{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:21:39Z","timestamp":1786123299810,"version":"build-2736575974"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Rotational thromboelastometry (ROTEM) can provide clinical information in 10\u201320 minutes for guiding administration of fibrinogen, platelets, and fresh frozen plasma products. While ROTEM testing is well established for cardiac and other surgeries, it is less characterized for use in postpartum hemorrhage (PPH) patients. We wanted to determine if the earlier-measured ROTEM parameters (\u03b1-angle and amplitude at 10 minutes [A10]) could replace the later parameters (amplitude at 20 minutes and maximum amplitude [maximum clot firmness {MCF}]) in all patient groups studied. We also correlated the A10 and \u03b1-angle of the EXTEM and FIBTEM tests to the fibrinogen levels and platelet counts in these patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We retrospectively analyzed 100 sets of EXTEM and FIBTEM results ordered on patients undergoing operations for PPH, patients in intensive care units (ICU), and those undergoing cardiothoracic surgery (cardiothoracic operating room [C\/T OR]). We determined if the correlations among the various parameters were similar among the PPH, ICU, and C\/T OR patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      As expected, the EXTEM A10 (A10\n                      <jats:sub>EX<\/jats:sub>\n                      ) and FIBTEM A10 (A10\n                      <jats:sub>FIB<\/jats:sub>\n                      ) correlated highly to the EXTEM MCF and FIBTEM MCF in all patient groups. The A10\n                      <jats:sub>EX<\/jats:sub>\n                      parameter correlated significantly to both fibrinogen and platelet levels, and the A10\n                      <jats:sub>FIB<\/jats:sub>\n                      correlated to the fibrinogen levels. The difference between the A10\n                      <jats:sub>EX<\/jats:sub>\n                      and the A10\n                      <jats:sub>FIB<\/jats:sub>\n                      (PLTEM) is related to platelet activity, and we found that the PLTEM and platelet count correlated highly for all 100 PPH patients (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.80), C\/T OR patients (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.70), and ICU patients (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.66), despite 4 high platelet counts with relatively low PLTEM values in the ICU group. The earlier-reported parameter EXTEM \u03b1 angle (\u03b1-\n                      <jats:sub>EX<\/jats:sub>\n                      ) is an excellent indicator of the A10\n                      <jats:sub>EX<\/jats:sub>\n                      , with an \u03b1-\n                      <jats:sub>EX<\/jats:sub>\n                      \u226565\u00b0 (ie, normal) giving a &gt;96% probability that the A10\n                      <jats:sub>EX<\/jats:sub>\n                      was \u226544 mm, and an \u03b1-\n                      <jats:sub>EX<\/jats:sub>\n                      value below 65 mm giving an 86% probability that the A10\n                      <jats:sub>EX<\/jats:sub>\n                      was &lt;44 mm.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>\n                      The correlations among the ROTEM parameters for the PPH comparisons were equivalent to the C\/T OR patients studied, and the A10\n                      <jats:sub>EX<\/jats:sub>\n                      and A10\n                      <jats:sub>FIB<\/jats:sub>\n                      could replace the MCF results in all patient groups. Also, the \u03b1-\n                      <jats:sub>EX<\/jats:sub>\n                      was an early indicator of the A10\n                      <jats:sub>EX<\/jats:sub>\n                      and had good correlations to the A10\n                      <jats:sub>FIB<\/jats:sub>\n                      and the fibrinogen in all patient groups. Finally, in a separate group of 62 comparisons, the FIBTEM \u03b1 angle showed promise as an early indicator of the A10\n                      <jats:sub>FIB<\/jats:sub>\n                      and the fibrinogen levels.