{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:29:38Z","timestamp":1768436978159,"version":"3.49.0"},"reference-count":23,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2004,6,1]],"date-time":"2004-06-01T00:00:00Z","timestamp":1086048000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2004,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>A micro-capillary rheometer was developed to determine the rheology and injectability of parenteral formulations. The rheometer consisted of a micro-capillary and a glass syringe attached to an Instron that drove the syringe plunger at predetermined speeds and measured resulting forces on the plunger. The cross-head speed and the measured force were used to calculate the shear rate and the shear stress respectively, according to the Hagen-Poiseuille equation. The resulting rheograms of several Newtonian standards showed excellent linearity over a broad range of about 10 times 103 to 160 times 103 s\u22121 and produced accurate and reproducible viscosity determinations over the viscosity range of about 10 times 10\u22123 to 100 times 10\u22123 Pa.s. The developed methodology focussed primarily on the minimization of errors associated with the determination of the wall frictional force using both direct measurement and linear regression to determine this parameter from the data. The effect of micro-capillary diameter, syringe cross-sectional area and micro-capillary length was explored in an effort to increase the measured force so that wall frictional force errors could be minimized. The micro-capillary rheometer gave reproducible and accurate rheograms over a range of shear rates consistent with the shear rate range used in clinical practice, and showed that Newtonian and non-Newtonian rheological behaviours could be evaluated quantitatively.<\/jats:p>","DOI":"10.1211\/0022357023457","type":"journal-article","created":{"date-parts":[[2004,6,28]],"date-time":"2004-06-28T22:02:27Z","timestamp":1088460147000},"page":"709-716","source":"Crossref","is-referenced-by-count":21,"title":["Development and application of a micro-capillary rheometer for in-vitro evaluation of parenteral injectability"],"prefix":"10.1093","volume":"56","author":[{"given":"A","family":"Allahham","sequence":"first","affiliation":[{"name":"Victorian College of Pharmacy, Monash University , Parkville, Melbourne 3052,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D","family":"Mainwaring","sequence":"additional","affiliation":[{"name":"Department of Applied Chemistry, Royal Melbourne Institute of Technology , Melbourne 3000,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P","family":"Stewart","sequence":"additional","affiliation":[{"name":"Victorian College of Pharmacy, Monash University , Parkville, Melbourne 3052,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J","family":"Marriott","sequence":"additional","affiliation":[{"name":"Victorian College of Pharmacy, Monash University , Parkville, Melbourne 3052,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2004,6,1]]},"reference":[{"key":"2024103109404904600_cit1","first-page":"88","article-title":"Formulation design and development of parenteral suspensions","volume":"41","author":"Akers","year":"1987","journal-title":"J. Parenter. Sci. Technol."},{"key":"2024103109404904600_cit2","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1063\/1.1722814","article-title":"Corrections of dynamic and steady flow viscosities","volume":"28","author":"Bagley","year":"1957","journal-title":"J. Appl. Phys."},{"key":"2024103109404904600_cit3","first-page":"11","volume-title":"An Introduction to rheology","author":"Barnes","year":"1989"},{"key":"2024103109404904600_cit4","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1122\/1.549451","article-title":"Separation of elastic and shear thinning effects in the capillary rheometer","volume":"21","author":"Boger","year":"1977","journal-title":"Trans. Soc. Rheol."},{"key":"2024103109404904600_cit5","doi-asserted-by":"crossref","first-page":"2865","DOI":"10.1063\/1.870145","article-title":"Observations of shear-induced particle migration for oscillatory flow of a suspension within a tube","volume":"11","author":"Butler","year":"1999","journal-title":"Phys. Fluids"},{"key":"2024103109404904600_cit6","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1122\/1.550866","article-title":"Flow of RX-08-FK high-energy paste in a capillary rheometer","volume":"41","author":"Carley","year":"1997","journal-title":"J. Rheol."