{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T16:57:57Z","timestamp":1790787477646,"version":"4.1.0"},"reference-count":49,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2016,4]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Diagnostic and interventional procedures are often facilitated by moderate procedure-related sedation. Many studies support the overall safety of this sedation; however, adverse cardiovascular and respiratory events are reported in up to 70% of these procedures, more frequently in very young, very old, or sicker patients. Monitoring with pulse oximetry may underreport hypoventilation during sedation, particularly if supplemental oxygen is provided. Capnometry may result in false alarms during sedation when patients mouth breathe or displace sampling devices. Advanced monitor use during sedation may allow event detection before complications develop. This 2-part pilot study used advanced monitors during planned moderate sedation to (1) determine incidences of desaturation, low respiratory rate, and deeper than intended sedation alarm events; and (2) determine whether advanced monitor use is associated with fewer alarm events.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      Adult patients undergoing scheduled gastroenterology or interventional radiology procedures with planned moderate sedation given by dedicated sedation nurses under the direction of procedural physicians (procedural sedation team) were monitored per standard protocols (electrocardiography blood pressure, pulse oximetry, and capnometry) and advanced monitors (acoustic respiratory monitoring and processed electroencephalograpy). Data were collected to computers for analysis. Advanced monitor parameters were not visible to teams in part 1 (standard) but were visible to teams in part 2 (advanced). Alarm events were defined as desaturation\u2014SpO\n                      <jats:sub>2<\/jats:sub>\n                      \u226492%; respiratory depression, acoustic respiratory rate \u22648 breaths per minute, and deeper than intended sedation, indicated by processed electroencephalograpy. The number of alarm events was compared.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Of 100 patients enrolled, 10 were excluded for data collection computer malfunction or consent withdrawal. Data were analyzed from 90 patients (44 standard and 46 advanced). Advanced had fewer total alarms than standard (Wilcoxon-Mann-Whitney = 2.073,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.038; Wilcoxon-Mann-Whitney odds, 1.67; 95% confidence interval [CI], 1.04\u20132.88). Similar numbers of standard and advanced had \u22651 alarm event (Wald difference, \u221210.2%; 95% CI, \u221226.4% to 7.0%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.237). Fewer advanced patients had \u22651 respiratory depression event (Wald difference, \u221222.1%; 95% CI, \u221240.9% to \u22122.4%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.036) or \u22651 desaturation event (Wald difference, \u221224.2%; 95% CI, \u221242.8% to \u22123.6%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.021); but there was no significant difference in deeper than intended sedation events (Wald difference, \u22121.38%; 95% CI, \u221220.21% to 17.49%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.887).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Use of advanced monitoring parameters during planned moderate sedation was associated with fewer alarm events, patients experiencing desaturation, and patients experiencing respiratory depression alarm events. This pilot study suggests that further study into the safety and outcome impacts of advanced monitoring during procedure-related sedation is warranted.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000001160","type":"journal-article","created":{"date-parts":[[2016,2,2]],"date-time":"2016-02-02T08:52:41Z","timestamp":1454403161000},"page":"1070-1078","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":17,"title":["Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation"],"prefix":"10.1213","volume":"122","author":[{"given":"Richard L.","family":"Applegate","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Lenart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathew","family":"Malkin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minhthy N.","family":"Meineke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvana","family":"Qoshlli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica","family":"Neumann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Paul","family":"Jacobson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison","family":"Kruger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey","family":"Ching","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Hassanian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Um","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-18-20250810","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.giec.2014.09.009","article-title":"Sedation-related