{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T21:00:05Z","timestamp":1790283605257,"version":"4.1.0"},"reference-count":54,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["AAPS PharmSciTech"],"DOI":"10.1208\/s12249-026-03485-5","type":"journal-article","created":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T21:36:46Z","timestamp":1782337006000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Plume Geometry Matters: Investigating the Contribution of Mass-Based Plume Geometry to Aerosol Delivery Efficiency in pMDIs"],"prefix":"10.1208","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5416-4164","authenticated-orcid":false,"given":"Daniel","family":"Moraga-Espinoza","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3261-466X","authenticated-orcid":false,"given":"Eli","family":"Eshaghian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tania F.","family":"Bahamondez-Canas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6582-5869","authenticated-orcid":false,"given":"Hugh D. C.","family":"Smyth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"3485_CR1","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1208\/s12249-022-02278-w","volume":"23","author":"S Baxter","year":"2022","unstructured":"Baxter S, Myatt B, Stein S, Parkinson A, Chambers F, Doub B, et al. Spray pattern and plume geometry testing and methodology: an IPAC-RS working group overview. AAPS PharmSciTech. 2022;23:145\u2013145. https:\/\/doi.org\/10.1208\/s12249-022-02278-w.","journal-title":"AAPS PharmSciTech"},{"issue":"7","key":"3485_CR2","doi-asserted-by":"publisher","first-page":"1051","DOI":"10.3390\/pharmaceutics13071051","volume":"13","author":"J Gallegos-Catal\u00e1n","year":"2021","unstructured":"Gallegos-Catal\u00e1n J, Warnken Z, Bahamondez-Canas TF, Moraga-Espinoza D. Innovating on inhaled bioequivalence: a critical analysis of the current limitations, potential solutions and stakeholders of the process. Pharmaceutics. 2021;13:1051, 1051. https:\/\/doi.org\/10.3390\/pharmaceutics13071051.","journal-title":"Pharmaceutics"},{"key":"3485_CR3","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1002\/psp4.12413","volume":"8","author":"RL Walenga","year":"2019","unstructured":"Walenga RL, Babiskin AH, Zhao L. In silico methods for development of generic drug\u2013device combination orally inhaled drug products. CPT Pharmacometrics Syst Pharmacol. Wiley Online Library. 2019;8:359\u201370. https:\/\/doi.org\/10.1002\/psp4.12413.","journal-title":"Wiley Online Library"},{"key":"3485_CR4","doi-asserted-by":"publisher","first-page":"61","DOI":"10.3390\/ph15010061","volume":"15","author":"M Talaat","year":"2022","unstructured":"Talaat M, Si X, Xi J. Effect of MDI actuation timing on inhalation dosimetry in a human respiratory tract model. Pharmaceuticals (Basel). 2022;15:61.","journal-title":"Pharmaceuticals (Basel)"},{"key":"3485_CR5","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1089\/jamp.2015.1278","volume":"30","author":"R Biswas","year":"2017","unstructured":"Biswas R, Hanania NA, Sabharwal A. Factors determining in vitro lung deposition of albuterol aerosol delivered by ventolin metered-dose inhaler. J Aerosol Med Pulm Drug Deliv SAGE Publications Sage CA: Los Angeles, CA. 2017;30:256\u201366. https:\/\/doi.org\/10.1089\/jamp.2015.1278.","journal-title":"J Aerosol Med Pulm Drug Deliv. SAGE Publications Sage CA: Los Angeles, CA"},{"key":"3485_CR6","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1016\/j.ijpharm.2018.06.016","volume":"547","author":"\u00c1 Farkas","year":"2018","unstructured":"Farkas \u00c1, Horv\u00e1th A, Kerekes A, Nagy A, Kugler S, Tam\u00e1si L, et al. Effect of delayed pMDI actuation on the lung deposition of a fixed-dose combination aerosol drug. Int J Pharm Elsevier. 