{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:21:26Z","timestamp":1786123286810,"version":"build-2736575974"},"reference-count":82,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:p>\n                    Pulse oximetry is an undisputable standard of care in clinical monitoring. It combines a spectrometer to detect hypoxemia with a plethysmograph for the diagnosis, monitoring, and follow-up of cardiovascular diseases. These pulse oximetry capabilities are extremely useful for assessing the respiratory and circulatory status and for monitoring of mechanically ventilated patients. On the one hand, the key spectrography-derived function of pulse oximetry is to evaluate a patient\u2019s gas exchange that results from a particular ventilatory treatment by continuously and noninvasively measuring arterial hemoglobin saturation (Sp\n                    <jats:sc>o<\/jats:sc>\n                    <jats:sub>2<\/jats:sub>\n                    ). This information helps to maintain patients above the hypoxemic levels, leading to appropriate ventilator settings and inspired oxygen fractions. However, whenever higher than normal oxygen fractions are used, Sp\n                    <jats:sc>o<\/jats:sc>\n                    <jats:sub>2<\/jats:sub>\n                    can mask existing oxygenation defects in ventilated patients. This limitation, resulting from the S shape of the oxyhemoglobin saturation curve, can be overcome by reducing the oxygen fraction delivered to the patient in a controlled and stepwise manner. This results in a Sp\n                    <jats:sc>o<\/jats:sc>\n                    <jats:sub>2<\/jats:sub>\n                    \/F\n                    <jats:sc>io<\/jats:sc>\n                    <jats:sub>2<\/jats:sub>\n                    diagram, which allows a rough characterization of a patient\u2019s gas exchange, shunt, and the amount of lung area with a low ventilation\/perfusion ratio without the need of blood sampling. On the other hand, the photoplethysmography-derived oximeter function has barely been exploited for the purpose of monitoring hemodynamics in mechanically ventilated patients. The analysis of the photoplethysmography contour provides useful real-time and noninvasive information about the interaction of heart and lungs during positive pressure ventilation. These hemodynamic monitoring capabilities are related to both the assessment of preload dependency\u2014mainly by analyzing the breath-by-breath variation of the photoplethysmographic signals\u2014and the analysis of arterial impedance, which examines the changes in the plethysmographic amplitude, contour, and derived indexes. In this article, we present and describe these extended monitoring capabilities and propose a more holistic monitoring concept that takes advantage of these advanced uses of pulse oximetry in the monitoring of ventilated patients. Today\u2019s monitors need to be improved if such novel functionalities were to be offered for clinical use. Future developments and clinical evaluations are needed to establish the true potential of these advanced monitoring uses of pulse oximetry.\n                  <\/jats:p>","DOI":"10.1213\/ane.0000000000001283","type":"journal-article","created":{"date-parts":[[2016,5,14]],"date-time":"2016-05-14T10:58:43Z","timestamp":1463223523000},"page":"62-71","source":"Crossref","is-referenced-by-count":59,"title":["Advanced Uses of Pulse Oximetry for Monitoring Mechanically Ventilated Patients"],"prefix":"10.1213","volume":"124","author":[{"given":"Gerardo","family":"Tusman","sequence":"first","affiliation":[{"name":"Department of Critical Care Medicine, CIBERES, CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan H.","family":"Bohm","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, CIBERES, CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando","family":"Suarez-Sipmann","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, CIBERES, CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230812","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/BF02442476","article-title":"Spectrophotometric monitoring of arterial oxygen saturation in the fingertip.","volume":"18","author":"Yoshiya","year":"1980","journal-title":"Med Biol Eng Comput"},{"key":"R2-20230812","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","article-title":"Photoplethysmography and its application in clinical physiological measurement.","volume":"28","author":"Allen","year":"2007","journal-title":"Physiol Meas"},{"key":"R3-20230812","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1213\/00000539-198903000-00035","article-title":"Principles