{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:16:14Z","timestamp":1792084574987,"version":"4.4.0"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,9]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Patient-controlled analgesia (PCA) is one of the most popular and effective methods for managing postoperative pain. Various types of continuous infusion pumps are available for the safe and accurate administration of analgesic drugs. Here we report the causes and clinical outcomes of device-related errors in PCA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Clinical records from January 1, 2011 to December 31, 2014 were collected by acute pain service team nurses in a 2715-bed tertiary hospital. Devices for all types of PCA, including intravenous PCA, epidural PCA, and nerve block PCA, were included for analysis. The following 4 types of infusion pumps were used during the study period: elastomeric balloon infusers, carbon dioxide-driven infusers, semielectronic disposable pumps, and electronic programmable pumps. We categorized PCA device-related errors based on the error mechanism and clinical features.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>Among 82,698 surgical patients using PCA, 610 cases (0.74%) were reported as human error, and 155 cases (0.19%) of device-related errors were noted during the 4-year study period. The most common type of device-related error was underflow, which was observed in 47 cases (30.3%). The electronic programmable pump exhibited the high incidence of errors in PCA (70 of 15,052 patients; 0.47%; 95% confidence interval, 0.36\u20130.59) among the 4 types of devices, and 96 of 152 (63%) patients experienced some type of adverse outcome, ranging from minor symptoms to respiratory arrest.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>The incidence of PCA device-related errors was &lt;0.2% and significantly differed according to the infusion pump type. A total of 63% of patients with PCA device-related errors suffered from adverse clinical outcomes, with no mortality. Recent technological advances may contribute to reducing the incidence and severity of PCA errors. Nonetheless, the results of this study can be used to improve patient safety and ensure quality care.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000003397","type":"journal-article","created":{"date-parts":[[2018,4,25]],"date-time":"2018-04-25T13:59:00Z","timestamp":1524664740000},"page":"720-725","source":"Crossref","is-referenced-by-count":12,"title":["Device-Related Error in Patient-Controlled Analgesia: Analysis of 82,698 Patients in a Tertiary Hospital"],"prefix":"10.1213","volume":"129","author":[{"given":"Hyo-Jung","family":"Son","sequence":"first","affiliation":[{"name":"Charit\u00e9 International Academy, Charite Universit\u00e4tmedizi, Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Hoon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeong-Ok","family":"Ryu","sequence":"additional","affiliation":[{"name":"Department of Nursing, Acute Pain Service Team, Asan Medical Center, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mi-Ra","family":"Kang","sequence":"additional","affiliation":[{"name":"Department of Nursing, Acute Pain Service Team, Asan Medical Center, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myeong-Hee","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Nursing, Acute Pain Service Team, Asan Medical Center, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeong-Hun","family":"Suh","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jai-Hyun","family":"Hwang","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230721","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1093\/bja\/87.1.62","article-title":"Effect of postoperative analgesia on surgical outcome.","volume":"87","author":"Kehlet","year":"2001","journal-title":"Br J Anaesth"},{"key":"R2-20230721","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/0952-8180(93)90013-5","article-title":"Postoperative patient-controlled analgesia: meta-analyses of initial randomized control trials.","volume":"5","author":"Ballantyne","year":"1993","journal-title":"J Clin Anaesth"},{"key":"R3-20230721","first-page":"CD","article-title":"Patient controlled opioid analgesia versus conventional opioid analgesia for postoperative pain.","author":"Hudcova","year":"2006","journal-title":"Cochrane Database Syst Rev"},{"key":"R4-20230721","first-page":"734","article-title":"Medication errors involving patient-controlled analgesia.","volume":"34","author":"Hicks","year":"2008","journal-title":"Jt Comm J Qual Patient Saf"},{"key":"R5-20230721","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1080\/J354v19n01_08","article-title":"Patient-controlled analgesia