{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T16:10:53Z","timestamp":1760458253952,"version":"build-2065373602"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T00:00:00Z","timestamp":1760400000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T00:00:00Z","timestamp":1760400000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Gen Thorac Cardiovasc Surg Cases"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Total arch replacement with frozen elephant trunk (FET) has been reported to be associated with favorable aortic remodeling when used for aortic dissection. However, several complications associated with FET have been reported, including distal stent graft-induced new entry (dSINE), which potentially results in aortic rupture and late mortality. Frozenix Partial ET (Japan Lifeline Inc., Tokyo, Japan) is a unique FET device that has a non-stent zone at the distal 2\u00a0cm end to decrease the radial force to lower the incidence of dSINE. Owing to its novelty, there are few preceding literatures regarding its efficacy and complications.<\/jats:p>\n            <jats:p>In this report, we present a case of an unanticipated complication arising from the use of Frozenix Partial ET subsequent to the initiation of extracorporeal membrane oxygenation (ECMO).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Case presentation<\/jats:title>\n            <jats:p>A 54-year-old male diagnosed with Stanford type A acute aortic dissection underwent emergency total aortic arch replacement, frozen elephant trunk with Frozenix partial ET (Japan Lifeline Inc., Tokyo, Japan), the Bentall procedure, and coronary artery bypass grafting.\n<\/jats:p>\n            <jats:p>The patient developed cardiogenic shock, requiring extracorporeal membrane oxygenation with left common femoral artery and vein cannulation on postoperative day 1. Despite adequate ECMO flow, high doses of catecholamines were required to maintain blood pressure measured at the right radial artery. Transesophageal echocardiography revealed stenosis of the distal part of the FET presumably due to retrograde perfusion from the femoral artery. The addition of left axillary artery cannulation improved systemic circulation, reducing the dose of catecholamine.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Although designed to reduce the risk of dSINE, Frozenix Partial ET may induce unforeseen complications. Particularly, its non-stent distal part can become stenotic under conditions of retrograde perfusion. Surgeons should carefully choose where to cannulate in patients with this device requiring redo surgery or ECMO support.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s44215-025-00223-4","type":"journal-article","created":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T15:45:28Z","timestamp":1760456728000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Unanticipated stenosis of the distal edge of frozen elephant trunk caused by retrograde perfusion: A case report"],"prefix":"10.1186","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-0734-7333","authenticated-orcid":false,"given":"Taiki","family":"Niki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiro","family":"Esaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,14]]},"reference":[{"issue":"3","key":"223_CR1","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1093\/ejcts\/ezz104","volume":"56","author":"Y Inoue","year":"2019","unstructured":"Inoue Y, Matsuda H, Omura A, Seike Y, Uehara K, Sasaki H, et al. Comparative study of the frozen elephant trunk and classical elephant trunk techniques to supplement total arch replacement for acute type A aortic dissection. Eur J Cardiothorac Surg. 2019;56(3):579\u201386.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"5","key":"223_CR2","doi-asserted-by":"publisher","first-page":"ezae176","DOI":"10.1093\/ejcts\/ezae176","volume":"65","author":"NA Papakonstantinou","year":"2024","unstructured":"Papakonstantinou NA, Martinez-Lopez D, Chung JC. The frozen elephant trunk: seeking a more definitive treatment for acute type A aortic dissection. Eur J Cardiothorac Surg. 2024;65(5):ezae176.","journal-title":"Eur J Cardiothorac Surg."},{"issue":"6","key":"223_CR3","doi-asserted-by":"publisher","first-page":"1104","DOI":"10.21037\/cdt-23-300","volume":"13","author":"F Kayali","year":"2023","unstructured":"Kayali F, Chikhal R, Agbobu T, Jubouri M, Patel R, Chen EP, Mohammed I, Bashir M. Evidence-based frozen elephant trunk practice: a narrative review. Cardiovasc Diagn Ther. 2023;13(6):1104\u201317.","journal-title":"Cardiovasc Diagn Ther"},{"issue":"9","key":"223_CR4","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1111\/jocs.12598","volume":"30","author":"F Settepani","year":"2015","unstructured":"Settepani F, Cappai A, Basciu A, Barbone A, Citterio E, Ornaghi D, et al. Hybrid versus conventional treatment of acute type A aortic dissection. J Card Surg. 2015;30(9):707\u201313.","journal-title":"J Card Surg"},{"issue":"4","key":"223_CR5","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1016\/j.jtcvs.2017.04.088","volume":"154","author":"WG Ma","year":"2017","unstructured":"Ma WG, Zhang W, Zhu JM, Ziganshin BA, Zhi AH, Zheng J, et al. Long-term outcomes of frozen elephant trunk for type A aortic dissection in patients with Marfan syndrome. J Thorac Cardiovasc Surg. 2017;154(4):1175-1189.e2.