{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T17:25:09Z","timestamp":1790443509076,"version":"4.1.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2015,6,24]],"date-time":"2015-06-24T00:00:00Z","timestamp":1435104000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["AAPS PharmSciTech"],"published-print":{"date-parts":[[2015,8]]},"DOI":"10.1208\/s12249-015-0356-3","type":"journal-article","created":{"date-parts":[[2015,6,23]],"date-time":"2015-06-23T16:49:12Z","timestamp":1435078152000},"page":"759-766","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Impact of Vibration and Agitation Speed on Dissolution of USP Prednisone Tablets RS and Various IR Tablet Formulations"],"prefix":"10.1208","volume":"16","author":[{"given":"Nicole","family":"Seeger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sigrid","family":"Lange","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra","family":"Klein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,6,24]]},"reference":[{"issue":"6","key":"356_CR1","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1007\/s11095-008-9822-x","volume":"26","author":"V Gray","year":"2009","unstructured":"Gray V, Kelly G, Xia M, Butler C, Thomas S, Mayock S. The science of USP 1 and 2 dissolution: present challenges and future relevance. Pharm Res. 2009;26(6):1289\u2013302.","journal-title":"Pharm Res"},{"issue":"3","key":"356_CR2","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1007\/s11095-010-0295-3","volume":"28","author":"AJ DeStefano","year":"2011","unstructured":"DeStefano AJ, Hauck WW, Stippler ES, Brown WE, Li C, Huang GG, et al. Establishing new acceptance limits for dissolution performance verification of USPC apparatus 1 and 2 using USPC prednisone tablets reference standard. Pharm Res. 2011;28(3):505\u201316.","journal-title":"Pharm Res"},{"key":"356_CR3","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/S0378-5173(98)00279-8","volume":"175","author":"N Kaniwa","year":"1998","unstructured":"Kaniwa N, Katori N, Aoyagi N, Ishigame N, Kojima S. Collaborative study on the development of a standard for evaluation of vibration levels for dissolution apparatus. Int J Pharm. 1998;175:119\u201329.","journal-title":"Int J Pharm"},{"issue":"1","key":"356_CR4","doi-asserted-by":"crossref","first-page":"28","DOI":"10.14227\/DT120105P28","volume":"12","author":"B Crist","year":"2005","unstructured":"Crist B, Spisak D. Evaluation of induced variance of physical parameters on the calibrated USP dissolution apparatus 1 and 2. Dissolut Technol. 2005;12(1):28\u201331.","journal-title":"Dissolut Technol"},{"issue":"1","key":"356_CR5","doi-asserted-by":"crossref","first-page":"6","DOI":"10.14227\/DT140107P6","volume":"14","author":"S Vangani","year":"2007","unstructured":"Vangani S, Flick T, Tamayo G, Chiu R, Cauchon N. Vibration measurements on dissolution systems and effects on dissolution of prednisone Tablets RS. Dissolut Technol. 2007;14(1):6\u201314.","journal-title":"Dissolut Technol"},{"issue":"1","key":"356_CR6","doi-asserted-by":"crossref","first-page":"29","DOI":"10.14227\/DT150108P29","volume":"15","author":"J Burmicz","year":"2008","unstructured":"Burmicz J. Technical note: why is vibration an issue for dissolution testing? Dissolut Technol. 2008;15(1):29\u201331.","journal-title":"Dissolut Technol"},{"issue":"2","key":"356_CR7","doi-asserted-by":"crossref","first-page":"6","DOI":"10.14227\/DT180211P6","volume":"18","author":"GP Martin","year":"2011","unstructured":"Martin GP, Gray VA. Overview of dissolution instrument qualification. Including common pitfalls. Dissolut Technol. 2011;18(2):6\u201310.","journal-title":"Dissolut Technol"},{"issue":"3","key":"356_CR8","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1002\/jps.2600600343","volume":"60","author":"WF Beyer","year":"1971","unstructured":"Beyer WF, Smith DL. Unexpected variable in the USP-NF rotating dissolution test. J Pharm Sci. 1971;60(3):496\u20137.","journal-title":"J Pharm Sci"},{"issue":"10","key":"356_CR9","doi-asserted-by":"crossref","first-page":"1336","DOI":"10.1002\/jps.2600681043","volume":"68","author":"K Embil","year":"1979","unstructured":"Embil K, Torosian G. Effect of instrumental vibration levels on dissolution. J Pharm Sci. 1979;68(10):1336\u20138.","journal-title":"J Pharm Sci"},{"issue":"8","key":"356_CR10","doi-asserted-by":"crossref","first-page":"3335","DOI":"10.1002\/jps.21242","volume":"97","author":"Z Gao","year":"2008","unstructured":"Gao Z, Moore TW, Doub WH. Vibration effects on dissolution tests with USP apparatuses 1 and 2. J Pharm Sci. 2008;97(8):3335\u201343.","journal-title":"J Pharm Sci"},{"issue":"1","key":"356_CR11","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1002\/jps.21402","volume":"98","author":"Z Gao","year":"2009","unstructured":"Gao Z, Moore TW, Buhse LF, Doub WH. The random vibration effects on dissolution testing with USP apparatus 2. J Pharm Sci. 2009;98(1):297\u2013306.","journal-title":"J Pharm Sci"},{"issue":"1","key":"356_CR12","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1002\/jps.21847","volume":"99","author":"Z Gao","year":"2010","unstructured":"Gao Z, Thies A, Doub W. Vibration effects of lab equipment on dissolution testing with USP paddle method. J Pharm Sci. 2010;99(1):403\u201312.","journal-title":"J Pharm Sci"},{"issue":"3","key":"356_CR13","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1023\/A:1016212804288","volume":"12","author":"GL Amidon","year":"1995","unstructured":"Amidon GL, Lennernas H, Shah VP, Crison JR. A theoretical basis for a biopharmaceutic drug classification: the correlation of in vitro drug product dissolution and in vivo bioavailability. Pharm Res. 1995;12(3):413\u201320.","journal-title":"Pharm Res"},{"issue":"2","key":"356_CR14","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.ejpb.2004.03.001","volume":"58","author":"M Lindenberg","year":"2004","unstructured":"Lindenberg M, Kopp S, Dressman JB. Classification of orally administered drugs on the World Health Organization Model list of Essential Medicines according to the biopharmaceutics classification system. Eur J Pharm Biopharm. 2004;58(2):265\u201378.","journal-title":"Eur J Pharm Biopharm"},{"key":"356_CR15","volume-title":"Guidance for industry: the use of mechanical calibration of dissolution apparatus 1 and 2 \u2013 Current good manufacturing practice (CGMP)","author":"FDA","year":"2010","unstructured":"FDA. Guidance for industry: the use of mechanical calibration of dissolution apparatus 1 and 2 \u2013 Current good manufacturing practice (CGMP). Silver Spring: U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER); 2010."}],"container-title":["AAPS PharmSciTech"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1208\/s12249-015-0356-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1208\/s12249-015-0356-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1208\/s12249-015-0356-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,4]],"date-time":"2019-06-04T03:33:23Z","timestamp":1559619203000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1208\/s12249-015-0356-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6,24]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,8]]}},"alternative-id":["356"],"URL":"https:\/\/doi.org\/10.1208\/s12249-015-0356-3","relation":{},"ISSN":["1530-9932"],"issn-type":[{"value":"1530-9932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,6,24]]}}}