safety issues.","volume":"19","author":"Cohen","year":"2005","journal-title":"J Pain Palliat Care Pharmacother"},{"key":"R6-20230721","doi-asserted-by":"crossref","first-page":"429","DOI":"10.4097\/kjae.2016.69.5.429","article-title":"A first step toward understanding patient safety.","volume":"69","author":"Kim","year":"2016","journal-title":"Korean J Anesthesiol"},{"key":"R7-20230721","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1007\/BF03021849","article-title":"Morphine overdose from error propagation on an acute pain service.","volume":"53","author":"Syed","year":"2006","journal-title":"Can J Anaesth"},{"key":"R8-20230721","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1097\/ALN.0b013e3181fcb427","article-title":"Impact of a comprehensive safety initiative on patient-controlled analgesia errors.","volume":"113","author":"Paul","year":"2010","journal-title":"Anesthesiology"},{"key":"R9-20230721","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s11845-010-0482-6","article-title":"Five-year experience of critical incidents associated with patient-controlled analgesia in an Irish University Hospital.","volume":"179","author":"Ahmad","year":"2010","journal-title":"Ir J Med Sci"},{"key":"R10-20230721","doi-asserted-by":"crossref","first-page":"549","DOI":"10.2165\/00002018-200932070-00002","article-title":"Patient-controlled analgesia-related medication errors in the postoperative period: causes and prevention.","volume":"32","author":"Schein","year":"2009","journal-title":"Drug Saf"},{"key":"R11-20230721","doi-asserted-by":"crossref","first-page":"272","DOI":"10.4097\/kjae.2013.64.3.272","article-title":"Drug overdose due to malfunction of a patient-controlled analgesia machine: a case report.","volume":"64","author":"Yi","year":"2013","journal-title":"Korean J Anesthesiol"},{"key":"R12-20230721","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.2146\/ajhp060220","article-title":"Adverse events involving intravenous patient-controlled analgesia.","volume":"64","author":"Hankin","year":"2007","journal-title":"Am J Health Syst Pharm"},{"key":"R13-20230721","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1007\/BF03021027","article-title":"Programming errors contribute to death from patient-controlled analgesia: case report and estimate of probability.","volume":"50","author":"Vicente","year":"2003","journal-title":"Can J Anaesth"},{"key":"R14-20230721","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.2146\/ajhp050408","article-title":"Disposable infusion pumps.","volume":"63","author":"Skryabina","year":"2006","journal-title":"Am J Health Syst Pharm"},{"key":"R15-20230721","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1007\/BF03016678","article-title":"Safeguarding against errors with free flow protection devices of patient controlled analgesia systems.","volume":"55","author":"Neustein","year":"2008","journal-title":"Can J Anaesth"},{"key":"R16-20230721","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1097\/00000542-200105000-00050","article-title":"Electrical short circuit as a possible cause of death in patients on PCA machines: report on an opiate overdose and a possible preventive remedy.","volume":"94","author":"Doyle","year":"2001","journal-title":"Anesthesiology"},{"key":"R17-20230721","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1007\/BF03017218","article-title":"Another failure mechanism leading to patient-controlled analgesia overdoses.","volume":"55","author":"Doyle","year":"2008","journal-title":"Can J Anaesth"},{"key":"R18-20230721","doi-asserted-by":"crossref","first-page":"300","DOI":"10.4097\/kjae.2014.66.4.300","article-title":"Arrangements of the intravenous parallel infusions with anti-reflux valves decreasing occlusion alarm delay.","volume":"66","author":"Joe","year":"2014","journal-title":"Korean J Anesthesiol"},{"key":"R19-20230721","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1177\/106002809703100917","article-title":"Acute pain management: operative or medical procedures and trauma.","volume":"31","author":"Follin","year":"1997","journal-title":"Ann Pharmacother"},{"key":"R20-20230721","first-page":"153","article-title":"Evaluation of use of electronic patient controlled analgesia pumps to improve patient safety in an academic medical center.","volume":"201","author":"Ohashi","year":"2014","journal-title":"Stud Health Technol Inform"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000003397","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:19:27Z","timestamp":1786112367000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1213\/ANE.0000000000003397"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000003397","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2019,9]]}}}