{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T02:08:03Z","timestamp":1791857283376,"version":"4.3.4"},"reference-count":34,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2017,5,1]],"date-time":"2017-05-01T00:00:00Z","timestamp":1493596800000},"content-version":"am","delay-in-days":365,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#am"},{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["0721399"],"award-info":[{"award-number":["0721399"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Earthquake Spectra"],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:p>The seismic response of suspended ceiling systems that were shaken at the University at Buffalo; University of Nevada, Reno; and E\u2010Defense facilities is critically assessed in this paper. After presenting a brief description of each experiment, the most repetitive damage observations in all experiments are discussed. Fragility curves are developed for ceiling perimeter connectors, supporting elements, and overall performance of ceiling systems by using 346 combinations of ceiling configurations and shake intensities. The key findings of these curves are the insufficient support of the 7\/8\u2010in. wall angles, unconservative code design capacity of connections for supporting elements, and early damage of ceiling systems because of ceiling\u2010piping interaction. Acceleration amplification factors of ceiling systems with respect to suspending floor are computed. The amplification factors prescribed by the code were found to be unconservative due to the pounding of panels to the ceiling grids and deck vibration in a vertical direction.<\/jats:p>","DOI":"10.1193\/071514eqs109m","type":"journal-article","created":{"date-parts":[[2015,5,4]],"date-time":"2015-05-04T16:50:41Z","timestamp":1430758241000},"page":"881-908","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":47,"title":["Experimental Fragility Analysis of Suspension Ceiling Systems"],"prefix":"10.1002","volume":"32","author":[{"given":"Siavash","family":"Soroushian","sequence":"first","affiliation":[{"name":"Arup 560 Mission Street, 7th Floor San Francisco CA 94105"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esmaeel","family":"Rahmanishamsi","sequence":"additional","affiliation":[{"name":"Arup 560 Mission Street, 7th Floor San Francisco CA 94105"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ki P.","family":"Ryu","sequence":"additional","affiliation":[{"name":"Dept. of Civil, Structural and Environmental Engineering State University of New York at Buffalo 222 Ketter Hall Buffalo NY 14260"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manos","family":"Maragakis","sequence":"additional","affiliation":[{"name":"Arup 560 Mission Street, 7th Floor San Francisco CA 94105"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrei M.","family":"Reinhorn","sequence":"additional","affiliation":[{"name":"Dept. of Civil, Structural and Environmental Engineering State University of New York at Buffalo 222 Ketter Hall Buffalo NY 14260"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,5]]},"reference":[{"key":"e_1_2_10_2_1","unstructured":"ANCO 1983.Seismic Hazard Assessment of Nonstructural Ceiling Components NSF Rep. No. CEE\u20108114155 Culver City CA."},{"key":"e_1_2_10_3_1","unstructured":"American Society of Civil Engineers (ASCE) 2010.Minimum Design Loads for Buildings and Other Structures ASCE\/SEI 7\u201010 Reston VA."},{"key":"e_1_2_10_4_1","unstructured":"ASTM International 2011.Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay\u2010in Panels in Areas Subject to Earthquake Ground Motions. ASTM International ASTM\u2010E580\/E580M\u201011ae1 Volume 04.06 West Conshohocken PA."},{"key":"e_1_2_10_5_1","unstructured":"ASTM International 2013a.Standard Specification for the Manufacture Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay\u2010in Panel Ceilings ASTM C635\/C635M\u201007 West Conshohocken PA."},{"key":"e_1_2_10_6_1","unstructured":"ASTM International 2013b.Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay\u2010In Panels ASTM International ASTM C636\/C636M\u201006 West Conshohocken PA."},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1193\/1.2357626"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)0733-9445(2002)128:4(526)"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)ST.1943\u2010541X.0000922"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1193\/1.1585607"},{"key":"e_1_2_10_11_1","unstructured":"EchevarriaA.ZaghiA. E.SoroushianS.andMaragakisE. M.2012.Seismic fragility of suspended ceiling systems in15th World Conference on Earthquake Engineering (15WCEE) 24\u201328 September 2012 Lisbon Portugal."},{"key":"e_1_2_10_12_1","unstructured":"Federal Emergency Management Agency (FEMA) 2011.Reducing the Risks of Nonstructural Earthquake Damage: A Practical Guide FEMA 74 Redwood City CA."},{"key":"e_1_2_10_13_1","doi-asserted-by":"crossref","unstructured":"GilaniA. S. J.TakhirovS.andTedescoL.2013.Seismic evaluation of suspended ceiling systems using static and dynamic procedures inProceeding of 44th Structures Congress ASCE\/SEI 2\u20134 May 2013 Pittsburgh PA.","DOI":"10.1061\/9780784412848.134"},{"key":"e_1_2_10_14_1","unstructured":"International Code Council (ICC) 2006. International Building Code Whittier CA."