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"223_CR6","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1053\/j.semtcvs.2021.03.049","volume":"34","author":"A Hage","year":"2022","unstructured":"Hage A, Hage F, Dagenais F, Ouzounian M, Chung J, El-Hamamsy I, et al. Frozen elephant trunk for aortic arch reconstruction is associated with reduced mortality as compared to conventional techniques. Semin Thorac Cardiovasc Surg. 2022;34(2):386\u201392.","journal-title":"Semin Thorac Cardiovasc Surg"},{"issue":"6","key":"223_CR7","doi-asserted-by":"publisher","first-page":"1550","DOI":"10.1016\/S0022-5223(03)00045-X","volume":"125","author":"M Karck","year":"2003","unstructured":"Karck M, Chavan A, Hagl C, Friedrich H, Galanski M, Haverich A. The frozen elephant trunk technique: a new treatment for thoracic aortic aneurysms. J Thorac Cardiovasc Surg. 2003;125(6):1550\u20133.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"223_CR8","doi-asserted-by":"publisher","first-page":"408","DOI":"10.21037\/cdt-22-234","volume":"13","author":"G Murana","year":"2023","unstructured":"Murana G, Costantino A, Campanini F, Fiaschini C, Buia F, Mariani C, et al. Distal stent graft-induced new entry (dSINE) after frozen elephant trunk: a scoping review. Cardiovasc Diagn Ther. 2023;13(2):408\u201317.","journal-title":"Cardiovasc Diagn Ther"},{"issue":"5","key":"223_CR9","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1016\/j.athoracsur.2020.02.079","volume":"110","author":"M Czerny","year":"2020","unstructured":"Czerny M, Eggebrecht H, Rousseau H, Mouroz PR, Janosi RA, Lescan M, et al. Distal stent graft-induced new entry after TEVAR or FET: insights into a new disease from EuREC. Ann Thorac Surg. 2020;110(5):1494\u2013500.","journal-title":"Ann Thorac Surg"},{"key":"223_CR10","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.875078","volume":"9","author":"M Jubouri","year":"2022","unstructured":"Jubouri M, Kayali F, Saha P, Ansari DM, Rezaei Y, Tan SZCP, et al. Incidence of distal stent graft induced new entry vs. aortic remodeling associated with frozen elephant trunk. Front Cardiovasc Med. 2022;9:875078 (Mar 10;).","journal-title":"Front Cardiovasc Med"},{"key":"223_CR11","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.jtcvs.2018.10.060","volume":"157","author":"GC Hughes","year":"2019","unstructured":"Hughes GC. Stent graft-induced new entry tear (SINE): intentionaland NOT. J Thorac Cardiovasc Surg. 2019;157:101-106.e3.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"223_CR12","first-page":"43","volume":"85","author":"RA J\u00e1nosi","year":"2015","unstructured":"J\u00e1nosi RA, Tsagakis K, Bettin M, Kahlert P, Horacek M, Al-Rashid F, Schlosser T, Jakob H, Eggebrecht H, Erbel R. Thoracic aortic aneurysm expansion due to late distal stent graft-induced new entry. Catheter Cardiovasc Interv. 2015;85(2):43\u201353.","journal-title":"Catheter Cardiovasc Interv."},{"issue":"3","key":"223_CR13","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1016\/j.athoracsur.2018.09.043","volume":"107","author":"Q Li","year":"2019","unstructured":"Li Q, Ma WG, Zheng J, Xu SD, Chen Y, Liu YM, et al. Distal stent graft-induced new entry after TEVAR of type B aortic dissection: experience in 15 years. Ann Thorac Surg. 2019;107(3):718\u201324.","journal-title":"Ann Thorac Surg"},{"key":"223_CR14","doi-asserted-by":"crossref","unstructured":"D'cruz RT, Syn N, Wee I, Choong AMTL; Singapore Vascular Surgical Collaborative (SingVaSC). Risk factors for distal stent graft-induced new entry in type B aortic dissections: Systematic review and meta-analysis. J Vasc Surg. 2019;70(5):1682\u20131693.e1.","DOI":"10.1016\/j.jvs.2019.02.040"},{"key":"223_CR15","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.xjtc.2022.02.018","volume":"13","author":"Y Ohashi","year":"2022","unstructured":"Ohashi Y, Washiyama N, Tsuda K, Shiiya N. Dynamic obstruction of the elephant trunk caused by vortex flow in the descending aorta. JTCVS Tech. 2022;13:22\u20134.","journal-title":"JTCVS Tech"}],"container-title":["General Thoracic and Cardiovascular Surgery Cases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-025-00223-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s44215-025-00223-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-025-00223-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T15:45:29Z","timestamp":1760456729000},"score":1,"resource":{"primary":{"URL":"https:\/\/gtcscases.biomedcentral.com\/articles\/10.1186\/s44215-025-00223-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,14]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["223"],"URL":"https:\/\/doi.org\/10.1186\/s44215-025-00223-4","relation":{},"ISSN":["2731-6203"],"issn-type":[{"value":"2731-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,14]]},"assertion":[{"value":"20 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Our institution does not require ethical approval to publish an anonymous case report.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"41"}}