{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T13:39:21Z","timestamp":1794836361827,"version":"4.9.1"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,7]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Even as the use of peripheral nerve blockade in the perioperative setting is increasing, neural injury secondary to accidental intraneural injection remains a significant patient safety concern. Current modalities, including electrical stimulation and ultrasound imaging, still lack consistency and absolute reliability in both the detection and prevention of this complication. The measurement of electrical impedance (EI) could be an easy and valuable additional tool to detect intraneural needle placement. Our objectives in this study were to measure the change in EI with intraneural needle advancement in recently amputated human limbs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>The study was conducted within 45 minutes of amputation. The nerves that were studied were the sciatic nerve in the popliteal fossa in above-knee amputations or the tibial nerve below the calf in below-knee amputations. The amputated limb was placed on a tray and under ultrasound imaging guidance, an insulated peripheral block needle connected to a nerve stimulator was placed extraneurally and subsequently advanced intraneurally. The experiment was repeated on the same nerve after exposure by surgical dissection. The differences in impedance measurements between intraneural and extraneural needle placement were compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      In the below-knee amputated extremity (tibial nerve,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 6) specimens based on the ultrasound methods, mean \u00b1 SD for ultrasound-guided intraneural impedance was 10 \u00b1 2 k\u03a9 compared with an extraneural impedance of 6 \u00b1 1.6 k\u03a9 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.005). The difference between intraneural and extraneural impedance after open dissection was also significant when we repeated the analysis based on the same specimens (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.005). Similarly, in the above-the-knee amputated extremity (sciatic nerve,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 5) specimens, mean intraneural impedance was 35.2 \u00b1 7.9 k\u03a9 compared with an extraneural impedance of 25.2 \u00b1 5.3 k\u03a9 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.037). The difference between intraneural and extraneural impedance obtained after open dissection was also significant when we repeated the analysis based on the same specimens (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.0002). The impedance values were consistent and similar to those obtained after open dissection.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>There is no reliable \u201cgold standard\u201d to predict or prevent intraneural needle placement during peripheral nerve blockade. This small sample-sized study demonstrated that there is a change in EI with intraneural needle advancement. In clinical practice, measurement of the EI in conjunction with nerve stimulation may serve as another tool to use for identifying intraneural needle placement during peripheral nerve blockade.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000001332","type":"journal-article","created":{"date-parts":[[2016,6,18]],"date-time":"2016-06-18T03:42:41Z","timestamp":1466221361000},"page":"228-232","source":"Crossref","is-referenced-by-count":11,"title":["The Use of Electrical Impedance to Identify Intraneural Needle Placement in Human Peripheral Nerves: A Study on Amputated Human Limbs"],"prefix":"10.1213","volume":"123","author":[{"given":"Amaresh","family":"Vydyanathan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boleslav","family":"Kosharskyy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Singh","family":"Nair","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karina","family":"Gritsenko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryung S.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naum","family":"Shaparin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230721","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1097\/00008506-200401000-00018","article-title":"Complications of regional anesthesia: nerve injury and peripheral neural blockade.","volume":"16","author":"Liguori","year":"2004","journal-title":"J Neurosurg Anesthesiol"},{"issue":"suppl 1","key":"R2-20230721","doi-asserted-by":"crossref","first-page":"i97","DOI":"10.1093\/bja\/aeq273","article-title":"Complications of peripheral nerve blocks.","volume":"105","author":"Jeng","year":"2010","journal-title":"Br J Anaesth"},{"key":"R3-20230721","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1097\/00000637-199611000-00019","article-title":"Injection injury to the median nerve.","volume":"37","author":"Fremling","year":"1996","journal-title":"Ann Plast Surg"},{"key":"R4-20230721","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1097\/00000542-199709000-00005","article-title":"Serious complications related to regional anesthesia: results of a prospective survey in