2018;547:480\u20138. https:\/\/doi.org\/10.1016\/j.ijpharm.2018.06.016.","journal-title":"Int J Pharm. Elsevier"},{"key":"3485_CR7","doi-asserted-by":"publisher","first-page":"1332","DOI":"10.1378\/chest.104.5.1332","volume":"104","author":"KR Chapman","year":"1993","unstructured":"Chapman KR, Love L, Brubaker H. A comparison of breath-actuated and conventional metered-dose inhaler inhalation techniques in elderly subjects. Chest Elsevier. 1993;104:1332\u20137. https:\/\/doi.org\/10.1378\/chest.104.5.1332.","journal-title":"Chest. Elsevier"},{"key":"3485_CR8","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1208\/s12249-025-03147-y","volume":"26","author":"DJ Duke","year":"2025","unstructured":"Duke DJ, Rao L, Myatt B, Cocks P, Stein S, Ong HX, et al. The role of low global warming potential propellants on suspension metered dose inhaler sprays. AAPS PharmSciTech Springer. 2025;26:154. https:\/\/doi.org\/10.1208\/s12249-025-03147-y.","journal-title":"AAPS PharmSciTech. Springer"},{"key":"3485_CR9","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1007\/s11095-025-03830-6","volume":"42","author":"DJ Duke","year":"2025","unstructured":"Duke DJ, Rao L, Myatt B, Cocks P, Stein S, Marasini N, et al. In-vitro evaluation of solution pressurised metered dose inhaler sprays with low-GWP propellants. Pharm Res. 2025;42:385\u2013400. https:\/\/doi.org\/10.1007\/s11095-025-03830-6.","journal-title":"Pharm Res"},{"key":"3485_CR10","unstructured":"FDA. Draft Guidance on Albuterol Sulfate. [Internet]. 2024 [cited 2026 Apr 20]. https:\/\/www.accessdata.fda.gov\/drugsatfda_docs\/psg\/PSG_020503.pdf. Accessed 20 Apr 2026"},{"key":"3485_CR11","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s41030-023-00249-5","volume":"10","author":"H Wachtel","year":"2024","unstructured":"Wachtel H, Emerson-Stadler R, Langguth P, Hohlfeld JM, Ohar J. Aerosol plumes of inhalers used in COPD. Pulm Ther Springer. 2024;10:109\u201322. https:\/\/doi.org\/10.1007\/s41030-023-00249-5.","journal-title":"Pulm Ther. Springer"},{"key":"3485_CR12","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1089\/jamp.2023.0050","volume":"37","author":"Y Zhou","year":"2024","unstructured":"Zhou Y, Yang B, Hong C, Shao Q, Sun N, Mao Y. Correlation Between Dynamic Spray Plume and Drug Deposition of Solution-Based Pressurized Metered-Dose Inhalers. J Aerosol Med Pulm Drug Deliv SAGE Publications Sage CA: Los Angeles, CA. 2024;37:232\u201340. https:\/\/doi.org\/10.1089\/jamp.2023.0050.","journal-title":"J Aerosol Med Pulm Drug Deliv. SAGE Publications Sage CA: Los Angeles, CA"},{"key":"3485_CR13","volume-title":"Effervescent Aerosols: A Novel Formulation Technology for Solution and Suspension-Type Metered Dose Inhalers","author":"MS Kelkar","year":"2016","unstructured":"Kelkar MS. Effervescent Aerosols: A Novel Formulation Technology for Solution and Suspension-Type Metered Dose Inhalers. Baltimore: University of Maryland; 2016."},{"key":"3485_CR14","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1080\/03639040600637598","volume":"32","author":"H Smyth","year":"2006","unstructured":"Smyth H, Hickey AJ, Brace G, Barbour T, Gallion J, Grove J. Spray pattern analysis for metered dose inhalers I: orifice size, particle size, and droplet motion correlations. Drug Dev Ind Pharm. 