},{"key":"2024103109404904600_cit7","first-page":"63","volume-title":"Rheology of polymeric systems: principles and applications","author":"Carreau","year":"1997"},{"key":"2024103109404904600_cit8","first-page":"24","volume-title":"Polymer melt rheology: a guide for industrial practice","author":"Cogswell","year":"1981"},{"key":"2024103109404904600_cit9","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1146\/annurev.fl.03.010171.001451","article-title":"Suspended particles in fluid flow through tubes","volume":"3","author":"Cox","year":"1971","journal-title":"Annu. Rev. Fluid Mech."},{"key":"2024103109404904600_cit10","first-page":"299","article-title":"Injectable emulsions and suspensions","volume-title":"Pharmaceutical dosage forms \u2014 disperse systems","author":"Floyd","year":"1996","edition":"2nd edn"},{"key":"2024103109404904600_cit11","first-page":"312","article-title":"Rheology","volume-title":"Remington's pharmaceutical sciences","author":"Hans","year":"1990","edition":"18th edn"},{"key":"2024103109404904600_cit12","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1122\/1.551003","article-title":"Piston-driven flow of highly concentrated suspensions","volume":"43","author":"Lukner","year":"1999","journal-title":"J. Rheol."},{"key":"2024103109404904600_cit13","article-title":"Development of a novel formulation of levodopa for the treatment of Parkinson's disease","volume-title":"Ph.D. Thesis","author":"Marriott","year":"1999"},{"key":"2024103109404904600_cit14","first-page":"126","article-title":"Rheology of concentrated suspensions of polymer melts filled with irregularly shaped particles","volume":"25","author":"Mayadunne","year":"1996","journal-title":"Plast. Rubber Compos. Process. Appl."},{"key":"2024103109404904600_cit15","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1016\/S1359-835X(00)00083-X","article-title":"Rheological behavior of short sisal fiber-reinforced polystyrene composites","volume":"31A","author":"Nair","year":"2000","journal-title":"Composites Part A"},{"key":"2024103109404904600_cit16","first-page":"11","volume-title":"Polymer rheology","author":"Nielsen","year":"1977"},{"key":"2024103109404904600_cit17","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/S0196-0644(98)70278-1","article-title":"Pain of local anesthetics: rate of administration and buffering","volume":"31","author":"Scarfone","year":"1998","journal-title":"Ann. Emerg. Med."},{"key":"2024103109404904600_cit18","doi-asserted-by":"crossref","first-page":"5059","DOI":"10.1023\/A:1004423411227","article-title":"Capillary flow behaviour of microcrystalline wax and silicon carbide suspension","volume":"33","author":"Suwardie","year":"1998","journal-title":"J. Mater. Sci."},{"key":"2024103109404904600_cit19","first-page":"468","article-title":"In vitro testing of injectability","volume":"41","author":"Suzuki","year":"1979","journal-title":"Pharm. Ind."},{"key":"2024103109404904600_cit20","doi-asserted-by":"crossref","first-page":"2977","DOI":"10.1111\/j.1151-2916.1993.tb06598.x","article-title":"Rheological behavior of injection-moldable silicon powder-silicon carbide whisker formulations","volume":"76","author":"Tsao","year":"1993","journal-title":"J. Am. Ceram. Soc."},{"key":"2024103109404904600_cit21","first-page":"1100","volume-title":"Impact of the Bagley and Rabinowitsch corrections on capillary rheometer measurements","author":"Watson","year":"1996"},{"key":"2024103109404904600_cit22","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1007\/BF00453463","article-title":"Flow instabilities in capillary flow of concentrated suspensions","volume":"33","author":"Yaras","year":"1994","journal-title":"Rheol. Acta."},{"key":"2024103109404904600_cit23","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1122\/1.550049","article-title":"Slip effects in capillary and parallel disk torsional flows of highly filled suspensions","volume":"33","author":"Yilmazer","year":"1989","journal-title":"J. Rheol."}],"container-title":["Journal of Pharmacy and Pharmacology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1211%2F0022357023457","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/jpp\/article-pdf\/56\/6\/709\/60260771\/0022357023457.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jpp\/article-pdf\/56\/6\/709\/60260771\/0022357023457.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,31]],"date-time":"2024-10-31T10:18:11Z","timestamp":1730369891000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jpp\/article\/56\/6\/709\/6147261"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,6,1]]},"references-count":23,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2004,6,1]]},"published-print":{"date-parts":[[2004,6,1]]}},"URL":"https:\/\/doi.org\/10.1211\/0022357023457","relation":{},"ISSN":["0022-3573","2042-7158"],"issn-type":[{"value":"0022-3573","type":"print"},{"value":"2042-7158","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2004,6]]},"published":{"date-parts":[[2004,6,1]]}}}