of pulse oximetry: theoretical and practical considerations.","volume":"68","author":"Alexander","year":"1989","journal-title":"Anesth Analg"},{"key":"R4-20230812","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1378\/chest.98.5.1244","article-title":"Pulse oximetry. Uses and abuses.","volume":"98","author":"Schnapp","year":"1990","journal-title":"Chest"},{"key":"R5-20230812","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1093\/clinchem\/38.9.1601","article-title":"Pulse oximetry: theory and applications for noninvasive monitoring.","volume":"38","author":"Mendelson","year":"1992","journal-title":"Clin Chem"},{"key":"R6-20230812","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/27\/1\/R01","article-title":"Pulse oximetry in the oesophagus.","volume":"27","author":"Kyriacou","year":"2006","journal-title":"Physiol Meas"},{"key":"R7-20230812","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1213\/01.ane.0000269514.31660.09","article-title":"Takuo Aoyagi: discovery of pulse oximetry.","volume":"105","author":"Severinghaus","year":"2007","journal-title":"Anesth Analg"},{"key":"R8-20230812","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1097\/00000542-198310000-00015","article-title":"Evaluation of pulse oximetry.","volume":"59","author":"Yelderman","year":"1983","journal-title":"Anesthesiology"},{"key":"R9-20230812","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00000542-198501000-00020","article-title":"Noninvasive detection of profound arterial desaturations using a pulse oximetry device.","volume":"62","author":"Mihm","year":"1985","journal-title":"Anesthesiology"},{"key":"R10-20230812","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1378\/chest.83.6.860","article-title":"The accuracy and response characteristics of a simplified ear oximeter.","volume":"83","author":"Rebuck","year":"1983","journal-title":"Chest"},{"key":"R11-20230812","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1093\/bja\/68.2.146","article-title":"Hypoxaemia is reduced by pulse oximetry monitoring in the operating theatre and in the recovery room.","volume":"68","author":"Moller","year":"1992","journal-title":"Br J Anaesth"},{"key":"R12-20230812","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1097\/00000542-199106000-00039","article-title":"Postanesthetic hypoxemia and oxygen administration.","volume":"74","author":"Canet","year":"1991","journal-title":"Anesthesiology"},{"key":"R13-20230812","first-page":"CD002013","article-title":"Pulse oximetry for perioperative monitoring.","volume":"4","author":"Pedersen","year":"2009","journal-title":"Cochrane Database Syst Rev"},{"key":"R14-20230812","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1001\/jama.1986.03380080063029","article-title":"Standards for patient monitoring during anesthesia at Harvard Medical School.","volume":"256","author":"Eichhorn","year":"1986","journal-title":"JAMA"},{"key":"R15-20230812","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1097\/ALN.0b013e31816c89e1","article-title":"Utility of the photoplethysmogram in circulatory monitoring.","volume":"108","author":"Reisner","year":"2008","journal-title":"Anesthesiology"},{"key":"R16-20230812","first-page":"542","article-title":"Techniques used to evaluate the cutaneous microcirculation: application of photoplethysmography to the assessment of a phlebotropic agent in the treatment of leg ulcers.","volume":"45","author":"Guillot","year":"1994","journal-title":"Angiology"},{"key":"R17-20230812","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1111\/j.1524-4725.1995.tb00113.x","article-title":"Photoplethysmography in the diagnosis of venous disease.","volume":"21","author":"Fronek","year":"1995","journal-title":"Dermatol Surg"},{"key":"R18-20230812","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1253\/jcj.55.567","article-title":"Pressure-volume relationships of finger arteries in healthy subjects and patients with coronary atherosclerosis measured non-invasively by photoelectric plethysmography.","volume":"55","author":"Ando","year":"1991","journal-title":"Jpn Circ J"},{"key":"R19-20230812","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/S0895-7061(99)00192-2","article-title":"Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity.","volume":"13","author":"Bortolotto","year":"2000","journal-title":"Am J Hypertens"},{"key":"R20-20230812","doi-asserted-by":"crossref","first-page":"2007","DOI":"10.1016\/S0735-1097(99)00441-6","article-title":"Photoplethysmographic assessment of pulse wave reflection: blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus.","volume":"34","author":"Chowienczyk","year":"1999","journal-title":"J