complications in gastrointestinal endoscopy.","volume":"25","author":"Vargo","year":"2015","journal-title":"Gastrointest Endosc Clin N Am"},{"key":"R2-18-20250810","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1055\/s-0032-1330441","article-title":"Sedation-associated complications in endoscopyprospective multicentre survey of 191142 patients.","volume":"51","author":"Frieling","year":"2013","journal-title":"Z Gastroenterol"},{"key":"R3-18-20250810","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.gie.2006.12.040","article-title":"A national study of cardiopulmonary unplanned events after GI endoscopy.","volume":"66","author":"Sharma","year":"2007","journal-title":"Gastrointest Endosc"},{"key":"R4-18-20250810","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1007\/s10620-008-0452-2","article-title":"Risk factors for hypoxemia during ambulatory gastrointestinal endoscopy in ASA I-II patients.","volume":"54","author":"Qadeer","year":"2009","journal-title":"Dig Dis Sci"},{"key":"R5-18-20250810","doi-asserted-by":"crossref","first-page":"463","DOI":"10.3748\/wjg.v19.i4.463","article-title":"Sedation in gastrointestinal endoscopy: current issues.","volume":"19","author":"Triantafillidis","year":"2013","journal-title":"World J Gastroenterol"},{"key":"R6-18-20250810","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1016\/j.gie.2007.12.046","article-title":"A systematic review and meta-analysis of randomized, controlled trials of moderate sedation for routine endoscopic procedures.","volume":"67","author":"McQuaid","year":"2008","journal-title":"Gastrointest Endosc"},{"key":"R7-18-20250810","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1197\/j.aem.2004.12.009","article-title":"Adverse events associated with procedural sedation and analgesia in a pediatric emergency department: a comparison of common parenteral drugs.","volume":"12","author":"Roback","year":"2005","journal-title":"Acad Emerg Med"},{"key":"R9-18-20250810","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.gie.2006.03.015","article-title":"Complications of pediatric EGD: a 4-year experience in PEDS-CORI.","volume":"65","author":"Thakkar","year":"2007","journal-title":"Gastrointest Endosc"},{"key":"R10-18-20250810","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1038\/ajg.2012.246","article-title":"Endoscopy in the elderly.","volume":"107","author":"Travis","year":"2012","journal-title":"Am J Gastroenterol"},{"key":"R11-18-20250810","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/MCG.0b013e3181c64d64","article-title":"Endoscopy in the elderly: a review of the efficacy and safety of colonoscopy, esophagogastroduodenoscopy, and endoscopic retrograde cholangiopancreatography.","volume":"44","author":"Jafri","year":"2010","journal-title":"J Clin Gastroenterol"},{"key":"R12-18-20250810","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.gie.2011.06.023","article-title":"Adverse events in older patients undergoing colonoscopy: a systematic review and meta-analysis.","volume":"74","author":"Day","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"R14-18-20250810","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1097\/ACO.0b013e32833b7d7c","article-title":"Risks of anesthesia or sedation outside the operating room: the role of the anesthesia care provider.","volume":"23","author":"Metzner","year":"2010","journal-title":"Curr Opin Anaesthesiol"},{"key":"R15-18-20250810","doi-asserted-by":"crossref","first-page":"527","DOI":"10.4253\/wjge.v5.i11.527","article-title":"Sedation-related complications in gastrointestinal endoscopy.","volume":"5","author":"Amornyotin","year":"2013","journal-title":"World J Gastrointest Endosc"},{"key":"R16-18-20250810","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1097\/ACO.0b013e32832dba50","article-title":"The risk and safety of anesthesia at remote locations: the US closed claims analysis.","volume":"22","author":"Metzner","year":"2009","journal-title":"Curr Opin Anaesthesiol"},{"key":"R18-18-20250810","doi-asserted-by":"crossref","first-page":"1552","DOI":"10.1378\/chest.126.5.1552","article-title":"Supplemental oxygen impairs detection of hypoventilation by pulse oximetry.","volume":"126","author":"Fu","year":"2004","journal-title":"Chest"},{"key":"R19-18-20250810","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1213\/01.ANE.0000131964.67524.E7","article-title":"Capnography accurately detects apnea during monitored anesthesia care.","volume":"99","author":"Soto","year":"2004","journal-title":"Anesth Analg"},{"key":"R20-18-20250810","doi-asserted-by":"crossref","first-page":"82","DOI":"10.4253\/wjge.v6.i3.82","article-title":"Feasibility of breath monitoring in patients undergoing elective