{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T21:19:15Z","timestamp":1761167955116,"version":"build-2065373602"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:00:00Z","timestamp":1761004800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:00:00Z","timestamp":1761004800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Gen Thorac Cardiovasc Surg Cases"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A pulmonary artery catheter (PAC) is widely used to manage various health conditions during cardiac surgery. However, it can cause rare but life-threatening complications such as pulmonary artery injury. Although surgical treatment is often required for pulmonary artery injury caused by a PAC, detailed reports of the surgical management of this complication are lacking. We present a case of PAC-induced pulmonary artery injury that occurred during cardiac surgery and was successfully managed with surgical treatment without pulmonary resection.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>A 76-year-old woman with severe heart valve disease underwent replacement of the aortic and mitral valves and surgical repair of the tricuspid valve using a PAC. Massive bleeding into the airway occurred during withdrawal from cardiopulmonary bypass. Fluoroscopic contrast injection through the PAC identified a PAC-induced tear in the left pulmonary artery as the cause of the bleeding. Opening of the left fourth intercostal space was performed without changing the supine position of the patient. Bleeding was successfully controlled by ligating the damaged branch of the pulmonary artery (A6c) and suturing the roots of the peripheral pulmonary arteries (A9 and A10) without performing lung resection. The patient recovered without complications and was discharged in good condition.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Although PAC-induced pulmonary artery injury is associated with a high mortality rate, the patient survived cardiac surgery with lung preservation in the supine position.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s44215-025-00227-0","type":"journal-article","created":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T11:19:34Z","timestamp":1761045574000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Surgical management for catheter-induced pulmonary artery injury during cardiac surgery: a case report"],"prefix":"10.1186","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-2481-4604","authenticated-orcid":false,"given":"Harunobu","family":"Sasanuma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaaki","family":"Nagano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mamoru","family":"Muto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuo","family":"Maeyashiki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuyuki","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Nagasaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,21]]},"reference":[{"key":"227_CR1","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1136\/thx.34.4.550","volume":"34","author":"MM Deren","year":"1979","unstructured":"Deren MM, Barash PG, Hammond GL, et al. Perforation of the pulmonary artery requiring pneumonectomy after the use of a flow-directed (Swan-Ganz) catheter. Thorax. 1979;34:550\u20133.","journal-title":"Thorax"},{"key":"227_CR2","first-page":"998","volume":"99","author":"American Society of Anesthesiologisits Task Force on pulmonary Artery Catheterization","year":"2003","unstructured":"American Society of Anesthesiologisits Task Force on pulmonary Artery Catheterization. Practice gidelines for pulmonary artery catheterization. Anesthsiology. 2003;99:998\u20131014.","journal-title":"Anesthsiology"},{"key":"227_CR3","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1097\/ACO.0b013e32801158a9","volume":"20","author":"JS Bussi\u00e8res","year":"2007","unstructured":"Bussi\u00e8res JS. Iatrogenic pulmonary artery rupture. Curr Opin Anaesthesiol. 2007;20:48\u201352.","journal-title":"Curr Opin Anaesthesiol"},{"key":"227_CR4","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1007\/s001340050316","volume":"23","author":"J Tayoro","year":"1997","unstructured":"Tayoro J, Dequin PF, Delhommais A, et al. Rupture of pulmonary artery induced by Swan-Ganz catheter\u202f: success of coil embolization. Intensive Care Med. 1997;23:198\u2013200.","journal-title":"Intensive Care Med"},{"key":"227_CR5","doi-asserted-by":"publisher","first-page":"2056","DOI":"10.1016\/S0003-4975(01)03244-1","volume":"72","author":"S Sirivella","year":"2001","unstructured":"Sirivella S, Gielchinsky I, Parsonnet V. Management of catheter-induced pulmonary artery perforation: a rare complication in cardiovascular operations. Ann Thorac Surg. 2001;72:2056\u20139.","journal-title":"Ann Thorac Surg"},{"key":"227_CR6","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1093\/icvts\/ivs287","volume":"15","author":"KL Booth","year":"2012","unstructured":"Booth KL, Mercer-Smith G, McConkey C, et al. Catheter-induced pulmonary artery rupture; haemodynamic compromise necessitates surgical repair. Interact Cardiovasc Thorac Surg. 2012;15:531\u20133.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"227_CR7","first-page":"313","volume":"37","author":"S Sekkal","year":"1996","unstructured":"Sekkal S, Cornu E, Christid\u00e8s C, et al. Swan-Ganz catheter induced pulmonary artery perforation during cardiac surgery concerning two cases. J Cardiovasc Surg. 1996;37:313\u20137.","journal-title":"J Cardiovasc Surg"},{"key":"227_CR8","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1007\/BF03015139","volume":"32","author":"BJ Muller","year":"1985","unstructured":"Muller BJ, Gallucci A. Pulmonary artery catheter induced pulmonary artery rupture in patients undergoing cardiac surgery. Can Anaesth Soc J. 1985;32:258\u201364.","journal-title":"Can Anaesth Soc J"},{"key":"227_CR9","first-page":"259","volume":"38","author":"D Reber","year":"1996","unstructured":"Reber D, Aebert H, Keyl PC, et al. Catheter-induced pulmonary artery perforation during cardiac surgery: intraoperative surgical management. Panminerva Med. 1996;38:259\u201361.","journal-title":"Panminerva Med"},{"key":"227_CR10","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1097\/00000658-198106000-00003","volume":"193","author":"TF Kelly Jr","year":"1981","unstructured":"Kelly TF Jr, Morris GC Jr, Crawford ES, et al. Perforation of the pulmonary artery with Swan-Ganz catheters: diagnosis and surgical management. Ann Surg. 1981;193:686\u201392.","journal-title":"Ann Surg"},{"key":"227_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0022-5223(19)39379-1","volume":"82","author":"DD McDaniel","year":"1981","unstructured":"McDaniel DD, Stone JG, Faltas AN, et al. Catheter-induced pulmonary artery hemorrhage Diagnosis and management in cardiac operations. J Thorac Cardiovasc Surg. 1981;82:1\u20134.","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["General Thoracic and Cardiovascular Surgery Cases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-025-00227-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s44215-025-00227-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s44215-025-00227-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T23:04:10Z","timestamp":1761087850000},"score":1,"resource":{"primary":{"URL":"https:\/\/gtcscases.biomedcentral.com\/articles\/10.1186\/s44215-025-00227-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,21]]},"references-count":11,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["227"],"URL":"https:\/\/doi.org\/10.1186\/s44215-025-00227-0","relation":{},"ISSN":["2731-6203"],"issn-type":[{"type":"electronic","value":"2731-6203"}],"subject":[],"published":{"date-parts":[[2025,10,21]]},"assertion":[{"value":"4 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from the patient to publish this case report.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent to publish this article has been obtained from the patient.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"43"}}