Am Coll Cardiol"},{"key":"R21-20230812","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/0141-5425(91)90127-S","article-title":"Quantitative measurement of sympathetic neuropathy in patients with diabetes mellitus.","volume":"13","author":"Nasimi","year":"1991","journal-title":"J Biomed Eng"},{"key":"R22-20230812","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1111\/j.1399-6576.1995.tb04328.x","article-title":"Quantifying pulmonary oxygen transfer deficits in critically ill patients.","volume":"107","author":"Wandrup","year":"1995","journal-title":"Acta Anaesthesiol Scand Suppl"},{"key":"R23-20230812","first-page":"375","article-title":"The PIO2 vs. SpO2 diagram: a non-invasive measure of pulmonary oxygen exchange.","volume":"12","author":"Sapsford","year":"1995","journal-title":"Eur J Anaesthesiol"},{"key":"R24-20230812","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1023\/A:1011495416005","article-title":"Discriminating between the effect of shunt and reduced VA\/Q on arterial oxygen saturation is particularly useful in clinical practice.","volume":"16","author":"Jones","year":"2000","journal-title":"J Clin Monit Comput"},{"key":"R25-20230812","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1007\/s00134-003-1708-0","article-title":"Non-invasive estimation of shunt and ventilation-perfusion mismatch.","volume":"29","author":"Kjaergaard","year":"2003","journal-title":"Intensive Care Med"},{"key":"R26-20230812","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1111\/j.1399-6576.1986.tb02393.x","article-title":"Correlation of gas exchange impairment to development of atelectasis during anaesthesia and muscle paralysis.","volume":"30","author":"Hedenstierna","year":"1986","journal-title":"Acta Anaesthesiol Scand"},{"key":"R27-20230812","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1093\/bja\/aeg085","article-title":"New concepts of atelectasis during general anaesthesia.","volume":"91","author":"Magnusson","year":"2003","journal-title":"Br J Anaesth"},{"key":"R28-20230812","doi-asserted-by":"crossref","first-page":"1701","DOI":"10.1164\/ajrccm.164.9.2103121","article-title":"What has computed tomography taught us about the acute respiratory distress syndrome?","volume":"164","author":"Gattinoni","year":"2001","journal-title":"Am J Respir Crit Care Med"},{"key":"R29-20230812","doi-asserted-by":"crossref","first-page":"F127","DOI":"10.1136\/fn.85.2.F127","article-title":"Non-invasive assessment of shunt and ventilation\/perfusion ratio in neonates with pulmonary failure.","volume":"85","author":"Smith","year":"2001","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"R30-20230812","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1111\/j.1365-2044.1997.153-az0159.x","article-title":"A noninvasive method for evaluating the effect of thoracotomy on shunt and ventilation perfusion inequality.","volume":"52","author":"de Gray","year":"1997","journal-title":"Anaesthesia"},{"key":"R31-20230812","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1213\/01.ane.0000438350.29240.08","article-title":"Noninvasive monitoring of lung recruitment maneuvers in morbidly obese patients: the role of pulse oximetry and volumetric capnography.","volume":"118","author":"Tusman","year":"2014","journal-title":"Anesth Analg"},{"key":"R32-20230812","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1097\/ALN.0b013e3181fc6e0a","article-title":"Prediction of postoperative pulmonary complications in a population-based surgical cohort.","volume":"113","author":"Canet","year":"2010","journal-title":"Anesthesiology"},{"key":"R33-20230812","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/BF02584226","article-title":"Physiological and pathophysiological implications of ventricular\/vascular coupling.","volume":"12","author":"O\u2019Rourke","year":"1984","journal-title":"Ann Biomed Eng"},{"key":"R35-20230812","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1152\/jappl.1967.23.2.139","article-title":"Pressure and flow waves in systemic arteries and the anatomical design of the arterial system.","volume":"23","author":"O\u2019Rourke","year":"1967","journal-title":"J Appl Physiol"},{"key":"R36-20230812","doi-asserted-by":"crossref","first-page":"473","DOI":"10.33549\/physiolres.931468","article-title":"Parameters describing the pulse wave.","volume":"58","author":"Korpas","year":"2009","journal-title":"Physiol Res"},{"key":"R37-20230812","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1007\/BF02447713","article-title":"What does photoplethysmography measure?","volume":"22","author":"de