{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T20:50:54Z","timestamp":1792270254163,"version":"4.4.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Core temperature can be accurately measured from the esophagus or nasopharynx during general anesthesia, but neither site is suitable for neuraxial anesthesia. We therefore determined the precision and accuracy of a novel wireless axillary thermometer, the iThermonitor, to determine its suitability for use during neuraxial anesthesia and in other patients who are not intubated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We enrolled 80 adults having upper abdominal surgery with endotracheal intubation. Intraoperative core temperature was measured in distal esophagus and was estimated at the axilla with a wireless iThermonitor WT701 (Raiing Medical, Boston MA) at 5-minute intervals. Pairs of axillary and reference distal esophageal temperatures were compared and summarized using linear regression and repeated-measured Bland\u2013Altman methods. We a priori determined that the iThermonitor would have clinically acceptable accuracy if most estimates were within \u00b10.5\u00b0C of the esophageal reference, and suitable precision if the limits of agreement were within \u00b10.5\u00b0C.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>There were 3339 sets of paired temperatures. Axillary and esophageal temperatures were similar, with a mean difference (esophageal minus axillary) of only 0.14\u00b0C \u00b1 0.26\u00b0C (standard deviation). The Bland\u2013Altman 95% limits of agreement were reasonably narrow, with the estimated upper limit at 0.66\u00b0C and the lower limit at \u22120.38\u00b0C, thus \u00b10.52\u00b0C, indicating good agreement across the range of mean temperatures from 34.9\u00b0C to 38.1\u00b0C. The absolute difference was within 0.5\u00b0C in 91% of the measurements (95% confidence interval, 88%\u201393%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Axillary temperature, as recorded by the iThermonitor WT701, well represents core temperature in adults having noncardiac surgery and thus appears suitable for clinical use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000002706","type":"journal-article","created":{"date-parts":[[2017,12,30]],"date-time":"2017-12-30T06:30:25Z","timestamp":1514615425000},"page":"833-838","source":"Crossref","is-referenced-by-count":35,"title":["Axillary Temperature, as Recorded by the iThermonitor WT701, Well Represents Core Temperature in Adults Having Noncardiac Surgery"],"prefix":"10.1213","volume":"126","author":[{"given":"Lijian","family":"Pei","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Peking Union Medical College Hospital, Beijing, China"},{"name":"Outcomes Research Consortium, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuguang","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Peking Union Medical College Hospital, Beijing, China"},{"name":"Outcomes Research Consortium, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guangmei","family":"Mao","sequence":"additional","affiliation":[{"name":"Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio"},{"name":"Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel I.","family":"Sessler","sequence":"additional","affiliation":[{"name":"Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230721","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1097\/ALN.0b013e31817f6d76","article-title":"Temperature monitoring and perioperative thermoregulation.","volume":"109","author":"Sessler","year":"2008","journal-title":"Anesthesiology"},{"key":"R2-20230721","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1097\/00000542-200002000-00042","article-title":"Perioperative heat balance.","volume":"92","author":"Sessler","year":"2000","journal-title":"Anesthesiology"},{"key":"R3-20230721","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1097\/00000542-200108000-00040","article-title":"Complications and treatment of mild hypothermia.","volume":"95","author":"Sessler","year":"2001","journal-title":"Anesthesiology"},{"key":"R4-20230721","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/1750-1172-2-21","article-title":"Malignant hyperthermia.","volume":"2","author":"Rosenberg","year":"2007","journal-title":"Orphanet J Rare Dis"},{"key":"R5-20230721","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1097\/00000542-199811000-00061","article-title":"A proposal for new temperature monitoring and thermal management guidelines.","volume":"89","author":"Sessler","year":"1998","journal-title":"Anesthesiology"},{"key":"R6-20230721","doi-asserted-by":"crossref","first-page":"2655","DOI":"10.1016\/S0140-6736(15)00981-2","article-title":"Perioperative thermoregulation and heat balance.","volume":"387","author":"Sessler","year":"2016","journal-title":"Lancet"},{"key":"R7-20230721","doi-asserted-by":"crossref","first-page":"1434","DOI":"10.1213\/ANE.0000000000001213","article-title":"Optimal depth for nasopharyngeal temperature probe positioning.","volume":"122","author":"Wang","year":"2016","journal-title":"Anesth Analg"},{"key":"R8-20230721","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.bpa.2008.07.006","article-title":"Thermal