France.","volume":"87","author":"Auroy","year":"1997","journal-title":"Anesthesiology"},{"key":"R5-20230721","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.bpa.2011.02.007","article-title":"Closed claims\u2019 analysis.","volume":"25","author":"Metzner","year":"2011","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"R6-20230721","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1097\/ALN.0b013e3181bbc72a","article-title":"Differences in quantitative architecture of sciatic nerve may explain differences in potential vulnerability to nerve injury, onset time, and minimum effective anesthetic volume.","volume":"111","author":"Moayeri","year":"2009","journal-title":"Anesthesiology"},{"key":"R7-20230721","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1097\/01.anes.0000299833.73804.cd","article-title":"Severe brachial plexopathy after an ultrasound-guided single-injection nerve block for total shoulder arthroplasty in a patient with multiple sclerosis.","volume":"108","author":"Koff","year":"2008","journal-title":"Anesthesiology"},{"key":"R8-20230721","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1097\/ALN.0b013e318182c288","article-title":"Electrical impedance to distinguish intraneural from extraneural needle placement in porcine nerves during direct exposure and ultrasound guidance.","volume":"109","author":"Tsui","year":"2008","journal-title":"Anesthesiology"},{"key":"R9-20230721","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1007\/s12630-012-9845-y","article-title":"Electrical impedance to detect accidental nerve puncture during ultrasound-guided peripheral nerve blocks.","volume":"60","author":"Bardou","year":"2013","journal-title":"Can J Anaesth"},{"key":"R10-20230721","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1213\/ane.0b013e3181957d84","article-title":"Current threshold for nerve stimulation depends on electrical impedance of the tissue: a study of ultrasound-guided electrical nerve stimulation of the median nerve.","volume":"108","author":"Sauter","year":"2009","journal-title":"Anesth Analg"},{"key":"R11-20230721","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1097\/ALN.0b013e3181a59891","article-title":"Extraneural versus intraneural stimulation thresholds during ultrasound-guided supraclavicular block.","volume":"110","author":"Bigeleisen","year":"2009","journal-title":"Anesthesiology"},{"key":"R12-20230721","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00115550-200805000-00003","article-title":"Intensity of the stimulating current may not be a reliable indicator of intraneural needle placement.","volume":"33","author":"Tsai","year":"2008","journal-title":"Reg Anesth Pain Med"},{"key":"R13-20230721","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1113\/jphysiol.1991.sp018765","article-title":"Changes in excitability and accommodation of human motor axons following brief periods of ischaemia.","volume":"441","author":"Bostock","year":"1991","journal-title":"J Physiol"},{"key":"R14-20230721","doi-asserted-by":"crossref","first-page":"2542","DOI":"10.1093\/brain\/123.12.2542","article-title":"Effects of membrane polarization and ischaemia on the excitability properties of human motor axons.","volume":"123","author":"Kiernan","year":"2000","journal-title":"Brain"},{"key":"R15-20230721","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1111\/anae.12540","article-title":"The effects of general anaesthesia on nerve-motor response characteristics (rheobase and chronaxie) to peripheral nerve stimulation.","volume":"69","author":"Tsui","year":"2014","journal-title":"Anaesthesia"},{"key":"R16-20230721","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1038\/286498a0","article-title":"Interaction of anaesthetics with electrical synapses.","volume":"286","author":"Johnston","year":"1980","journal-title":"Nature"},{"key":"R17-20230721","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1007\/BF02443872","article-title":"Electrical conductivity of skeletal muscle tissue: experimental results from different muscles in vivo.","volume":"22","author":"Gielen","year":"1984","journal-title":"Med Biol Eng Comput"},{"key":"R18-20230721","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1097\/00000542-200304000-00026","article-title":"Nerve stimulators used for peripheral nerve blocks vary in their electrical characteristics.","volume":"98","author":"Hadzic","year":"2003","journal-title":"Anesthesiology"},{"key":"R19-20230721","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1213\/ANE.0b013e3182a00767","article-title":"Peripheral nerve injury after local anesthetic injection.","volume":"117","author":"Farber","year":"2013","journal-title":"Anesth Analg"},{"key":"R20-20230721","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1213\/ANE.0b013e3181de574e","article-title":"Ropivacaine-induced peripheral nerve injection injury in the rodent model.","volume":"111","author":"Whitlock","year":"2010","journal-title":"Anesth Analg"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201607000-00029","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:18:47Z","timestamp":1786112327000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201607000-00029"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000001332","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7]]}}}