Trafford","year":"1984","journal-title":"Med Biol Eng Comput"},{"key":"R38-20230812","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1109\/10.52332","article-title":"Frequency analysis of the peripheral pulse wave detected in the finger with a photoplethysmograph.","volume":"37","author":"Sherebrin","year":"1990","journal-title":"IEEE Trans Biomed Eng"},{"key":"R39-20230812","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1097\/00000542-198710000-00032","article-title":"Blood flow limits and pulse oximeter signal detection.","volume":"67","author":"Lawson","year":"1987","journal-title":"Anesthesiology"},{"key":"R40-20230812","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1046\/j.1365-2044.2001.01987.x","article-title":"Arterial flow waveforms from pulse oximetry compared with measured Doppler flow waveforms apparatus.","volume":"56","author":"Wisely","year":"2001","journal-title":"Anaesthesia"},{"key":"R41-20230812","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1161\/01.HYP.36.6.952","article-title":"Noninvasive assessment of the digital volume pulse. Comparison with the peripheral pressure pulse.","volume":"36","author":"Millasseau","year":"2000","journal-title":"Hypertension"},{"key":"R42-20230812","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1177\/000331978803900906","article-title":"Noninvasive measurement of the human peripheral circulation: relationship between laser Doppler flowmeter and photoplethysmograph signals from the finger.","volume":"39","author":"Almond","year":"1988","journal-title":"Angiology"},{"key":"R43-20230812","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1056\/NEJMoa010307","article-title":"Early goal-directed therapy in the treatment of severe sepsis and septic shock.","volume":"345","author":"Rivers","year":"2001","journal-title":"N Engl J Med"},{"key":"R44-20230812","doi-asserted-by":"crossref","first-page":"2564","DOI":"10.1056\/NEJMoa062200","article-title":"Comparison of two fluid management strategies in acute lung injury.","volume":"354","author":"Wiedemann","year":"2006","journal-title":"N Engl J Med"},{"key":"R45-20230812","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1097\/ALN.0000000000000756","article-title":"Association between intraoperative hypotension and hypertension and 30-day postoperative mortality in noncardiac surgery.","volume":"123","author":"Monk","year":"2015","journal-title":"Anesthesiology"},{"key":"R46-20230812","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1007\/s10877-011-9316-y","article-title":"Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers. Part 1: time domain analysis.","volume":"25","author":"Alian","year":"2011","journal-title":"J Clin Monit Comput"},{"key":"R47-20230812","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1007\/BF03337381","article-title":"Use of pulse oximetry as a noninvasive indicator of intravascular volume status.","volume":"3","author":"Partridge","year":"1987","journal-title":"J Clin Monit"},{"key":"R48-20230812","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/BF02077634","article-title":"The peripheral pulse wave: information overlooked.","volume":"12","author":"Murray","year":"1996","journal-title":"J Clin Monit"},{"key":"R49-20230812","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1093\/bja\/82.2.178","article-title":"Pulse oximetry plethysmographic waveform during changes in blood volume.","volume":"82","author":"Shamir","year":"1999","journal-title":"Br J Anaesth"},{"key":"R50-20230812","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1213\/01.ane.0000246811.88524.75","article-title":"Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: a clinical trial.","volume":"103","author":"Natalini","year":"2006","journal-title":"Anesth Analg"},{"key":"R51-20230812","doi-asserted-by":"crossref","first-page":"R562","DOI":"10.1186\/cc3799","article-title":"Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients.","volume":"9","author":"Cannesson","year":"2005","journal-title":"Crit Care"},{"key":"R52-20230812","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1097\/01.anes.0000267593.72744.20","article-title":"Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room.","volume":"106","author":"Cannesson","year":"2007","journal-title":"Anesthesiology"},{"key":"R53-20230812","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1093\/bja\/aen133","article-title":"Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.","volume":"101","author":"Cannesson","year":"2008","journal-title":"Br J