{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T17:22:37Z","timestamp":1777051357480,"version":"3.51.4"},"reference-count":8,"publisher":"The Endocrine Society","issue":"10","license":[{"start":{"date-parts":[[2021,7,31]],"date-time":"2021-07-31T00:00:00Z","timestamp":1627689600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,10,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:label\/>\n                  <jats:p>4-Dimensional computed tomography (4DCT) for the detection of (an) enlarged parathyroid(s) is a commonly performed examination in the management of primary hyperparathyroidism. In our center, we introduced a high-frequency multiphase 4DCT protocol obtaining 16 phases, including 11 different arterial phases. Exposure to this multiphase 4DCT technique is similar to that for classic helical 4DCT. In this pictorial essay we reconstructed our multiphase 4DCT series in the manner of a classic helical 4DCT and compare both techniques. We illustrate how multiphase 4DCT may aid in the detection of parathyroid adenomas. We found 17 out of 19 lesions demonstrating a type A pattern of enhancement, therefore suggesting this pattern could be more prevalent than previously thought. Some parathyroid adenomas may be mistaken for enlarged lymph nodes using classic 4DCT whereas high-frequency multiphase 4DCT can detect a temporary rise in enhancement, thus suggesting the lesions in question to be of parathyroid origin. Smaller lesions may prove more obvious as the difference in enhancement between parathyroid and thyroid can become more prominent.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Key Point<\/jats:title>\n                  <jats:p>Using high-frequency multiphase 4DCT an arterial phase with maximum enhancement of parathyroid tissue can be defined. This phase may aid in the detection of parathyroid adenomas.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1210\/jendso\/bvab132","type":"journal-article","created":{"date-parts":[[2021,7,31]],"date-time":"2021-07-31T14:09:38Z","timestamp":1627740578000},"source":"Crossref","is-referenced-by-count":6,"title":["High-frequency Multiphase 4DCT for the Detection of Parathyroid Adenomas: A Pictorial Essay"],"prefix":"10.1210","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0822-1919","authenticated-orcid":false,"given":"Steven","family":"Raeymaeckers","sequence":"first","affiliation":[{"name":"Department of Radiology, Universitair ziekenhuis Brussel, Laarbeeklaan, Jette, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3646-3739","authenticated-orcid":false,"given":"Yannick","family":"De Brucker","sequence":"additional","affiliation":[{"name":"Department of Radiology, Universitair ziekenhuis Brussel, Laarbeeklaan, Jette, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7518-8675","authenticated-orcid":false,"given":"Maurizio","family":"Tosi","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Universitair ziekenhuis Brussel, Laarbeeklaan, Jette, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2830-6899","authenticated-orcid":false,"given":"Nico","family":"Buls","sequence":"additional","affiliation":[{"name":"Department of Radiology, Universitair ziekenhuis Brussel, Laarbeeklaan, Jette, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3601-3212","authenticated-orcid":false,"given":"Johan","family":"De Mey","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Universitair ziekenhuis Brussel, Laarbeeklaan, Jette, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"80","published-online":{"date-parts":[[2021,7,31]]},"reference":[{"issue":"6","key":"2021110515295750600_CIT0001","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.surg.2006.07.028","article-title":"Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography","volume":"140","author":"Rodgers","year":"2006","journal-title":"Surgery."},{"key":"2021110515295750600_CIT0002","first-page":"6614406","article-title":"4DCT scanning technique for primary hyperparathyroidism: a scoping review","volume":"2021","author":"Raeymaeckers","year":"2021","journal-title":"Radiol Res Pract."},{"key":"2021110515295750600_CIT0003","first-page":";S0363-0188(20)30046-3.","article-title":"4D CT parathyroid for the general radiologist: a pictorial essay of illustrative cases","author":"Vijayasarathi","year":"2020","journal-title":"Curr Probl Diagn Radiol."},{"issue":"2","key":"2021110515295750600_CIT0004","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1148\/radiol.2015142393","article-title":"Parathyroid adenomas and hyperplasia on four-dimensional CT scans: three patterns of enhancement relative to the thyroid gland justify a three-phase protocol","volume":"277","author":"Bahl","year":"2015","journal-title":"Radiology."},{"issue":"1","key":"2021110515295750600_CIT0005","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1186\/s12880-021-00597-1","article-title":"Detection of parathyroid adenomas with multiphase 4DCT: towards a true four-dimensional technique","volume":"21","author":"Raeymaeckers","year":"2021","journal-title":"BMC Med Imaging."},{"issue":"11","key":"2021110515295750600_CIT0006","doi-asserted-by":"crossref","first-page":"5718","DOI":"10.1002\/mp.12525","article-title":"Axial or helical? Considerations for wide collimation CT scanners capable of volumetric imaging in both modes","volume":"44","author":"Lambert","year":"2017","journal-title":"Med Phys."},{"issue":"5","key":"2021110515295750600_CIT0007","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1177\/0194599815599372","article-title":"Preoperative 4D CT localization of nonlocalizing parathyroid adenomas by ultrasound and SPECT-CT","volume":"153","author":"Hinson","year":"2015","journal-title":"Otolaryngol Head Neck Surg."},{"issue":"6","key":"2021110515295750600_CIT0008","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1007\/s00268-011-1365-3","article-title":"Parathyroid four-dimensional computed tomography: evaluation of radiation dose exposure during preoperative localization of parathyroid tumors in primary hyperparathyroidism","volume":"36","author":"Mahajan","year":"2012","journal-title":"World J Surg."}],"container-title":["Journal of the Endocrine Society"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/jes\/advance-article-pdf\/doi\/10.1210\/jendso\/bvab132\/39506582\/bvab132.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jes\/article-pdf\/5\/10\/bvab132\/41090730\/bvab132.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jes\/article-pdf\/5\/10\/bvab132\/41090730\/bvab132.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,5]],"date-time":"2021-11-05T15:30:41Z","timestamp":1636126241000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jes\/article\/doi\/10.1210\/jendso\/bvab132\/6332900"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,31]]},"references-count":8,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10,1]]}},"URL":"https:\/\/doi.org\/10.1210\/jendso\/bvab132","relation":{},"ISSN":["2472-1972"],"issn-type":[{"value":"2472-1972","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,10,1]]},"published":{"date-parts":[[2021,7,31]]},"article-number":"bvab132"}}