2006;32:1033\u201341. https:\/\/doi.org\/10.1080\/03639040600637598.","journal-title":"Drug Dev Ind Pharm"},{"key":"3485_CR15","doi-asserted-by":"publisher","first-page":"2963","DOI":"10.1007\/s11095-014-1391-6","volume":"31","author":"NA Buchmann","year":"2014","unstructured":"Buchmann NA, Duke DJ, Shakiba SA, Mitchell DM, Stewart PJ, Traini D, et al. A novel high-speed imaging technique to predict the macroscopic spray characteristics of solution based pressurised metered dose inhalers. Pharm Res. 2014;31:2963\u201374. https:\/\/doi.org\/10.1007\/s11095-014-1391-6.","journal-title":"Pharm Res"},{"key":"3485_CR16","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1007\/s11095-014-1529-6","volume":"32","author":"Y Chen","year":"2015","unstructured":"Chen Y, Young PM, Fletcher DF, Chan HK, Long E, Lewis D, et al. The effect of actuator nozzle designs on the electrostatic charge generated in pressurised metered dose inhaler aerosols. Pharm Res. 2015;32:1237\u201348. https:\/\/doi.org\/10.1007\/s11095-014-1529-6.","journal-title":"Pharm Res"},{"key":"3485_CR17","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1208\/s12248-021-00638-1","volume":"24","author":"SS Bachhav","year":"2021","unstructured":"Bachhav SS, Sheth P, Sandell D, Svensson M, Bhagwat S, Conti DS, et al. Systematic Evaluation of the Effect of Formulation Variables on In Vitro Performance of Mometasone Furoate Suspension-Metered Dose Inhalers: Effect of Formulation Variables on MF-MDI Product Performance. AAPS J Springer. 2021;24:9.","journal-title":"AAPS J. Springer"},{"key":"3485_CR18","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/j.ijpharm.2018.04.008","volume":"543","author":"D Moraga-Espinoza","year":"2018","unstructured":"Moraga-Espinoza D, Eshaghian E, Smyth HDC. Mass Median Plume Angle: A novel approach to characterize plume geometry in solution based pMDIs. Int J Pharm Elsevier. 2018;543:376\u201385. https:\/\/doi.org\/10.1016\/j.ijpharm.2018.04.008.","journal-title":"Int J Pharm. Elsevier"},{"key":"3485_CR19","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1177\/009286150203600309","volume":"36","author":"LM Nagao","year":"2002","unstructured":"Nagao LM. Recommendations to the food and drug administration: metered dose inhaler tests and methods in the chemistry, manufacturing, and controls draft guidances for metered dose inhalers and dry powder inhalers. Drug Inf J. 2002;36:549\u201356. https:\/\/doi.org\/10.1177\/009286150203600309.","journal-title":"Drug Inf J"},{"key":"3485_CR20","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.pecs.2013.06.001","volume":"39","author":"M Linne","year":"2013","unstructured":"Linne M. Imaging in the optically dense regions of a spray: A review of developing techniques. Prog Energy Combust Sci Elsevier. 2013;39:403\u201340. https:\/\/doi.org\/10.1016\/j.pecs.2013.06.001.","journal-title":"Prog Energy Combust Sci. Elsevier"},{"key":"3485_CR21","doi-asserted-by":"publisher","first-page":"17870","DOI":"10.1364\/OE.16.017870","volume":"16","author":"E Berrocal","year":"2008","unstructured":"Berrocal E, Kristensson E, Richter M, Linne M, Ald\u00e9n M. Application of structured illumination for multiple scattering suppression in planar laser imaging of dense sprays. Opt Express. 2008;16:17870\u201381. https:\/\/doi.org\/10.1364\/OE.16.017870.","journal-title":"Opt Express"},{"key":"3485_CR22","unstructured":"Berrocal E. Multiple scattering of light in optical diagnostics of dense sprays and other complex turbid media [Internet]. 