colonoscopy under propofol sedation: a single-center pilot study.","volume":"6","author":"Anand","year":"2014","journal-title":"World J Gastrointest Endosc"},{"key":"R21-18-20250810","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.jclinane.2010.08.012","article-title":"Capnography enhances surveillance of respiratory events during procedural sedation: a meta-analysis.","volume":"23","author":"Waugh","year":"2011","journal-title":"J Clin Anesth"},{"key":"R22-18-20250810","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1038\/ajg.2012.136","article-title":"Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study).","volume":"107","author":"Beitz","year":"2012","journal-title":"Am J Gastroenterol"},{"key":"R23-18-20250810","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1007\/s12630-014-0232-8","article-title":"Guidelines to the practice of anesthesiaRevised Edition 2015.","volume":"62","author":"Merchant","year":"2015","journal-title":"Can J Anaesth"},{"key":"R26-18-20250810","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1111\/anae.12289","article-title":"Intra-operative monitoringmany alarms with minor impact.","volume":"68","author":"de Man","year":"2013","journal-title":"Anaesthesia"},{"key":"R27-18-20250810","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1213\/ANE.0b013e3181fcc504","article-title":"The wolf is crying in the operating room: patient monitor and anesthesia workstation alarming patterns during cardiac surgery.","volume":"112","author":"Schmid","year":"2011","journal-title":"Anesth Analg"},{"key":"R28-18-20250810","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1001\/jama.2014.710","article-title":"Redesigning hospital alarms for patient safety: alarmed and potentially dangerous.","volume":"311","author":"Chopra","year":"2014","journal-title":"JAMA"},{"key":"R29-18-20250810","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.jelectrocard.2012.08.050","article-title":"Clinical alarm hazards: a top ten health technology safety concern.","volume":"45","author":"Keller","year":"2012","journal-title":"J Electrocardiol"},{"key":"R31-18-20250810","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1111\/pan.12254","article-title":"Accuracy of acoustic respiration rate monitoring in pediatric patients.","volume":"23","author":"Patino","year":"2013","journal-title":"Paediatr Anaesth"},{"key":"R32-18-20250810","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/BF02078136","article-title":"End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error.","volume":"12","author":"Friesen","year":"1996","journal-title":"J Clin Monit"},{"key":"R33-18-20250810","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1097\/ALN.0b013e3181b060b6","article-title":"Accuracy of postoperative end-tidal PCO2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea.","volume":"111","author":"Kasuya","year":"2009","journal-title":"Anesthesiology"},{"key":"R34-18-20250810","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1097\/LBR.0000000000000087","article-title":"Capnography monitoring in procedural sedation for bronchoscopy.","volume":"21","author":"Abdelmalak","year":"2014","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R35-18-20250810","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1097\/ANA.0b013e31827c9d5a","article-title":"Accuracy of end-tidal CO2 measurement through the nose and pharynx in nonintubated patients during digital subtraction cerebral angiography.","volume":"25","author":"Zhang","year":"2013","journal-title":"J Neurosurg Anesthesiol"},{"key":"R36-18-20250810","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/ALN.0b013e318278c8b6","article-title":"Capnography outside the operating rooms.","volume":"118","author":"Kodali","year":"2013","journal-title":"Anesthesiology"},{"key":"R37-18-20250810","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/ACO.0b013e32833b9c9f","article-title":"Standardizing care and monitoring for anesthesia or procedural sedation delivered outside the operating room.","volume":"23","author":"Eichhorn","year":"2010","journal-title":"Curr Opin Anaesthesiol"},{"key":"R38-18-20250810","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1213\/ANE.0b013e318290c798","article-title":"The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry.","volume":"117","author":"Ramsay","year":"2013","journal-title":"Anesth Analg"},{"key":"R39-18-20250810","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1093\/bja\/aer510","article-title":"Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia.","volume":"108","author":"Mimoz","year":"2012","journal-title":"Br J Anaesth"},{"key":"R40-18-20250810","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1111\/anae.12799","article-title":"Comparison of acoustic and impedance methods with mask capnometry to assess respiration rate in obese patients recovering from general