{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:22:40Z","timestamp":1786123360810,"version":"build-2736575974"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,5]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Nasotracheal intubation is commonly performed to provide a secure airway for the maintenance of general anesthesia in maxillofacial surgeries. Routine nasotracheal intubation is performed under general anesthesia by direct laryngoscopy, frequently with the aid of Magill forceps. This method can be time-consuming and may cause bleeding in the field of view. A gum elastic bougie (GEB) is a cheap, slender, and flexible device that could expedite nasotracheal intubation. The aim of this study was to evaluate the use of a GEB during nasotracheal intubation to facilitate the procedure and reduce the rate of complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>In this randomized clinical trial study, 110 patients with American Society of Anesthesiologists (ASA) physical status I\u2013II from 15 to 65 years of age were randomized into 2 equal groups. In both groups, a GlideScope and armored tube were used. In the GEB group, GEB was used to facilitate nasal intubation while the nasal intubation was performed without the aid of GEB in the routine group. The difficult intubation (defined as &gt;1 attempt for intubation) was the primary outcome, and the duration of the intubation, the presence of traces of bleeding, the need for a tube replacement, and the usage of Magill forceps were the secondary outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      The incidence of bleeding in the GEB group was 1.81% vs 43.63% in the routine group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001). In 5.5% of the GEB group, Magill forceps were used to advance the tube versus 67.3% in the routine group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001). The mean time for intubation in GEB group was 48.63 \u00b1 8.53 vs 55.9 \u00b1 10.76 seconds in the routine group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>The GEB is a useful aid to nasotracheal intubation, reducing bleeding, the requirement for Magill forceps and, to a small degree, intubation time. A case exists for its routine use for this purpose.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000002853","type":"journal-article","created":{"date-parts":[[2018,2,4]],"date-time":"2018-02-04T17:05:47Z","timestamp":1517763947000},"page":"1641-1645","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of Nasal Intubations by GlideScope With and Without a Bougie Guide in Patients Who Underwent Maxillofacial Surgeries: Randomized Clinical Trial"],"prefix":"10.1213","volume":"126","author":[{"given":"Pejman","family":"Pourfakhr","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Sina Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ailar","family":"Ahangari","sequence":"additional","affiliation":[{"name":"Tehran University of Medical Sciences, Tehran, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farhad","family":"Etezadi","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Sina Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reza Shariat","family":"Moharari","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Sina Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayat","family":"Ahmadi","sequence":"additional","affiliation":[{"name":"Knowledge Utilization Research Center, Tehran University of Medical Sciences, Tehran, Iran."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Negin","family":"Saeedi","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Sina Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atabak","family":"Najafi","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Sina Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230721","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1213\/01.ane.0000196507.19771.b2","article-title":"Predictive performance of three multivariate difficult tracheal intubation models: a double-blind, case-controlled study.","volume":"102","author":"Naguib","year":"2006","journal-title":"Anesth Analg"},{"key":"R2-20230721","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1093\/bja\/65.3.400","article-title":"Failed tracheal intubation.","volume":"65","author":"King","year":"1990","journal-title":"Br J Anaesth"},{"key":"R4-20230721","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/0278-2391(83)90129-5","article-title":"Ankylosis of the mandible: analysis of 76 cases.","volume":"41","author":"Adekeye","year":"1983","journal-title":"J Oral Maxillofac Surg"},{"key":"R5-20230721","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1111\/j.1365-2044.2005.04516.x","article-title":"Use of a gum elastic bougie to facilitate blind nasotracheal intubation in children: a series of three cases.","volume":"61","author":"Arora","year":"2006","journal-title":"Anaesthesia"},{"key":"R7-20230721","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1213\/00000539-200009000-00038","article-title":"Thermosoftening