{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T00:09:03Z","timestamp":1793578143676,"version":"4.5.0"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>\n                      Endotracheal tube security is a critical safety issue. We compared the mobility of an in situ endotracheal tube secured with adhesive tape to the one secured with a new commercially available purpose-designed endotracheal tube-holder device (Haider Tube-Guard\n                      <jats:sup>\u00ae<\/jats:sup>\n                      ). We also observed for the incidence of oropharyngeal or facial trauma associated with the 2 tube fixation methods.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Thirty adult patients undergoing general anesthesia with neuromuscular blockade were prospectively enrolled. Immediately after intubation, a single study author positioned the endotracheal tube tip in the distal trachea using a bronchoscope. Anesthesiologists caring for patients secured the tube in their normal fashion (always with adhesive tape). A force transducer was used to apply linear force, increasing to 15 N or until the principal investigator deemed that the force be aborted for safety reasons. The displacement of the endotracheal tube was measured with the bronchoscope. Any tape was then removed and the endotracheal tube secured with the Haider Tube-Guard device. The linear force was reapplied and the displacement of the endotracheal tube measured. The Haider Tube-Guard device was left in place for the duration of the case. The patient\u2019s face and oropharynx were examined for any evidence of trauma during surgery and in the recovery room. On discharge from the postanesthesia care unit, the patient answered a brief survey assessing for any subjective evidence of minor facial or oropharyngeal trauma.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Under standardized tension, the endotracheal tube withdrew a mean distance of 3.4 cm when secured with adhesive tape versus 0.3 cm when secured with the Haider Tube-Guard (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). Ninety-seven percent of patients (29\/30) experienced clinically significant endotracheal tube movement (&gt;1 cm) when adhesive tape was used to secure the tube versus 3% (1\/30) when the Haider Tube-Guard was used (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). Thirty percent of patients (9\/30) were potentially deemed a high extubation risk (endotracheal tube movement &gt;4 cm) when the endotracheal tube was secured with tape versus 0% (0\/30) when secured with the Haider Tube-Guard (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.004). Six patients with taped endotracheal tubes required the traction to be aborted before 15 N of force was achieved to prevent potential extubation as the tape either separated from the face or stretched to allow excessive endotracheal tube movement. None of the patients appeared to sustain any injury from the Haider Tube-Guard device.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>The Haider Tube-Guard significantly reduced the mobility of the endotracheal tube when compared with adhesive tape and was well tolerated in our observations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000001222","type":"journal-article","created":{"date-parts":[[2016,3,22]],"date-time":"2016-03-22T05:06:05Z","timestamp":1458623165000},"page":"1439-1443","source":"Crossref","is-referenced-by-count":36,"title":["A Comparison of the Haider Tube-Guard\u00ae Endotracheal Tube Holder Versus Adhesive Tape to Determine if This Novel Device Can Reduce Endotracheal Tube Movement and Prevent Unplanned Extubation"],"prefix":"10.1213","volume":"122","author":[{"given":"Jack C.","family":"Buckley","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam P.","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John S.","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirsten M.","family":"Rogers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nir N.","family":"Hoftman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"Suppl I","key":"R1-20230816","first-page":"11125","article-title":"Part 4: Advanced life support.","volume":"112","year":"2005","journal-title":"Circulation"},{"key":"R2-20230816","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.annemergmed.2007.05.013","article-title":"Extubation force: tape versus endotracheal tube holders.","volume":"50","author":"Carlson","year":"2007","journal-title":"Ann Emerg Med"},{"key":"R3-20230816","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1016\/j.resuscitation.2009.08.007","article-title":"Extubation force: a comparison of adhesive tape, non-adhesive tape and a commercial endotracheal tube holder.","volume":"80","author":"Owen","year":"2009","journal-title":"Resuscitation"},{"key":"R4-20230816","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.4187\/respcare.00954","article-title":"Endotracheal tube extubation force: adhesive tape versus endotracheal tube holder.","volume":"56","author":"Shimizu","year":"2011","journal-title":"Respir Care"},{"key":"R5-20230816","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1177\/0310057X0703500512","article-title":"A comparison of tape-tying versus a tube-holding device for securing endotracheal tubes in adults.","volume":"35","author":"Murdoch","year":"2007","journal-title":"Anaesth Intensive Care"},{"key":"R6-20230816","first-page":"140","article-title":"Evaluation of two methods used to stabilize oral endotracheal tubes.","volume":"16","author":"Tasota","year":"1987","journal-title":"Heart Lung"},{"key":"R7-20230816","first-page":"59","article-title":"A comparison of four endotracheal tube holders.","volume":"23","author":"Kaplow","year":"1994","journal-title":"Heart Lung"},{"key":"R8-20230816","doi-asserted-by":"crossref","first-page":"158, 160","DOI":"10.1016\/S1036-7314(05)80029-3","article-title":"Best practice in stabilisation of oral endotracheal tubes: a systematic review.","volume":"18","author":"Gardner","year":"2005","journal-title":"Aust Crit Care"},{"key":"R10-20230816","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1213\/00000539-199610000-00036","article-title":"Cricoid pressure: teaching the recommended level.","volume":"83","author":"Herman","year":"1996","journal-title":"Anesth Analg"},{"key":"R11-20230816","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1016\/j.hrtlng.2006.10.002","article-title":"Unplanned extubation in orally intubated medical patients in the intensive care unit: a prospective cohort study.","volume":"36","author":"Bouza","year":"2007","journal-title":"Heart Lung"},{"key":"R12-20230816","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1164\/ajrccm.157.4.9702083","article-title":"Unplanned extubations in the adult intensive care unit: a prospective multicenter study. Association des R\u00e9animateurs du Centre-Ouest.","volume":"157","author":"Boulain","year":"1998","journal-title":"Am J Respir Crit Care Med"},{"key":"R13-20230816","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/00003246-200001000-00010","article-title":"Accidental removal of endotracheal and nasogastric tubes and intravascular catheters.","volume":"28","author":"Carri\u00f3n","year":"2000","journal-title":"Crit Care Med"},{"key":"R14-20230816","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1111\/j.1460-9592.2012.03920.x","article-title":"Incidence and causes of perioperative endotracheal reintubation in children: a review of 28 208 anesthetics.","volume":"23","author":"Chui","year":"2013","journal-title":"Paediatr Anaesth"},{"key":"R15-20230816","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1378\/chest.112.5.1317","article-title":"Characteristics and outcomes of patients who self-extubate from ventilatory support: a case-control study.","volume":"112","author":"Atkins","year":"1997","journal-title":"Chest"},{"key":"R16-20230816","first-page":"1171","article-title":"Unplanned tracheal extubation outside the operating room: a quality improvement audit of hemodynamic and tracheal airway complications associated with emergency tracheal reintubation.","volume":"86","author":"Mort","year":"1998","journal-title":"Anesth Analg"},{"key":"R17-20230816","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1164\/ajrccm.161.6.9908068","article-title":"Effect of unplanned extubation on outcome of mechanical ventilation.","volume":"161","author":"Epstein","year":"2000","journal-title":"Am J Respir Crit Care Med"},{"key":"R18-20230816","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1097\/00000542-200612000-00007","article-title":"Trends in anesthesia-related death and brain damage: a closed claims analysis.","volume":"105","author":"Cheney","year":"2006","journal-title":"Anesthesiology"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201605000-00031","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:32:17Z","timestamp":1786113137000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201605000-00031"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":17,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000001222","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]}}}