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1213\/ane.0000000000003499","type":"journal-article","created":{"date-parts":[[2018,6,26]],"date-time":"2018-06-26T17:29:24Z","timestamp":1530034164000},"page":"414-423","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":37,"title":["Use of Earlier-Reported Rotational Thromboelastometry Parameters to Evaluate Clotting Status, Fibrinogen, and Platelet Activities in Postpartum Hemorrhage Compared to Surgery and Intensive Care Patients"],"prefix":"10.1213","volume":"128","author":[{"given":"John G.","family":"Toffaletti","sequence":"first","affiliation":[{"name":"From the Department of Pathology\/Clinical Laboratories, Duke University Health System, Durham, North Carolina."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelly A.","family":"Buckner","sequence":"additional","affiliation":[{"name":"From the Department of Pathology\/Clinical Laboratories, Duke University Health System, Durham, North Carolina."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260517","doi-asserted-by":"crossref","first-page":"iii18","DOI":"10.1093\/bja\/aew358","article-title":"Perioperative management of the bleeding patient.","volume":"117","author":"Ghadimi","year":"2016","journal-title":"Br J Anaesth"},{"key":"R2-20260517","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1111\/j.1537-2995.2011.03241.x","article-title":"A comparative evaluation of rotation thromboelastometry and standard coagulation tests in hemodilution-induced coagulation changes after cardiac surgery.","volume":"52","author":"Ogawa","year":"2012","journal-title":"Transfusion"},{"key":"R3-20260517","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1111\/j.1365-2044.2009.06188.x","article-title":"Use of rotation thromboelastometry (ROTEM) to achieve successful treatment of polytrauma with fibrinogen concentrate and prothrombin complex concentrate.","volume":"65","author":"Sch\u00f6chl","year":"2010","journal-title":"Anaesthesia"},{"key":"R4-20260517","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1093\/bja\/aes374","article-title":"Fast interpretation of thromboelastometry in non-cardiac surgery: reliability in patients with hypo-, normo-, and hypercoagulability.","volume":"110","author":"G\u00f6rlinger","year":"2013","journal-title":"Br J Anaesth"},{"key":"R5-20260517","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1053\/j.jvca.2013.12.004","article-title":"Rapid and correct prediction of thrombocytopenia and hypofibrinogenemia with rotational thromboelastometry in cardiac surgery.","volume":"28","author":"Olde Engberink","year":"2014","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R6-20260517","doi-asserted-by":"crossref","first-page":"1727","DOI":"10.1182\/blood-2014-04-567891","article-title":"Fibrin-based clot formation as an early and rapid biomarker for progression of postpartum hemorrhage: a prospective study.","volume":"124","author":"Collins","year":"2014","journal-title":"Blood"},{"key":"R7-20260517","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1097\/POC.0b013e318259b18a","article-title":"A primer for clinical use of rotational thromboelastometry.","volume":"11","author":"Tanaka","year":"2012","journal-title":"Point of Care"},{"key":"R8-20260517","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1093\/ajcp\/104.4.455","article-title":"Comparison of the kinetic fibrinogen assay with the von Clauss method and the clot recovery method in plasma of patients with conditions affecting fibrinogen coagulability.","volume":"104","author":"Tan","year":"1995","journal-title":"Am J Clin Pathol"},{"key":"R10-20260517","doi-asserted-by":"crossref","first-page":"294","DOI":"10.3758\/s13428-016-0702-8","article-title":"Confidence intervals for correlations when data are not normal.","volume":"49","author":"Bishara","year":"2017","journal-title":"Behav Res Methods"},{"key":"R14-20260517","doi-asserted-by":"crossref","first-page":"S20","DOI":"10.1053\/j.jvca.2013.05.014","article-title":"Management of hemorrhage in cardiothoracic surgery.","volume":"27","author":"G\u00f6rlinger","year":"2013","journal-title":"J Cardiothorac Vasc Anesth"}],"container-title":["Anesthesia &amp; Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00000539-201903000-00008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T14:20:05Z","timestamp":1786112405000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00000539-201903000-00008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":10,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1213\/ane.0000000000003499","relation":{},"ISSN":["0003-2999"],"issn-type":[{"value":"0003-2999","type":"print"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}