Anaesth"},{"key":"R54-20230812","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1213\/ane.0b013e318167ab1f","article-title":"Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?","volume":"106","author":"Cannesson","year":"2008","journal-title":"Anesth Analg"},{"key":"R55-20230812","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1088\/0967-3334\/28\/4\/009","article-title":"Automatic detection of left ventricular ejection time from a finger photoplethysmographic pulse oximetry waveform: comparison with Doppler aortic measurement.","volume":"28","author":"Chan","year":"2007","journal-title":"Physiol Meas"},{"key":"R56-20230812","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1097\/01.TA.0000063406.34651.E5","article-title":"Decrease in left ventricular ejection time on digital arterial waveform during simulated hypovolemia in normal humans.","volume":"56","author":"Geeraerts","year":"2004","journal-title":"J Trauma"},{"key":"R57-20230812","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1111\/j.1475-097X.2008.00843.x","article-title":"Changes in left ventricular ejection time and pulse transit time derived from finger photoplethysmogram and electrocardiogram during moderate haemorrhage.","volume":"29","author":"Middleton","year":"2009","journal-title":"Clin Physiol Funct Imaging"},{"key":"R58-20230812","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1152\/japplphysiol.00435.2003","article-title":"The respiratory change in preejection period: a new method to predict fluid responsiveness.","volume":"96","author":"Bendjelid","year":"2004","journal-title":"J Appl Physiol (1985)"},{"key":"R59-20230812","doi-asserted-by":"crossref","first-page":"2534","DOI":"10.1097\/01.CCM.0000186415.43713.2F","article-title":"Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients.","volume":"33","author":"Feissel","year":"2005","journal-title":"Crit Care Med"},{"key":"R60-20230812","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1093\/oxfordjournals.aje.a117315","article-title":"Arterial stiffness: a new cardiovascular risk factor?","volume":"140","author":"Arnett","year":"1994","journal-title":"Am J Epidemiol"},{"key":"R61-20230812","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1042\/cs1030371","article-title":"Determination of age-related increases in large artery stiffness by digital pulse contour analysis.","volume":"103","author":"Millasseau","year":"2002","journal-title":"Clin Sci (Lond)"},{"key":"R62-20230812","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1088\/0967-3334\/24\/2\/306","article-title":"Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites.","volume":"24","author":"Allen","year":"2003","journal-title":"Physiol Meas"},{"key":"R63-20230812","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1161\/01.HYP.32.2.365","article-title":"Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform.","volume":"32","author":"Takazawa","year":"1998","journal-title":"Hypertension"},{"key":"R64-20230812","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1536\/ihj.39.775","article-title":"Correlation between wave components of the second derivative of plethysmogram and arterial distensibility.","volume":"39","author":"Imanaga","year":"1998","journal-title":"Jpn Heart J"},{"issue":"Suppl 6","key":"R65-20230812","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1111\/j.1600-0773.1986.tb02551.x","article-title":"Digital pulse plethysmography (DPG) in studies of the hemodynamic response to nitrates\u2014a survey of recording methods and principles of analysis.","volume":"59","author":"Lund","year":"1986","journal-title":"Acta Pharmacol Toxicol (Copenh)"},{"key":"R66-20230812","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1097\/00000542-199811000-00041","article-title":"Skin vasomotor reflex as a measure of depth of anesthesia.","volume":"89","author":"Ezri","year":"1998","journal-title":"Anesthesiology"},{"key":"R67-20230812","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1088\/0967-3334\/27\/7\/008","article-title":"The effect of local mild cold exposure on pulse transit time.","volume":"27","author":"Zhang","year":"2006","journal-title":"Physiol Meas"},{"key":"R68-20230812","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1097\/00000539-200106000-00026","article-title":"Different responses of ear and finger pulse oximeter wave form to cold pressor test.","volume":"92","author":"Awad","year":"2001","journal-title":"Anesth Analg"},{"key":"R69-20230812","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s10877-007-9097-5","article-title":"The relationship between the photoplethysmographic waveform and systemic vascular resistance.","volume":"21","author":"Awad","year":"2007","journal-title":"J