management during anaesthesia and thermoregulation standards for the prevention of inadvertent perioperative hypothermia.","volume":"22","author":"Torossian","year":"2008","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"R9-20230721","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1213\/ANE.0000000000000319","article-title":"An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients.","volume":"119","author":"Eshraghi","year":"2014","journal-title":"Anesth Analg"},{"key":"R10-20230721","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1097\/ALN.0b013e3181a864ca","article-title":"Noninvasive temperature monitoring in postanesthesia care units.","volume":"111","author":"Langham","year":"2009","journal-title":"Anesthesiology"},{"key":"R11-20230721","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1152\/jappl.1990.69.1.376","article-title":"Determination of esophageal probe insertion length based on standing and sitting height.","volume":"69","author":"Mekjavi\u0107","year":"1990","journal-title":"J Appl Physiol (1985)"},{"key":"R12-20230721","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1097\/00000542-199112000-00010","article-title":"Isoflurane anesthesia and circadian temperature cycles in humans.","volume":"75","author":"Sessler","year":"1991","journal-title":"Anesthesiology"},{"key":"R13-20230721","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1007\/s004240050530","article-title":"Circadian changes in the sweating-to-vasoconstriction interthreshold range.","volume":"435","author":"Tayefeh","year":"1998","journal-title":"Pflugers Arch"},{"key":"R14-20230721","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1080\/10543400701329422","article-title":"Agreement between methods of measurement with multiple observations per individual.","volume":"17","author":"Bland","year":"2007","journal-title":"J Biopharm Stat"},{"key":"R15-20230721","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1177\/0962280211402548","article-title":"Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual.","volume":"22","author":"Zou","year":"2013","journal-title":"Stat Methods Med Res"},{"key":"R16-20230721","doi-asserted-by":"crossref","first-page":"255","DOI":"10.2307\/2532051","article-title":"A concordance correlation coefficient to evaluate reproducibility.","volume":"45","author":"Lin","year":"1989","journal-title":"Biometrics"},{"key":"R17-20230721","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1080\/10543400802527890","article-title":"The concordance correlation coefficient for repeated measures estimated by variance components.","volume":"19","author":"Carrasco","year":"2009","journal-title":"J Biopharm Stat"},{"key":"R18-20230721","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.cmpb.2012.09.002","article-title":"Estimation of the concordance correlation coefficient for repeated measures using SAS and R.","volume":"109","author":"Carrasco","year":"2013","journal-title":"Comput Methods Programs Biomed"},{"key":"R19-20230721","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1213\/00000539-198908000-00009","article-title":"Intraoperative temperature monitoring sites in infants and children and the effect of inspired gas warming on esophageal temperature.","volume":"69","author":"Bissonnette","year":"1989","journal-title":"Anesth Analg"},{"key":"R20-20230721","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1007\/BF03012021","article-title":"Oesophageal, rectal, axillary, tympanic and pulmonary artery temperatures during cardiac surgery.","volume":"45","author":"Robinson","year":"1998","journal-title":"Can J Anaesth"},{"key":"R21-20230721","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1097\/00000542-198812000-00037","article-title":"Does urinary catheter temperature reflect core temperature during cardiac surgery?","volume":"69","author":"Horrow","year":"1988","journal-title":"Anesthesiology"},{"key":"R22-20230721","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1017\/S0265021508004602","article-title":"Urinary bladder and oesophageal temperatures correlate better in patients with high rather than low urinary flow rates during non-cardiac surgery.","volume":"25","author":"Sato","year":"2008","journal-title":"Eur J Anaesthesiol"},{"key":"R23-20230721","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1097\/00000542-199711000-00013","article-title":"Efficacy of intraoperative cooling methods.","volume":"87","author":"Plattner","year":"1997","journal-title":"Anesthesiology"},{"key":"R24-20230721","first-page":"803","article-title":"Thermal response in acute porcine malignant hyperthermia.","volume":"82","author":"Iaizzo","year":"1996","journal-title":"Anesth Analg"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201803000-00022","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:27:05Z","timestamp":1786112825000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201803000-00022"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000002706","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.732392479.793560076","asserted-by":"object"}]},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2018,3]]}}}