2006 [cited 2026 Apr 20]. https:\/\/dspace.lib.cranfield.ac.uk\/items\/943149ba-0e3e-40b2-8c88-bb0f0cdd605b. Accessed 20 Apr 2026"},{"issue":"5","key":"3485_CR23","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1208\/s12248-018-0241-6","volume":"20","author":"DF Moraga-Espinoza","year":"2018","unstructured":"Moraga-Espinoza DF, Eshaghian E, Shaver A, Smyth HDC. Effect of inhalation flow rate on mass-based plume geometry of commercially available suspension pMDIs. AAPS J. 2018;20:84, 84. https:\/\/doi.org\/10.1208\/s12248-018-0241-6.","journal-title":"AAPS J"},{"key":"3485_CR24","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.ijpharm.2018.06.058","volume":"548","author":"D Moraga-Espinoza","year":"2018","unstructured":"Moraga-Espinoza D, Warnken Z, Moore A, Williams RO, Smyth HDC. A modified USP induction port to characterize nasal spray plume geometry and predict turbinate deposition under flow. Int J Pharm. 2018;548:305\u201313. https:\/\/doi.org\/10.1016\/j.ijpharm.2018.06.058.","journal-title":"Int J Pharm"},{"key":"3485_CR25","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1080\/02786820300956","volume":"37","author":"PT O\u2019Shaughnessy","year":"2003","unstructured":"O\u2019Shaughnessy PT, Raabe OG. A comparison of cascade impactor data reduction methods. Aerosol Sci Technol. 2003;37:187\u2013200. https:\/\/doi.org\/10.1080\/02786820300956.","journal-title":"Aerosol Sci Technol"},{"key":"3485_CR26","unstructured":"USP 38\/NF 33. General Chapter<601> Physical Tests and determinations- Inhalation and Nasal drug products: Aerosols, Sprays, and Powders-Performance Quality Tests. The United States Pharmacopeial Convention. 2015. Rockville, MD: USP."},{"key":"3485_CR27","first-page":"273","volume":"18","author":"D Hochrainer","year":"2005","unstructured":"Hochrainer D, H\u00f6lz H, Kreher C, Scaffidi L, Spallek M, Wachtel H. Comparison of the aerosol velocity and spray duration of Respimat\u00ae Soft MistTM inhaler and pressurized metered dose inhalers. SAGE Publications Sage CA: Los Angeles, CA. 2005;18:273\u201382.","journal-title":"SAGE Publications Sage CA: Los Angeles, CA"},{"key":"3485_CR28","unstructured":"Gavtash B, Versteeg HK, Hargrave G, Lewis D, Church T, Brambilla G, et al. CFD simulation of pMDI aerosols in confined geometry of USP\u2010IP using predictive spray source. J Aerosol Med Pulm Drug Deliv. 2015;29."},{"key":"3485_CR29","unstructured":"Oliveira RF, Ferreira AC, Teixeira SF, Teixeira JC, Marques HC. pMDI spray plume analysis: a CFD study. Proceedings of the World Congress on Engineering. 2013;1\u20136"},{"key":"3485_CR30","unstructured":"Dhapare D, Bielski E, Conti DS, Oguntimein O, Sheth P, Svensson M, et al. Effects of Formulation and Actuator Design on Spray Pattern and Plume Geometry of Mometasone Furoate Metered Dose Inhalers (MDIs) [Internet]. 2024 [cited 2026 Apr 20]. https:\/\/www.fda.gov\/science-research\/fda-science-forum\/effects-formulation-and-actuator-design-spray-pattern-and-plume-geometry-mometasone-furoate-metered. Accessed 20 Apr 2026"},{"key":"3485_CR31","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.3390\/pr10071230","volume":"10","author":"F Dastoorian","year":"2022","unstructured":"Dastoorian F, Pakzad L, Kozinski J, Behzadfar E. A CFD investigation on the aerosol drug delivery in the mouth\u2013throat airway using a pressurized metered-dose inhaler device. Processes MDPI. 2022;10:1230. https:\/\/doi.org\/10.3390\/pr10071230.","journal-title":"Processes. MDPI"},{"key":"3485_CR32","doi-asserted-by":"publisher","first-page":"2117","DOI":"10.1007\/s10237-023-01754-x","volume":"22","author":"M Jahed","year":"2023","unstructured":"Jahed M, Kozinski J, Pakzad L. The impact of actuator nozzle and surroundings condition on drug delivery using pressurized-metered dose inhalers. Biomech Model Mechanobiol Springer. 