treatment of the nasotracheal tube before intubation can reduce epistaxis and nasal damage.","volume":"91","author":"Kim","year":"2000","journal-title":"Anesth Analg"},{"key":"R8-20230721","doi-asserted-by":"crossref","first-page":"1782","DOI":"10.1097\/00000542-199906000-00039","article-title":"Accidental middle turbinectomy: a complication of nasal intubation.","volume":"90","author":"Williams","year":"1999","journal-title":"Anesthesiology"},{"key":"R9-20230721","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1017\/S0022215100111387","article-title":"Infective complications of brief nasotracheal intubation.","volume":"103","author":"Hariri","year":"1989","journal-title":"J Laryngol Otol"},{"key":"R10-20230721","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1111\/j.1365-2044.1992.tb03154.x","article-title":"An evaluation of the gum elastic bougie. Intubation times and incidence of sore throat.","volume":"47","author":"Nolan","year":"1992","journal-title":"Anaesthesia"},{"key":"R11-20230721","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1111\/j.1365-2044.1990.tb14454.x","article-title":"Successful difficult intubation. Tracheal tube placement over a gum-elastic bougie.","volume":"45","author":"Dogra","year":"1990","journal-title":"Anaesthesia"},{"key":"R12-20230721","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1046\/j.1365-2044.2002.02411.x","article-title":"Survey of the use of the gum elastic bougie in clinical practice.","volume":"57","author":"Latto","year":"2002","journal-title":"Anaesthesia"},{"key":"R13-20230721","first-page":"29","article-title":"The Eschmann tracheal tube introducer (Gum elastic bougie).","volume":"19","author":"Viswanathan","year":"1992","journal-title":"Anesthesiol Rev"},{"key":"R14-20230721","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.ajem.2004.07.017","article-title":"Use of the endotracheal bougie introducer for difficult intubations.","volume":"22","author":"Phelan","year":"2004","journal-title":"Am J Emerg Med"},{"key":"R15-20230721","doi-asserted-by":"crossref","first-page":"112","DOI":"10.2344\/0003-3006-57.3.112","article-title":"Application of gum elastic bougie to nasal intubation.","volume":"57","author":"Arisaka","year":"2010","journal-title":"Anesth Prog"},{"key":"R16-20230721","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1213\/ane.0b013e31816d15c9","article-title":"A comparison of glidescope videolaryngoscopy to direct laryngoscopy for nasotracheal intubation.","volume":"107","author":"Jones","year":"2008","journal-title":"Anesth Analg"},{"key":"R17-20230721","first-page":"58","article-title":"Increased success of blind nasotracheal intubation through the use of nasogastric tubes as a guide.","volume":"43","author":"Sugiura","year":"1996","journal-title":"Anesth Prog"},{"key":"R18-20230721","doi-asserted-by":"crossref","first-page":"116","DOI":"10.4097\/kjae.2015.68.2.116","article-title":"Comparison of the rate of successful endotracheal intubation between the \u201csniffing\u201d and \u201cramped\u201d positions in patients with an expected difficult intubation: a prospective randomized study.","volume":"68","author":"Lee","year":"2015","journal-title":"Korean J Anesthesiol"},{"key":"R19-20230721","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1097\/00000539-200211000-00061","article-title":"Nasotracheal intubation: a simple and effective technique to reduce nasopharyngeal trauma and tube contamination.","volume":"95","author":"Enk","year":"2002","journal-title":"Anesth Analg"},{"key":"R20-20230721","first-page":"1140","article-title":"A \u201cbubble-tip\u201d (Airguide) tracheal tube system: its effects on incidence of epistaxis and ease of tube advancement in the subglottic region during nasotracheal intubation.","volume":"78","author":"Watanabe","year":"1994","journal-title":"Anesth Analg"},{"key":"R21-20230721","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1093\/bja\/aev371","article-title":"Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.","volume":"115","author":"Frerk","year":"2015","journal-title":"Br J Anaesth"},{"key":"R22-20230721","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1111\/j.1365-2044.1996.tb14961.x","article-title":"Simulated difficult intubation. Comparison of the gum elastic bougie and the stylet.","volume":"51","author":"Gataure","year":"1996","journal-title":"Anaesthesia"},{"key":"R23-20230721","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1097\/00000542-200201000-00014","article-title":"Nasotracheal intubation: a randomized trial of two methods.","volume":"96","author":"Elwood","year":"2002","journal-title":"Anesthesiology"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201805000-00034","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:28:06Z","timestamp":1786112886000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201805000-00034"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000002853","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]}}}