anaesthesia.","volume":"70","author":"Frasca","year":"2015","journal-title":"Anaesthesia"},{"key":"R41-18-20250810","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.bpa.2005.07.008","article-title":"Patient state index.","volume":"20","author":"Drover","year":"2006","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"R44-18-20250810","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1136\/bmj.2.5920.656","article-title":"Controlled sedation with alphaxalone-alphadolone.","volume":"2","author":"Ramsay","year":"1974","journal-title":"Br Med J"},{"key":"R45-18-20250810","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1164\/rccm.2107138","article-title":"The Richmond Agitation-Sedation Scale: validity and reliability in adult intensive care unit patients.","volume":"166","author":"Sessler","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"R46-18-20250810","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1345\/aph.1H421","article-title":"Opioid conversions in acute care.","volume":"41","author":"Patanwala","year":"2007","journal-title":"Ann Pharmacother"},{"key":"R47-18-20250810","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/S0885-3924(01)00294-9","article-title":"Equianalgesic dose ratios for opioids. a critical review and proposals for long-term dosing.","volume":"22","author":"Pereira","year":"2001","journal-title":"J Pain Symptom Manage"},{"key":"R48-18-20250810","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1213\/ANE.0000000000000537","article-title":"The effectiveness of oxygen delivery and reliability of carbon dioxide waveforms: a crossover comparison of 4 nasal cannulae.","volume":"120","author":"Ebert","year":"2015","journal-title":"Anesth Analg"},{"key":"R49-18-20250810","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1213\/ANE.0b013e31827f53d7","article-title":"Statistical grand rounds: a review of analysis and sample size calculation considerations for Wilcoxon tests.","volume":"117","author":"Divine","year":"2013","journal-title":"Anesth Analg"},{"key":"R50-18-20250810","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1213\/ANE.0b013e31829ed28f","article-title":"Wilcoxon-Mann-Whitney test used for data that are not normally distributed.","volume":"117","author":"Dexter","year":"2013","journal-title":"Anesth Analg"},{"key":"R51-18-20250810","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1159\/000321621","article-title":"Hypoxemia during moderate sedation for gastrointestinal endoscopy: causes and associations.","volume":"84","author":"Qadeer","year":"2011","journal-title":"Digestion"},{"key":"R52-18-20250810","first-page":"12","article-title":"Sedation levels during propofol administration for outpatient colonoscopies.","volume":"27","author":"Ramsay","year":"2014","journal-title":"Proc (Bayl Univ Med Cent)"},{"key":"R53-18-20250810","doi-asserted-by":"crossref","first-page":"2689","DOI":"10.1111\/j.1572-0241.2005.00320.x","article-title":"Deep sedation occurs frequently during elective endoscopy with meperidine and midazolam.","volume":"100","author":"Patel","year":"2005","journal-title":"Am J Gastroenterol"},{"key":"R54-18-20250810","first-page":"200","article-title":"Evaluation of the SEDline to improve the safety and efficiency of conscious sedation.","volume":"24","author":"Caputo","year":"2011","journal-title":"Proc (Bayl Univ Med Cent)"},{"key":"R55-18-20250810","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1213\/ANE.0000000000000362","article-title":"Performance of Masimo rainbow acoustic monitoring for tracking changing respiratory rates under laryngeal mask airway general anesthesia for surgical procedures in the operating room: a prospective observational study.","volume":"119","author":"Atkins","year":"2014","journal-title":"Anesth Analg"},{"key":"R56-18-20250810","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1093\/bja\/aeu219","article-title":"Evaluation of acoustic respiration rate monitoring after extubation in intensive care unit patients.","volume":"113","author":"Autet","year":"2014","journal-title":"Br J Anaesth"},{"key":"R57-18-20250810","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1007\/s10877-014-9556-8","article-title":"Detection of respiratory compromise by acoustic monitoring, capnography, and brain function monitoring during monitored anesthesia care.","volume":"28","author":"Tanaka","year":"2014","journal-title":"J Clin Monit Comput"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201604000-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:27:21Z","timestamp":1786112841000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201604000-00018"}},"subtitle":["A 2-Part Pilot Trial"],"short-title":[],"issued":{"date-parts":[[2016,4]]},"references-count":49,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000001160","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2016,4]]}}}