2023;22:2117\u201333. https:\/\/doi.org\/10.1007\/s10237-023-01754-x.","journal-title":"Biomech Model Mechanobiol. Springer"},{"key":"3485_CR33","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/s11095-009-9994-z","volume":"27","author":"T Ehtezazi","year":"2010","unstructured":"Ehtezazi T, Saleem I, Shrubb I, Allanson DR, Jenkinson ID, O\u2019Callaghan C. The interaction between the oropharyngeal geometry and aerosols via pressurised metered dose inhalers. Pharm Res Springer. 2010;27:175\u201386. https:\/\/doi.org\/10.1007\/s11095-009-9994-z.","journal-title":"Pharm Res. Springer"},{"key":"3485_CR34","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1016\/j.ejps.2018.12.008","volume":"128","author":"M Sommerfeld","year":"2019","unstructured":"Sommerfeld M, Cui Y, Schmalfu\u00df S. Potential and constraints for the application of CFD combined with Lagrangian particle tracking to dry powder inhalers. Eur J Pharm Sci Elsevier. 2019;128:299\u2013324. https:\/\/doi.org\/10.1016\/j.ejps.2018.12.008.","journal-title":"Eur J Pharm Sci. Elsevier"},{"key":"3485_CR35","doi-asserted-by":"publisher","first-page":"77","DOI":"10.5405\/jmbe.948","volume":"32","author":"M Zubair","year":"2012","unstructured":"Zubair M, Abdullah MZ, Ismail R, Shuaib IL, Hamid SA, Ahmad KA. A critical overview of limitations of CFD modeling in nasal airflow. J Med Biol Eng \u4e2d\u83ef\u6c11\u570b\u751f\u7269\u91ab\u5b78\u5de5\u7a0b\u5b78\u6703. 2012;32:77\u201384.","journal-title":"J Med Biol Eng \u4e2d\u83ef\u6c11\u570b\u751f\u7269\u91ab\u5b78\u5de5\u7a0b\u5b78\u6703"},{"key":"3485_CR36","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1007\/s11783-011-0365-8","volume":"5","author":"Y Tang","year":"2011","unstructured":"Tang Y, Guo B. Computational fluid dynamics simulation of aerosol transport and deposition. Front Environ Sci Eng China Springer. 2011;5:362\u201377. https:\/\/doi.org\/10.1007\/s11783-011-0365-8.","journal-title":"Front Environ Sci Eng China. Springer"},{"key":"3485_CR37","doi-asserted-by":"publisher","first-page":"1131","DOI":"10.1080\/17425247.2023.2264184","volume":"20","author":"F Buttini","year":"2023","unstructured":"Buttini F, Glieca S, Sonvico F, Lewis DA. Metered dose inhalers in the transition to low GWP propellants: what we know and what is missing to make it happen. Expert Opin Drug Deliv Taylor & Francis. 2023;20:1131\u201343. https:\/\/doi.org\/10.1080\/17425247.2023.2264184.","journal-title":"Expert Opin Drug Deliv. Taylor & Francis"},{"key":"3485_CR38","doi-asserted-by":"publisher","first-page":"2158","DOI":"10.1002\/jps.20116","volume":"93","author":"SW Stein","year":"2004","unstructured":"Stein SW, Myrdal PB. A theoretical and experimental analysis of formulation and device parameters affecting solution MDI size distributions. J Pharm Sci Elsevier. 2004;93:2158\u201375. https:\/\/doi.org\/10.1002\/jps.20116.","journal-title":"J Pharm Sci. Elsevier"},{"key":"3485_CR39","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.ijpharm.2017.06.014","volume":"528","author":"P Sheth","year":"2017","unstructured":"Sheth P, Grimes MR, Stein SW, Myrdal PB. Impact of droplet evaporation rate on resulting in vitro performance parameters of pressurized metered dose inhalers. Int J Pharm Elsevier. 2017;528:360\u201371. https:\/\/doi.org\/10.1016\/j.ijpharm.2017.06.014.","journal-title":"Int J Pharm. Elsevier"},{"key":"3485_CR40","unstructured":"Jeanneret M, Kurowski M, Woodcock J, Jamjeeawon M. Candidate Device Selection for pMDI In-Vitro only Bioequivalence focussing on Spray Pattern and Plume Geometry Analysis. Proceedings of Drug Delivery to the Lungs [Internet]. 