkas M, De Nisco G, Gallo D, et al. In-stent graft helical flow intensity reduces the risk of migration after endovascular aortic repair. J Biomech. 2019;94:170\u20139. https:\/\/doi.org\/10.1016\/j.jbiomech.2019.07.034.","journal-title":"J Biomech."},{"key":"146_CR18","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1007\/s10439-016-1762-8","volume":"45","author":"A Updegrove","year":"2017","unstructured":"Updegrove A, Wilson NM, Merkow J, Lan H, Marsden AL, Shadden SC. SimVascular: An Open Source Pipeline for Cardiovascular Simulation. Ann Biomed Eng. 2017;45:525\u201341. https:\/\/doi.org\/10.1007\/s10439-016-1762-8.","journal-title":"Ann Biomed Eng."}],"container-title":["General Thoracic and Cardiovascular Surgery Cases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-024-00146-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s44215-024-00146-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-024-00146-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,22]],"date-time":"2024-02-22T15:05:41Z","timestamp":1708614341000},"score":1,"resource":{"primary":{"URL":"https:\/\/gtcscases.biomedcentral.com\/articles\/10.1186\/s44215-024-00146-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,22]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["146"],"URL":"https:\/\/doi.org\/10.1186\/s44215-024-00146-6","relation":{},"ISSN":["2731-6203"],"issn-type":[{"value":"2731-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,22]]},"assertion":[{"value":"30 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The informed consent was obtained from the patient.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"8"}}