Clin Monit Comput"},{"key":"R70-20230812","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1088\/0967-3334\/32\/8\/008","article-title":"Multivariate classification of systemic vascular resistance using photoplethysmography.","volume":"32","author":"Lee","year":"2011","journal-title":"Physiol Meas"},{"key":"R71-20230812","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1097\/00003246-200206000-00006","article-title":"Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion.","volume":"30","author":"Lima","year":"2002","journal-title":"Crit Care Med"},{"key":"R72-20230812","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1007\/s00431-002-1042-5","article-title":"The pulse oximeter perfusion index as a predictor for high illness severity in neonates.","volume":"161","author":"De Felice","year":"2002","journal-title":"Eur J Pediatr"},{"key":"R73-20230812","doi-asserted-by":"crossref","first-page":"266","DOI":"10.2478\/v10048-012-0036-3","article-title":"The analysis of PPG morphology: investigating the effects of aging on arterial compliance.","volume":"12","author":"Yousef","year":"2012","journal-title":"Measurement Sci Rev"},{"key":"R75-20230812","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/S0002-8703(41)90966-3","article-title":"The form of the volume pulse in the finger pad in health, arteriosclerosis, and hypertension.","volume":"21","author":"Dillon","year":"1941","journal-title":"Am Heart J"},{"key":"R76-20230812","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/0021-9681(56)90158-8","article-title":"Studies of the arterial pulse wave. I. The normal pulse wave and its modification in the presence of human arteriosclerosis.","volume":"3","author":"Lax","year":"1956","journal-title":"J Chronic Dis"},{"key":"R77-20230812","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1177\/000331977302400407","article-title":"Characteristics of the dicrotic notch of the arterial pulse wave in coronary heart disease.","volume":"24","author":"Dawber","year":"1973","journal-title":"Angiology"},{"key":"R78-20230812","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1038\/213841a0","article-title":"Characteristic pulse wave caused by organic nitrates.","volume":"213","author":"Morikawa","year":"1967","journal-title":"Nature"},{"key":"R79-20230812","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1007\/s002280050108","article-title":"Digital pulse plethysmography as a non-invasive method for predicting drug-induced changes in left ventricular preload.","volume":"50","author":"Stengele","year":"1996","journal-title":"Eur J Clin Pharmacol"},{"key":"R80-20230812","doi-asserted-by":"crossref","first-page":"2339","DOI":"10.1097\/01.CCM.0000182801.48137.13","article-title":"Effects of norepinephrine on static and dynamic preload indicators in experimental hemorrhagic shock.","volume":"33","author":"Nouira","year":"2005","journal-title":"Crit Care Med"},{"key":"R81-20230812","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1590\/S1807-59322010000200011","article-title":"Vasodilation increases pulse pressure variation, mimicking hypovolemic status in rabbits.","volume":"65","author":"Westphal","year":"2010","journal-title":"Clinics (Sao Paulo)"},{"key":"R82-20230812","doi-asserted-by":"crossref","first-page":"328.e1","DOI":"10.1016\/j.jcrc.2010.08.018","article-title":"The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients.","volume":"26","author":"Hadian","year":"2011","journal-title":"J Crit Care"},{"key":"R83-20230812","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/00000542-200702000-00026","article-title":"General anesthetics and vascular smooth muscle: direct actions of general anesthetics on cellular mechanisms regulating vascular tone.","volume":"106","author":"Akata","year":"2007","journal-title":"Anesthesiology"},{"key":"R84-20230812","doi-asserted-by":"crossref","first-page":"S31","DOI":"10.1213\/01.ane.0000269512.82836.c9","article-title":"Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate.","volume":"105","author":"Shelley","year":"2007","journal-title":"Anesth Analg"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201701000-00012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:17:54Z","timestamp":1786112274000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201701000-00012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":82,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000001283","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.726360487.793574373","asserted-by":"object"}]},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2017,1]]}}}