2022 [cited 2026 Apr 20]. https:\/\/ddl-conference.com\/wp-content\/uploads\/2022\/11\/20.Jeanneret.pdf. Accessed 20 Apr 2026"},{"key":"3485_CR41","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.ijpharm.2017.04.051","volume":"526","author":"NK Kunda","year":"2017","unstructured":"Kunda NK, Hautmann J, Godoy SE, Marshik P, Chand R, Krishna S, et al. A novel approach to study the pMDI plume using an infrared camera and to evaluate the aerodynamic properties after varying the time between actuations. Int J Pharm Elsevier. 2017;526:41\u20139. https:\/\/doi.org\/10.1016\/j.ijpharm.2017.04.051.","journal-title":"Int J Pharm. Elsevier"},{"key":"3485_CR42","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.ijpharm.2011.10.035","volume":"422","author":"SW Stein","year":"2012","unstructured":"Stein SW, Sheth P, Myrdal PBA. A model for predicting size distributions delivered from pMDIs with suspended drug. Int J Pharm. 2012;422:101\u201315. https:\/\/doi.org\/10.1016\/j.ijpharm.2011.10.035.","journal-title":"Int J Pharm"},{"key":"3485_CR43","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1208\/s12249-016-0564-5","volume":"18","author":"Y Chen","year":"2017","unstructured":"Chen Y, Young PM, Murphy S, Fletcher DF, Long E, Lewis D, et al. High-speed laser image analysis of plume angles for pressurised metered dose inhalers: the effect of nozzle geometry. AAPS PharmSciTech. 2017;18:782\u20139. https:\/\/doi.org\/10.1208\/s12249-016-0564-5.","journal-title":"AAPS PharmSciTech"},{"key":"3485_CR44","unstructured":"White S, Rubiconi F, Sendall J, Baker J, Thawer A, Hamlin F, et al. Investigating rules of design to optimise pMDI plume properties. Proceedings of Drug Delivery to the Lungs [Internet]. 2022 [cited 2026 Apr 20]. https:\/\/ddl-conference.com\/ddl2022\/conference-papers\/investigating-rules-of-design-to-optimise-pmdi-plume-properties\/. Accessed 20 Apr 2026"},{"key":"3485_CR45","doi-asserted-by":"publisher","first-page":"1781","DOI":"10.1016\/j.proeng.2012.07.383","volume":"41","author":"MSFM Rashid","year":"2012","unstructured":"Rashid MSFM, Hamid AHA, Sheng OC, Ghaffar ZA. Effect of inlet slot number on the spray cone angle and discharge coefficient of swirl atomizer. Procedia Eng Elsevier. 2012;41:1781\u20136. https:\/\/doi.org\/10.1016\/j.proeng.2012.07.383.","journal-title":"Procedia Eng. Elsevier"},{"key":"3485_CR46","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/S0016-2361(00)00105-8","volume":"80","author":"SD Sovani","year":"2001","unstructured":"Sovani SD, Chou E, Sojka PE, Gore JP, Eckerle WA, Crofts JD. High pressure effervescent atomization: effect of ambient pressure on spray cone angle. Fuel Elsevier. 2001;80:427\u201335. https:\/\/doi.org\/10.1016\/S0016-2361(00)00105-8.","journal-title":"Fuel. Elsevier"},{"key":"3485_CR47","unstructured":"De Risi A, Di Sante R, Colangelo G. Optical characterization of a Diesel spray at high temperature and pressure. XII Convegno Nazionale AIVELA, Naples [Internet]. 2004 [cited 2026 Apr 20]. https:\/\/iris.unisalento.it\/handle\/11587\/119998. Accessed 20 Apr 2026"},{"key":"3485_CR48","doi-asserted-by":"publisher","first-page":"2639","DOI":"10.1007\/s11095-009-9979-y","volume":"26","author":"S Hoe","year":"2009","unstructured":"Hoe S, Traini D, Chan H-K, Young PM. The influence of flow rate on the aerosol deposition profile and electrostatic charge of single and combination metered dose inhalers. Pharm Res Springer. 