{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T00:44:55Z","timestamp":1740185095020,"version":"3.37.3"},"reference-count":5,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,31]],"date-time":"2024-12-31T00:00:00Z","timestamp":1735603200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,31]],"date-time":"2024-12-31T00:00:00Z","timestamp":1735603200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Gen Thorac Cardiovasc Surg Cases"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Takayasu arteritis is a large-vessel vasculitis, in addition to giant cell arteritis. Various post-operative complications associated with the cardiac macrovasculature have been reported. Detachment of the prosthetic valve, pseudoaneurysm formation, and dilatation of the aortic root are well-known post-operative complications associated with vasculitis syndromes, including Takayasu arteritis. Here, we report a rare complication involving aortic bioprosthetic valve dislodgement in the left ventricular outflow tract due to Takayasu arteritis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 76-year-old female underwent aortic valve replacement with a 21-mm Carpentier\u2013Edwards Perimount valve for severe aortic regurgitation and a coronary artery bypass graft from the left internal thoracic artery to the left anterior descending artery for ischemic heart disease. Fourteen years after the initial surgery, echocardiography revealed severe aortic valve sclerosis due to structural valve deterioration of the bioprosthesis. Upon scrutiny, the bioprosthetic aortic valve was found to have dislodged into the left ventricular outflow tract. We performed re-implantation of the bioprosthetic aortic valve and replacement of the ascending aorta.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Although dislodgement of the bioprosthetic aortic valve is an extremely rare complication associated with Takayasu arteritis, the possibility that it could occur should be considered when treating the post-operative patients.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s44215-024-00182-2","type":"journal-article","created":{"date-parts":[[2024,12,31]],"date-time":"2024-12-31T10:18:45Z","timestamp":1735640325000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Reoperation for chronological complete dislodgement of the bioprosthetic aortic valve into the left ventricle due to Takayasu arteritis"],"prefix":"10.1186","volume":"3","author":[{"given":"Shogo","family":"Matsunaga","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiromichi","family":"Sonoda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoki","family":"Ushijima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meikun","family":"Kan-o","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0865-0169","authenticated-orcid":false,"given":"Akira","family":"Shiose","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,12,31]]},"reference":[{"key":"182_CR1","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/0741-5214(90)90045-C","volume":"12","author":"F Weaver","year":"1990","unstructured":"Weaver F, Yellin A, Campen D, et al. Surgical procedures in the management of Takayasu\u2019s arteritis. J Vasc Surg. 1990;12:429\u201339.","journal-title":"J Vasc Surg"},{"key":"182_CR2","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/j.jcin.2011.03.016","volume":"4","author":"N Piazza","year":"2011","unstructured":"Piazza N, Bleiziffer S, Lange R, et al. Transcatheter Aortic Valve Implantation for Failing Surgical Aortic Bioprosthetic Valve. J Am Coll Cardiol Intv. 2011;4:721\u201332.","journal-title":"J Am Coll Cardiol Intv"},{"key":"182_CR3","first-page":"I222","volume":"80","author":"A Suzuki","year":"1989","unstructured":"Suzuki A, Amano J, Tanaka H, et al. Surgical consideration of aortitis involving the aortic root. Circulation. 1989;80:I222\u201332.","journal-title":"Circulation"},{"key":"182_CR4","doi-asserted-by":"publisher","first-page":"1950","DOI":"10.1016\/j.athoracsur.2007.07.025","volume":"84","author":"O Adachi","year":"2007","unstructured":"Adachi O, Saiki Y, Tabayashi K, et al. Surgical Management of Aortic Regurgitation Associated With Takayasu Arteritis and Other Forms of Aortitis. Ann Thorac Surg. 2007;84:1950\u20134.","journal-title":"Ann Thorac Surg"},{"key":"182_CR5","doi-asserted-by":"publisher","first-page":"3707","DOI":"10.1161\/CIRCULATIONAHA.105.535724","volume":"112","author":"K Matsuura","year":"2005","unstructured":"Matsuura K, Ogino H, Kitamura S, et al. Surgical Treatment of Aortic Regurgitation due to Takayasu Arteritis: Long-Term Morbidity and Mortality. Circulation. 2005;112:3707\u201312.","journal-title":"Circulation"}],"container-title":["General Thoracic and Cardiovascular Surgery Cases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-024-00182-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s44215-024-00182-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-024-00182-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,31]],"date-time":"2024-12-31T11:09:08Z","timestamp":1735643348000},"score":1,"resource":{"primary":{"URL":"https:\/\/gtcscases.biomedcentral.com\/articles\/10.1186\/s44215-024-00182-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,31]]},"references-count":5,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["182"],"URL":"https:\/\/doi.org\/10.1186\/s44215-024-00182-2","relation":{},"ISSN":["2731-6203"],"issn-type":[{"type":"electronic","value":"2731-6203"}],"subject":[],"published":{"date-parts":[[2024,12,31]]},"assertion":[{"value":"5 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The research related to human use has been complied with all the relevant national regulations, institutional policies and in accordance the tenets of the Helsinki Declaration, and has been approved by the authors' institutional review board or equivalent committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The author(s) declared no potential conflicts of interest with respect to the research, authorship, and\/or publication of this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"58"}}