},{"key":"e_1_2_10_15_1","unstructured":"International Code Council (ICC) 2012.Acceptance Criteria for Suspended Ceiling Framing Systems International Code Council Evaluation Service ICC\u2010ES AC368 Whittier CA."},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1193\/1.4000032"},{"key":"e_1_2_10_17_1","unstructured":"National Earthquake Hazards Reduction Program (NEHRP) 2009.Recommended Seismic for New Buildings and Other Structures Washington D.C."},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/eqe.655"},{"key":"e_1_2_10_19_1","unstructured":"PentangeloV.2010 Seismic Assessment of Suspended Ceiling Systems Ph.D. Dissertation University of Naples Federico II."},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1193\/1.2720892"},{"key":"e_1_2_10_21_1","unstructured":"RahmanishamsiE.SoroushianS.andMaragakisM.2014.System\u2010level experiments on ceiling\/piping\/partition systems at UNR\u2010NEES site inTenth U.S. National Conference on Earthquake Engineering Anchorage AK."},{"key":"e_1_2_10_22_1","unstructured":"ReinhornA. M.2000 Design and Development of Testing Frame for Suspended Ceilings internal report and private communication."},{"key":"e_1_2_10_23_1","volume-title":"Experimental Investigation of the Dynamic Behavior of Building Partitions and Suspended Ceilings During Earthquakes, Report No. ARCE R84\u20101","author":"Rihal S.","year":"1984"},{"key":"e_1_2_10_24_1","unstructured":"Risk Management Solutions (RMS) Inc. 2006.2006 Kiholo Bay Hawaii Earthquake RMS Event Report Newark CA."},{"key":"e_1_2_10_25_1","unstructured":"RyanK.SoroushianS.MaragakisM.SatoE.SasakiT.andOkazakiT.2013.Seismic simulation of an integrated ceiling\u2010partition wall\u2010piping system at e\u2010defense Part 1: 3D structural response and base isolation Journal of Structural Engineering(in review)."},{"key":"e_1_2_10_26_1","volume-title":"Modeling and Seismic Evaluation of Nonstructural Components: Testing Frame for Experimental Evaluation of Suspended Ceiling Systems, Technical Rep. MCEER\u201010\u20100004","author":"Reinhorn A. M.","year":"2010"},{"key":"e_1_2_10_27_1","unstructured":"RyuK. P.ReinhornA. M.andFiliatraultA.2012.Full scale dynamic testing of large area suspended in15th World Conference on Earthquake Engineering (15WCEE) 24\u201328 September 2012 Lisbon Portugal."},{"key":"e_1_2_10_28_1","volume-title":"Capacity Evaluation of Suspended Ceiling Systems, Technical Rep. MCEER\u201013\u2010XXXX","author":"Ryu K. P.","year":"2013"},{"key":"e_1_2_10_29_1","unstructured":"RyuK.P.andReinhornA.M.2014.Simplified analytical modeling of a suspended ceiling system inProceedings of the 10thNational Conference in Earthquake Engineering 21\u201325 July 2014 Anchorage AK."},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1193\/083112EQS277M"},{"key":"e_1_2_10_31_1","unstructured":"SoroushianS.MaragakisE. M.ZaghiA. E.RahmanishamsiE.ItaniM.andPekcanG.2014.Response of a 2\u2010story test\u2010bed structure for the seismic evaluation of nonstructural systems Earthquake Engineering and Engineering Vibration(accepted)."},{"key":"e_1_2_10_32_1","doi-asserted-by":"crossref","unstructured":"SoroushianS.RyanK. L.MaragakisE. M.SatoE.SasakiT.OkazakiT.TedescoL.ZaghiA. E.MosquedaG.andAlvarezD.2012.Seismic response of ceiling\/sprinkler piping nonstructural systems in NEES TIPS\/NEES nonstructural\/NIED collaborative tests on a full scale 5\u2010story building inProceeding of 43th Structures Congress ASCE\/SEI 29\u201331March 2012 Chicago IL.","DOI":"10.1061\/9780784412367.118"},{"key":"e_1_2_10_33_1","doi-asserted-by":"crossref","unstructured":"SoroushianS.MaragakisE. M.ItaniM.PekcanG.andZaghiA. E.2011.Design of a test bed structure for shake table simulation of the seismic performance of nonstructural systems inProceeding of 42nd Structures Congress Las Vegas NV.","DOI":"10.1061\/41171(401)106"},{"key":"e_1_2_10_34_1","unstructured":"Staff of the Los Angeles Times 1994.Images of the 1994 Los Angeles Earthquake Los Angeles California Los Angeles Times Los Angeles CA."},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)1076-0431(2000)6:1(6)"}],"container-title":["Earthquake Spectra"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1193\/071514eqs109m","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1193\/071514eqs109m","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1193\/071514eqs109m","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T12:45:31Z","timestamp":1769345131000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1193\/071514eqs109m"},"secondary":[{"URL":"https:\/\/pubs.geoscienceworld.org\/earthquake-spectra\/article\/32\/2\/881\/586975\/experimental-fragility-analysis-of-suspension","label":"geoscienceworld"}]},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,5]]}},"alternative-id":["10.1193\/071514eqs109m"],"URL":"https:\/\/doi.org\/10.1193\/071514eqs109m","archive":["Portico"],"relation":{},"ISSN":["8755-2930","1944-8201"],"issn-type":[{"value":"8755-2930","type":"print"},{"value":"1944-8201","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5]]}}}