2009;26:2639\u201346. https:\/\/doi.org\/10.1007\/s11095-009-9979-y.","journal-title":"Pharm Res Springer"},{"key":"3485_CR49","doi-asserted-by":"publisher","first-page":"647","DOI":"10.4155\/tde-2017-0037","volume":"8","author":"SP Newman","year":"2017","unstructured":"Newman SP. Drug delivery to the lungs: challenges and opportunities. Ther Deliv Taylor & Francis. 2017;8:647\u201361.","journal-title":"Ther Deliv Taylor & Francis"},{"key":"3485_CR50","doi-asserted-by":"publisher","first-page":"1396","DOI":"10.1208\/s12248-017-0095-3","volume":"19","author":"P Sheth","year":"2017","unstructured":"Sheth P, Sandell D, Conti DS, Holt JT, Hickey AJ, Saluja B. Influence of formulation factors on the aerosol performance of suspension and solution metered dose inhalers: a systematic approach. AAPS J. 2017;19:1396\u2013410. https:\/\/doi.org\/10.1208\/s12248-017-0095-3.","journal-title":"AAPS J"},{"key":"3485_CR51","first-page":"179","volume":"2022","author":"L Rao","year":"2022","unstructured":"Rao L, Kusangaya AJ, Marasini N, Ong HX, Myatt B, Cocks P, et al. In-vitro evaluation of pMDI Spray development of HFA134a, HFA152a and HFO1234ze (E). Drug Deliv Lungs Conf. 2022;2022:179\u201382.","journal-title":"Drug Deliv Lungs Conf"},{"key":"3485_CR52","doi-asserted-by":"publisher","first-page":"126876","DOI":"10.1016\/j.ijpharm.2026.126876","volume":"697","author":"DJ Duke","year":"2026","unstructured":"Duke DJ, Wang H, Rao L, McRae E, He P, Ong HX, et al. The effect of mouthpiece shape and size on low-GWP metered dose inhaler performance. Int J Pharm. 2026;697:126876. https:\/\/doi.org\/10.1016\/j.ijpharm.2026.126876.","journal-title":"Int J Pharm"},{"key":"3485_CR53","first-page":"005","volume":"78","author":"N Marasini","year":"2026","unstructured":"Marasini N, Rao R, Duke D, Myatt B, Cocks P, Stein SW, et al. Development and in vitro evaluation of solution-based pressurized metered-dose inhaler formulations using green propellants. J Pharm Pharmacol Oxford Univ Press. 2026;78:005.","journal-title":"J Pharm Pharmacol. Oxford Univ Press"},{"key":"3485_CR54","doi-asserted-by":"publisher","first-page":"126005","DOI":"10.1016\/j.ijpharm.2025.126005","volume":"683","author":"R Rossi","year":"2025","unstructured":"Rossi R, Cottini C, Benassi AA. A computational fluid dynamics model for the simulation of flash-boiling flow inside pressurized metered dose inhalers. Int J Pharm. 2025;683:126005, 126005. https:\/\/doi.org\/10.1016\/j.ijpharm.2025.126005.","journal-title":"Int J Pharm"}],"container-title":["AAPS PharmSciTech"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1208\/s12249-026-03485-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1208\/s12249-026-03485-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1208\/s12249-026-03485-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T20:03:49Z","timestamp":1790280229000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1208\/s12249-026-03485-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,24]]},"references-count":54,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["3485"],"URL":"https:\/\/doi.org\/10.1208\/s12249-026-03485-5","relation":{},"ISSN":["1530-9932"],"issn-type":[{"value":"1530-9932","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,24]]},"assertion":[{"value":"23 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Hugh Smyth owns stock in or consults for Nob Hill Therapeutics, Via Therapeutics, and Cloxero Therapeutics.","order":1,"name":"Ethics","label":"Conflict of Interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"A.I. (Chatgpt) was used for english grammar revision as the corresponding author is not a native speaker.","order":2,"name":"Ethics","label":"A.I. Statement","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"246"}}